| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹23.8 L+₹2.4 L (11.1%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance other than lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical not fulfill required criteria |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
18 Mar 2024, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001 (Punjab)
Repair and Comprehensive maintenance to LT electric supply, LT panels and allied works at Dholewal, CG complex, Doraha and Phillaur under GE Ludhiana
2024_MES_643105_1
GE/LDH-67/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DHOLEWAL, CG COMPLEX, DORAHA AND PHILLAUR
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹50,000
Yes
7 May 2024
19 Feb 2024
20 Mar 2024
19 Feb 2024
18 Mar 2024
4 Mar 2024
19 Feb 2024 - 3 Mar 2024
Amount
Materials and Labour in repairs for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire, complete all as specified and directed.
Material & labour in repairs for Earth continuity conductor or main earthing lead or lighthing conductor,25mmx4mm GI strip, fixed to wall on batten with saddles and fixing screws or PVC/Porcelain insulators etc or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing or roof conductors & down conductors etc as required complete all as specified and directed.
Material & labour in repairs for Earth continuity conductor or main earthing lead or lighting conductor,32mmx6mm GI strip, fixed to wall on batten with saddles and fixing screws or PVC/Porcelain insulators etc or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing or roof conductors & down conductors etc as required complete all as specified and directed.
Material & labour. soldering/Welding/brazing on both sides (over lapping) to the GI strip of any size as earthing lead including dismantling the old from the existing position/equipment without disturbing the functional requirements of the equipments and reconnecting after repair/welding complete all as specifed and directed.
Materials and Labour for provision of concrete earthing pit as shown on electrical plate No 3 of SSR Part –I (2009), in PCC (1:3:6) Type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia. MS bar, including demolition of existing damaged earthing pit and including necessary earthwork in any type of soil, complete all as specified and directed.
S&F in position at various/different locations funnel alongwith wire mesh and replacing existing broken/damaged items complete all as specified & directed.
M& L for earthing complete with & including galvanized MS earth plate of size 600 x 600 x 6 mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire soldered and riveted or connected to earth plate by means of nuts, bolts , check nuts & washers, of galvanized iron or steel all as Shown in electrical plate No. 3 of MES SSR Part- I (2009) and connected to panel board, all as specified and testing on completion including provn of earth wire 4 mmm dia duly protected with and including 15 mm dia bore medium grade GI pipe upto 7.5 (maximum) meter from electrode to earth point including provn of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate and GI light grade watering pipe of 20mm dia bore with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth chamber, 50 mm thick RCC cover using cementconcrete 1:2:4 type B-0 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work and MS frame using MS angle of size 40mm x 40mm x 6mm complete all as specified & directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to the department.
All as per ser item No 7 here-in-before but using galvanised iron strip 25x4mm as earthing lead.
All as per ser item No 7 here-in-before but using galvanised iron strip 32x6mm as earthing lead.
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exc. 1.5 mtr deep for laying of cables and getting out soft/loose soil compete all as specified and directed.
Material and labour for sand cushioing with a layer of fine sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed by Engr-in-charge.Notes-:(i) Excavation and earth work to be measured and paid for separately. (ii)Thickness of 18cms after punning shall be considered for payment.
M&L old size sub class ‘B’ bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other compete all as specified and directed.
Returning filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in trenches compete all as specified and directed.
Removal of surplus soil obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point compete all as specified and directed.
Supply, laying, jointing, testing and commissioning of cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed by means of MS saddles on or fixed on poles including connection with proper lugs for the following size including taking out old one and removing from site (Excavation, earthwork, GI pipe, bricks, sand shall be measured and paid separately)
(a) 70 Sqmm 3.5 Core
(b) 95 Sqmm 3.5 Core
(c) 120 Sqmm 3.5 Core
(d) 150 Sqmm 3.5 Core
(e) 185 Sqmm 3.5 Core
(f) 240 Sqmm 3.5 Core
Supply and fixing in replacment GI pipe light grade 40 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah including taking up old GI pipe complete all as specified and directed by Engr-in-Charge .
All as per ser item No 16 here-in-before but size 50 mm bore
All as per ser item No 16 here-in-before but size 80 mm bore
Supply and fixing in replacement of MCCB current rating 630 Amps with thermal magnetic release, 4 pole, 415 volts AC 50 KA Ics = 50% Icu as per IEC 60947-2ruputuring capacity all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 400 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 350 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 250 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 200 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 125 Amps, 4 pole, 415 volts AC, 25 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 100 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed.
Material & Labour demolition of cement concrete of any description and in any position complete all as specified and directed by Engr-in-Charge.
M & L PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of electric poles, struts, PCC block including necessary form work and fair finish to exposed surfaces without using extra cement etc. complete all as specified and directed by Engineer- in-Charge.
M & L PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in foundation filling upto ground level etc. complete all as specified and directed by Engineer- in-Charge.
M&L PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of poles etc. with slightly rounded or chamfered angles including necessary form work and fair finishing the exposed surface without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for supply,erecting and fixing in position 9 metre long steel tubular swaged pole type 410 SP-22 complete with cast iron base plate, final taper plug, bolts, nuts & screws conforming to IS-2713 (Part- I & III) of 1980 and painting the pole with two coats of aluminum paint over a coat of primer including black and white strips 30cm each upto 1.5 metre from top of PCC foundation block and numbering of poles in 80mm high white letter using synthetic enamel paint over base etc including taking down old existing pole and proper connection with existing condoctor all as specified & directed by Engineer-in- charge.
Supply and fixing in replacement of PVC spacer/separators on LT OH line conductor for 4 wire including necessary nuts, bolts and fixing properly on ACSR conductor complete all as specified and directed by Engr-in-Charge.
M&L for Rewinding of Siren capacity 2KW by using existing size and gauge of PVC insulated copper conductor complete including transportation to Ludhiana contractor's workshop for carryout necessary repair work and transporting it back to site and connecting & testing after fixing complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technique and necessary T&P for passing of LT/HT cables. complete all as specified and directed.
Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT pole/ Lines all as specified and directed by Engr - in - Charge.
Dismantling of existing unserviceable cross arms of any description and in any position complete all as specified and directed by Engr - in - Charge.
Dismantling & taking down of existing worn out / unserviceable GI wire of any description /size & in any position from existing LT Lines including cradle guard/ earth continuty wires complete all as specified and directed by Engr - in - Charge.
Dismantling of existing unserviceable Insulators of any description and in any position complete all as specified and directed by Engr - in - Charge.
Dismantling of existing unserviceable stay assembly of any Size and in any position complete all as specified and directed by Engr - in - Charge.
Dismantling of existing unserviceable cemented concret poles/ struts of any Size and in any position complete all as specified and directed by Engr - in - Charge.
M& L in replacement for cross arms, bracings, supports clamps and back plate fabricated from steel structural including nuts,bolts washers welding,bending cold or hot,drilling holes and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr - in - Charge.
M & L for loop type insulator, porcelain vetrieous white or brown, with overall dimensions of 65mm x 90mm, clearance of hole 16mm complete all as specified and directed by Engr - in - Charge.
M& L for pin type porcelain vitreous, white, brown or green insulators including one galvanized mild steel spindle two galvanized iron washers and one galvanised iron nuts and 65 mm dia , 100mm herght for 1100 volt grade complete all as specified and directed by Engineer-in-Charge.
M & L shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulators bolts, washers and nuts complete 100 mm height and 115 mm dia for 1100 volts complete all as specified and directed by Engr - in - Charge.
S & F in replacement ACSR conductor steel, reinforced on over head lines fixed on insulators, binding with and including binding wire 14 SWG complete all as specified and directed by Engr - in - Charge. ( for payment purposes, the weight of binding wire shall not be consider )
Supplying and drawing and fixing in replacement of continous GI earth wire/guard cradles 4 mm dia including GI binding wire 1.63mm on LT poles complete all as specified and directed by Engr - in - Charge.
M & L in replacement stay assembly comprising of GI stay bow 14 mm dia, 40 cm long ( over all) galvanised stay rod 16 mm dia 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30 cm x 30 cm x 6 mm thick 2 Nos of thimbles, MS clamps made out of 50 mm x 6 mm flat iron complete including stay wire 7/8 SWG complete all as specified and directed including necessary excavation and earth work and PCC 1:3:6 all as shown in electrical plate No.1 of SSR-1991 Part-I (PCC and earth work, loop type insulator, stay clamps shall be measured and paid for separately under the respective item of schedule) including taking down existing old unsv stay assembly complete all as specified and directed by Engr-in-Charge.
Supply and erecting pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1978 including disconnecting and reconnecting ACSR conductor, painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm each up to 1.5 metre height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80mm high letters over 150mm x 230mm yellow base complete all as specified and directed by Engr - in - Charge. (PCC for foundation and earth work shall be measured and paid for separately).
Supply and fix of Aluminium Lugs uitable for 16 to 35 Sqmm 1100Volts including taking down old unserviceable lugs, complete all as specified and directed by Engr - in Charge.
Supply and fix of aluminium Lugs suitable for 70 to 185 Sqmm 1100 Volts including taking down old unserviceable lugs, complete all as specified and directed by Engr - in Charge.
Supply and fixing in replacemnt digital voltmeter (0-500 Volts ) 96x96mm square type including taking out old unserviceable voltmeter complete all as directed by Engineer in charge
Supply and fixing in replacement digital Amps meter (0-600 Amps ) 96x96mm aquare type including taking out old unserviceable seperator complete all as directed by Engineer in charge
Material and labour for replacement of indicator lamp in red, yellow and blue colour with lamp holder multi LED type complete including wiring with copper conductor cable of suitable size all as specified by Engr-in-Charge.
Supply and fixing in replacement of MCCB of current rating 315/320 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable type release including taking down old unserviceable MCCBs complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB of current rating 160 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB of current rating 63 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed by Engr-in-Charge.
M&L for painting of panel board of (Area not more than 8 Sq mtr) inner & outer complete with synthetic enamel paint by spraying including filling cavaties with filler one coat after cleaning all dust/rust including writing the Distribution/Panel Number and panel details all as directed by Engr-in-Charge. Note: The Quoted rates are inclusive of white wash to fountation of Panel Board/ Painting to Angle Frames complete
S&F for jointing and testing LT straight through (heat shrinkable) cable end termination joint suitable for LT cable 11000 volts grade 16 Sqmm to 35 Sqmm complete all as specified and as directed by Engr-in-Charge.
S&F for jointing and testing LT straight through (heat shrinkable) cable end termination joint suitable for LT cable 11000 volts grade 50 Sqmm to 150 Sqmm complete all as specified and as directed by Engr-in-Charge.
Raman Electric Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .