Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹31.1 L+₹4.2 L (15.5%)Rejected-Finance | L2 | Rejected-Finance Being not L1 Bidder | |
| 3 | L3₹34.3 L+₹7.4 L (27.4%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L3 | Rejected-Finance Being not L1 Bidder | |
| 4 | L4₹34.4 L+₹7.4 L (27.6%)Rejected-Finance MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | L4 | Rejected-Finance Being not L1 Bidder | |
| 5 | L5₹36.0 L+₹9.1 L (33.7%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L5 | Rejected-Finance Being not L1 Bidder |
| Sl No | Description | Qty | Unit | MSN ENGINEERING WORKS L5 | M/S CHANDRA ENGINEERS AND CONTRACTORS L6 | SRI SAI KRISHNA ENGINEERING WORKS L1 | M/s NATIONAL ENGINEERING CONSTRUCTIONS CO L2 | MVV Prasad L3 | LAKSHMI SAI CONSTRUCTIONS L8 | NJ ENTERPRISES L7 | jyothi constructions L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for attending Emergency complaints, Checking/inspecting whole DG set of make as per OEM of any capacity with AMF Panel through Skilled manpower rectifying the fault completely complete all as specified and directed.
Note:- 1. Major spares required will be measured and paid separately under relevent items of Schedule.
2. The cost of minor spares like nuts, bolts, control cable/wire of any core any length, grease etc are deemed to be included in the unit price | 6 | Each Job | 3,800 ₹22,800 | 4,200 ₹25,200 | 3,500 ₹21,000 | 2,000 ₹12,000 Lowest | 5,000 ₹30,000 | 4,500 ₹27,000 | 34,500 ₹2,07,000 | 5,000 ₹30,000 |
| 2.00 | S & F Fuel filter with O ring for 500 KVA DG of make as per OEM set including taking down existing un-serviceable Fuel filter complete all as specified and directed. | 1 | Each | 1,200 ₹1,200 | 1,560 ₹1,560 | 1,140 ₹1,140 | 1,500 ₹1,500 | 20,000 ₹20,000 | 700 ₹700 Lowest | 1,500 ₹1,500 | 2,000 ₹2,000 |
| 3.00 | All as per Sl item No. 2.00 here in before but for 125-160 KVA DG set. | 6 | Each | 650 ₹3,900 | 640 ₹3,840 | 467 ₹2,802 | 500 ₹3,000 | 12,000 ₹72,000 | 700 ₹4,200 | 450 ₹2,700 Lowest | 450 ₹2,700 Lowest |
| 4.00 | All as per Sl item No. 2.00 here in before but for 20-100 KVA DG set | 5 | Each | 600 ₹3,000 | 550 ₹2,750 | 427 ₹2,135 | 400 ₹2,000 Lowest | 8,000 ₹40,000 | 700 ₹3,500 | 400 ₹2,000 Lowest | 450 ₹2,250 |
| 5.00 | S & F Lub oil filter for 500 KVA DG set of make as per OEM set including taking down existing un-serviceable Lub oil filter complete all as specified and directed. | 2 | Each | 1,500 ₹3,000 | 2,020 ₹4,040 | 1,476 ₹2,952 Lowest | 1,500 ₹3,000 | 10,000 ₹20,000 | 5,700 ₹11,400 | 1,800 ₹3,600 | 2,000 ₹4,000 |
| 6.00 | All as per Sl item No. 5.00 here in before but for 125-160 KVA DG set. | 4 | Each | 750 ₹3,000 | 780 ₹3,120 | 570 ₹2,280 | 600 ₹2,400 | 8,000 ₹32,000 | 3,500 ₹14,000 | 180 ₹720 Lowest | 500 ₹2,000 |
| 7.00 | All as per Sl item No. 5.00 here in before but for 20-100 KVA DG set | 5 | Each | 650 ₹3,250 | 735 ₹3,675 | 535 ₹2,675 | 600 ₹3,000 | 4,500 ₹22,500 | 2,500 ₹12,500 | 180 ₹900 Lowest | 500 ₹2,500 |
| 8.00 | S & F Air cleaner filter ( inner and outer ) for 500 KVA DG set of make as per OEM including taking down existing un-serviceable Air cleaner filter complete all as specified and directed. | 1 | Each Set | 7,800 ₹7,800 | 7,800 ₹7,800 | 6,200 ₹6,200 | 6,000 ₹6,000 | 4,000 ₹4,000 Lowest | 5,000 ₹5,000 | 5,200 ₹5,200 | 7,500 ₹7,500 |
| 9.00 | All as per Sl item No. 8.00 here in before but for 125-160 KVA DG set. | 4 | Each Set | 6,000 ₹24,000 | 6,425 ₹25,700 | 3,800 ₹15,200 | 5,000 ₹20,000 | 3,000 ₹12,000 | 3,000 ₹12,000 | 3,800 ₹15,200 | 2,000 ₹8,000 Lowest |
| 10.00 | All as per Sl item No. 8.00 here in before but for 20-100 KVA DG set | 5 | Each Set | 5,000 ₹25,000 | 5,140 ₹25,700 | 2,900 ₹14,500 | 4,000 ₹20,000 | 2,500 ₹12,500 | 2,500 ₹12,500 | 2,500 ₹12,500 | 1,500 ₹7,500 Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
5 Jun 2025, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR / MAINT OF DG SETS, CENTRAL AC PLANT, LT UG CABLES, STREET AND GARDEN LIGHTS AND OTHER MISC WORKS AT SAMUDRIKA, SATAVAHANA, VIRBAHU, CSP AND OTHER ALLIED AREAS UNDER AGE E/M NO-I OF GE (U-I) VISAKHAPATNAM
2025_MES_708211_1
8736/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Utility-I
₹96,000
Yes
12 Aug 2025
15 May 2025
7 Jun 2025
15 May 2025
5 Jun 2025
30 May 2025
Amount
M & L for attending Emergency complaints, Checking/inspecting whole DG set of make as per OEM of any capacity with AMF Panel through Skilled manpower rectifying the fault completely complete all as specified and directed. Note:- 1. Major spares required will be measured and paid separately under relevent items of Schedule. 2. The cost of minor spares like nuts, bolts, control cable/wire of any core any length, grease etc are deemed to be included in the unit price
S & F Fuel filter with O ring for 500 KVA DG of make as per OEM set including taking down existing un-serviceable Fuel filter complete all as specified and directed.
All as per Sl item No. 2.00 here in before but for 125-160 KVA DG set.
All as per Sl item No. 2.00 here in before but for 20-100 KVA DG set
S & F Lub oil filter for 500 KVA DG set of make as per OEM set including taking down existing un-serviceable Lub oil filter complete all as specified and directed.
All as per Sl item No. 5.00 here in before but for 125-160 KVA DG set.
All as per Sl item No. 5.00 here in before but for 20-100 KVA DG set
S & F Air cleaner filter ( inner and outer ) for 500 KVA DG set of make as per OEM including taking down existing un-serviceable Air cleaner filter complete all as specified and directed.
All as per Sl item No. 8.00 here in before but for 125-160 KVA DG set.
All as per Sl item No. 8.00 here in before but for 20-100 KVA DG set
S & F Bypass filter for 500 KVA DG set of make as per OEM including taking down existing un-serviceable Bupass filter complete all as specified and directed.
All as per Sl item No. 11.00 here in before but for 125-160 KVA DG set.
S & F V belt for 500 KVA DG set of make as per OEM including taking down existing un-serviceable V belt complete all as specified and directed.
All as per Sl item No. 13.00 here in before but for 125-160 KVA DG set.
All as per Sl item No. 13.00 here in before but for 20-100 KVA DG set
S & F Display control panel (LED Board) for 20 to 500 KVA DG set of make as per OEM including taking down existing un-serviceable Display control panel complete all as specified and directed.
S & F Fuel actuator with O Ring for 20 to 500 KVA DG set of make as per OEM including taking down existing un-serviceable Fuel actuator complete all as specified and directed.
S & F Key switch for 20 to 500 KVA DG set of make as per OEM including taking down existing un-serviceable Key switch complete all as specified and directed.
S & F Coolant temperature sensor (coolent control safety) for 25 to 500 KVA DG set of make as per OEM including taking down existing un-serviceable Coolant temperature sensor complete all as specified and directed.
S & F AMF controller assy for auto / manual operation for 25 to 500 KVA DG set of make as per OEM including taking down existing un-serviceable AMF controller assy complete all as specified and directed.
S & F Control assy main generator panel any type for 25 to 500 KVA DG set of make as per OEM including taking down existing un-serviceable Control assy main generator panel complete all as specified and directed.
S & F Lube oil pressure sensor adaptor (oil control safety ) 25 to 500 KVA DG set of make as per OEM including taking down existing un-serviceable Lube oil pressure sensor adaptor complete all as specified and directed.
S & F Stop solenoid switch 12 Volts of make as per OEM including taking down existing un-serviceable Stop solenoid switch complete all as specified and directed.
S & F Stop solenoid switch 24 Volts of make as per OEM including taking down existing un-serviceable Stop solenoid switch complete all as specified and directed.
Supply & Fill Coolant for radiators of make as per OEM complete all as specified and directed.
S & F Turbo charger for any capacity DG set of make as per OEM including taking down existing un-serviceable Turbo charger complete all as specified and directed.
Supply & Fill Engine oil multi grade 15W40 including taking down un-serviceable Engine Oil complete all as specified and directed.
S & F Automatic Voltage Regulator fit for DG set of make as per OEM including taking down existing un-serviceable Automatic Voltage Regulator complete all as specified and directed.
Calibration of FIP and fuel injector from the authorised dealer including petty replacements to make the FIP and injectors functional for the following capacities of DG 20-500 KVA all as specified and directed.
Disconnecting the electric connection of Alternator of capacity 20- 500 KVA DG set, taking the accumalator and cleaning the core assembly through air blower, heat varnishing with insulating material complete all as directed.
S & F Lub Oil cooler plate of make as per OEM including taking down existing un-serviceable Lub Oil cooler plate complete all as specified and directed.
S & F Lub Oil pressure gauge pipe of required standard size of make as per OEM including taking down existing un-serviceable Lub Oil pressure gauge pipe complete all as specified and directed.
S & F Oil spray nozzle assembly of make as per OEM including taking down existing un-serviceable Oil spray nozzle assembly complete all as specified and directed.
S & F Main Bearing of various sizes for DG set of any capacity of make as per OEM including taking down existing un-serviceable Main Bearing complete all as specified and directed.
S & F Water temp switch of make as per OEM including taking down existing un-serviceable Water temp switch complete all as specified and directed.
S & F Magnetic Pick Up Unit ( MPU) of make as per OEM including taking down existing un-serviceable MPU complete all as specified and directed.
S & F Water Pump of make as per OEM including taking down existing un-serviceable water pump complete all as specified and directed.
S & F Lub Oil pump high discharge of required standard size of make as per OEM including taking down existing un-serviceable Lub Oil pump high discharge complete all as specified and directed.
S & F Eye bolt for 20-500 KVA DG set of make as per OEM including taking down existing un-serviceable Eye bolt complete all as specified and directed.
S & F Fan key for 20-500 KVA DG set of make as per OEM including taking down existing un-serviceable Fan key complete all as specified and directed.
S & F Battery terminal made with brass for 12 volt battery including taking down existing un-serviceable Battery terminal complete all as specified and directed.
S & F 12 volt, 180 AH battery including taking down existing un - serviceable battery and complete all as specified and directed.
M & L for cleaning external surface with cleaning agent including cleaning / descaling of radiators coil with with mild acid (or caustic soda) and cleaning of fuel tank etc of the any capacity any make complete all as specified and directed.
S & F Self starter 24 volt DCof make as per OEM including taking down existing un-serviceable Self starter complete all as specified and directed.
S & F Self starter 12 volt DCof make as per OEM including taking down existing un-serviceable Self starter complete all as specified and directed.
Maintanence and servicing the AMF panel and replace the unserviceable items and testing and replace unserviceable wiring connection in panel for automatic operation through relay, contactor, timer, sensor etc all as directed
S & F Digital multi function meter ( V, A, PF) , class 0.5 , suitable for AMF panel including taking down existing un-serviceable Digital multi function meter complete all as specified and directed.
S & F of Indicator lamp (R,Y & B) suitable for AMF panel including taking down existing un-serviceable Indicator lamp complete all as specified and directed.
S & F 3 pole power contractor type AC3 not less than 130 A with Aux contacts 2 Nos 2 NC , suitable for AMF panel including taking down existing un-serviceable power contractor complete all as specified and directed.
S & F 3 pole power contractor type AC3 not less than 225 A with Aux contacts 2 Nos 2 NC , suitable for AMF panel including taking down existing un-serviceable power contractor complete all as specified and directed.
S & F 3 pole power contractor type AC3 not less than 500 A with Aux contacts 2 Nos 2 NC , suitable for AMF panel including taking down existing un-serviceable power contractor complete all as specified and directed.
S&F LED street light fitting of capacity 60 watt, at a height 7.5m to 11m, 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant, toughened glass cover including thermal management in multiple optics complete, high efficiency electronic driver, IP-65 (minimum) protection, integrated type, SPD of capaciity 10 KV, internally prewired and including electrically connecting & taking down old unserviceable street light fittings complete all as specified and as directed. Note:- Supply of new GI Pipe bracket if required shall be measured and paid seperately under relevant item.
All as per serial Item No. 52.00 above but LED street light fitting of capacity 90 W
S&F LED flood light fitting of capacity 120 watt,at a height 7.5m to 11m, 230 V AC outdoor type, IP-65 (minimum), SPD of capaciity 10 KV, pressure die cast aluminium housing, toughened glass cover with thermal management in multiple optics, with impact and corrosion resistant complete with driver and lamp, internally prewired and including electrically connecting & taking down old unserviceable flood light fittings from any position at a height exceeding 7.5 m complete all as specified and directed.
All as per serial Item No. 54.00 above but LED flood light fitting of capacity 200 W, at a height 7.5 m to 20 m.
M&L for bracket suitable for street light made out of GI pipe medium grade of 40 mm bore & 1.20 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer including taking down existing un-serviceable bracket complete all as specified and directed.
M&L cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections and including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including preparation of surfaces and applying two coats of aluminium paint over a coat of primer and dismantling complete all as specified and directed.
S&F PVC insulated 3 core multistranded sheathed cable with 1.5 Sqmm copper conductor for connection of street / security light etc. including taking down existing un-serviceable cable complete all as specified and directed.
S & F 1 x 8 watt LED bollard light fitting, inverted pyramid tripod type shape, IP-65, including hot dip galvanized pole, driver, all fixing arrangement etc. including electrically connecting & taking down complete all as specified and directed.
S&F post top lantern LED type 35 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light, with impact and corrosion resistant complete & high efficient constant current electronic driver and lamp, polycarbonate opal diffuser, pressure die cast aluminium housing, IP-65 (minimum) including electrically connecting and taking down old unserviceable post top lantern complete all as specified and directed.
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 25 Sqmm x 4 Core, laid in trenches / duct / on pole including taking down existing unserviceable cable complete all as specified and directed.
All as per Sl item No. 61.00 here in before but cross sectional area 50 Sqmm x 3.5 Core
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with clean and dry crushed stone dust in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness of crushed stone dust coushioning shall only measured and paid.
Supply & laying sub class 'B', class designation 75 bricks of old size, laid over sand cushioning along alignment of cable as protection to cable in trenches including taking out old bricks complete all as specified and directed. Note : Sand cushioning will measured and paid separately.
S&F steel tubular swaged poles conforming to IS-2713, complete with cast iron base plate, finial taper plug, bolts, nuts & screws, type 410 SP-31 (9 m long) and including painting with two coat of aluminium paint over a coat of primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and 03 Nos band / strips with white synthetic enamel paint, 30 cm wide each at a distance of 30 cm from top of plinth block and numbering of poles including taking down existing un-serviceable pole complete all as specified and directed. Note:- Excavation, earth work and PCC work will be measured and paid for separately under respective items.
M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete including demolition of existing concrete complete all as specified and directed.
M&L plain cement concrete (1:2:4) type B1, (using 20 mm graded crushed stone aggregate) as in copings, benching and the like etc. including necessary formwork & demolition of old concrete complete all as specified and directed.
M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable / cable protection pipe including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) / bituminous mix as per existing & matching with the surroundings including removal of rabbish off to distance not exceeding 100 m complete all as specified and directed. Note:- Unit rate quoted against this item shall deemed to include cost for necessary cement concrete work required for making good top surface.
S&F 50 mm bore dia galvanised steel tubing, light grade, laid under road crossing, for cable protection or fixed to poles, walls or laid under floors including taking down existing un-serviceable pipe of any description. complete all as specified and directed.
Taking down existing loop in loop out junction box, disconnecting the cable connections and refixing the same loop in loop out junction box with new cable connections including providing new set of aluminium lugs / thimbles of size 10 to 35 sqmm (as reqd) for 3.5/4 core existing LT cable of any type, necessary insulation with tape, clamps for fixing of cables, fittings and fixtures, nut bolts etc complete all as specified and directed.
Taking down defective street light fitting of any make / type / capacity from top of pole / walls / high mast at a height exceeding 7.0 m but not exc 9.0 m, at any location, for repair work, checking the fault in the street lights including Junction Box or connecting cable, re-fixing the same after repair work including testing and commissioning complete all as specified and directed. Note:- (i) M&L for Items like ballast, lamp, ignitor, capacitors, electronic drivers, surge protection devices etc shall be measured and paid separately under respective item of this schedule/BOQ. However rate quoted shall deemed to include S&F of minor spares like lugs, nuts, bolts, circle clips, clamps etc (ii) Necessary T&P like ladders etc required to take the fitting down shall be arranged by the contractor. (iii) M&L for repairs to LED Panel will be measured and paid separately.
S&F weather proof cable junction box of size not less than 210 mm x 310 mm x 116 mm with terminals, IP 66 (minimum), suitable for outdoor installation including 01 No MCB 5/6 Amp, 100 Amp rated single pole connector, fixing arrangement with MS flat of size 25 x 3 mm with necessary nuts, bolt and washers including taking down existing un-serviceable junction box complete all as specified and directed.
M&L preparation of old painted surface of existing 9 m long steel poles with connected cross arms, cable protection pipes, clamps, street light brackets etc, and including applying one coat of aluminium paint on complete height of the pole and applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with multi colour strips as per the colour code, writing pole details & applying one coat of white wash on pole coping complete all as specified and directed.
S&F in repair electronic driver of make as per existing, suitable for 120 to 200 W street light / flood light / post top lantern complete all as specified and directed.
All as per serial Item No. 77.00 here in before but suitable for 45 to 100 W
S&F in repairs surge protection device of capacity 10 KV & make as per existing, suitable for street light / flood light / post top lantern complete all as specified and directed.
M&L for wiring from LED panel to driver for capacity 120-200 W LED fittings including taking down existing un-serviceable wiring complete all as specified and directed.
All as in Item No 80 here in before but for 45-100 W LED fittings
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point including dismantling un-serviceable earthing complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
S& F 4 pole connector 440V AC including taking down existing connector complete all as specified and directed.
S&F MCCB 4 pole 40 to 63 Amp, breaking capacity 16 kA, Ics = 100% Icu, thermal magnetic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 ln) including necessary modification in the panel including taking down existing Un-serviceable MCCB complete all as specified and as directed.
M&L for complete leak testing of all connected units of central AC plant of capacity 48 TR, complete refrigerant pipe with Nitrogen gas, locating the leaks if found, opening condenser/compressor/chiller if required to find out leakage, rectify the leak by brazing / welding and pressure testing the complete system all as specified and as directed by Engineer-in-Charge. Note:- The refilling of R407 gas will be measured and paid separately
M&L for attending Emergency breakdown of central AC plant units at samudrika on call basis identifying and resolving issues complete all as specified and directed. The cost of minor spare parts such as Nuts, bolts, control wire, pump gasket, weldings if required etc. are deemed to be included in the unit price. The cost of major spare parts will be measured and paid separately under relevant items.
Supply and charge refrigerant gas R 407 C incuding leak testing the system, arresting the leaks with necessary materials like gasket/ 'o' rings/ washers all as directed by Engineer-in-charge.
S&F 3 pole contactor of capacity 40 Amp capacity suitable for central AC plant of capacity 48 TR including taking down existing contactor complete all as specified and directed.
S&F EWT / LWT sensor suitable for central AC plant of capacity 48 TR including taking down existing contactor complete all as specified and directed.
M&L for dismantling defective induction motor of 7.5 HP capacity & any make, 415 V, of any duty or any class of insulation from the bed duly coupled with pump, transporting to work shop, removing burnt out winding from stator, rotor and re-winding the same with existing gauge super enameled copper wire of approved make and supply & replacing driven end and non driven end bearings, insulation materials, varnishing, heating, reassembling, testing and commissioning complete all as specified and directed. Notes :- Motor removed for rewinding shall be overhauled completely and quoted rate shall be deemed to be inclusive for the same.
Dismantling pump/motor set 7.5 HP and disconnecting water and electric connection removing shaft from impeller and dismantling, grinding, polishing to shaft & suction cover and replacing , Gun metal bushes for shaft , Key for shaft , Graphite packing , water slinger , Gland bush, coupler etc fixing gland rope, greasing and fixing same shaft and impeller and reassembling properly testing all as specified and directed.
Dismantling pump/motor set of capacity 8000 CFM and disconnecting water and electric connection removing shaft from impeller and remantling, grinding, polishing to shaft & suction cover and replacing , Gun metal bushes for shaft , Key for shaft , Graphite packing , water slinger , Gland bush, coupler etc fixing gland rope, greasing and fixing same shaft and impeller and reassembling properly testing all as specified and directed.
All as per Item Sl No. 93.00 here in before but for capacity 37500 CFM
M&L for removing the wornout duct insulation carefully, cleaning / preparation of duct surface by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, providing new duct insulation, not less than 13mm thick with nitrile rubber insulation with aluminium film reflective surface including taking special care to ensure duct joints sealed against any leakage complete all as specified and directed.
M&L for taking down 48 TR Chiller package unit direct expansion type outdoor including dismantling the units carefully, chemical cleaning of chiller, condenser tube and control piping, with appropriate cleaning agents, flushing through proper air flow across the coils to improve the cooling efficiency, reassembling & re-installing the units in their original position testing & commissioning complete all as directed by Engr-in-Charge.
S & F Scroll compressor suitable for AC plant of capacity 48 TR (Bluestar, Model - XAC2YS-048AR2) of make as per OEM including taking down existing compressor complete all as specified and directed.
S & F Expansion Valve suitable for AC plant of capacity 48 TR (Bluestar, Model - XAC2YS-048AR2) of make as per OEM including taking down existing Expansion Valve complete all as specified and directed.
S & F Pressure Controller suitable for AC plant of capacity 48 TR (Bluestar, Model - XAC2YS-048AR2) of make as per OEM including taking down existing Pressure Controller complete all as specified and directed.
S & F ODU Fan Motor-2 HP suitable for AC plant of capacity 48 TR (Bluestar, Model - XAC2YS-048AR2) of make as per OEM including taking down existing ODU Fan Motor complete all as specified and directed.
S&F MCCB 3 pole 63 to 100 Amp, breaking capacity 36 kA, Ics = 100% Icu, thermal magnetic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 ln) including necessary modification in the panel & taking down existing un-serviceable MCCB complete all as specified and as directed.
S&F MCCB 4 pole 160 Amp, breaking capacity 36 kA, Ics = 100% Icu, thermal magnetic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 ln) including necessary modification in the panel & taking down existing un-serviceable MCCB complete all as specified and as directed.
S&F Pressure gauge with syphon & valve including taking down existing un-serviceable pressure guage complete all as specified and directed.
S&F Thermometer with valve including taking down existing un-serviceable Thermometer complete all as specified and directed.
M&L for opening the outer sheets of Air Handling Unit (AHU) to access cooling coil, washing / cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning / washing of air filter and re-fixing, complete all as specified and directed by GE.
S & F Microprocessor controller cord module for chilled water system suitable for 48 TR capacity of Make Bluestar, Model - XAC2YS-048AR2 chiller unit including taking down existing un-serviceable Microprocessor controller cord module complete all as specified and directed.
S & F Microcomputer display board suitable for 48 TR chiller unitof Make : Bluestar, Model - XAC2YS-048AR2 including taking down existing un-serviceable Micocomputer display board complete all as specified and directed.
S & F AC/DC converter suitable for 48 TR chiller unitof Make : Bluestar, Model - XAC2YS-048AR2 including taking down existing un-serviceable AC/DC converter complete all as specified and directed.
S & F Condenser water temperature sensor for 48 TR chiller unit of Make Bluestar, Model - XAC2YS-048AR2 including taking down existing un-serviceable Condenser water temperature sensor complete all as specified and directed.
S & F discharge pressure sensor for 48 TR chiller unit of Make : Bluestar, Model - XAC2YS-048AR2 including taking down existing un-serviceable discharge pressure sensor complete all as specified and directed.
S & F single phase preventor 40 VAC asymmetry including connecting accessories including taking down existing un-serviceable single phase preventor complete all as specified and directed.
S & F Intermediate relay 220 V AC for 48 TR chiller unit of Make : Bluestar, Model - XAC2YS-048AR2 including taking down existing un-serviceable Intermediate relay complete all as specified and directed.
S & F liquid level sensor suitable for 48 TR unit of Make : Bluestar, Model - XAC2YS-048AR2 including taking down existing un-serviceable liquid level sensor complete all as specified and directed.
S & F Solenoid Coil suitable for 48 TR of Make : Bluestar, Model - XAC2YS-048AR2 including taking down existing un-serviceable Solenoid Coil complete all as specified and directed.
S & F Oil Filter suitable for 48 TR unit of Make : Bluestar, Model - XAC2YS-048AR2 including taking down existing un-serviceable Oil Filter complete all as specified and directed.
S&F Pre filter 10 micron, a layer of non woven media stitched along with layer of GI wire mesh on the downstream side to obtain required filtration and efficiency, pleats separated by spacers for maximum air flow of size 610x610x50mm including taking down existing filters complete all as specified and directed.
S & F Suction pressure sensor for chiller unit 48TR of Make : Bluestar, Model - XAC2YS-048AR2 including taking down existing Suction pressure sensor complete all as specified and directed.
S & F V belt A/B Series as per site requirement including taking down existing V belt complete all as specified and directed.
S & F Overload relay type range 30-40 A as per site requirement including taking down existing Overload relay complete all as specified and directed.
S&F on-load change over switch 400 Amp capacity, 3 phase, 415 volts With sheet steel encloser including taking down existing switch complete all as specified and directed.
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO (BID ID -3314345)
MVV Prasad (BID ID -3314473)
jyothi constructions (BID ID -3314003)
MSN ENGINEERING WORKS (BID ID -3311230)
M/S CHANDRA ENGINEERS AND CONTRACTORS (BID ID -3313128)
NJ ENTERPRISES (BID ID -3314224)
LAKSHMI SAI CONSTRUCTIONS (BID ID -3314476)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .