| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹16.7 L+₹24,014 (1.46%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance L1 Being accepted | |
| 3 | L3₹22.4 L+₹6.0 L (36.4%)Rejected-Finance 22 1755A KANNANKATTU TEMPLE ROAD EDAKOCHI KOCHI 682010 ERNAKULAM KERALA 682010 | ERNAKULAM | KERALA | 682010 | L3 | Rejected-Finance L1 Being accepted | |
| 4 | L4₹23.2 L+₹6.8 L (41.1%)Rejected-Finance | L4 | Rejected-Finance L1 Being accepted |
Tender Value
Refer Docs
EMD Value
₹49,000
Closing Date
12 Oct 2020, 6:00 pmClosed
GE(I)(CG) KOCHI
GE(I)(CG)KOCHI BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507
DAY TO DAY MAINTENANCE REPAIR TO INTERNAL EXTERNAL ELECTRIC SUPPLY, DG SET, LIGHTING PROTECTION SYSTEM, STREET LIGHTS , REFRIGERATION AND AIR CONDITIONING ETC AT CGDHQ 4 FORT KOCHI AND CGRA RAMESWARAM, KOCHI
2020_MES_376831_1
GE/CG/8724
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Kochi
AS PER NIT/TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I)(CG) KOCHI
₹49,000
Yes
5 Nov 2020
11 Sept 2020
13 Oct 2020
11 Sept 2020
12 Oct 2020
28 Sept 2020
11 Sept 2020 - 18 Sept 2020
Amount
Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FR) upto and including working voltage 1100volts grade, drawn through and including PVC casing and caping including all accessories ISI marked including press fit white PVC open switch/surface board high strength and crack resistance and unsheathed copper conductor stranded cable(FR) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-.
(a ) one light point controlled by one switch 5 Amps
(b ) one fan point point controlled by one switch 5 Amps
(c) One 3 pin socket outlet 5 Amps on Independent board
(d ) One 3 pin socket outlet 5 Amps on same board
( e) One bell point controlled by one bell push
All as per Item No. 2 above but with 4 sq mm PVC insulated copper conductor cable(FR) including 4 sq mm PVC copper conductor used as earth wire for power point on independent board for One 3 pin socket outlet, 15 Amps.
Supply and fix Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix Switch Socket Combination 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix Switch Socket Combination 2 in 1, 5 Amps /16 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix Socket outlet 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed.
Attending internal/ external electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in LT panels/Overhead HT/LT lines, transformers, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge. Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid. (b) The spares required for the rectification of fault shall be measured under items 15 to 38.
Supply only Switch piano Flush, single pole, one way 5 amp complete all as specified and directed.
Supply only of Switch Socket Combination 2 in 1, 5 Amps flush type complete all as specified and directed.
Supply only Switch Socket Combination 2 in 1, 5 Amps /16 Amps flush type Complete all as specified and directed.
Supply only Bell electric ding dong 230 V complete all as specified and directed.
Supply only Bell push 5 Amps one way complete all as specified and directed.
Supply only Electronic fan regulator 230 volts, step type,socket type, hum free 120 watt ISI Marked complete all as specified and directed.
Supply only Ceiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed.
Supply only Lamp holders baklite body with back plate suitable for battern fitting/angle fitting complete all as specified and directed.
Supply only of Modular switch, one way, 6Amps complete all as specified and directed.
Supply only Modular switch, one way, 16Amps complete all as specified and directed.
Supply only Modular switch, two way, 6 Amps complete all as specified and directed.
Supply only Modular socket outlet, 6 Amps, 2 and 3 pin combined complete all as specified and directed.
Supply only Modular socket outlet, 6 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed.
Supply only Modular fan regulator step type, 120 Watt complete all as specified and directed.
Supply only Modular Bell push, 6 Amps complete all as specified and directed.
Supply only Modular switch socket combination 16 A 6 pin complete all as specified and directed.
Supply only Condenser 2.5 Mfd AC 240V, complete all as specified and directed.
Supply only Condenser 4 Mfd AC 240V, complete all as specified and directed.
Supply only LED tube light batten 20 watt, 240 volts complete all as specified and directed. Make: CELS Cat part No CLLC-TBLP-20 or equivalent in Philips/Bajaj/Surya.
Supply only LED bulb 9 watts, 230 volt complete all as specified and directed. Make: CELS Cat part No CLLC-LP-10 or equivalent in Philips/Bajaj/Surya.
Supply ony LED mirror light of 10 Watt complete all as specified and directed. Make:Cat No CLLC-MRL-10 of CELS or equivalent in Havells Philips/Bajaj/Surya.
Supply only MCB single pole & neutral 240 volt C curve 10 KA 63 Amps capacity IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper lugs complete all as specified and directed.
All as per ser item No 36 above but MCB TPN 415 volt C curve 10 KA 40 Amps capacity complete all as specified and directed.
All as per ser item No 36 here-in-before but MCB single pole, 6 to 32 Amp 240 volt C curve 10 KA complete all as specified and directed.
Material and labour for Sub main wiring using two runs of single core PVC insulated cable(FR) 4 sqmm copper conductor multi stranded and one run of 4 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC casing and caping including taking down old aluminium/Copper Sub main wirng complete all as specified and directed. Note- 3 run of 4 sq mm PVC copper wire and One run of PVC casing caping shall be measured and paid as one unit.
Material and labour for Sub main wiring using two runs of single core PVC insulated cable (FR) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC casing and caping including taking down old aluminium/Copper Sub main wirng complete all as specified and directed. Note- 3 run of 6 sq mm PVC copper wire and One run of PVC casing caping shall be measured and paid as one unit.
Material and labour for Sub main wiring using four runs of single core PVC insulated cable(FR) 6 sqmm copper conductor multi stranded and two runs of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including non metallic PVC conduit pipe ISI marked of size 25 sq mm including taking down old aluminium/Copper Sub main wirng complete all as specified and directed. Note- 6 run of 6 sq mm PVC copper wire and One run of PVC conduit shall be measured and paid as one unit.
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 415 volts, MCBs used as incommer Double door, flush to wall complete all as spd and directed .
All as per ser item No 42 above but SPN 2 way, single door 240 volts
All as per ser item No 42 above but SPN 4 way, double door 240 volts.
All as per ser item No 42 above but SPN 8 way, double door 240 volts
Supply and fix in repairs single pole and neutral enclouser with a two pin and earth plug and socket complete with and including one MCB single pole 20 Amps complete all as specified and directed.
Taking down fan of any type and size after disconnecting, depositing to store yard and Hanging/fixing only after repair/reconditioning fan of any type and size all as directed. NOTE: Repair and reconditioning of fan shall be measured and paid separately under Item Nos.48 to 53.
Collecting unserviceable ceiling fan 1200mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceable winding from fan stater & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed. Note : (i) Taking down and refixing after repair work shall be measured and paid under Item No.47 above. (ii) Spare such as Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps etc shall be measured & paid separatetly under item Nos.54 to 61.
All as per item No 48 above but exhaust fan 300 mm sweep
All as per item No 48 above but Wall fan 450 mm sweep
All as per item No 48 above but Wall fan 300 mm sweep
Material and Labour for Scraping down old paint of ceiling fan of any size 1200 mm sweep complete body & blade including down rod filling the cavities with filler and making smooth surface by applying sand paper painting the ceiling fan by means spray gun/brush with synthetic enamel white paint complete all as specified and directed.
Material and Labour for lathe work for proper filling/fixing of bearing/bushes in the top cover of the fan by filling a layer of matter after blazing & bottom cover of fan complete all as specified and directed.
Supply only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL
Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample
Supply only Gun metal bush for ceiling fan complete all as specified and directed.
Supply only Shackle type rubber reel,'U' clamps, bolts,split pin & washer complete all as specified and directed.
Supply only Canopy top/bottom suitable for 20mm dia rod complete all as specified and directed.
Supply only Down rod 300mm long of size 20mm dia ISI marked complete all as specified and directed.
Supply only Fan blades suitable for 1200mm sweep fan make & type complete all as specified and as directed .
Supply only 1.2mm thick mild steel top/bottom cover for ceiling fan any size and make complete all as specified and as directed .
Supply and fixing in repairs Exhaust fan blade (three leaves) of 450mm sweep complete as per sample of the following sizes complete all as specified and as directed .
All as per item No 62 above but for 380mm sweep
All as per item No 62 above but for 300mm sweep
Supply and fixing in repairs Exhaust fan clamps including frame and louvers with rubber bush, etc suitbale for 450mm sweep complete as per sample complete all as specified and as directed .
All as per item No 65 above but for 380mm sweep.
All as per item No 65 above but for 300mm sweep.
Supply and fixing in repairs Wall mounting fan blade 400 mm sweep (three leaves) and make suitable for fixing and as per sample of existing fan complete all as specified and directed .
Supply and fixing wall mounting fan blade 300 mm sweep (three leaves) and make suitable for fixing and as per sample of existing fan complete all as specified and directed .
Supply and fixing in repairs oscillating mechanism suitable for wall mounting fan any make and type all complete all as specified and as directed .
Supply and fixing in replacement of Exhaust fan Motor of 450mm sweep heavy duty complete as per sample of the following sizes complete all as specified and as directed .
All as per item No 71 here-in-before but for 380mm sweep
All as per item No 71 here-in-before but for 300mm sweep
Supply and fixing unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc.15 mm bore including taking down old unserviceable pipe complete all as specified and as directed.
Supply and fix in repairs LED recess suitable for false ceiling 2 ft X2 ft, 40 watts , 240 volts AC supply complete all as specified and directed. Make : Cat part No CLLC-RMLSS-40 of CELS or or Equivalent in Crompton Greaves / Havells.
Taking down carefully geyser of any make and capacity 25/50ltrs, dismantling the geyser for inspection, cleaning of tank, repalcement of defective part such as heating element, thermostat switch, spacer ring, safety plug, glass wool, neon lamp, head assembly, rubber gasket, top and bottom cover, inspection plate, copper cable 3 core, 3 pin Top plug, element holding clamp, welding of studs for head assembly, defective inner and outer shell reassembling the geysers with one coat of milky white synthetic enamel spray paint of approved quality after cleaning of all dust rust etc and writing of MES No on the geyser using black paint, Reinstallation of geysers to its original postion complete all as specified. Note : Spare parts such as heating element thermostat switch, spacer ring, heon lamp, head assembly, glass wool, safety plug rubber, gasket, copper cable, top & bottom cover, inspection plate, CP & PVC connection, Plug Top, Outer & Inner shell element holding clamps etc shall be measured & paid for seperately in respective items here in after.
Supply only heating element any type (i.e; Cup,thread or triangular) 1.5 KW, 220/230 volts ISI marked.
Supply only heating element any type (i.e; Cup,thread or triangular) 2.0 KW, 220/230 volts ISI marked.
Supply only Thermostat ISI marked complete all as specified and complete all as specified and as directed .
Supply only Head Assy"Brass" 8 to 9 holes suitable for 25 ltrs capacity all complete all as specified and as directed .
Supply only Safety plug "brass" ISI marked suitable for 25/50 ltrs geyers
Supply only PVC connections 15mm size for Hot and cold water connection with rubber washer & brass nuts, ISI marked of length 600mm complete all as specified and directed.
Supply only copper flexible 3 core PVC insulated,PVC sheathed FR, ISI marked of size 2.5 sqmm copper conductor complete all as specified and directed.
Supply only geyser inner assembly of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity all as specified and complete all as specified and as directed .
Supply only bottom cover plate in two halves with self toppiry suitable and as per sample complete all as specified and directed. Make :Bajaj, Peeco, Recold/DITZ
Supply only phase indicator red colour circular/rectangular shape as suitable and as per sample complete all as specified and directed.
Supply and fixing in repairs non return brass valve of 15mm bore, ISI marked complete all as specified and as directed .
Supply and fixing in repairs pressure release brass valve of 15mm bore ISI marked complete all as specified and as directed .
Supply only PVC connections 15mm size for Hot and cold water connection with rubber washer & brass nuts, ISI marked of length 450mm complete all as specified and directed.
Supply and fixing in repairs Plug top 3 Pin 15 Amps 230 volts complete all as specified and as directed .
Material and labour for servicing including cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil for split type AC of any make/ capacity after taking down the whole unit and refixing at the existing location or any other new location after servicing all as specified and directed . Note: Spare parts shall be measured and paid separately under relevant item.
Material and labour for Shifting of split type AC existing location to the new location and making good the opening of old location with cement mortor 1:3, treating the wall to matching with existing surfacce finish and making opening holes on brick wall at new location and gap well finish with cement mortor 1:3, making good the wall surface to match with existing surface, installation and commissioning with replacement of insulation of suction & discharge line complete all as directed.
Material and labour for Shifting of water cooler electric driven single phase having any make and capacity existing location by taking it after disconnection of electric and water line and refixing the same in any other new location including water and electric reconnection and commisioning complete all as specified and as directed.
Supply and fix in repairs Printed Circuit Board suitable for 2TR Capacity Split Unit Air Conditioners including remote, etc. all as specified and as directed. NOTE: Make of PCB & remote shall be of existing manufacturer as compatible with the AC.
Supply and fix in repairs Printed Circuit Board suitable for 1.5TR Capacity Split Unit Air Conditioners including remote, etc. all as specified and as directed. NOTE: Make of PCB & remote shall be of existing manufacturer as compatible with the AC.
Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filled with compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and as directed. Make : LG/ Voltas/ Samsung
Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filled with compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and directed. Make : LG/ Voltas/ Samsung
Disconnecting, dismantling and taking out existing burnt out compressor from water cooler of capacity 40 to 80 Ltr per Hour singlephase 230 volts and supply and fixing compressor unit of water cooler of capacity 40 to 60 ltrs complete all as specified and directed. Make : LG/ Voltas/ Samsung
Supply and fix in repairs AC blower fan motor for AC suitable for 2 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed.
Supply and fix in repairs blower fan motor water cooler capacity 40/80 suitable operate on 230 Volt AC supply at 50 HZ complete all as specified and directed.
Supply and fix in repairs Capacitor 45 MFD complete all as specified and directed.
Supply and fix in repairs Capacitor 50 MFD complete all as specified and directed.
Supply and fix in repairs Thermostat switch for water cooler/Window AC complete all as specified and directed.
Supply and fix in repairs Drier stainer filter suitable for AC/Water cooler/Refrigertor complete all as specified and directed.
Supply and fix in repairs insulation Nytrile foam insulation suitable for 5/8 inch copper tube as per site requirement of approved make all as specified and directed .
Supply and fix in repairs insulation Nytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved make all as specified and directed .
Supply and fix in repairs Copper tube 5/8 inch size as per site requirement of approved make all as spd and directed .
Supply and fix in repairs Copper tube 1/4 inch size of approved make all as specified and directed .
Supply and fix in repairs Evaporator unit (indoor unit ) complete suitable for 2 TR Capacity Split type Air Conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/ Voltas/Goderj
Supply and fix in repairs Condensing (Out door) unit complete including compressor, etc. suitable for 2 TR Capcity Air conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/Voltas/Goderj
Supply and fix in repair Bracket stand suitable for 2 TR Capacity Split type AC including Fastners, etc. Complete all as specified and directed.
Supply and charging R-22 gas to maintain the required cooling effect as and when required in the split AC/ window type AC & other cooling applinces complete all as specified and as directed.
Supply and charging R-134 gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated soil and depositing to the sides and returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm thick in soft/loose soil after cable is laid complete all as specified.
Material and labour for providing dry screened river sand as in sand cushioning to under ground cable including punning down of sand by layer complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
Supply and laying cable protection cover un- reinforced precast concrete cable covers class LV, type-1 flat size 250mmx150mmx40mm for cable protection complete all as specified laid perpendicular to cable as per directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 95 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
All as per item No 119 above but of size 50 Sqmm 3.5 core.
All as per item No 119 above but of size 35 Sqmm 3.5 core.
All as per item No 119 above but of size 25 Sqmm 3.5 core.
All as per item No 119 above but of size 16 Sqmm 4 core.
All as per item No 119 above but of size 10 Sqmm 4 core.
Material and Labour for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
All as per item Serial No 125 above but for 50 mm dia pipe.
All as per item Serial No 125 above but for 80 mm dia pipe.
Supply & Fix in repairs MCCB 4 pole 415 Volts adjustable type of capacity 63 Amps, 10 KA breaking capacity fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Cat part No IHLE1ABF0063 of Havells or Equivalent in L&T / Legrand.
All as per Item No 128 here-in-before but of capacity 100 Amps. Make: Cat part No IHLE1ABF0100# of Havells or Equivalent in L&T / Legrand.
Supply & Fix in repairs MCCB 4 pole 415 Volts adjustable type of capacity 125 Amps, 25 KA breaking capacity fixed properly at directed location and connecting/testing complete all as directed. Make: Cat part No IHLASF00125# of Havells or Equivalent in L&T / Legrand.
All as per Item No 130 here-in-before but of capacity 160 Amps. Make: Cat part No IHLANF0160# of Havells or Equivalent in L&T / Legrand.
All as per Item No 130 here-in-before but of capacity 200 Amps adjustable type, 25 KA breaking capacity. Make: Cat part No IHLANDCF0200# of Havells or Equivalent in L&T / Legrand.
All as per Item No 130 here-in-before but of capacity 250 Amps, adjustable type, 36 KA breaking capacity. Make: Cat part No IHLLSEBF0250# of Havells or Equivalent in L&T / Legrand.
All as per Item No 130 here-in-before but of capacity 400 Amps. Make: Cat part No IHLLSEBF0400# of Havells or Equivalent in L&T / Legrand.
Supply and fixing shock treatment chart duly framed using 1st class hard wood frame size 25mmx15mm treated french polish, mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs with 5mm thick plain glass, the area of board 1.20 Square Metre complete all as specified and directed.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and directed.
Supply and fix in repairs switch disconnector four pole , 415 volts 160 Amps complete all as specified and directed. Make: L&T/Havells/Legrand/Crompton Greaves
Supply and fix in repairs switch disconnector four pole , 415 volts 200 Amps complete all as specified and directed.
Supply and fix in repairs Copper Air termination rod 12 mm dia single pointed 300mm long along with base plate welded at bottom of termination rod, of size 10 cm long fabricated out of 32 x 6 mm thick Copper strip along with making 9mm dia for fixing in fastners complete all as specified.
Supply and fix in repairs aluminium strip 25x3 mm with saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed.
Supply and fix in repairs GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit complete all as specified and directed.
Supply and fix in repairs Porcelain insulator of existing size for isolation of conductor from the building wall upto a height of G+8 floors by providing 15cm long fastners at every 16 cm distance in the wall complete all as specified and directed.
Material and labour for general servicing of VCB of capacity 630 Amp by drawing out the VCB, removing the dust, general servicing of the mechanism such as lubricating and applying jelly, cleaning the insulators, providing new nuts and bolts etc and recaliberation of relay, remove moisture, replace unserviceable relay, batteries if any, for auxillary supply, re-installing the VCB in its original position, testing and commissioning etc complete all as specified and as directed.
Material and labour for general servicing of OCB of capacity 400 Amp by drawing out the OCB, removing the dust, general servicing of the mechanism such as lubricating and applying jelly, cleaning the insulators, providing new nuts and bolts etc and recaliberation of relay, remove moisture, replace unserviceable relay, batteries if any, for auxillary supply, re-installing the VCB in its original position, testing and commissioning etc complete all as specified and as directed.
Material and labour for General maintenance /repair of 500 KVA transformers installed at CGRA Rameswaram Sub Stations, including disconnecting the HT/LT cables, earth strips etc. from the transformer, draining the complete oil for removing sludge from the tank and removing the top cover, conservator, expulsion tank etc for detecting the leakage and repairing by welding, replacing all the gaskets & neoprene washers for leakage arresting, the HT /LT bushings if required, refill the oil, top up to required level without any extra cost, reassembling the transformer and testing etc complete all as specified and as directed.
Material and labour for General maintenance /repair of 315 KVA transformers installed at CGDHQ-4 Sub Stations, including disconnecting the HT/LT cables, earth strips etc. from the transformer, draining the complete oil for removing sludge from the tank and removing the top cover, conservator, expulsion tank etc for detecting the leakage and repairing by welding, replacing all the gaskets & neoprene washers for leakage arresting, the HT /LT bushings if required, refill the oil, top up to required level without any extra cost, reassembling the transformer and testing etc complete all as specified and as directed.
Supply and fix in repairs GOD Triple pole mechanically operated,mounted on insulator and steel frame wiht operating mechnism worked from ground level for current rating up to 200 Ams 11KV complete all as specified and directed.
Supply and fix in repairs lightining arrester high tension,expulsion type,transmission class,discharge capacity 65 Kilo Amps suitable for 11000V supply complete with all fitting suitable discharge capacity including necessary fixing arrangements made out of MS angle/flats,nuts and bolts etc complete all as specified and directed
Dehydration / filtration of transformer oils of transformer/switch gears to achive die-electric strength not less than 40kv for 1 miniute at 4mm gap as per relevent IS using portable filteration plant including testing of oil for die electric strength before and after filtration complete all as specified and directed. Note:- (i) Test results before and after filteration shall be submitted on completion in tripilicate. (ii) Necessary electricity for filtration plant shall be issued by department,required length of cable/switch etc shall be arranged by the contractor.
Supply and topping up new transformer oil into conservator tank/body tank of transformer using portable filtration plant and directected. Note:- (i) The transformer oil for topping up shall be with di electric strength more than 40kv for 1 miniute at 4mm gap. (ii) Oil shall be supplied at site in sealed barrel.
Supply and fix in repairs breather assembly suitable for out door type transformer including taking down u/s from the transformer complete all as specified.
Supply and filling silica gel inside breather assembly of transformer complete all as specified and directed.
Supply and fix danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters figures and conventional skull and bones in signal red clour and fixed with MS clamps bolts ans nuts of approved size for HT 25x20 cm size complete all as specified and directed.
Supply and fix in repairs LED Street light fitting 24 Watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP66 protection complete all as specified and as directed. Make:Cat No CLLC-SL-55-24 of CELS or equivalent in Crompton/Havells/Philips
Supply and fix in repairs LED Aviation light with enciosure of ABS material, 50 Hz, IP-40 complete all as specified and directed. Make: BGAV302LED of Bajaj or equivalent in Crompton/Havells/Philips
Material and Labour for general servicing of Diesel Engine of DG set including greasing, lubrication, calibratiuon of PT pump etc of DG sets of capacity of 75 KVA, after replacement of unservicable parts including necessary lathe work fixing, testing the DG set on full load all as directed Note: (a) All T&P items should be brought at site by the contractor. (b) Grease,lubrication are to be measure in general servicing charges of DG set and no extra cost will be paid by Deptt to the contractor. (c) Parts to be replaced shall be measured and paid separately. The makes of spares shall be of respective DG set manufacturer and as approved by Engineer in charge conforming to the OEM machine. (d) The rate quoted shall be excluding servicing of alternator & selt starter which shall be measured and paid separately under relevent items here-in-after.
Supply only cup injector suitable for DG set 75 KVA complete all as specified and as directed .
Supply only injector spring suitable for DG set 75 KVA complete all as specified and as directed .
Supply only seal 'O' ring suitable for DG set 75 KVA complete all as specified and as directed .
Supply only Barrel and Plunger suitable for DG set 75 KVA complete all as specified and as directed .
Supply only Seat injector suitable for DG set 75 KVA complete all as specified and as directed .
Supply only Valve intake suitable for DG set 75 KVA complete all as specified and as directed .
Supply only Valve Exhaust suitable for DG set 75 KVA complete all as specified and as directed .
Supply only Valve guide suitable for DG set 75 KVA complete all as specified and as directed .
Supply only Gasket Cylinder head suitable for DG set 75 KVA complete all as specified and as directed .
Supply only Gasket intake manifold suitable for DG set 75 KVA complete all as specified and as directed .
Supply only Gasket rocker lever housing suitable for DG set 75 KVA complete all as specified and as directed .
Supply only Tube water transfer for DG set 75 KVA complete all as specified and as directed .
Supply only Gasket exhaust manifold complete all as specified and as directed .
Supply only Governer weight for DG set 75 KVA complete all as specified and as directed .
Supply only Carrier weight for DG set 75 KVA complete all as specified and as directed .
Supply only Pin pivot for DG set 75 KVA complete all as specified and as directed .
Supply only generator battery lead set for DG set complete all as specified and as directed .
Dismantling the alternator of 75 KVA DG Set from its position from the foundation after disconnection of electric connection with the help of chain pully, removing the bearing with the help of bearing pullar and shifting the alternator to authorised workshop for repair and servicing complete checking of connections , terminals, lugs tightning of connections replacement of bushes complete and refixing again after in original position and proper alingment complete all as specified and directed.
Dismantling old unservicable Air cleaner elements and supply and fixing new Air cleaner elements inner and outer including dust cap suitable for 75 KVA DG Set complete all as specified and as directed .
Disconnecting and dismounting the self starter 12 Volts of 75 KVA DG Set from the engine transporting it to workshop for further dismantling for repair reassembling after repair/replacement of unservicable parts, transporting back the self from workshop to E/M installation fixing with the DG set, testing complete all as specified and as directed .
Material and Labour for general servicing at site of Diesel Engine of DG set including greasing, lubrication calibratiuon of PT pump etc of DG sets of capacity up to 160 KVA after replacement of unservicable parts including necessary lathe work fixing, testing the DG set on full load all as directed Note: (a) All T&P items should be brought at site by the contractor. (b) Grease,lubrication are to be measure in general servicing of DG set and no extra cost will not be paid by Dept tothe contractor. (c) Parts to be replaced shall be measured and paid separatly. The makes of spares shall be of respective DG set manufacturer and as approved by Engineer in charge conforming to the OEM machine. (d) The rate quoted shall be only for alternator and selt starter which shall be measured and paid separately under relevent items here-in-after.
Supply only cup injector suitable for DG set 160 KVA complete all as specified and as directed .
Supply only injector spring suitable for DG set 160 KVA complete all as specified and as directed .
Supply only seal 'O' ring suitable for DG set 160 KVA complete all as specified and as directed .
Supply only Barrel and Plunger suitable for DG set 160 KVA complete all as specified and as directed .
Supply only Seat injector suitable for DG set 160 KVAcomplete all as specified and as directed .
Supply only Valve intake suitable for DG set 160 KVA complete all as specified and as directed .
Supply only Valve Exhaust suitable for DG set 160 KVA complete all as specified and as directed .
Supply only Valve guide suitable for DG set 160 KVA complete all as specified and as directed .
Supply only Gasket Cylinder head suitable for DG set 160 KVA complete all as specified and as directed .
Supply only Gasket intake manifold suitable for DG set 160 KVA complete all as specified and as directed .
Supply only Gasket rocker lever housing suitable for DG set 160 KVA complete all as specified and as directed .
Supply only Tube water transfer for DG set 160 KVA complete all as specified and as directed .
Supply only Governer weight for DG set 160 KVA complete all as specified and as directed .
Supply only Pin pivot for DG set 160 KVA complete all as specified and as directed.
Supply and fixing in repairs Heavy duty Acid lead battery 12 volt, capacity of 180 Ah for DG set 160 KVA complete all as specified and directed. Make: Battery Model No FXP0-XP1800 of EXIDE or Equivalent in Luminous/Amron.
Dismantling the Alternator of 160 KVA DG Set from its position from the foundation after disconnection of electric connection with the help of chain pully, removing the bearing with the help of bearing pullar and shifting the alternator to authorised workshop for repair and servicing complete checking of connections , terminals, lugs tightning of connections replacement of bushes complete and refixing again after in original position and proper alingment complete all as specified and directed.
Dismantling old unservicable Air cleaner elements and supply and fixing new Air cleaner elements inner and outer including dust cap suitable for 160 KVA DG Set complete all as specified and as directed .
Disconnecting and dismounting the self starter 12 Volts of 160 KVA DG Set from the engine transporting it to workshop for further dismantling for repair reassembling after repair/replacement of unservicable parts, transporting back the self from workshop to E/M installation fixing with the DG set, testing complete all as specified and directed.
Supply only Grease of standard make complete all as specified and directed.
Supply only Lubricating oil (10W40) complete all as specified and directed. Make : Castrol/Hindustan Petroleum/Indian oil
Supply only Coolant. Make : Castrol/Hindustan Petroleum/Indian oil
Schedule of Credit (Minus) Rs. 76,000.00 NOTE: Bidder shall insert credit amount of Rs. 76,000.00 as rate in Green field under Col-13.
Jack Electrolinks Private Limited
sanjay Traders
General Engineering and Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .