Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 519 P SECTOR 3 URBAN ESTATE KURUKSHETRA 136118 | KURUKSHETRA | KURUKSHETRA | HARYANA | 136118 | ₹1.2 Cr | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹1.2 Cr+₹1.1 L (0.93%)Rejected-Finance | ₹1.2 Cr+₹1.1 L (0.93%) | L2 | Rejected-Finance REJECTED |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
21 May 2021, 3:00 pmClosed
commissioner, municipal corporation, ambala city
commissioner, municipal corporation, ambala city
Construction of Community Centre in Valmiki Nagar,Nahan House, Ambala City
2021_HRY_170569_1
MCA/EE/2021/693
Open Tender
Civil Works
Works
255 days
commissioner, municipal corporation, ambala city
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹3.0 L
8 Jul 2021
1 May 2021
21 May 2021
1 May 2021
21 May 2021
1 May 2021
Amount
Providing and fixing 910mm high stainless steel railing as per approved drawing and design consisting of member of SS 304 grade, 16 Gauge, with 50mm (OD) hand rail & balustrade, 16 mm (OD ) mid rails. 100dia x 8mm thick base plate directly mounted on floor using fischer make anchor, complete ( Jindal/ Salem steel ) (NS)
Wiring in 1.5 sq mm PVC insulated copper conductor cable in PVC conduit pipe"heavy gauge ISI marked" (bassed on HSR 31.1 )
1) Fan point
(b) Medium Point
(c) Long Point
2) Light Point
(b) Medium Point
(c) Long Point
3)Twin Control light point with 2 way 5A Single pole switch
(c) Long Point
4) Call bell point including M.S. box of size 180 mm x 100 mm x 60 mm deep for call bell
(c) Long Point
5) 5 pin 5A Plug point including earthing the 3rd pin with 1.5 sqmm copper wire.
(a) Short Point
(b) Medium Point
(c) Long Point
6) 5 pin 15 amp. Plug point with 4sqmm PVC insulated Cu conductor cable including earthing the 3rd pin with 1.5 sqmm copper wire.
(b) Medium Point
(c) Long point
Supply, Erection, Testing & Commissioning of A.C. ceiling fan double ball bearing complete in all respect but without fan regulator. The fan should consume less power
Size 48" sweep (1400mm)
Size 56" sweep (1200mm)
S/E of A.C. Exhaust fan (ISI Marked) suitable for single phase A.C. 230 Volts, 50 HZ capacitor,900 RPM (Heavy Duty) complete with mounting ring frame with four fixing holes but without regulator
i) Size 380mm sweep (6 poles)
HVAC WORK
Supply, installation, testing and commissioning of Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by multiple scroll/DC Twin rotary compressor controlled by individual inverters for each compressor complete with indoor and outdoor units with individual wired and wireless /wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, control cabling and fittings etc. as per details given in specifications and having following items. The out door units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply.
Outdoor Units
Supply, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient multiple scroll/ DC twin rotary compressors(OEM manufactured) fully inverter controlled (individual inverter for each compressor) i.e. changes its speed in accordance to the variation in cooling loads, special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and capacity as mentioned below including all hardware & accessories & including full charging of R-410A refrigerant gas complete i/c powder coating complete as per specifications. The units should be with necessary weather protection coating. The coating should be done before bringing the units to site. Out door units shall be provided with MS stand of suitable size duly painted with corrosion resistant paint suitable for outdoor application. Each ODU in the module or individual unit should have multiple compressors for better redundancy.
All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control.
All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor.
The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identicle of the ODU.
Each ODU wheather used individually or used to make module should have multiple compresors.
All Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. A draft Format of the same need to be submitted along with in the Technical Bid.
Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 50% Load to be >=5.2 at 35 Deg Ambient Conditions
Insurance of Units ,Unloading at site, placement of Oudoor Units on the foundation,stands, co-ordination during execution, rendering necessary guidance for execution, supervision, testing,commissioning and startup of above mentioned VRF/VRV by OEM.
Refrigerant topup or charge must be included in quoted price
Note: The civil foundations reqd shall be made by the tenderer
Make: Toshiba,Mitisubishi Electric,Daikin,O'General
VRV/VRF Indoor Units
Supply, installation, testing and commissioning of below mentioned capacity Ductable/Casettes type Indoor air conditioners complete with fan and fan motor, inter connecting it with refrigerant piping, insulation , cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing.
The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kg/cm2. Indoor units shall have a wired remote control. They shall be operated through from the wired remote control from the respective locations. Corded Remotes are seperately payable.
The Drain pump as a standard accessory and shall be included in the price of units for Cassette /Ductable Acs and should have built in provision of Fresh Air
Ductable ACs
Four Way Cassette Acs along with its Grill Panel
Two Way Cassette Acs along with its Grill Panel
Hiwall Units
Make: Toshiba,Mitisubishi Electric,Daikin,O'General
Providing and fixing of Corded remote controls with cord for ductable/Cassette Acs
Providing and fixing of Cordless remote controls
Centralized Controller
Providing, Fixing & Running Centralized Controller for all VRV/VRF / Indoor /Outdoor Units
Make: Toshiba,Mitisubishi Electric,Daikin,O'General
Refnet / T / Y- Joints
Supply Installation, Testing and commissioning of fittings Ref Net / T / Y-joints etc as per specifications.
Refrigerant Piping
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.
41.3 mm OD (insulation = 19mm)
38.2 mm OD (insulation = 19mm)
34.9 mm OD (insulation = 19mm)
31.8 mm OD (insulation = 19mm)
28.6 mm OD (insulation = 19mm)
25.4 mm OD (insulation = 19mm)
22.2 mm OD (insulation = 19mm)
19.1 mm OD (insulation = 13 mm)
15.9 mm OD (insulation = 13 mm)
12.7 mm OD (insulation = 13 mm)
9.5 mm OD (insulation = 13mm)
6.4 mm OD (insulation = 13 mm)
Make : Rajco/Mandev/Totaline
Ducting
SITC of Factory/Site fabricated GSS Ducting complete with hanging arrangement of fasteners, GI threaded rods etc.
(Make: Eco Duct/Zeco(Sheet Make: Tata, Sail,Jindal)
Nitrile Insulation
Armacell/K-Flex
SITC of Nitrile rubber class-O/Closed cell XLPE Fire retardant insulation 9 mm thick pasted on the outer surface of duct with suitable adhesive complete in all respects with Nitrile tapes.
Armacell/K-Flex
Acoustic Lining
SITC of Acoustic lining of the supply duct with 10 mm thick Accosound Nitrile board with suitable adhesive to be pasted inside of the Plenum duct complete in all respects
10 mm thickness accosound Board
Armacell/K-Flex
Grill/Diffussers
SITC of Aluminium extruded powder coated Grills for supply & return air w/o vcd
SITC of Aluminium powder coated Diffuser for supply & return air w/o vcd
Make:Tristar/Caryaire/Ravistar/Uniaire
Dampers
Supply, installation, testing & commissioning of GI Collar dampers
Supply, installation, testing & commissioning of GI Duct dampers
Supply, installation, testing & commissioning of CBRI approved fusible link Fire duct Dampers for at least 90 min fire rating as per UL555:1955 Specifications without Sleeve
Supplying & fixing of fresh air intake louvers with bird screen dampers along with pre Filter (Aluminum extruded only)
Condensate Drain Piping:
Providing UPVC pipes of various sizes for condensed water drainage from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as approved by architect/consultant/Client
All necessary civil works like cutting & chasing of walls/floor/ glass etc. and make them good thereof
32 MM DIA
25 MM DIA
Make : Diplast/Polypack/Supreme
Control Cabling
Providing & fixing control cum transmission wiring/ Control Cabling of 2 core x 1.5sq. mm copper in suitable conduits between indoor and out door unit & indoor unit & its remote controller.
Make : Havell's,Eko,Finolex,Polycab
Supply & Filling of Refrigerant of 410-A
Providing & Charging of Refrigerant of R 410a for Top up in Piping and Outdoor/Indoor Units of VRV/VRF system.
Make : Honeywell ,Dew Point
Cable Tray
Providing and fixing of perforated type GI Cable Tray (1.5 mm thick) for exposed Running Copper Refrigerant Piping of of Following Sizes including nut bolts G.I Thread rods Complete in all Respect
50mm(H) x 450mm(W) x50 mm(H)
50mm(H) x 300mm(W) x 50 mm(H).
CABINET /IN Line CENTRIFUGAL FANS FOR FRESH AIR
Supply, Installation, Testing & commissioning of Ceiling Suspended Inline type fans. Fans shall be of Low noise direct driven type with all accessories etc.complete as per specifications & drawings.(Installation of fans shall mean unloading, lifting-shifting, positioning,levelling & installation in place)
1500 CFM ,30 mm Static
Make : Edgetech ,Zeco,Waves,Carrier
Underdeck Insulation
Providing & Fixing Underdeck Insulation with 50 mm thick TF Quality EPS of Density 20 Kg/M3 fixed to slab with good quality Black CPRX Compound. 28Gwirenet shall be tightened arround insulation so as avoid any kind of sagging, Ends of net shall be overlapping at least 25mm. Overlaps shall be screwed with galvanized screws to avoid rusting
FIRE FIGHTING
SITC of Manual call point with mounting box complete as required.
Sitc of Electronic hooter 6 watt output TAC approved with a range of 25-30 mtr.
providing, installing, connecting, testing and networkable logic driven analogue addressable Main Fire Alarm Control and indicating panel.The panel shall be coupled to the PA system complete in all respect. 4 loop Panel
Wiring with 2X1.5 sqmm solid PVC insulated copper conductor 100 volt grade wires in with concealed conduit including terminations, all labour and material etc complete
Supply/Fixing of self illuminated "EXIT" sings made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed of the walls as required and as directed at site.
Supply, installation, testing and commissioning of Analogue addressable Photo Smoke Detectors based with LED shall be visible from 360deg, complete as required. (Make :/ GST/Morley)
Supply, Installation, Testing and Commissioning of Fault Isolator (GST/Morley)
Supply, Installation, Testing and Commissioning of Control Module. (GST/Morley)
Supply and fixing Response Indicator with Dual LED
Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018-1131 (A)
Supply & fixing of CO2 type fire extinguisher, 6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018-1132 (A)
PART-II-SPRINKLER SYSTEM
Supply, Installation, Testing and Commissioning of M.S. Pipe 'B' Class as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc. and coating of Primer and P.O. Red Paint. Make : QST/Jindal Gzb.
Supply, Installation, Testing & Commissioning of Butterfly Valve Complelte in all respects.(Make : SIR/Kartar)
150 mm dia
Supply, Installation, Testing & Commissioning of Flow Switch, complete in all respects. (Make:- System Sensor)
150 mm dia
Supply, Installation, Testing & Commissioning of Alarm Control Valve, complete in all respects. (Make:- System Sensor)
150 mm dia
SITC of Sprinkler 68° deg, complete in all respects. (Make:- OMEX/ Life Guard/Safex)
Pendent/Upright Type
Wall Mounted Type
Supply, Installation, testing and Commissioning of Normal type Rosette Plate for sprinkler
Supply and Laying of Armoured Cable 2x1.5 Sqmm. (Make:- Relison/ Paradise/ Polycab/Pirelli)
Supply and installation of Air vessel of 300 mm dia, 1000 mm height, 6 mm thick dished end 8 mm thick.
Supply and installation of Announcing Panel
SITC of Air release valve.
PART-III-(FIRE FIGHTINGEXTERNAL)
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m. including getting out the excavated soil & then returning the soil as required
in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. & disposing of surplus excavated soil as directed within a lead of 50m.
a) Pipes 80mm to 300mm diameter. DSR-16(2.10.1.2)
Constructing masonry Chamber 60x60x75cm, inside with 75 class designation brick work in cement mortar 1:5 (1 cement : 5 fine sand) for fire hydrants, with C.I. surface box 350x350mm top and 165mm deep (inside) with chained lid and RCC top slab 1:2:4 mix
(1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement :
3 coarse sand ) 12mm thick finished with a floating coat of neat cement complete as per standard design. DSR-16(18.36.1)
Supply, Installation, Testing and Commissioning of one coat of 4 mm thick 'PYPKOTE' or coatek tape anti rust pipe protection , primer and lap of 25 mm on external M.S. pipes to make an impermeable layer in trenches or on structural/masonry members complete including surface preparation.
150 mm dia
Supply, Installation, Testing and Commissioning of M.S. Pipe 'C Class Heavy as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc, complete in all respect.
MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground)
SITC of Sluice Valve complete with all respect.
MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground)
150 mm dia
Supply, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts.
MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground)
150 mm dia
SITC of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Newage/Minimax/Safex/Firex)
SITC of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree/CRC)
SITC of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex)
Supply, Installation, Testing & Commissioning of Butterfly Valve complete with flanges, gasket, nut bolts
SITC of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle
Supply, Installation, Testing & Commissioning of Fire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet.(4 WAY)
Hall Interior
Features : Premium pure leather upholstery Structural parts in chrome and SS finishes Auto mechanism for back tension adjustment Range of comfort adjustments - seat height, seat depth, back height, armrest height, back tilt angle limiter Wide armrest to support various arm width and postures Ergonomically sound - Back height supports the user’s full back and height adjustment offers alignment with the user’s body contours The wide and soft-edge PU arm-top provides full support to the forearm & elbow region without the need for creating a swivel feature The arm support is located nearer to the back creating ample space for leg movement and moves along the recline motion
Acoustic
Suppling, Fixing and testing of Soundproof False Ceiling/Acustic Ceiling, 24 MM plane T-Grid with 15 mm Thick 595 x 595 MM Tegalur Pin hole Tiles/Ployister Fiber Acustic Panel/Tile with main T 3000 mm length, 1200 and 600 mm lenth Cross Section and 2400 mm length Wall angles.. Fasnter 3 mm with SS Butterfly for hanging in Concreete Ceiling, 25 mm length Gysum Screws.. Material Specification: T- Grid- Armstrong/Boral, Tiles: Armstrong/Boral/KQ Seats.
Suppling, Fixing and testing of soundproof walls/Acustic Walls, with 12 mm thick Medium density FiberBoard (MDF) Wooden Slats size upto 1200 mm Height from Floor then remaing with 12.5 mm thick gysum board, 50 mm thick GI channels, Studd and Floor for Framing. 90 DB Glass wool and Tissue paper insulation for sound proofing with 25 mm Length Gysum screws with Jointing Tape and Compund, covered with Colorfull 9 mm thick polyster Fibre board. Material Specifations: MDF Wooden Stalts: Action Tesa/Century, Gysum Board: Boral/Gyproc, Studd and Floor: Boral 0.4/ Gyproc Expert, Glasswool: Sipla, Svcrews: Boral/Gyproc, Compound: Boral/Gyproc, Jointing Tape: Boral/Gyprot, Ployster Fiber Panel-KQ Seats.
Stage Engineering: Main Curtain & Rear Curtain: •Velvet Cloth withhorizontal sliding arrangement Wings: •Fire Retardant Crape Cloth •Swiveltype •Construction -MSFrame, •Covered with 6mm Ply & 12mmU Gypsumboard •BorderFrills •Fire RetardantFabric •PleatedStitching BorderFrills: •Fire RetardantFabric •PleatedStitching •Moving Bars and their Drives: •Remote Operated MotorizedBars. •LightBars •SetBar •Retractable CableArrangement •Electrical SocketDistributions
MultiPurpose Hall Stage Lighting and Engineering
Supply, Fixing and Testing of StageLighting & Stage Furnishing: Furnishing20Theauditoriumshallbeequippedwithfollowingequipmenttoachievethedesiredfunctionalities(asproposedinthepreviousslide:StageLighting&Furnishingshallbecomprisedof: •Main/FrontCurtain •BackCurtain •StageWings •BorderFrills •ProfileLights •LED PARLights •MovingHead •LED RGBLight •LED FlasherBar •LED FersnalLight •Follow SpotLight •LightingDimmer •Truss Bar/Moveable Baretc.
Stage Lighting: Various kind of lights have been proposed •Conventional Groups andzones •Intelligent Light Fixtures for Troops andDances. •Use of Latest in Lighting Technology –DMX programmable Lighting Controls •Hybrid Usage of LED’s Lights and Conventional Tungsten lampfixtures. •TheatricalLighting. •Lighting for Dance and Musical Extra vaganza
Audio and Video System
Aventageseries AV Reciever-RXA1080 (Yamaha) AV Receiver
Front Left & Right Column Array: VXL24 (Yamaha) Full-range, Bass reflex; Frequency range-77 Hz –20 kHz *1, 98 Hz –20 kHz *1 (with port cover) ; Nominal Coverage: H-170°, V-15°(+7.5°–-7.5°) (NORMAL), 20°(+7.5°–-12.5°) (WIDE); LF-HF:1.5” (3.75 cm) Cone ×24; Power rating-220 WPGM; Nominal Impedence-8Ω; SPL-117 dB SPL (1 m) Peak; IP34 (IP35 with port cover) LCR Speakers
Delay Speakers : VXL 16 (Yamaha) Full-range, Bass reflex, Coverage H180xV30; 1.5” (3.75 cm) Cone ×16; PGM 160W; Frequency-81 Hz –20 kHz *1, 108 Hz –20 kHz *1 (with port cover),; Max SPL 116db; IP rating 34; Dimensions-W54×H846 ×D104 mm (Speaker only), W54 ×H846 ×D111.5 mm (With included bracket)Surround/ Delay speakers
Subwoofer : DXS 12MKII (Yamaha)Speaker type : 12" powered subwoofer, Band-pass type , Frequency range (-10dB) : 42Hz -150Hz , Components : 12" cone, Voice Coil:2.5" , Output power : Dynamic:1020W / Continuous: 800W ,Maximum output level (1m; on axis) : 134dB SPLSub woofers
Amplifier for speakers: PX5 (Yamaha) Dual Channel ; Class-D Amplifier with Output Power (Single Channel) : 2 X 500W @ 8 Ohms ; 2 X 800W @ 4 Ohms ; 2 X 500W @ 2 Ohms ; Output Power (Bridge Mode) : 1 x 800W @ 8 Ohms; 1X 1400W @ 4 Ohms ; Sampling Rate : 48 kHz ; A/D & D/A Conversion : 24 Bit ; THD : 0.1% ; S/N ratio : 100dB ; Crosstalk : Less than -60dB ; Voltage Gain : 32 dB ; Built in DSP Features : D-Contour for (FOH/MAIN, MONITOR, OFF); Delay; HPF/LPF with polarity control; Speaker Processor(6 band PEQ + Limiter + Delay) , Speaker Presets for Equalization ; LCD Display ; Line Inputs : XLR-3 X 2 & 1/4 TRS X 2 , Output : SpeakonX 2 , 1/4" TS X 2 ; Others USB2.0 for Speaker Preset & Firmware Update .Amplifier for LCR
Mounting bracket for Delay speakers : WMB-L1B (Yamaha)Mounting Brackets
Digital Signal Processor : MTX3 (Yamaha) Mixing channels : Mixing Channel : 8 Mono + 3 Stereo + 2 Effect Return + 8 Direct-in to Matrix/ Output Busses : 8 Mono , Input channel functions : Mono CH : 3-band PEQ, Comp, Gate, Auto Gain Control, Feedback suppressor (only available in ch 1-4)/ Stereo CH: 3-band PEQ, Comp, Auto Gain Control , Output channel functions : Room Delay, Room EQ, Speaker Processor, X-Over (1way,2way), Delay, 6 band PEQ, LimiterDigital Signal Processor
8 input expansion card : EXI 8 (Yamaha)Input Expansion
D55Wired Vocal Microphone: D5S (AKG
D40 Wired InstrumentMicrophone : D40 (AKG)
CGN 521STS50cm Gooseneck microphonefor podium : CGN 521STS (AKG)
CTP-1301 50cm Gooseneck microphonefor podium : CGN 521STS (AKG)Presentation Connectivityand Transport Kit : CTP-1301 (AMX)Presentation Connectivityand Transport Kit : CTP-1301 (AMX)
Strong MDI 2.5 Gain Silver 35.5ft*20.5ft-Stereoview 3DScreen
Vivitek 8000 Lumens Full HD 3D Laser ProjectorProjector
All Neccwssory wires, hardware, Installation, Software, Training.Wiring, sound rack, projector mount and Installation
Bidder Name
Amount
Sh. Ram Kumar(GSTN-06AACFR3025L1ZB)
MS B.S.Construction Company(GSTN-NA)
Sh. Ram Kumar
Sh. Ram Kumar
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_226696.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .