Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAdmitted-Finance 11 492 IRIMPANAM TRIPUNITHURA ERNAKULAM KERALA 682309 | ERNAKULAM | KERALA | 682309 | L1 | Admitted-Finance | |
| 2 | L2₹19.5 L+₹1.1 L (5.99%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹19.9 L+₹1.5 L (8.28%)Admitted-Finance 3 333 F M P ARCS VAZHAKULAM P O VENGACHUVADU ERNAKULAM KERALA 686670 | ERNAKULAM | KERALA | 686670 | L3 | Admitted-Finance | |
| 4 | L4₹19.9 L+₹1.5 L (8.28%)Admitted-Finance 58 667 SAPTHATHI BUILDING KONTHURUTHY THEVARA ERNAKULAM KERALA 682013 | ERNAKULAM | KERALA | 682013 | L4 | Admitted-Finance | |
| 5 | L5₹21.1 L+₹2.6 L (14.4%)Admitted-Finance T C NO 26 1461 1 SL ELECTRICAL WORKS S L TOWER UR 43 UPPALAM ROAD STATUE UPPALAM ROAD THIRUVANANTHAPURAM KERALA 695001 | THIRUVANANTHAPURAM | KERALA | 695001 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | LAMOS TECHNOLOGY SOLUTIONS PVT LTD L7 | Nev Tech L4 | NATIONAL ENGINEERING COMPANY L1 | Power Care Electrical L6 | Linsta Services L3 | SL ELECTRICAL WORKS L5 | DIAMOND ENGINEERING WORKS L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00WIRING IN STEEL & PVC CONDUIT | ||||||||||
| 1.10Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. | ||||||||||
| 1.11 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire | 400 | Metre | 1,199 ₹4,79,600 | 1,205 ₹4,82,000 | 1,090 ₹4,36,000 | 1,370 ₹5,48,000 | 1,180 ₹4,72,000 | 900 ₹3,60,000 Lowest | 1,300 ₹5,20,000 |
| 1.12 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire | 400 | Metre | 1,571 ₹6,28,400 | 1,560 ₹6,24,000 | 1,550 ₹6,20,000 | 1,850 ₹7,40,000 | 1,540 ₹6,16,000 Lowest | 1,550 ₹6,20,000 | 1,550 ₹6,20,000 |
| 2.00MCCB, MCB & DB'S | ||||||||||
| 2.10Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board/MCCB DB including drilling holes in cubicle panel, making connections, etc. as required. | ||||||||||
| 2.11 | 100 A,30KA,FPMCCB | 3 | Each | 15,250 ₹45,750 | 10,620 ₹31,860 | 8,580 ₹25,740 Lowest | 11,000 ₹33,000 | 16,500 ₹49,500 | 9,800 ₹29,400 | 10,000 ₹30,000 |
| 2.12 | 125 A,36KA,FPMCCB | 3 | Each | 22,498 ₹67,494 | 11,800 ₹35,400 Lowest | 14,200 ₹42,600 | 13,000 ₹39,000 | 16,500 ₹49,500 | 11,850 ₹35,550 | 12,000 ₹36,000 |
| 2.20Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.) | ||||||||||
| 2.21 | 8 way (4 + 24), Double door | 16 | Each | 16,987 ₹2,71,792 | 11,800 ₹1,88,800 Lowest | 11,850 ₹1,89,600 | 13,500 ₹2,16,000 | 14,520 ₹2,32,320 | 12,100 ₹1,93,600 | 12,900 ₹2,06,400 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
7 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
Incoming feed maintenance of Department Building
2025_NITC_890313_1
Engg/EMU/TA-3/25-26/0002/DB Rewiring-P1
Open Tender
Electrical Works
Item Rate
120 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹40,000
Yes
13 Feb 2026
17 Dec 2025
9 Jan 2026
17 Dec 2025
7 Jan 2026
17 Dec 2025
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
MCCB, MCB & DB'S
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board/MCCB DB including drilling holes in cubicle panel, making connections, etc. as required.
100 A,30KA,FPMCCB
125 A,36KA,FPMCCB
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
Supplying and fixing 40-63A , Four pole, 430 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc. as required..
Supplying and fixing 40-63A , Triple pole, 430 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 3 phase 6 way, double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB)
Supplying and fixing 3 phase 8 way, double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB)
EARTHING
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
MV CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 35 sq. mm (32mm)
4 X 50 sq. mm (35mm)
COPPER STRAND SWG
Supply and laying of one number of 8 SWG good quality bare copper wire for loop earthing along with existing XLPE insulated aluminium cable as required.
UG CABLES
Supply of 1.1 kV grade 4C x 35 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable etc. as required.
Supply of 1.1 kV grade 4C x 50 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable etc. as required.
Charges for removing the old wall mounted DB including MCBs, RCCB and other accessories without any damage, making good the damages of the wall/ floor including painting, and conveyance of the material to the godown and etc, as required
Charges for removing the existing Cable with Copper, wire with conduit and other accessories without any damage, making good the damages of the wall/ floor including painting, and conveyance of the material to the godown and etc, as required
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_935802.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .