Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | ₹12.9 L Quoted ₹13.1 L | L1 | Accepted-AOC Competitive |
| 2 | L2₹17.4 LRejected-Finance | ₹17.4 L | L2 | Rejected-Finance Not a competitive |
| 3 | L3₹20.6 LRejected-Finance | ₹20.6 L | L3 | Rejected-Finance Not a competitive |
| 4 | Rejected-Technical 3 PL SATHIYAMOORTHY STREET DR RADHAKRISHNAN NAGAR MEENACHIPET PUDUCHERRY 605009 | PONDICHERRY | PUDUCHERRY | 605009 | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | M/S HELIO ENGINEERING PRIVATE LIMITED,CHENNAI. L2 | HYDROTEC ENGINEERS INDIA PRIVATE LIMITED L3 | FIREPROPLUS L1 |
|---|---|---|---|---|---|---|
| 1.00SUPPLY OF FIRE ALARM SYSTEM | ||||||
| 1.01 | Addressable fire alarm panel with 2 loop cards suitable to accommodate 250 nos of devices per loop with networking card | 1 | Nos. | 2,15,000 ₹2.1 L | 1,59,650 ₹1.6 L | 1,25,000 ₹1.3 L |
| 1.02 | Addressable multi sensor Smoke Detector with base | 40 | Nos. | 3,300 ₹1.3 L | 3,605 ₹1.4 L | 2,500 ₹1 L |
| 1.03 | Addressable optical Smoke Detector with base | 30 | Nos. | 3,300 ₹99,000 | 3,348 ₹1.0 L | 2,450 ₹73,500 |
| 1.04 | Addressable heat Detector with base | 3 | Nos. | 3,300 ₹9,900 | 3,348 ₹10,044 | 3,450 ₹10,350 |
| 1.05 | Addressable Manual pull station / break galss unit of aluminium Die-cast materials enclosure | 20 | Nos. | 4,900 ₹98,000 | 4,635 ₹92,700 | 2,987 ₹59,740 |
| 1.06 | Addressable control module with back box and cover including junciton box as required for AHU tripping | 3 | Nos. | 4,300 ₹12,900 | 4,635 ₹13,905 | 2,544 ₹7,632 |
| 1.07 | Sounder cum strobe -inlcuding junction box as required | 20 | Nos. | 6,750 ₹1.4 L | 3,220 ₹64,400 | 4,300 ₹86,000 |
| 1.08 | Addressable sounder control module with back box and cover | 10 | Nos. | 4,300 ₹43,000 | 4,635 ₹46,350 | 3,750 ₹37,500 |
| 1.09 | Short circuit Isolator modules | 5 | Nos. | 4,200 ₹21,000 | 3,478 ₹17,390 | 2,900 ₹14,500 |
Tender Value
Refer Docs
Closing Date
29 Apr 2026, 3:00 pmClosed
CGM (PROJECTS and ENERGY)
TNPL UNIT-I, KAGITHAPURAM, KARUR DISTRICT
Supply and Installation of Fire Alarm System for TM5 at TNPL Unit II
2026_TNPL_675956_1
TNPL/UNIT-II/TM#5/262723000244
Open Tender
Electrical Goods/Equipments
28 days
TNPL Unit II, Trichy
As per Part 1 of Bid Document
7 documents required · 7 mandatory
₹0
Exempted
6 Jun 2026
22 Apr 2026
30 Apr 2026
22 Apr 2026
29 Apr 2026
24 Apr 2026
22 Apr 2026 - 28 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1SUPPLY OF FIRE ALARM SYSTEM | ||||||
| 1.01 | Addressable fire alarm panel with 2 loop cards suitable to accommodate 250 nos of devices per loop with networking card | 1 | Nos. | - | - | itemH1Code1 |
| 1.02 | Addressable multi sensor Smoke Detector with base | 40 | Nos. | - | - | itemH1Code2 |
| 1.03 | Addressable optical Smoke Detector with base | 30 | Nos. | - | - | itemH1Code3 |
| 1.04 | Addressable heat Detector with base | 3 | Nos. | - | - | itemH1Code4 |
| 1.05 | Addressable Manual pull station / break galss unit of aluminium Die-cast materials enclosure | 20 | Nos. | - | - | itemH1Code5 |
| 1.06 | Addressable control module with back box and cover including junciton box as required for AHU tripping | 3 | Nos. | - | - | itemH1Code6 |
| 1.07 | Sounder cum strobe -inlcuding junction box as required | 20 | Nos. | - | - | itemH1Code7 |
| 1.08 | Addressable sounder control module with back box and cover | 10 | Nos. | - | - | itemH1Code8 |
| 1.09 | Short circuit Isolator modules | 5 | Nos. | - | - | itemH1Code9 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BidDocument_FireAlarmSigned.pdf
Tender Documents • 6.51 MB
BOQ_812352.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid