Loading…
Loading…
Tender Value
₹11.1 Cr
EMD Value
₹22.1 L
Closing Date
15 Oct 2026, 3:00 pm
Yes (up to 2 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
SNT
2 conditions · 2 needing a document upload
As per Tender Document.
As per Tender document.
3 conditions
As per tender document all supporting document need to be uploaded.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
SIGNAL & TELECOM MAINTENANCE WORK, REPLACEMENT/REFIXING WORKS INCLUDING SUPPLY OF MINOR SPARES AND TOOLS FROM UNCHDIH TO NEW CHIRAILAPATHU SECTION & SONNAGAR LINK TO NEW SONNAGAR JUNCTION SECTION OF EASTERN DEDICATED FREIGHT CORRIDOR(EDFC) FOR TWO YEARS.
DFC-DDU-SNT-SSTMC-2026-01~EDFC
DFC-DDU-SNT-SSTMC-2026-01
Open
Works - General
24 Months
Chandauli, Uttar Pradesh
₹11,800
₹22.1 L
24 Sept 2026
24 Sept 2026
1 Oct 2026
93 items across 10 schedules · ₹10,53,02,352.56 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal soil/strata (including soft rock), conforming to distances as per cable route plan and refilling and ramming of loose soil. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on DFCCIL and instructions of DFCCIL Engineer at site. In case the full depth is not available, there shall be proportionate payment but only after the approval of minimum APM/ DyPM officer. | Metre | 29900.00 | 97.21 | 29,06,579 |
| 2 | Laying of HDPE duct as per the approved cable route plan in the excavated trenches/other protected works/RCC channel etc. including all accessories like end caps, collars, bends, couplers etc. The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings no. RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8(a) respectively, issued vide Chapter XIII of the Telecomm Manual. Note: There are 2 HDPE in each Trench- T1 & T3. Laying of 2 HDPE ducts in same trench will be considered as one unit of the work | Kilometre | 25.00 | 8,573.55 | 2,14,338.75 |
| 3 | Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes laying of cables in track crossings & road crossings. (Cables will be meggered before and after its laying by contractor under supervision of DFCCIL Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | Metre | 73570.00 | 7.46 | 5,48,832.2 |
| 4 | Blowing/drawing of OFC cable in the HDPE pipe duct already provided in the trench and protective work. The cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the DFCCIL engineer at site. All the equipments/machinery required shall be arranged by the contractor. | Kilometre | 25.00 | 18,644.9 | 4,66,122.5 |
| 5 | Supplying and placing of one layer of quality bricks of standard size and of 'B' grade of the local make and spreading on cables laid. (minimum size of brick 200mm X 100mm X 70mm) | Numbers | 179100.00 | 4.71 | 8,43,561 |
| 6 | Cross trench for identification of the route of existing Signalling and Telecom cables. | cum | 440.00 | 316.42 | 1,39,224.8 |
| 7 | Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and concreting it afterwards as per original condition. In hard rocky ground area, cables will be laid normally on layer of soft earth of 0.05 mtrs thickness previously deposited at bottom of the trench. The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no. SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. | Metre | 1035.00 | 173.1 | 1,79,158.5 |
| 8 | Horizontal direction drilling (HDD)/Trenchless digging/machine drilling without damage to surface road /track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road.Note: - DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore. | Metre | 13420.00 | 699.9 | 93,92,658 |
| 9 | Laying and fixing of medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The laying and fixing to be done as per RDSO drawings no. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest | Metre | 255.00 | 394.07 | 1,00,487.85 |
| 10 | Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note: - DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore. | Metre | 1000.00 | 1,121.65 | 11,21,650 |
| 11 | Cement concrete work for miscellaneous unscheduled items in ratio 1:3:6. Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). The aggregate cement and sand will be supplied by contractor. | cum | 31.00 | 5,412.26 | 1,67,780.06 |
| 12 | Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides of bricks with thickness 20 mm each end with contractor's own 'B' Class bricks. I t also includes excavation, grouting, bolting etc. wherever required. 'B' Class bricks, sand and cement (ISI mark) will be supplied by the Contractor. | cum | 74.00 | 2,211.84 | 1,63,676.16 |
| 13 | Supply of 24 fiber optical fiber cable straight joint enclosure (SJC) complete with all accessories along with enclosures with heat shrinkable splice protection sleeve as per RDSO spec. RDSO/SPN/TC68/2014 Revision 1.0, Amndt.1.0 or latest. Splice losses in no case should be more than 0.1 dB. | Numbers | 182.00 | 6,000.94 | 10,92,171.08 |
| 14 | Splicing of 24 core optic fibre cable and making the splicing joint with contractor's own machine and tools. Joint should be prepared in such a way that the top of the enclosure should be at a depth of minimum 1.2 mtr. and the enclosure should be covered with soft soil and bricks. Splice loss of each fibre should be within acceptable limits, preferably 0.05 dB. | Numbers | 82.00 | 13,089.82 | 10,73,365.24 |
| 15 | Supply of thermo shrink jointing kit as per RDSO Specn. No. IRS: TC 77-2012 (Rev.3.0) with (Amdt. -1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer | Numbers | 70.00 | 3,663.65 | 2,56,455.5 |
| 16 | Supply of Half Split Double Walled Corrugated (DWC) Pipe/ duct with associated collars etc. 6 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia.as per RDSO Specification No. RDSO/SPN/204/2011. (Consignee Inspection) | Numbers | 100.00 | 252.88 | 25,288 |
| 17 | Installation of thermo shrink jointing kit as per RDSO Specn. No. IRS: TC 77-2012 (Rev.3.0) with (Amdt. -1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer. | Numbers | 20.00 | 1,867.58 | 37,351.6 |
| Schedule total | ₹1,87,28,700.24 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument.pdf
ATTACHMENT
NITofMaintenanceContract_1.pdf NIT of Maintenance Tender
ATTACHMENT
GCC2022.pdf
ATTACHMENT
NITofMaintenanceContract_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .