Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 192 SURYA NAGAR GOPALPURA BY PASS ROAD JAIPUR RAJASTHAN 302015 | JAIPUR | RAJASTHAN | 302015 | Accepted-Technical ok |
| 2 | Not Admitted-PreQual/Technical | Not Admitted-PreQual/Technical Not Complied with technical specification |
Tender Value
₹48.1 L
EMD Value
₹96,220
Closing Date
14 Jan 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMISSIONER,
COMMISSIONER,MUNICIPAL COUNCIL, PHALODI
Maintenance and operation of tubewell in various ward of nagar parishad paalodi
2025_DLB_524154_2
NPP/2025-26/8733
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Percentage
90 days
PHALODI
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
COMMISSIONER MUNICIPAL COUNCIL / MDRISL
₹96,220
Yes
18 Feb 2026
31 Dec 2025
15 Jan 2026
31 Dec 2025
14 Jan 2026
31 Dec 2025
Revised PHED BSR 2023 / 2.15-Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034/2018 (pump) and IS 9283/2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 2.15.12- 15 KW (20 HP) and above, head above 120 mtr.
Revised PHED BSR 2023 / 2.19-Supply & Fixing of ISI marked three core PVC flatsubmersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 2.19.3-3 core 10.0 Sq.mm
Revised PHED BSR 2023 / 2.2-Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098/I/1554/1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 2.20.4-35.0 Sq.mm, 3.5 core
Revised PHED BSR 2023 / 2.24-Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 2.24.3-65 mm dia
Revised PHED BSR 2023 / 2.18-Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star/delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M/15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 2.18.4-Above 20 HP and up to 30 HP
PHED O&M BSR 2020 / 7.3-Maintenance of tubewells which includes round the clock monitoring of tubewells of all sizes, complete repairs / rewinding of submersible pump sets including cost of material components required to repair pumpsets, starters, meters etc. of electric panel of tube wells, Lowering and unlowering of pumpsets complete in all respect, maintenance of log-books & Histroy sheet as directed by Engineer-in-charge for tubewell per month. (For Urban water Supply Scheme) 7.3.7-26.0 HP to 45.0 HP
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.77 MB
NITDOCUMENTSNEW.pdf
Tender Documents • 6.09 MB
BOQ_935296.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .