| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 CrAccepted-AOC HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹6.8 Cr Quoted ₹6.9 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹8.6 Cr+₹1.7 Cr (25.4%)Rejected-Finance B 604 VASUNDHRA APARTMENTS PLOT NO 16 SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹8.6 Cr+₹1.7 Cr (25.4%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹8.6 Cr+₹1.8 Cr (25.9%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹8.6 Cr+₹1.8 Cr (25.9%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹8.9 Cr+₹2.0 Cr (29.2%)Rejected-Finance 5 P HAMILTON COURT ROAD SECTOR 27 GURUGRAM HARYANA 122009 | ₹8.9 Cr+₹2.0 Cr (29.2%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹9.1 Cr+₹2.3 Cr (33.2%)Rejected-Finance | ₹9.1 Cr+₹2.3 Cr (33.2%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹8.6 Cr
EMD Value
₹7.5 L
Closing Date
15 Apr 2024, 6:00 pmClosed
Chief Engineer Bareilly Zone
HQ Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly
ADDN ALTN CUM SPECIAL REPAIRS TO CERTAIN MD ACCN AT BIRPUR LOWER CAMP GARHI CANTT AND ANARWALA AT DEHRADUN
2024_MES_643030_1
CEBZ/DDN/T-28 of 2023-24
Open Tender
Civil Works
Item Rate
545 days
Dehradun
As per NIT
8 documents required · 8 mandatory
₹3,000
Yes
GE P Dehradun
₹7.5 L
Yes
29 Nov 2024
19 Feb 2024
22 Apr 2024
19 Feb 2024
15 Apr 2024
6 Apr 2024
19 Feb 2024 - 26 Feb 2024
Amount
BUILDING WORKS
Dismantling of asbestos cement sheets of any description (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling of steel / galvalume sheets of any description (Plain, corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling timber scantling 40 sq cm and over in section, in any position for Framed / unframed work complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises complete all as specified and directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. Laid, bedded and pointed in any mortar complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of brick work (mud brick) in mud mortar including all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Demolition of brick work in cement mortar including all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking down cement plaster of any description, thickness on brick, stone, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, removal of rubbish and cleaning, etc complete all as specified and directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc 1.50 sqm but n.exc 4.0 sqm each and removing from site including making good disturbed portions of wall with new or old bricks, lintel, cills etc in CM 1:4 complete all as specified and directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) n.exc 1.50 sqm each and removing from site including making good disturbed portions of wall with new or old bricks, lintel, cills etc in CM 1:4 complete all as specified and directed.
Taking down shutter of any description exc. 1.0 Sqm but n.exc 2.0 Sqm each and removing from site complete all as specified and directed.
Dismantling of cast iron / PVC / AC / SGSW pipes alongwith fittings and accessories upto 100 mm dia jointed in cement mortar and taking out of walls, floors or trenches, if required complete all as specified and directed.
Taking up or down 15 mm steel tubing and connections complete all as specified and directed.
Taking up or down 20 mm steel tubing and connections complete all as specified and directed.
Dismantling of water tanks capacity exc 250 ltrs and n.exc 500 ltrs complete all as specified and directed.
M&L PCC 1:4:8 type D 2, 75 mm th (using 40mm graded stone aggregate) as in floor sub base complete all as specified and directed.
M & L for 25 mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in floors, to receive surface of tile complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 400 X 400 X 7 to 8 mm thick (square/ rectangular) on floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6. Complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
M & L for non-skid coloured ceramic joint free tiles (GVT) 7 to 8 mm thick (square/ rectangular) of size 600 x 600 mm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6,complete all as specified and directed.
M & L for non-skid coloured ceramic joint free tiles (GVT) 7 to 8 mm thick (square/ rectangular) as in Skirting, riser etc (length of tiles not less than 600 mm) set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in CM 1:4 complete all as specified and directed,
M&L Glazed ceramic tiles coloured 300mmx 450mm , 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match on vertical surfaces of wall incl 10 mm thick rendering on brick surface in CM 1:4. complete all as specified and as directed.
M & L for 18 to 20 mm thick prepolished machine cut kota stone tile as in flooring incl 20 mm th cement screed base in CM 1:6 , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing and polishing. complete all as specified and directed.
All as per item no 25 but on vertical surfaces of walls as in skirting and dados incl 10mm th backing coat in CM 1:4. Complete all as specified and directed.
M & L for 16 to 18 mm thick granite(Zed Black colour as approved by GE) stone slab machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform/dado/skirting /plateform counter top WHB in cluding cutting holes for oval shape /urinal partitions etc. including 15 mm thick cement screed bed 1:6 CM in horizontal or vertical surfaces including grinding the edges half round and polishing complete all as specified and directed by Engineer-In- Charge.
M & L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection. complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified and directed.
All as per item No 29 above but except bricks complete all as specified and directed.
M & L for 15mm thick rendering in cement mortar 1:6 on brick masonary wall surfaces or on other than fair faces of brick masonary finished even and fair without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in two layers on fair faces of brick work or concrete surfaces first layer 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and second layer 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturers instructions, finished fair and even, complete all as specified and directed. Note :- water proofing compound shall be measured and paid separately.
M&L for rendering 5 mm thick in CM (1:3) on fair faces of brick work or concrete to be finshed even and smooth without using extra cement over 10 mm thick in 1:4 as dubbing coat after applying one coat of alkaline anticorrosion chemical coating having specific gravity of 1.2 to 1.22 upon exposed reinforcement as per manufacturer instruction etc complete all as specified and as directed
Taking down existing un-serviceable water proofing treatment from roof slab and cleaning the roof slab by wire brush and removing WPT felt exc 500 mtr but not exc 1.50 Km etc complete all as specified and as directed
M&L for cement concrete 1:2:4 type, B0 using 12.5 mm graded stone aggregates as in copings, roof padding/staging of water tank etc including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed Note: Work shall be carried out upto 3 storey. Rates of necessary scaffolding deemed to be include in this item
Demolition of concrete of any description and in any position not otherwise specifically provided for. Complete all as specified and as directed.
M & L for cement concrete 1:5:10 type E-2 using 40 mm graded brick aggregates as in sunken portion etc complete all as specified and as directed.
M & L for applying cement slurry over existing roof surface @ 3 Kg/Sqm incl mix with water proofing liquid @ 0.15 ltr per 50 kg cement bags as per manufactures instructions complete all as specified and directed.
M&L for rendering 10 mm thick , in cement mortar 1:4 over RCC slab, mixed using water proofing compound liquid @ 200 ml per bag of cement. Complete all as specified and directed.
M & L for water proofing treatment to RCC roof by APP based modified polymeric membrane (weight not less than 3.6 kg/sqm) as under:- (a) The surface of roof, parapet and gutters, drain mouths etc over which waterproofing treatment is to be applied shall be cleaned of all foreign matter such as fungus, moss, dust etc by wire brushing and dusting. For cast iron drain outlets a groove shall be cut around to tuck in the treatment. Concrete angle fillets shall be provided at junctions between roofs and vertical face of wall (parapet and other walls) around obstacles such as pipes chimney stacks, etc. and other similar situation to ease up about corners. (b) Primer conforming to IS: 3384-1965 @ 0.30 kg/sqm to be applied on prepared surface till the surface is properly impregnated. (c ) Apply a coat of bitumen 85/25 grade @ 1.2 kg/sqm over primed surface. (d) Over the coat of bitumen as above providing APP based 5 layer modified polymeric membrane (weight not less than 3.6 kg/sqm) unrolled and bonded completely to the substrate with side over lap of 75 mm or end over lap of 100mm. The overlaps are then sealed /fused by flame or bitumen as per manufacturer instruction. A coat of hot blown bitumen grade 85/25 @ 1.2 kg/sqm shall be applied on top of APP modfied polymeric membrane and finally it will be finished with a coat of aluminium paint @ 0.2 kg/sqm as per manufacturer instructions.
S&F factory made single extruded WPC (Wood polymer Composite) Solid moulded Flush Door Shutter of 35 mm size comprising of virgin PVC resin of K value 58-60 (Suspension Grade), Calcium Carbonate and natural Fibers (Wood Powders/ rice husk/ wheat husk) and Non toxic additives (max toxicity index of 12 for 100 gms) having min density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) &900 N (Edge) Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of class A category with property of being Termite/ Borer proof. Water/ Moisture Proof, Fire retardant and fixing with stainless steel but hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer - in- Charge, Materia test certificate and authentication should be compulsory provided by the manufacturing company.
S&F IInd class hard wood, 35mm thick factory made skeleton shutters open rebated & prepared to receive, glass, gauge etc. (without sash bars), edge of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkahts. Complete all as specified and directed.
Preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer. Complete all as specified and directed.
S & F factory made WPC single extruded 100% lead free ROHS certified board of 18mm thick pre laminated shutter for kitchen, cupboards. The laminated shutter should be pre laminated side with different design and other side plain white of density not less than 600 kg / cum manufactured by an ISO 9001:2015 certified company. The 18mm board should be 100% lead free, water proof, termite proof and borer proof and should have good screw holding capacity and complete all as specified and directed.
S & F SS cabinet handles D type size 100 mm
Supply & fixing factory made single extruded WPC(Wood polymer composite) Solid door frame/ chowkat of size 100X50 comprising of virign PVC polymer of K value 58-60 (suspension grade ) calcium corbonate and natural fibers ( wood powder/rice husk /wheat husk) and non toxic additives (max toxicity index of 12 to 100 gms) fabricated with mitred joints and applying PVC solvent cement and screwed with full body threaded star headed SS screws having min frame density of750Kg/cum screw withdrawal strength of 2200 N (face) & 1100 N edge,minimum compressive strength of 58 N/mm2, moduus of elasticity 900N/mm2 and resistance to spread of flame of class 'A' category with property of being termite / borer proof, water / moisture proof & fire retardant & fixed in postion with SS dash fasterns / hold fast of required dia and length,colour of door frame to match that of shutter all as specified and directed.
S&F factory made single extruded WPC (Wood polymer Composite) Solid moulded Flush Door Shutter of 30 mm size comprising of virgin PVC resin of K value 58-60 (Suspension Grade), Calcium Carbonate and natural Fibers (Wood Powders/ rice husk/ wheat husk) and Non toxic additives (max toxicity index of 12 for 100 gms) having min density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) &900 N (Edge) Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of class A category with property of being Termite/ Borer proof. Water/ Moisture Proof, Fire retardant and fixing with stainless steel but hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer - in- Charge, Materia test certificate and authentication should be compulsory provided by the manufacturing company.
S&F for mild steel window grills box type framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding, FE-290 grade E-165 complete all as specfied and directed.
S&F factory made steel windows (Box type) with side hung shutters precoated (colourcoated/ powder coated) with double shutters (glazed and gauged shutter bothn ) with frame complete all as specified and directed and shown on drg TD 158 sheet 1/2 & sheet 2/2 . NOTE :- Measurements shall be tken and paid compositly for frame, glazed and gauged. Grill shall be measured and paid seperately under respective item. No extra claim shall be entertained on this ground
S&F for steel ventilator (Box type) with side hung/top hung shutters precoated (colourcoated/ powder coated) with double shutters (glazed and gauged shutter both ) with frame complete all as specified and directed and shown on drg TD 158 sheet 1/2 & sheet 2/2 . NOTE :- Measurements shall be tken and paid compositly for frame, glazed and gauged. Grill shall be measured and paid seperately under respective item. No extra claim shall be entertained on this ground
S&F sheet glass ordinary quality 4mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc. .5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed.
S&F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed
S&F stainless steel tower bolt 200 mm long, complete all as specified and as directed
S&F stainless steel sliding door bolt size 250 mm long and dia 16mm with hasp, staple (bolt type) . Complete all as specified and directed by Engr-In-charge.
S&F 150 mm long stainless steel handle,complete all as specified and as directed
S&F stainless steel double legged floor door stopper 150 mm long ,complete all as specified and as directed
S&F bal catches with 8 mm dia steel ball magnet catches for cuboard shutter including strking plate as approved etc complete all as specified and as directed
S&F mild steel helical door spring 300 mm long ordinary rat tail type incl roller and roller plate complete fixed with screws to wooden frames or with welding to steel frames complete all as specified and directed
S&F in repairs stainless steel decorative curtain rod of 25 mm bore incl necessary brackets, finial etc, complete all as specified and as directed
S & F stainless steel hydraulic concealed hinge with clip on installation and integrated Silent System, opening angle not less than 100º, For shutter thickness 15 - 24 mm full overlay type shutters, hinge cup dia 35 mm including necessary fixing arrangement with stainless steel screw complete all as specified & directed.
S & F for stainless steel glossy finish hat peg set of five tier with necessary fitting complete all as specified and directed.
S&F 500 litre rotational moulded tripple layer polyethlene water storage tanks white colour (cylindrical vertical with closed top) and suitable size of MS tasla with locking system hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F 20mm ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 20 mm bore and fixed as in repair complete all as specified and as directed
M & L for cutting chases, pinning in brick/PCC blocks wall in making good to facings where required and pointing in cement mortar 1:3 and cutting chases for concealed water tubing etc and making good complete all as specified and as directed
S&F medium grade galvanized steel tubing with all fittings &fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified and as directed
S&F tubes medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified and as directed
S&F in repairs vitreous chinaware coloured wash hand basin with pedestal of size 55X40 cm complete including fancy CP wash hand basin mixer, CP brass waste coupling ,waste pipe including fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed.
S&F in repairs vitreous China corner wash hand basin, size as per manufacturer any design approved by GE including 15mm dia pillar tap, CP brass waste coupling, 450 mm long HDPE PVC connection, 750 mm long 32mm bore HDPE waste down pipe including CI brackets complete all as specified and directed.
S & F Brass CP 3 in 1 wall mixer 15 mm bore (wall mounted type) for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and as directed
S & F in repair fancy type 125mm size square brass CP shower rose with or without swivel joints complete all as specified and as directed.
S&F in repair bib tap long body fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule or fixed for 15 mm dia bore pipe complete all as specified and as directed
S&F in repair stop valves/angle valves fancy type chromium plated brass cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions fixed for 15 mm dia bore pipe complete all as specified and as directed
S&F in repair tubular towel rail 20mm dia type brass chrormium plated 600mm long between flanges complete all as specified and as directed
S&F in repair PVC connection of 45 cm length including brass nuts complete all as specified and as directed
S&F fancy type brass chromium plated soap dish of 160x160x90 mm complete all as specified and directed.
S&F fancy type glass corner 300mm radius of 6-8mm thick toughned glass with CP railing fixed with fancy type screws complete all as specified and directed.
S&F in repairs vitreous china squatting pan orissa pattern long pan size 580 mm x440mm white with spun pipe ‘P’ or ‘S’ trap, front or back inlet and foot rests excluding flushing cistern & flush pipe but incl. cement concrete bedding fixed complete all as specified and as directed
S&F in repair vitreous china wash down water closet pan (pedestal pattern) with 'P' or 'S' trap white, including seat cover, water jet and connection to drain or out going pipe and flush pipe anti symphonize pipes etc complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed.
S&F in repair for 75 mm bore out let cast iron floor trap spun pipe (conforming to IS 3989) incl cockroach trap with gratings including including jointing to waste pipe fixed in cement concrete tpe B-1 (1:2:4) etc complete all as specified and as directed
S&F in repair for 75 mm bore Cast iron spun pipe (conforming to IS 3989) soil, waste and vent pipes, in any length with or without ears with lead joints, laid in trenches or in floors or fixed to wall vertically complete all as specified and as directed
S&F in repair for 100 mm bore Cast iron spun pipe (conforming to IS 3989) soil, waste and vent pipes, in any length with or without ears with lead joints, laid in trenches or in floors or vertically cast, complete all as specified and as directed
S&F in repair 100 mm bore cast iron Bends of (any radius), spun pipe (conforming to IS 3989) diminishing piecs or tapers (larger bore measured) complete all as specified and as directed
S&F in repair 50 mm cast iron cowls spun pipe (conforming to IS 3989) complete all as specified and as directed
S&F in repair stainless steel sink with drainage board 1.00mm thick for kitchen with plug/waste pipe washers including cantiliver bracket or, connecting unions etc over all size 915 x 460mm with bowel size 410mm x 330mm x 160mm complete all as specified and as directed
S&F stainless steel plate rack of size 750mmx900mm of super deluxe model with 22 gauge steel and weight not less than 5.50 kg complete all as specified and as directed.
S&F Stainless Steel (AISI 304 grade ) non magnetic multilayer nickel chrome plated for cutlery basket,with perforated bottom & side of compacted /slots for holding cutlery of size 510x470x100mm or 520x485x100 mm or 144x 468 x50mm ( clear depth 500 mm). Complete all incl fixing of necessary telescopic channels, handels etc as required complete all as specified and as directed.
S&F for Stainless Steel (AISI 304 grade ) non magnetic multilayer nickel chrome plated for Plain basket of size 510x470x200mm or 520x485x200 mm or 486x500x200 mm .Complete all incl fixing of necessary telescopic channels, handels etc as required complete all as specified and as directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface
M&L for PCC 1:2:4 type B-2 using 20mm graded stone aggregates as in posts filling ,complete all as specified and directed by Engineer-in-Charge.
S&F MS joist channel (Fe 410-W Gde E-250 Quality A), angle or Tee section,MS tubes, flats square bars etc fixed indepently or framed or without connecting plates ,trusses etc any type framing including purlins and rafters etc confirming to Grade Fe 410-0 or Fe-310-0 complete all as specified and directed by Engr-in-Charge
S & F pre-painted galvalume aluminium zinc coated (AZ-150) GI based corrugated steel roof sheet 0.50 mm thick of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge
S & F pre-painted galvalume aluminium zinc coating GI based plain steel 0.50 mm thick for ridge cover of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge
M & L for (595 mm X 595mm) false ceiling system , using hot dipped galvanised steel section exposed surface with precoated capping, GI powerd coated tee and cross tee of size 24x32mm & 24x27mm having 0.27mm gauge at every 600mm c/c interval and wall angle of size 19x19mm having 0.35mm gauge fixed to the wall. The above grid is tobe suspended at every 1200mm c/c in both direction using 2mm thick pre-straightened GI wire laying designer tile ivory painted (high pressure steam cured) of 4 mm thickness (as per IS 14862) of size 595x595 mm and ant ine of the design (cascadev or electra) , back of the tile duly sanded and finished with a coat of protective paint over the formed grid etc complete all as specified and directed by Engineer-in-Charge.
S&F framed work as in doors or gates of angle or other section Fe 410 W Gde E 250 with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F 1.25 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete including cutting out of existing sheet if required complete all as specified and directed.
S&F 1.25 mm thick pressed steel frame of size 165 X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed
S&F 1.25 mm thick pressed steel frame of size 125 X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed
M & L for PCC 1:3:6 Type C 0 usind 12.5 mm graded stone aggregate for backing of door chawkhats complata all as specified and directed by Engr-in Charge
M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
M&L for Preparation of old steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint etc complete all as specified and as directed
M&L for three coats of white wash on ceiling on new plastered surfaces including preparation of surfaces complete all as specified and as directed
M&L for complete removal of existing treatment from wall upto plaster surface by washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper all as directed by Engr-in-charge. Note: Work shall be carried out upto 3 storey. Rates of necessary scaffolding deemed to be include in this item
M&L for applying two coats of acrylic distemper over a coat of primer, white or tinted over 0.75 to 1 mm thick wall care putty in two coat complete all as specified & directed.
Providing and applying external water proof wall putty of 1 mm thickness over plastered surface to prepare the surface even and smooth. Note: Work shall be carried out upto 3 storey. Rates of necessary scaffolding deemed to be include in this item
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Complete all as specified and directed. Note:Acrylic emulsion paint to be carried out through authorized applicator of manufacturer by mechanically operated airless spray machine with 04 year warranty of effect to be given by OEM. Work shall be carried out upto 3 storey. Rates of necessary scaffolding deemed to be include in this item
M&L for brick work with sub class ‘B’ bricks straight or curved on plan in CM 1:4 as in half brick thick walls complete all as specified and as directed
Demolition of cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided for complete all as specified and as directed
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) (nominal mix) as in slabs supported on wall, landing, balconies, canopies, deck slabs and in shelves and like in repair to Chajjas, Claddings, soffits etc including bonding agent, complete all as specified and directed. Note:- Reinforcement to be measured & paid under respective items.
M&L RCC M-25 (Design Mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed
M&L RCC M-25 (Design Mix) as in Beams, cantilevers, lintels, columns pillars, piers, posts, struts, chullah hoods, stair case,arches, domes, vaults,shell roofs, arch ribs, folded plates, slabs, balconies, canopies, deck slabs etc. or in similar articles upto 5th floor level complete all as specified and as directed
M & L for ATT post construction Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified.
M & L for ATT post construction Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified
M&L RCC M-25 (Design Mix) as in Columns, pillars, piers, posts and struts complete all as specified and as directed
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions suare/rectangular for rough finished surface
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter for rough finished surface
M&L for form work to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat, complete all as specified and directed.
M & L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
M&L for TMT Bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete incl welding etc (if reqd) all as specified and directed.
All as per item No 122 above but 6mm to 8mm.
All as per item No 122 above but but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Supply only liquid water proofing compound complete all as specified and directed.
M&L for Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M& L for 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed.
M&L heavy duty coloured parking tiles 10 to 12 mm thick dark shaded (Square / rectangular ), area of each tile not exceeding 0.36 sqm in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade, incl 15 mm thick screed bed in cement mortar 1:4. Complete all as specified and as directed.
M&L for Sand filling under floors or in foundations including watering and consolidation
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, glossy finished set and jointed in grey cement and pigment.
Surface excavation n exc 30 cm deep and averaging 15 cm and getting out in any type of soil complete all as specified.
Removing excavated material exceeding 250M but not exc 500m and depositing where directed. Complete all as specified and directed by Engineer-In- Charge.
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation / foundation of pole / laying of underground cable etc and getting out in soft / loose soil complete all as specified and directed.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated material surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified & directed.
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed by Engr-In- Charge.
M & L for providing cement concrete coping with plain fair faces including chamferes, weathering, throating etc type B0, 1:2:4 using 12.5 mm graded stone aggregate and set in CM 1:4 complete all as specified and directed.
M & L for cement concrete 1:3:6 type C-2 for 150 mm dia in concrete bed to drain pipes including packing under and haunching against the sides of pipes etc complete all as specified and directed.
M & L for reinforced concrete pipes, 150 mm dia class NP-2 laid and jointed complete with collars complete all as specified and directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150mm dia pipes complete all as specified and directed.
M & L for TMT Bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete incl welding etc (if reqd) all as specified and directed.
All as per item No 141 above but 08 mm dia complete all as specified and directed.
M & L for providing pre cast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cover slab and man hole covers etc complete all as specified and directed.
M & L for Construction of Septic Tank 50 users with brick masonry, PCC in foundation , floor, cover slab, including sludge chamber, CI vent pipe, CI cowl inlet and outlet pipe, RCC baffle wall and all necessary earthwork complete all as specified and directed. Ref. TD 217 sheet 1/7 to 7/7
M & L Soakage wells of size 3.00 m x 4.50 m complete all as shown on drawing and complete all as specified and directed. Ref. TD 309 sheet 1/4 to 4/4
M & L PCC 1:3:6 type C0 (using 12.5 mm graded stone aggragate) as in surface channel drain. Complete all as specified and directed
M & L for Desludging / desilting of 150 mm dia sewage lines including manholes, up to 2.0 m depth by removing blockage if any by means of rodding manually or mechanically by pumping out water where required and removing residual silt / mud / peat / sludge out side of defence land complete all as directed. Note: Work of sewage disposal has to be carried under foul condition, hence the rate to be deemed included.Nothing extra shall be paid to the contractor on this account
M & L for rendering 15 mm thick in CM 1 : 4 on fair faces of brick masonry or concrete surface ,finished even and smooth without using extra cement complete all as specified and directed.
M & L applying two coats of cement based paint over a coat of primer on new plastered surface incl preparation of surfaces complete all as specified and directed.
S & F mild steel angles, tees, flats, C section, MS square bars, MS Tubes etc as in steel gates, steel posts and struts in fencing, grills including embedding in concrete and screwing etc. including cut to shape as directed, drilling holes, notching for wire etc including all necessary drilling, bolting, welding or riveting and similar work conforming to FE-290 Gde E-165 complete all as specified and directed.
Supply only Chain link MS Galvanised fencing any size or type complete all as specified and directed.
S & F 2mm thick fibre glass reinforced translucent corrugated / plain sheeting with two corrugated side lap fixed with coach screws and washers in roof, wall etc complete all as specified and directed.
Fixing only Chain link fencing including line wires,any mesh,size and type to any type of standard, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply and laying in replacement pipe galvanized, “Medium class”, including fittings 40 mm dia all as specified and directed by Eng-in-charge.
Supply and laying in replacement pipe galvanized, “Medium class”, including fittings 25 mm dia all as specified and directed by Eng-in-charge.
Supply and fix in replacement Gun-metal, globe or gate valves confirmung to IS 9338 , 40 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in replacement Gun-metal, globe or gate valves confirmung to IS 9338 , 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Drilling and tapping from existing CI/DI (in position) for branch connections upto 40mm internal dia.
M&L for construction of brick masonry valve pit of following internally size 600mm x 600mm x 600mm with angle iron 25mm x 25mm x 4mm frame and 2mm thick mild steel plate cover painted with two coats of synthetic enameled paint over a coat of red oxide primer after preparation of surface including locking arrangement, including necessary excavation and earth work 75 mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate over 100 mm thick hard core using broken in foundation/base floor, brick work in cement mortar (1:6) in one brick thick wall and 15mm thick cement plaster in cement mortar 1:4 on internal surface of walls and outside upto 150 mm deep below ground level complete all as specified and directed at site.
Taking down carefully copper / Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls / floors etc complete all as specified and directed.
M & L point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in existing concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with modular metal frame and polycarbonate top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed of the following. (Note: Colour code shall be maintained as per IE rule) ( Rates of modular metal flush box, plate and frame shall be inclusive in the quoted rate.)
(a) One light point point /bell buzzer point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
(e) One light point controlled by two way switch
All as per item No 161 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm. compete all as specified and directed
M &L for new point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings with cutting chases and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note:(i) Colour code shall be maintained as per IE rule (ii) Cutting chases on Brick/and Stone masonery for concealed conduit wiring not exc. 10cm girth etc and making good surfaces with CM 1:3 deemed to be included in the rate.) ( Rates of modular metal flush box, plate and frame shall be inclusive in the quoted rate.)
(a) One light point point / bell buzzer point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
All as per item No 168 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm complete all as specified and directed.
S&F Modular switch 1 way 6A,1 Module SP 230 V AC complete all as specified & directed.
S&F Modular switch 1 way 16A,1 Module SP 230 V AC complete all as specified & directed.
S&F Modular switch 2way 6A,1 Module SP 230 V AC complete all as specified & directed.
S&F Modular Socket,6A-2/3 pin combined,2 Module 230 V AC complete all as specified & directed.
S&F Modular socket outlet two in one three pin 5 Amp and 15 Amp flush type complete al as specified.
S&F Modular Bell switch 6 Amp,1 Module complete all as specified.
S & F ding dong bell AC 230 V single pole complete all as specified & directed.
BLANK
S & F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC complete all as specified & directed.
S & F lamp holder PVC / polycarbonate type with back plate suitable for batten fittings.250 V AC complete all as specified & directed.
M & L in replacement sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings with chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 6.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed including taking down old sub main wiring. Note: (1) Cutting chases on Brick / and Stone masonery for concealed conduit wiring not exc. 10cm girth etc and making good surfaces with CM 1:3 deemed to be included in the rate.) (2) Two runs of 6 sqmm cable, one run of copper cable 6 sqmm and one run of PVC conduit 20mm shall be measured as one unit.
Supply & fixing in replacement and Testing TP & N Vertical load line (VTPN) 4 way 415 Volts 50 Hz indoor type double door sheet metal enclosure IP-43 DB's IK-09 flush mounted with 250 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable management including Provision of MCCB 63 Amps,ICs=100%ICu, 16KA four pole as in comer including connecting terminal strip complete and SP MCBs as out going etc complete pre wired with suitable size copper conductor. The DB's shall hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed including taking out old unserviceable DB and removing from site. (Note :- DBs/MCCBs/ MCBs shall be of same make)
S & F in replacement sheet metal enclosures 240 volt with 200 amps rated copper bus bar for double door 8 way IP-43DB's lk-09 suitable for one MCB SPN as incoming and 6 MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed, including taking down old unserviceable DBs . (MCBs shall be measured and paid separately).
S & F MCB double pole 240 Volt 10 KA 40-63 Amp 'C' series conforming to ISI marked complete all as specified & directed .
S & F MCB single pole and 240 volt 10 KA 5-32 Amp 'C' series conforming to ISI marked all as specified and directed .
S & F MCCB 415 Volt 16 KA 4 pole 63 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed.
Supply & fix in replacement LED light fitting 1x20 W,220V AC decorative box type with driver ,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply & fix new LED light fitting 1x20 W,220V AC decorative box type with driver ,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F LED light fitting mirror type with high out put diffuser 2 feet ,10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed..
S & F LED light fitting decorative wall mounting cast aluminium Polycarbonate paint bracket suitable for 5 watts LED bulbwith frosted glass with and including One No 5 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S & F high efficiency LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS and CFL direct fit in holder complete all as specified and directed.
S & F ceiling fans complete with blades ,down rods ,electronic regulator and accessories ,230 V ,1200mm sweep.Min air delivery 210 CFM with service value 6.00 BEE Five Star Rated with Brush less Direct Current (BLDC) Motor complete all as specified and directed.
Supply and fix water heater storage type steel body with glass line coating inner tank ABS outer body and heating element upto 2 KW, capacity 25 ltr, ED temp indicator and BEE 5 star rated complete with all accessories such as safety valve, thermostat, NRV connection pipe etc complete all as specified and directed.
Supply & fix exhaust fans steel body AC single phase 230 V of size 300 mm sweep with blades ,frame and louvers including M&L for making circular holes of suitable size in walls and making good disturbed surfaces to match with the existing surfaces complete all as specified and directed.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 4 mm dia GI earth lead wire as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed.
Supply and Fixing in replacement Integral LED Street Light Luminaire comprising of high pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 40/45 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours including GI brackete made out of 25 mm GI pipe medium grade and MS clamps for fixing of light fitting complete and connected with twin core PVC insulated copper flexible cable with existing point all as specified and directed
Supply and Fixing in replacement Integral LED Street Light Luminaire comprising of high pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 25 Watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours including GI bracket made out of 25 mm GI pipe medium grade and MS clamps for fixing of light fitting complete and connected with twin core PVC insulated copper flexible cable with existing point all as specified and directed..
Supplying, laying in replacement jointing and testing LT underground cable of size 16 sqmm 4 core heavy duty, 1100 volts PVC insulated and sheathed, armoured with multi stranded aluminium conductor cable confirmung to latest IS, laid in trenches / ducts or fixed to poles / walls or laid under roards / paths / drains / culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable duly insulated 1.1 KV grade heat shrinkable sleeve including cable gland and lugging etc at both ends all complete all as specified and directed. Note Excavation, earthwork, cable sand cushioning & cable protection shall be measured seperately under relevant items.
All as per Item No 201 above but of size 25 sqmm 4 core complete all as specified and directed.
S&F LED light fitting 1x9W/1x10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete.
Taking down and refixing energy meter fixed in walls/panels of any capacity/any type after carefully disconnecting electrical connections all as specified and directed by Eng-in-charge. Note:- Quoted rate shall deemed to be inclusive of following parameters:- (a) Meter reading shall record shall be submitted before and after replacement duly signed by the contractor rep and MES rep. (b) Old meter should be handed over to MES rep/or in written custody of the Contractor. (c) Any rejoining wires/cables shall be done using suitable ferrule/cable connectors after removal of meter.
M & L for laying local dry clean sand filling cushioning in trenches around under ground cable complete all as specified and directed.
M & L for laying well burnt brick, old size in trenches, as protection of underground cable complete all as specified and directed.
M&L for two coats of white wash on ceiling on old plastered surfaces including preparation of old decorated surfaces complete all as specified and as directed
S&F brass CP sink Mixer 15mm bore (wall mounted type) for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and as directed.
Note : Tenderers may note that amount of credit Rs 9,65,088.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
Pooja Singla Builders And Engineers Pvt Ltd (BID ID -2978226)
Sudhir Sharma Associates (BID ID -2980335)
Inderjit Mehta Constructions Pvt Ltd (BID ID -2980315)
AMIT ASSOCIATES (BID ID -2980856)
P K CONSTRUCTION CO. (BID ID -2980953)
SAWHNEY BUILDWELL LLP (BID ID -2978138)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .