Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹59,551Accepted-Finance | ₹59,551 | 1 | Accepted-Finance lowest |
| 2 | 2₹61,259+₹1,708 (2.87%)Accepted-Finance | ₹61,259+₹1,708 (2.87%) | 2 | Accepted-Finance 2nd lowest |
| 3 | 3₹62,060+₹2,509 (4.21%)Accepted-Finance | ₹62,060+₹2,509 (4.21%) | 3 | Accepted-Finance 3rd lowest |
Tender Value
₹59,952
EMD Value
₹1,199
Closing Date
28 Jan 2022, 11:00 amClosed
AC(ELECT)FTR HQ BSF GUJ
FTR HQ BSF GUJ
Construction of store room and providing and fixing chain link fencing for 11 KV HT Line substation at FTR HQ BSF campus Gandhinagar Gujarat SH Electrification of building EI and Fans
2022_BSF_669701_1
13/FTR-GUJ(Elect)/e-nit/21-22
Open Tender
Electrical Works
Works
150 days
BSF Campus Gandhinagar
as per tender enquiry
6 documents required · 6 mandatory
₹0
₹1,199
14 Feb 2022
21 Jan 2022
31 Jan 2022
21 Jan 2022
28 Jan 2022
22 Jan 2022
22 Jan 2022 - 28 Jan 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required
3 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
Telephone socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1 Pair
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required.
Single pole
Single pole and neutral
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supply and fixing of surface mounted 1200 mm long universal batten suitable for LED tube lights and along with 20 watt LED tubelight complete with all acessories directly on celling/wall with connection and earthing etc as req. including dismentalling the exsisting fittings (C&S/Philips /Wipro /Crompton/Havells) or compatible make.
Providing and fixing of 30 watt LED flood light fitting of outdoor type with classification of IP 65, Class-I, body made out of pressure diecast aluminium, high efficiency with metallic finish paint, poly carbonate designed reflector for light distribution, toughened glass sealed with silicon gaskets and integral driver unit, suitable for operation on 240 Volts, directly on ceilling / wall including connection with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, earthing etc. as required. (Polycab/C&S/HPL/Philips/Wipro/Havells/Crompton)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying, installation, testing and commissioning of ISI marked A.C. ceiling fan having double ball bearing along with 3 nos aluminium alloy blades, Canopy and 300 mm down rods etc as required but without fan regulator. including wiring the down rod of standrad length (up to 30 cm) with 1.5 sqmm, FRLS PVC insulated, copper conductor, single core cable, etc. as required. (Make : Havells Velocity ES-50 ISI Mark or Equivalent Make of Bajaj,CG,Orient 1400 mm Sweep,White Colour)
Supplying & fixing of wall bracket light fitting directly on wall i/c providing and fixing of LED of 9/10 watt as required LED of make Havells City 3 or equivalent make of Philips / Crompton or compatible make.
Supplying and Laying of one following size PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Aluminum armoured cable direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Havells/Polycab/RR Kabel/Finolex
2 x 25 Sq mm power cable aluminium conductor armoured cable
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Havells/Polycab/RR Kabel/Finolex
2 x 25 Sq mm power cable aluminium conductor armoured cable
TUSHAR ELECTRICALS
Rhythm Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .