Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical G E RAILWAY ROAD G E RAILWAY ROAD HARIDWAR UTTARAKHAND 249401 UDYAM UK 06 0006002 | HARIDWAR | UTTARAKHAND | 249401 | Accepted-Technical Technically Resonsive |
| 2 | Rejected-Technical | Rejected-Technical Technically Non Resonsive |
Tender Value
₹60 L
EMD Value
₹1.4 L
Closing Date
25 Feb 2026, 3:00 pmClosed
Executiver Engineer
Hrda Office Haridwar
SITC of sports lighting and flood lights under bhupatwala flyover
2026_HRDA_91877_1
SITC_bhupatwala_Flyover
Open Tender
Electrical Works
60 days
Haridwar
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,400
EE
₹1.4 L
23 May 2026
10 Feb 2026
25 Feb 2026
10 Feb 2026
25 Feb 2026
10 Feb 2026
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal) DSR E&M
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 8Way Double door (But without MCB/RCCB/Isolator) DSR 2.13.2
Supply, Installation, Testing and Commissioning of LED White Floodlight Luminaire for Flood lighting with die cast aluminium housing, with powder coating of wattage 250W, >=140Lm/Watt with suitable hood for asymmetric distribution. The beam angle of the fixture shall be 30 deg. The luminaire shall have high optical efficiency, anti aging and anti UV PMMA/PC lenses. with Metal cages for extra protection,./ Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 120 to 270 V AC, 50 Hz, power factor > 0.9. High power LED's shall be SMD type and fixture shall have system efficacy at System level (Not Chip Level) >=40 LPW, Life of fixture (Including Driver): 50K Hrs. @ L70 Lumen maintenance at 35 °C Ambient Temperature. CRI ≥ 70 at 3000K, PF >0.90 & THD<20%, minimum Internal Surge Protection 4KV, 20 kV external surge protector, must be having IP66 & IK 07 Impact rating & Approbation-CE along with IEC Classification Class I, RoHS. Cables Connectors in fixture to be of IP67 Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C. Power Supply Unit of 24V, 6.3A,
Supply , Installation, Testing, Commissioning of Integral Sports Light Fixture with wattage 200W-250W including suitable Power Design , Supply ,luminaires shall be made of High Grade ADC 12 PDC Al alloy housing with Passive Cooling heat transfer technique , offering a totally silent, robust, heat transfer with seperate driver & optical compartmnet for thermal isolation , Injection moulded special PC lens optics ,ensuring low glare & best in class uniformity , corrosion resistant power coating using nano technology process , including all other accessories suitable for cradle mounting & matching the following specifications with 5 Years Warranty : Optical Specifications : LED Make : Cree/Nichia/Lumiled , LED Chip wattage : >2W<=5W , L-70 Life: 50000 Burning Hours SDCM (Mac Adam ellipse): < 5 CCT :5700K (tolerances on CCT: +/- as per ANSI C78:377A) CRI: >70 , Minimum LPW : 145 lm /watt for 30 deg Beam Angle , Driver : Integral encapsulated IP 67 high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-270V Power Factor: > 0.95 , Efficiency >90% ,THD: <10% Inbuilt Surge Protection: >=6KV (20KV External) Flicker free <3% Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Line-Line 440VAC Withstand capacity up to 4Hrs. Mechanical Specifications : Cooling Mechanism : Fixture Housing should be made of Pressire Die Cast with Passive cooling IP Rating: IP66 IK Rating: IK08 Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Certification: BIS Certification for Luminaires & Drivers
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.5sq mm X2 + 1.5 sq mm X1 for earth wire
Supply and Laying of one number 4 coreX 50 Sq mm Aluminium UnArmoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground or pipe or trench as required including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supply and Laying of one number 4 coreX 25 Sq mm Aluminium UnArmoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground or pipe or trench as required including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supply of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete. The instrument chamber shall be saprate and shall comprise of Multifunction meter and current transformer etc. The board shall have suitable cappcity electrolytic aluminium bus bars as per IS:8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC /DMC supports with detchable side covers and shall be suitable for extension on the sides .the switches shall be complete with suitable with cable and boxes ,revers entry boxes in case of pedestal type cable socket compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer Incharge The switch board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm cubical type switch board shall be of Cat A, B & B = II only outdoor type with following incomming and outgoings INCOMMING MCCB-63Amp TPN-01 Multifunction meter-01 RYB Indicators-01Set OUTGOING 32 Amp SP MCB- 04 Nos. 15Amp Combined Socket- 02 Nos.
6A - 32 A ratings SPN 'C' curve 10 KA capacity DSR 2022 E&M 1707
Supply and laying of 20-25mm GI pipe type Earthing as required with proper bends or steel flexible pipe as per site conditions with proper welding of clamps, sockets and other accessories
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.09 MB
BOQ_108817.xls
BOQ • 0.32 MB
bhupatwala_flyover_compressed.pdf
Tender Documents • 15.52 MB
Download all tender documents and submit your bid