Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC 179 THE MALL AMBALA CANTT 133001 HR | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹41.0 L+₹3.1 L (8.29%)Rejected-Finance | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹41.6 L+₹3.7 L (9.85%)Rejected-Finance | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹42.8 L+₹5.0 L (13.1%)Rejected-Finance | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹43.8 L+₹6.0 L (15.8%)Rejected-Finance | L5 | Rejected-Finance Rejected being |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
18 Apr 2022, 6:00 pmClosed
GE(NORTH) AMBALA CANTT
GE(NORTH) AMBALA CANTT
CA NO GE(N)AMB-74/2021-22 SPECIAL REPAIR TO GOVT MD ACCN BLDG NO 230 (11 QTRS) AT ABDUL HAMID LINE UNDER AGE B/R-II OF GE (N) AMBALA CANTT
2022_MES_510255_2
GE(N)Amb-74/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE(NORTH) AMBALA CANTT
As per tender documents
8 documents required · 8 mandatory
₹500
GE(NORTH) AMBALA CANTT
₹89,000
Yes
11 May 2022
29 Mar 2022
20 Apr 2022
29 Mar 2022
18 Apr 2022
5 Apr 2022
29 Mar 2022 - 5 Apr 2022
Amount
Schedule 'A' Part-I (B/R itmes) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregates as in sub base of floor and finished even and fair to receive tiles etc. complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/skirtings/dados of size 450x350x7mm thick or nearest size, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectangular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/ rectangular) 7 to 8 mm thick, cut from tiles of area of each tile exc 0.11 sqm but not exc 0.18 sqm as in skirting, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut baroda Green marble stone slab 18 to 20 mm thick in kitchen cooking platform and jointed in grey cement slurrry mixed with pigment to match the shade of the slab incl cutting, rubbing and polishing over and including 15 mm thick cement screed bed in CM 1:6 and half rounding the edges of stone slab (stone slab shall fixed in one piece upto lenght of 1.80 metre and in two piece in case the lenght of cooking plateform is more than 1.80 metre) complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut kota stone slab flooring 18 to 22 mm thick of size not less than 550mm x 550mm in floor, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut kota stone slab flooring 18 to 22 mm thick in treads of stair case , set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge. Note :- (i) The size of the kota stone shall be in one piece for each tread of stair case. (ii) Front edge of kota stone shall be half rounded and quoted rate of this item shall be deemed to be included this element.
M & L machine cut kota stone slab flooring 18 to 22 mm thick in riser of stair case/skirting , set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge. Note :- (i) The size of the kota stone shall be in one piece for each riser of stair case and for remaining location, size of kota stone shall not be less than 550mm x 550mm .
Demolition of reinforced cement concrete in roofs, floors, beams, chajjas, staircases, landings and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete 1:1-1/2:3 (Nominal Mix) using 20mm graded crushed stone aggregates as in chajjas and the like complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete 1:1-1/2:3 (Nominal Mix) using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases in brick walls ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting exc 10 cm and not exc 20 cm girth complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits of suspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 CM thick (horizontal or sloping) flat for rough finished surfaces of concrete , complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide, for rough finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge
M & L formwork to chajjas and similar items including edges for rough finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks old size in half brick thick wall straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Taking down loose plaster from ceiling of slab, edges and soffit of chajjas and the like, cleaning surface with wire brush to remove all dust/dirt/loose particles to expose old steel reinforcement, applying neat cement slurry@ 3Kg per sqm and 30mm thick (in two layers , each layer 15mm thick) plaster in cement mortar 1:3 not exc 5 sqm each patch including removal of rubbish/demolished material to a distance exceeding 250mtr and not exc 500mtr , including scaffolding upto 3m height and applying two coats of cement base paint complete all as specified and as directed by Engineer-in charge .
Taking down loose plaster from ceiling of slab, edges and soffit of chajjas and the like, cleaning surface with wire brush to remove all dust/dirt/loose particles to expose old steel reinforcement, applying neat cement slurry@ 3Kg per sqm and 30mm thick (in two layers , each layer 15mm thick) plaster in cement mortar 1:3 not exc 5 sqm each patch including removal of rubbish/demolished material to a distance exceeding 250mtr and not exc 500mtr , including scaffolding 3m to 7m height and applying two coats of cement base paint complete all as specified and as directed by Engineer-in charge .
Taking down loose plaster from ceiling of slab, edges and soffit of chajjas and the like, cleaning surface with wire brush to remove all dust/dirt/loose particles to expose old steel reinforcement, applying neat cement slurry@ 3Kg per sqm and 30mm thick (in two layers , each layer 15mm thick) plaster in cement mortar 1:3 not exc 3 sqm each patch including removal of rubbish/demolished material to a distance exceeding 250mtr and not exc 500mtr , including scaffolding up to 3m height and applying three coats of white lime wash complete all as specified and as directed by Engineer-in charge .
M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
M&L rendering 15 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:4 and finished even and fair without using extra cement but using water proofing compound @ 2% by weight of cement or as per manufacturer's instructions complete all as specified and as directed by the Engineer-in-Charge. (water proofing compound shall be measured and paid for separatally)
M&L rendering 15mm thick in cement mortar 1:6 on any faces of brick work or concrete wall surfaces and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in charge.
M&L rendering 5 mm thick on fair faces of brick work or concrete ceiling or chajjas surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Supply only water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing new plastered surfaces and applying two coats of cement based paint over a coat of alkali resitant primer on surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing new plastered surfaces and applying two coats of oil bound distemper with painting roller over a coat of alkali resistant primer over and including 1 to 2 mm thick wall care putty white cement based in two or more coats to achive smooth surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete wall and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of old decorated brick/concrete, plastered / un--plastered surfaces of walls by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of exterior acrylic emulsion paint with painting roller over prepared surfaces of wall, pillar, cornices complete all as specified and as directed by the Engineer-in-Charge.
Dismantling Brick tiles or terracing tiles, single layer on roofs complete all as specified and as directed by the Engineer-in-Charge.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) of any description and any position not otherwise specifically provided for complete all as specified and as directed by the Engineer-in-Charge.
Taking down old tar felt including plaster from roof and removing the same from site complete all as specified and as directed by the Engineer-in-Charge.
M & L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, and applying neat cement slurry @3 Kg/Sqm complete all as specified and as directed by the Engineer-in-Charge.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed by the Engineer-in-Charge.
M & L providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in padding on roof and finished even and smooth without using extra cement including form work where ever required complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 10 mm thick on roof surfaces in cement mortar 1:4 and finished even and fair without using extra cement but using water proofing compound @ 2% by weight of cement or as per manufacturer's instructions complete all as specified and as directed by the Engineer-in-Charge. (water proofing compound shall be measured and paid for separatally)
M & L providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof kerbs, mud stops and finished even and smooth without using extra cement inlcuding form work where ever required complete all as specified and as directed by the Engineer-in-Charge.
M & L cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shall be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shall be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
M & L precast cement concrete tiles of size 25cm x 25 cm x 22mm thick machine pressed laid on screed bed and joints grouted flush in CM (1:3) mixed with 5% crude oil by weight of cement including screed bed 15 mm thick in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel door shutter two leaves with frame of 20 gauge MS sheet (all around) and leaves of 21 gauge MS Sheet ( all as per Godraj Pettern) with 03 Nos. hinges per shutter three way locking arrangement with brass lock with duplicate key and CP handle including two coats of spray painting over a coat or red oxide primer complete fixed in existing cupboard fixed with necessary nuts, bolts including embedded in PCC 1:2:4 (area of opening shall be measured) complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete in existing sunken floor etc and removal of the same to a distance exceeding 250 mtr and not exceeding 500 mtr, depostied where directed complete all as specified and as directed by the Engineer-in-Charge.
M&L providing sunken floor water proofing treatment comprising of the following :- (a) Scrapping the surface with wire brush and cleaning with water and allow to dry. (b) Applying cement slurry @ 1.2 kg/sqm duly mixed with water proofing compound @ 2% by weight of cement or as per manufacturer's instructions. (c) 15 mm thick cement plaster in CM 1:3 mixed with water proofing compound @ 2% by weight of cement or as per manufacturer instruction ( the corners will be made round in concave shape) and finished even and fair without using extra cement. (d) Applying cement slurry @ 1.2 kg/sqm duly mixed with water proofing compound @ 2% by weight of cement or as per manufacturer's instruction. (e) Applying one coat of hot blown bitumen grade 85/25 confirming to IS-702 @1.20kg/sqm (f) Providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt using butane gas torch and ceiling all joints. (g) Applying one coat of hot blown bitumen grade 85/25 confirming to IS-702 @1.20kg/sqm.
M&L PCC 1:5:10 type E-2, using 40 mm graded crushed stone aggregate as in filling in sunken floor, rounded or chamfered on edges complete all as specified.as directed by the Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 250 ltr and not exc. 500 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge.
S & F 500 Litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by the Engineer-in-Charge. Note : Water storage tank shall be White in colour.
S & F 20 mm bore Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed (minium weight-210 grm) complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases in brick walls ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified & directed by the Engr-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
M&L for concrete bed to drain pipes of bore 110mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports complete all as specified and as directed by the Engineer-in-Charge. Note:-(i) Thickness of bed belew barrel of pipe -10 cm (ii) Width of bed :- outer dia of pipe plus 30 cm.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing of excavated material to a distance not exc 50 m and depositing at a level not exc 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) juction single (Single T) equal are unequal complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed by the Engineer-in-Charge.
S&F kitchen plate rack of stainless steel sheet 1mm thickness size 900mm x 900mm x250mm and having weight not less than 8.00 Kg each as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 mm wide with chromiun plated brackets guard and railing 60 cm long as in reapir complete all as specified and as direced by the Engineer-in-charge.
S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws as in repair complete all as specified and as directed by the Engineer-in-Charge
S & F sinks with drainage board made out of stainless steel 1mm thick sheet for kitchen with plugs, waste pipe, brass chromium plated coupling and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm as in repair complete all as specified and as directed by the Engineer-in-Charge
S & F as in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy fancy type chromium plated angular stop valves screwed down, high pressure with crutch handle, scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore fancy type cast copper alloy chromium plated stop valves with long shank and cup (concealed type), screwed down, high pressure with crutch handle, scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F bib taps 15mm bore fancy type brass chromium plated with long body and crutch handle screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair grating doom 100mm dia of PTMT (min weight 25gms) complete all as specified and as directed by the Engineer-in-Charge.
S & F fancy type pillar tap of 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F aluminium hat pegs, solid body, 125mm to 175 mm complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated shower rose 100 mm dia with or without swivel joint with arm of standard size as per site as in repair complete all as specified and as direced by the Engineer-in-charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest and PVC (SWR) 'P' or 'S' trap of pressure rating 6 Kg/ sqcm complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm, fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 32 mm bore Low density polyethylene pipes (LDPE)of pressure rating 6kgf/Sq cm of standard length suitable for WHB and sink as in repair complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exc 1.5 sqm but not exc 4 sqm each and removing the same from site complete all as specified and as directed by the Engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutter from the frames) area n. exc 1.5 Sqm each and removal from site complete all as specified and as directed by the Engineer-in-Charge
M & L PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in holdfasts complete all as specified and as directed by the Engineer-in-Charge.
S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of boarding of any type/size as in cup boards/ wardrobes including harware complete all as specified and as directed by the Engineer-in-Charge.
S&F 18mm thick lead free PVC celuka ply of both side plain of approved colour other than white colour fixed with screws solvent cement / adhesive to make kitchen / bed rooms cabinet sides, top and bottom and shelves inside the cabinets complete all as per manufacturer's specifications/ instructions complete all as specified and as directed by the Engr-in-charge.
S & F Continuous (piano) hinges, width of flaps 30mm mild steel, bright finish or electro galvanised complete all as specified and as directed by the Engineer-in-Charge.
S&F 100mm long fancy type Brass handles, cast type, polished bright complete all as specified and as directed by the Engineer-in-Charge.
S&F magnet catcher fixed in cabnet shutter (one portion) and wooden frame (other portion) with screw complete all as specified and as directed by the Engineer-in-Charge.
S&F 100 mm long brass barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel pipe 20 mm dia having wall thickness 1.6mm fixed with and including stainless steel brackets in cup boards as in hanging rod , two lotto for each road length at both end etc complete all as specified and as directed by the Engineer-in-Charge.
M&L rolled mild steel framed work as in chowkats of door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing conforming to Fe-410-W(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube and fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M. S. tubes for top & bottom rails. M. S. frame shall be covered with heat moulded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
M & L framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed balusters; walk ways, railings, framework of water tanks and similar work con- forming to Fe-290. Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by Engineer in Charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill fabricated from 10mm square bar as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately.
S&F box type using ERW hollow 'P' section ventilators glazed/ gauged including MS grills of square bar 10 mm @ 100 mm c/c complete with glazing bars dovetailed or welded, including two coat of synthetic enamel ordinary tint paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new wooden surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new steel and iron surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
S & F brass, wire type gate and shutter hooks and eyes 75mm complete all as specified and as directed by the Engineer-in-Charge.
S&F stainless steel wire cloths 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staple complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 3.0mm thick ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed by the Engineer-in-Charge.
Supply only stainless steel butt hinges 50mm long medium weight complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 4mm thick frosted on one side ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing 250mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel butt hinges 100mm long medium weight complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel curtain rod 25mm dia having wall thickness 1.6mm fixed with and including stainless steel decorative brackets, two lotto for each road length at both end etc complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel 150 mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and as directed by the Engineer-in-Charge.
Surface excavation not exceeding 30cm deep and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavation over area , not exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc 63mm , deposited , spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M & L plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork for rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L machine pressed rubber moulded precast coloured concrete interlocking paver block, any shape and size conforming to IS 15658-2006, ISI marked of 80 mm thickness, grade M-40 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed by the Engineer-in-Charge.
M & L second class hard wood plain fillets square, rectangular or triangular in section of cross sectional area exceeding 13 Sqcm and not exceeding 25 Sqcm clean sawn, secured with nails or brads complete all as specified and as directed by the Engineer-in-Charge.
S & F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'A' Part-I (E/M itmes) Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 136 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 136 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring with 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 2/3 pin combined, 6amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 3/5 pin combined, (5pin), 6/16amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F modular bell push 6 Amp, 1 way, 1 module, 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
S&F of electronic Fan regulator modular 120 watt, 2 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
S&F LED batten light fitting 9/12 watt, one feet, 6500K aluminium housing and electric driver including tube rod cold/ warm type including connecting with copper conductor flexible cable from ceiling rose to connector of the light complete including removing unserviceable items all as specified and as directed by the Engineer-in-Charge.
Supply and fixing indoor decorative LED tube light fitting box type with opal diffuser, high efficient PVC housing body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 18/20 Watt LED tube rod luminaries environment friendly, connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED surface mounted bulk head luminaries 8-10 W with min 800 lumen, industrial model, IP 65, Aluminum housing, surge protection including driver & LED lamp etc complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply & fix calling bell ding dong 230 volt including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 08 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix MCB SP, 6-32 Amps, 240 volt,10 KA , 'C' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN, 40 Amps, 240 volt,10 KA, 'C' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
S&F LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete including taking down unserviceable bulbs complete all as specified and as directed by the Engineer-in-Charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old U/S fitting complete all as specified and as directed by the Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA, 'C' curve complete all as specified and as directed by the Engineer-in-Charge.
S & laying as in repair sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Taking down ceiling fan 1200mm sweep, after disconnecting the all electrical connection carefully and dismantling of blades, opening the stator & rotor, cutting existing burnt winding and rewinding with super enamelled copper winding wire, varnishing etc including scraping the old paint ,cleaning and washing with washing powder, filling cavities with filler and painting to ceiling fan by using synthetic enamel paint in two coats by spray, replacing unserviceable parts such as capacitor, ball bearing, bush with new parts and reassembling, testing and refixing/rehanging the ceiling fan and connecting up including provision of flexible cable 23/.0076 from ceiling rose or connector to fan complete all as specified and as directed by the Engineer-in-Charge.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Swami Enterprises
M/s Vridhi Construction Co.
bhagwandasswazirchand
M/S SHASTRI BUILDERS AND ENGINEERS
M/s B.S.Jain
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .