SECRETARY SEETHATHODE GP(AE in charge)
Annual Plan Panal Board Maintenance related work of various Drinking water projects Replacement of defective LV Panel Boards Motor Starters and Motor Pump Sets Pro No S0215/24 of Seethathode GP
2025_DP_722036_1
2/ET/AE/LIDEW/SGP/24-25
Open Tender
Electrical Works
Item Rate
180 days
SEETHATHODE
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,760
Yes
₹31,119
Yes
4 Mar 2025
3 Jan 2025
13 Jan 2025
3 Jan 2025
11 Jan 2025
3 Jan 2025
Amount
Panal Board Maintenance related work of various Drinking water projects (Replacement of defective LV Panel Boards, Motor Starters & Motor Pump Sets)-Project No. S0312/25 of Seethathode GP
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
OD425012/2023-2024:Supply and fixing 160A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL, in the existing Load Bank DB.
OD425013/2023-2024:Supply and installation of 200 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over switch in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, colour washing etc. including giving necessary connections as required.
2.1.5:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 Amp TP&N
2.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
OD427003/2023-2024:Supplying and fixing 100 Amp, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD426715/2023-2024: Supplying and installation of 4 pole sheet steel enclosure with DIN bar (approved make) mounted on wall in recess /on existing cubicle box etc. as required.
OD425363/2023-2024:Supplying, installation, testing and commissioning of Earth Fault (Leakage) Relay, suitable for motor protection, 3 pole, 230V A.C. Trip Current 1-5A, Out put : 1 / 2 Change--over (Potential Free), Sensing through CBCT/Individual CT, Trip delay 0-10 Sec. (Adjustable) with Push Button Reset, LED Indication for Aux. Supply & Trip in ABS Moulded enclosure, size 60x 70x130 mm, Inka make or equivalent L&T/ Siemens/ ABB or other superior make.
OD425603/2023-2024:Supply and installation of Digital Multifunction (VAF) Meter 415V, 3P-4W, to read V, A and F, Accuracy Class 0.5 in position, - Elmeasure/Selec/Meco make or equivalent
OD425611/2023-2024:Supply and fixing in position, Digital Voltage Monitoring Relay, 415V, 3P-4W to observe OV, UV, Single Phasing, Phase Sequence etc. - GIC India make or equivalent.
OD425610/2023-2024:Supply and fixing LED Pilot Lamp, 230V, Vishnu make or equivalent in position including giving connections.
OD427122/2023-2024:Supply and providing LED indicators for all voltage ranges - Blue, Red, Green, Black, Yellow or Orange Colour
OD427125/2023-2024:Supply and fixing 2 A-16A clip-on offset tag fuse link of size F1
OD425044/2023-2024:Supply and laying 2.00 mm thick, 3.3 kV grade, Synthetic elastomeric fire retardant insulating sheet as per IS 15652/06 in position.
OD425045/2023-2024:Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
OD425084/2023-2024:Painting letters or figures of the following sizes with enamel paint as identification mark to Switch Board, Distribution Board, Panel Board etc as required - 2.5cm x 4cm
OD425088/2023-2024:Painting letters or figures of the following sizes with enamel paint as identification mark to Switch Board, Distribution Board, Panel Board etc. as required - 6.5 cm, 8 cm or 13 cm
OD425004/2023-2024:Supplying, installation, testing and commissioning of 20HP, 16Stage, Vertical Open Well Submersible Pumpset operating on 3 phase, 415V, 50Hz supply having ISI certification,, suitable to discharge 360-30 LPM of water to a head of 85-292m with 50mm delivery port, along with all required accessories as per KPWD standards & rules, CRI make, Model : CVH 20/16 or equivalent Ekki (Deccan) / Mahindra/ Texmo/ Taro/ V Guard / Aquatex make with 1 year warranty.
OD425000/2023-2024:Supplying, installation, testing and commissioning of 20HP, Vertical Multistage High Pressure Motor Pumpset operating on 3 phase, 415V, 50Hz supply having ISI certification,, suitable to discharge 492-330 LPM of water to a head of 96-140m with suction and delivery ports of size 65mm delivery port, along with all required accessories as per KPWD standards & rules, Aquatex make, Model : AVRE 65/08 or equivalent Ekki (Deccan) / CRI/ Mahindra/ Texmo/ Taro/ V Guard make with 1 year warranty.
OD424998/2023-2024:Supplying, installation, testing and commissioning of 15HP, 2 Stage, Monoblock Pumpset operating on 3 phase, 415V, 50Hz supply having ISI certification, Class F, IP44, suitable to discharge 444-108 LPM of water to a head of 72-110m with suction and delivery ports of size 65 x 50mm, along with all required accessories as per KPWD standards & rules, Kirloskar make, Model : KDT1598+ or equivalent Ekki (Deccan) / Mahindra/ Texmo/ Taro/ V Guard / Aquatex make with 1 year warranty.
90.14.28.18:S & F Motor starters of the following ratingsFully automatic star delta pump starter for three phase 20HP Submersible motor
90.14.28.7:S & F Motor starters of the following ratingsFully automatic star delta starter for 25HP motor
90.14.28.6:S & F Motor starters of the following ratingsFully automatic star delta starter for 15HP motor
90.14.24.6:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.6 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors.
90.14.24.5:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors.
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
90.2.1.7:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD424272/2023-2024:Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover with 9 W LED bulb to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flexible wire conforming to relevant ISS or extending the original wiring and making good the surface as required.(Mepro /Philips/Crompton/Bajaj make)
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
OD424276/2023-2024:Supply and providing 450 mm metal body wall mounting fan, Crompton make, model - Storm 2 or equivalent Almonard make and suitably mounting on wall or grill, as required including giving connections with required length of 24/0.20 mm, 3 core round copper conductor flexible chord etc. as required.
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
90.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.13.3:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
OD427052/2023-2024:Supply and installation of 63 A 10KA, TP MCB( C curve) suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 in the existing enclosure and giving connections as required
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.2.2:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD424277/2023-2024: Supply and providing 12x3 mm brass bolt and nut with washers on the existing MS box / Earth bus etc. as required including drilling necessary holes as required.
OD424278/2023-2024: Supply and providing 12x6 mm brass bolt and nut with washers on the existing MS box / Earth bus etc. as required including drilling necessary holes as required.
OD424279/2023-2024: Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / Earth bus etc. as required including drilling necessary holes as required.
OD426822/2023-2024:Supply and installation of Pole/Wall mounting type, tamper proof, shockproof, rustproof, rotproof and termite resistant, 100% weatherproof, fire retardant, maintenance-free, cable entry from bottom and/or sides, class FV-0 as per is:11731 part-II or V-0 as per UL-94 , high heat distortion temperature (200°c as per IS:10192), SINTEX make (GSMB 6535) Energy Meter Box (650x350x255mm or nearest) or equivalent make, suitable and with provision to fix three Phase Energy Meter, 3 No. 100/63/32 A, 415 V Bakelite HRC fuse fitting , 63 A, 2 way neutral link, CT's etc. (OR) with DIN Rail in two layers to fix the control gears, including suitable fixing bolt & nut etc. as required.
OD424281/2023-2024:Supply and installation of Pole/Wall mounting type, tamper proof, shockproof, rustproof, rotproof and termite resistant, 100% weatherproof, fire retardant, maintenance-free, cable entry from bottom and/or sides, class FV-0 as per is:11731 part-II or V-0 as per UL-94 , high heat distortion temperature (200°c as per IS:10192) , SINTEX make(GSMB-4537) Energy Meter Box (450x375x200mm) with base plate suitable and with provision to fix Single/Three phase energy meter, 3 No. HRC fuse units, 1 No. neutral link and CTs (OR) with DIN Rail in two layers to fix the control gears, including suitable fixing bolt & nut etc. as required.
OD427137/2023-2024:Supply and fixing 100 A, 415 V Bakelite fuse fitting in the existing meter board and giving connections etc.
OD427130/2023-2024:Supply of 100A, 415V, 2way Neutral link mounted on DMC/ SMC base and fixing in the existing Energy Meter Box and giving connections etc.
OD424284/2023-2024:Supply and providing anchor bolt type hook on wall /parapet for binding KSEB Service connection cable as required.
OD424761/2023-2024:Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 65mm dia. nominal bore, as per Item Specification No. 18.12.7 of General Civil Work for G.I. Pipe laying
OD424762/2023-2024:Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia. nominal bore, as per Item Specification No. 18.12.6 of General Civil Work for G.I. Pipe laying
OD425054/2023-2024:Supplying and fixing GI Socket 50mm with ISI mark, using consumables required.
OD425055/2023-2024:Supplying and fixing GI Socket 65mm with ISI mark, using consumables required.
OD425057/2023-2024:Supplying and fixing M.S. Flange - 2 Inch size using consumables required.
OD425058/2023-2024:Supplying and fixing GI Reducer 62 x 50mm Heavy Duty with ISI mark, using consumables required.
OD425059/2023-2024:Supplying and fixing Hose Clip 2.5 " (62.5mm) size as required.
OD425060/2023-2024:Supplying and fixing M.S. Flange - 3 Inch size using consumables required.
OD425061/2023-2024:Supplying and fixing Non Return Valve, 3 Inch - C.I using consumables required.
OD425062/2023-2024:Supplying and fixing 50mm (2 Inch) G.I Hex Nipple using consumables required.
OD425063/2023-2024:Supplying and fixing 50mm Heavy duty GI Union, using consumables required.
OD425064/2023-2024:Supplying and fixing 65mm Heavy duty GI Union, using consumables required.
OD425066/2023-2024:Supplying and fixing Heavy duty HDPE Suction Hose 2.5 " (62.5mm) size, 16kg/cm2, Plumtek Ganga Gold or equivalent.
OD425069/2023-2024:Supplying and fixing CI Hose Collar 50mm Long, using consumables required.
OD425070/2023-2024:Supplying and fixing CI Hose Collar 65mm, using consumables required.
OD425071/2023-2024:Supplying and fixing Brass Check Valve 50mm, using consumables required.
OD425072/2023-2024:Supplying and fixing 50mm Heavy duty GI Bend, B Class, using consumables required.
OD425073/2023-2024:Supplying and fixing 65mm Heavy duty GI Bend, B Class, using consumables required.
OD425074/2023-2024:Supplying and fixing 65mm Foot Valve - Kirloskar make, model CI 65mm for 15HP, 2 Stage, Monoblock Pumpset .
OD425079/2023-2024:Supplying and clamping 40/32 mm dia corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination points, suitably fixing inside the LV Panel / clamping using suitable size GI / painted MS saddles, spacing not exceeding 60cms on surface etc. as required.
OD427061/2023-2024:Supplying and clamping 25 mm dia. corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination points using suitable size GI / painted MS saddles spacing not exceeding 60cm on surface including making good the damages, colour washing etc. as required.
OD427091/2023-2024:Demolishing R.C.C work manually / by Mechanical means including stacking of steel bars and disposal of unserviceable materials with in 50m lead, as per Item Specification No. 15.3 for Civil works
DINU CHACKO (BID ID -2057487)
Bidder Name
DINU CHACKO
RESMI P R
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1144544.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .