GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPECIAL REPAIRS TO RETRO REFITTING OF ROOF SLAB AND ROOF TREATMENT OF BLDG NO P 82 AT MIL STN GANDHINAGAR
2020_MES_375618_1
GE(A)/GNR/TOKEN/61 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹28,900
Yes
31 Oct 2020
8 Sept 2020
28 Sept 2020
8 Sept 2020
26 Sept 2020
13 Sept 2020
8 Sept 2020 - 12 Sept 2020
Amount
M&L for plain cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges, coving, coved fillets of radious 75mm provided at junctions of roof and parapet/ vertical surfaces and like complete all as specified and directed.
M&L for RCC M-25 ( Design Mix ) (using 20mm graded stone aggregate) as in suspended slabs supported on walls/columns, in floors, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L RCC M-25 (Design mix) using 20 mm graded stone aggregate as in roof beam, cantilevers etc complete all as specified and directed.
M&L for water proofing treatment to existing non-accessible roof slab by applying one coat of cold bituminous primer @ 0.30 litre/sqm and confirming to IS-3384, laying APP based polystr modified membrane reinforced non wooven polyster of 3.50 kg/sqm (minimum) 3mm thick with plain polythene finished and sealing all the overlap 75mm in length side and 100mm in width side of membrane by torching including applying one coat of bituminous aluminium paint over membrane and taking down existing water proofing treatment with bedding layer and land complete all as specified and directed.
Supply only, liquid water proofing compound complete all as specified and directed.
M&L for Brick work with old size, sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for form work to soffit of suspended slabs such as roof slabs, floor slabs, landings and simillar works not exceeding 20cm thick and rough finished surfaces of concrete all as specified and directed.
M&L for form work to sides and soffit of floor or roof beams, beams haunchingss, girders, brussummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc and rough finished surfaces of concrete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for mild steel TMT bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bend to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for machine cut kota stone slab, 550x550mm, 20-25mm thick as in flooring over and including screed bed of 15mm thick in CM (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge.
M&L for rendering cement plaster 10mm thick in cement mortar (1:6) on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:4) on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering cement plaster 5mm thick in cement mortar 1:4 on fair faces of concrete in ceilings, chajjas, fins facia etc. finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick or concrete masonry surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement as primer complete all as specified and directed.
M&L for preparing old plastered or un-plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
M&L for preparing new plastered or un-plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M&L for preparing old plastered or un-plastered surfaces and applying three coat of white wash on ceiling complete all as specified and directed.
M&L for preparing new plastered or un-plastered surfaces and applying two coats of oil bound distemper over Birla/JK white putty on walls complete all as specified and directed.
M&L for preparing old plastered or un-plastered surfaces and applying one coats of oil bound distemper on walls complete all as specified and directed.
Disconnecting, setting aside (or lowering if required) and Cleaning & removing all scale and dirt etc from HDPE water tanks of 5000 litres capacity (Tanks placed on top of roof/staging) and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack clamp complete all as specified and directed.
Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
Dismantling stone slab and tiles af any description or thickness in floors,aprons etc.
Demolition of cement concrete (unreinforced) in ground floor and pavings n exc 15cm thickness (below or above ground level) complete as specified and directed.
Dismantling of reinforced cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, reinforcement cut as required to facilitate demolition complete all as specified and directed.
Dismantling of cast iron, PVC or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required for 110mm and 75mm bore of pipe complete all as specified and directed.
Taking down carefully unserviceable copper/aluminium point wiring (Light, fan, socket or power) complete including unserviceable fittings and fixtures such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, brackets, except ceiling fittings, bulk head fittings, tube light fittings etc. and making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in through and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(b) One multi pin 5 Amps, socket outlet on Independent board.
(c) One multi pin, 5 Amps, socket outlet on the same board controlled by another switch.
S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed
S&F, socket outlet, 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and directed
S&F, in repairs, miniature circuit breakers, single pole, 6 to 32 Amps, 240 volts with 'B' Curve, fixed in sheet metal board complete all as specified and directed. Make : Havells/Legrand/Schneider.
S&F, in repairs, miniature circuit breakers, single pole netural, 40 Amps, 240 volts with 'B' Curve, fixed in sheet metal board complete all as specified and directed. Make : Havells/Legrand/Schneider.
S&F, in repairs, sheet metal distribution board, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar of capacity 200 Amps, SPN, 8 way 240 Volt complete all as specified and directed
S&F, ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed
S&F, in repairs, LED light fitting, batten type, housed in extruded from powder coated aluminium, 20 watt for complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size and testing on completion all as specified and directed. Make: Wipro/Havells/Bajaj
S&F ceiling fan regulators, Electronic type, AC, 230 Volts complete all as specified and directed.
S&F, in repairs, sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, copper multi stranded conductor drawn in and including PVC concealed conduit and conduit assessories including drawing one run of PVC insulated, unsheathed, 600/1100 Volts grade, copper conductor multi stranded, 4 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: (i) 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length. (ii) Rates quoted shall be inclusive of cutting wall for concealing conduit and making good the same in cement mortal 1:3, Make - Havells/Plaza/Ppolycab
Taking down existing ceiling fan and keeping in safe custody and re-installation the same after completion of work complete all as specified and directed.
Ramdev and Sons
Shree Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .