Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | ₹13.8 L Quoted ₹14.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹15.0 LRejected-Finance BIAMATHANG BAROO KARGIL J K | KARGIL | KARGIL | J K | ₹15.0 L | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Due to not enlisted in requiste category, not having min experience as per NIT, EMD not submitted, DD Not submitted and Documents as per NIT are not found attached |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to not enlisted in requiste category, not having min experience as per NIT, EMD not submitted, DD Not submitted and Documents as per NIT are not found attached |
| Sl No | Description | Qty | Unit | M/S MOHD KHAN L2 | M/s Raj Construction L1 |
|---|---|---|---|---|---|
| 1.00 | Disconnecting the existing refrigerators/Deep freezer of any capacity and transporting the same from site/AEG B/R-II yard to authorised service centre /workshop for repair of body ,replacing outer damaged body parts, welding door hinges and back after necessary repair/ repair of old unserviceable or wornout accessories/ parts in the workshop and re-fixing/ re-connecting the same in existing position and testing on completion for efficient cooling complete all as specified and directed for the following capacities:-
Note:- Gas charging and repair of spare parts of refrigerators shall be measured and paid separately under respective items mentioned in schedule complete. | 10 | EACH | 4,000 ₹40,000 | 2,600 ₹26,000 |
| 2.00Supply and fixed in repair, compressors of refrigerators/Deep freezer of following models including cutting the suction and discharge line for removing of un-serviceable compressors and fixing of new compressors by jointing suction & discharge line, welding, brazing/ soldering, vaccumising and charging of gas with required quantity of R-134(a) gas to achieve the efficient cooling & smooth functioning and testing on completion complete all as specified and directed:- Note:- Gas charging of refrigerators shall be measured and paid separately under respective items of Sch'A' as "material and labour" complete. | |||||
| 3.00 | Compressor of make Kirloskar/Tecumseh/LG for refrigerator refrigerators/Deep freezer of 120 to 230 Ltrs capacity omplete all as specified and directed. | 4 | EACH | 9,700 ₹38,800 | 9,200 ₹36,800 |
| 4.00 | Compressor of make Kirloskar/Tecumseh/LG for refrigerator refrigerators/Deep freezer of 240 to 500 Ltrs capacity omplete all as specified and directed. | 5 | EACH | 12,300 ₹61,500 | 11,000 ₹55,000 |
| 5.00 | Supply and fixed in repair, PVC stand of refrigerators 100 ltr to 420 ltr of best quality suitable for refrigerators of OFF sizes complete all as specified and directed. | 5 | EACH | 1,000 ₹5,000 | 1,100 ₹5,500 |
| 6.00 | Disconnecting of the unserviceable voltage stabilizers capacity upto 5 KVA from the site and removing to workshop for repair and re-fixing/testing/commissioning at the original position after rewinding / replacement of parts/spares to the extent required /reassembling complete all as specified and directed.
Note :- Spares/parts shall be measured and paid seperately under respective items of Sch A as " Supply only". | 15 | Each Job | 140 ₹2,100 | 90 ₹1,350 |
| 7.00 | Supply only main transformer with super enameled copper wire proper insulated upto 5 KVA capacity for volatage stabilizer complete as specified and directed. | 8 | EACH | 1,400 ₹11,200 | 1,100 ₹8,800 |
| 8.00 | Supply only volt meter 0 to 300 volts complete all as specified and directed | 4 | EACH | 600 ₹2,400 | 450 ₹1,800 |
| 9.00 | S&F in replacement of main PCB for voltage stabilizer 0.5 KVA to 5.0 KVA of approved make complete all as specified and directed. | 10 | EACH | 900 ₹9,000 | 800 ₹8,000 |
| 10.00 | S&F in replacement of auxiliary transformer for the 0.5 KVA to 5 KVA capacity stablizer of approved make complete all as specified and directed. | 6 | EACH | 500 ₹3,000 | 400 ₹2,400 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
15 Nov 2025, 9:00 amClosed
GE Khumbathang
Khumbathang
GE/KHU-71/2025-26 COMPREHENSIVE MAINT OF DEEP FREEZER REFRIGERATOR HAMMAN HEATING APPLIANCES AND CONNECTED WKS AT LAMAYURU KHALTSI HANUTHANG ACHINATHANG BATALIK AND BIAMAH AND COMPREHENSIVE MAINT OF RO PLANT AT BIAMAH IN THE AOR OF AGE BR II KHALTSI
2025_MES_735163_1
GE/KHU-71/2025-26
Open Tender
Support/Maintenance Service
180 days
GE Khumbathang
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE khumbathang
₹28,000
22 Dec 2025
14 Oct 2025
16 Nov 2025
14 Oct 2025
15 Nov 2025
27 Oct 2025
15 Oct 2025 - 25 Oct 2025
Amount
Disconnecting the existing refrigerators/Deep freezer of any capacity and transporting the same from site/AEG B/R-II yard to authorised service centre /workshop for repair of body ,replacing outer damaged body parts, welding door hinges and back after necessary repair/ repair of old unserviceable or wornout accessories/ parts in the workshop and re-fixing/ re-connecting the same in existing position and testing on completion for efficient cooling complete all as specified and directed for the following capacities:- Note:- Gas charging and repair of spare parts of refrigerators shall be measured and paid separately under respective items mentioned in schedule complete.
Supply and fixed in repair, compressors of refrigerators/Deep freezer of following models including cutting the suction and discharge line for removing of un-serviceable compressors and fixing of new compressors by jointing suction & discharge line, welding, brazing/ soldering, vaccumising and charging of gas with required quantity of R-134(a) gas to achieve the efficient cooling & smooth functioning and testing on completion complete all as specified and directed:- Note:- Gas charging of refrigerators shall be measured and paid separately under respective items of Sch'A' as "material and labour" complete.
Compressor of make Kirloskar/Tecumseh/LG for refrigerator refrigerators/Deep freezer of 120 to 230 Ltrs capacity omplete all as specified and directed.
Compressor of make Kirloskar/Tecumseh/LG for refrigerator refrigerators/Deep freezer of 240 to 500 Ltrs capacity omplete all as specified and directed.
Supply and fixed in repair, PVC stand of refrigerators 100 ltr to 420 ltr of best quality suitable for refrigerators of OFF sizes complete all as specified and directed.
Disconnecting of the unserviceable voltage stabilizers capacity upto 5 KVA from the site and removing to workshop for repair and re-fixing/testing/commissioning at the original position after rewinding / replacement of parts/spares to the extent required /reassembling complete all as specified and directed. Note :- Spares/parts shall be measured and paid seperately under respective items of Sch A as " Supply only".
Supply only main transformer with super enameled copper wire proper insulated upto 5 KVA capacity for volatage stabilizer complete as specified and directed.
Supply only volt meter 0 to 300 volts complete all as specified and directed
S&F in replacement of main PCB for voltage stabilizer 0.5 KVA to 5.0 KVA of approved make complete all as specified and directed.
S&F in replacement of auxiliary transformer for the 0.5 KVA to 5 KVA capacity stablizer of approved make complete all as specified and directed.
Supply and fixing of voltage stablizers of 5 KVA capacity including its installation and connecting with the existing machinery.
M&L for rewiring (wiring kit) of deep freezeer,refrigerator with using best quality PVC insulated copper conductor cable including thimbles sleaves of suitable size & shape complete all as specified and directed.
Supply and fixed in replacement, fins and tube type air cooled copper condensers of following capacity of any make complete all as specified and directed including taking down the old U/S fins:-
Refrigerator of capacity 120-200 ltrs.
Deep freezers of capacity 200 to 500 ltrs.
Supply and fixing of Running/Starting capacitors of the following capacities for Refrigerators/ Deepfreezers etc.all as specified and as directed by Engr-in-Charge
Upto05-30 mfd
Supply and fixing of starting relay of approved make including dismantling old one suitable for the following
Refrigerator of 120 to 320 liters capacity.
Deep freezers of 200 to 500 ltrs capacity.
Supply and replace thermostats of approved make including dismantling old one of the following:-
Refrigerator of 120 to 320 liters capacity.
Deep freezers of 200 to 500 ltrs capacity.
Supply and replace overload protector relay of approved make including dismantling old one of the following:-
Refrigerator of 120 to 320 liters capacity.
Deep freezers of 200 to 500 ltrs capacity.
Supply and replace blower motor of approved make including dismantling old one of the following:-
Motor for double door refrigerator 280 to 320 ltr/hr.
Motor for deep freezer 200 to 500 ltr.
Supply and replace cooling coil complete made out of copper tube of approved make complete all as specified and as directed by Engineer-in-Charge of :-
Refrigerator of upto 320 ltrs capacity.
Deep freezers of 200 to 500 ltrs capacity.
Supply and filling /top up compressor oil incl necessary bracing work for deep freezer/refrigerator of any capacity complete all as specified and directed.
M&L for replacing refrigerent gas R-134 a complete all as specified and directed
M&L for servicing of electric Hamam of capacity 25/45/50 Ltr by cleaning the inner steel body , repair of heating element , connecting terminals complete all as specified and directed.Note: Spares will be measured and paid seperately as per relevent item in schedule .
Heating element for Elelctric hamam 2 KW , 230V, 50 Hz complete all as specified and directed.
Thermostat for Elelctric hamam 2 KW , 230V, 50 Hz complete all as specified and directed.
S&F in Replacement of glass wool of Electric hamam by dismantling the outer body, replacing old damaged glass wool with new refixing innner and outer body complete all as specified and directed.
S&F in replace bib tap ( brass body) of Electric hamam 15 mm size complete all as specified and directed.
S&F in erplace electric control board of Hamam 25/35/50 ltr capacity complete wih outer body all as specified and diredted.
Dismantling of complete exhaust fan 300 mm sweep unscrewing the body parts of the exhaust fan taking out starter , rotor winding, ball bearing gun metal bush etc. Incl removing the fan from its original position ,removing of burnt out fan winding and rewinding of starter with suitable size of Copper enamelled wire, (weight of copper coil shall be same as per dismantled exhaust fan) varnishing heating as per manufactures design and directed. Re-assembling complete exhaust fan by fixing only serviceable of old/new spare parts (i.e.) condenser, gun metal bushes, ball bearing, twin twisted copper cable, incl refixing the same in its original position complete all as specified and design to give designed air delivery including greasing, oiling etc complete all as specified and directed.
All as per Sl. item no.43 above but exhaust fan of size 450 mm sweep.
All as per Sl. item no. 43 & 44 above but only overhauling of exhaust fan 450 mm / 300 mm sweep in situ by greasing and oiling except rewinding of starter winding complete all as directed.
Dismantling of complete pedestrial fan / cabin fan 400 mm sweep unscrewing the body parts of the fan taking out starter, rotor winding, ball bearing gun metal bush etc. Removing of burnt out fan winding and rewinding of starter with suitable size of copper enamelled wire, (weight of copper coil shall be same as per dismantled exhaust fan) varnishing heating as per manufactures design and directed. Re-assembling complete fan by fixing only serviceable of old/new spare parts (i.e.) condenser, gun metal bushes, ball bearing, twin twisted copper cable, complete all as specified and design to give designed air delivery including greasing, oiling etc all as directed.
Dismantling of complete PVC exhaust fan 200/250/300 mm sweep by unscrewing the body parts of the fan taking out starter, rotor winding, ball bearing gun metal bush etc. Removing of burnt out fan winding and rewinding of starter with suitable size of copper enamelled wire, (weight of copper coil shall be same as per dismantled PVC exhaust fan) varnishing heating as per manufactures design and directed. Re-assembling complete fan by fixing only serviceable of old/new spare parts (i.e.) condenser, gun metal bushes, ball bearing, twin twisted copper cable, complete all as specified and design to give designed air delivery including greasing, oiling etc all as directed.
Notes for Sl item no. 43 to 47 :- (a) Spare parts found unserviceable / defective will be measured and paid separately under relevant item as supply only. (b) The amount for fixing of new spare parts are deemed to be included in quoted unit rate of above items.
Supply only condenser of capacity 1.5 to 3.15 MFD, 230 volts, 50 Hz AC confirming to IS 1709 complete.
Supply only PVC fan blade of size 200/250 mm complete all as specifed and directed
Supply only PVC fan blade of size 300 mm complete all as specifed and directed
Supply only PVC louver suitable for 200/250 mm complete all as specifed and directed
Supply only PVC louver suitable for 300 mm complete all as specifed and directed
Supply only Metalic louver for 300 mm metalik fan complete all as specified and directed.
Supply only Metalic fan blade suitable for 300 mm metalik exhaust fan complete all as specified and directed.
Supply only exhaust fan motor of size 200/250 mm for replacing unsv one of same cpcacity and same size copper winding size complete all as specified and directed.
Supply only in replace exhaust fan motor of size 300 mm for replacing unsv one of same cpcacity and same size copper winding size complete all as specified and directed.
Supply only PVC insulated flexible wire twin core twisted copper conductor of size 0.75 Sqmm (24 / 0.20) complete.
Repair / maintenance and servicing of non functioining geysers of 25/50/100 ltrs capacity due to any defect like air lock, water leakage in pipe line joints,non functioning of any parts, checking electric connections and making good the loose electric connection and pipe line leakage etc.and making the geysers functional complete all as specified and directed.
Taking down carefully storage type water heater (geysers) of 25 litres capacity for servicing after disconnecting existing water supply and electric connection by unscrewing / cutting of holding bolts / nuts from walls and opening the tank for repair including taking out inner assembly and scraping scale deposite on the surfcae of assembly, cleaning and washing and re-assembling after repairs and fixing the same in its original position and making necessary water supply and electric connection and testing complete all as specified and directed. Note:- The quoted unit rate is deemed to be included taking down of geyser from original position and refixing after repair incl the cost of nut and bolt if any required at site incl necessary cost of rubber gasket in any size complete all as specified and as directed.
Notes for Sl item no 60 :- (a) Spare parts found unserviceable / defective will be measured and paid separately under relevant item as supply only. (b) The rate for fixing of new spare parts are deemed to be included in quoted unit rate of above items.
Supply only copper sheathed and nickel plated heating element 1.5 kW with gasket (ISI marked) suitable for horizontal or vertical type water storage type water heater (Geysers) 15/25 ltr capcity all as specified and directed.
All as per Sl. item no. 62 above but heating element 2 kW complete all as specifed and directed .
Supply only thermostat, suitable for any make & type of geyser 15/ 25 litres capacity horizontal or vertical type complete all as specified and directed.
Supply only indicating lamp for geysers of any type make & capacity all as specified and directed.
Supply & Fixing in repair of unserviceable PVC connection 15mm bore of 450 mm long with brass coupling with washers at both ends and connection to water cooler and water main complete all as specified and directed.Make-Prayagraj/Jyoti
S&F 'C' series MCB SP, 6 to 32 Amps, 240 volts, 50Hz , 10kA complete all as specified & directed.
S&F 'C' series MCB SPN, 40 to 63 Amps, 240 volts, 50Hz , 10kA complete all as specified & directed.
Supply only 15 mm size CP Brass inlet and outlet assembly complete with rubber gasket, nuts, bolts and washers suitable for housing heating elements, thermostat etc. for 25 litre capacity storage type water heater complete all as specified and directed.
Supply only brass ferrule of 15 mm size complete all as specified and directed. Make - Ditz, Racold, Havells
Supply only rubber gasket round / flat suitable for inlet and outlet assembly of any capacity geyser as per sample.
Supply only mild steel expansion fastners 10 mm dia and 100 mm long to walls by drilling complete with washers etc. and making good disturbed surfaces to match with the existing all as specified and directed.
Taking down / dismantling and removing inner stainless steel/ copper tank of geyser (any make), 25 litres capacity and rectification of leakage by welding/ brazing with suitable metal including all necessary denting etc and re-assembling the same including making connections complete all as specified and directed.
S&F metal plug and socket DB, two pin and earth plug, 240 volts and including one 20 Amp MCB SP, C-Curve & including taking down of old/unsv concealed metal box replacing with new, making good cement work and paint complete all as specified and directed.
S&F screwed type Bronze vertical check valve 15 mm bore by cutting and threading of GI pipe including necessary fittings like sockets, unions, elbow, nipples etc. complete all as specified and directed.
S&F screwed type Bronze air release valve 15 mm bore by cutting and threading of GI pipeincluding necessary fittings like sockets, unions, elbow, nipples etc. complete all as specified and directed.
S&F pressure release valve of size 15 mm (safety type) CP brass, ISI marked complete all as specified and directed.
Supply and fixing in repair electric water heater ( geyser) storage type of capacity 15 Ltr , BEE 5 star rated including stainless steel connection pipe for inlet and outlet connection15 mm size 450 mm length complete incl fixing the brick/RR wall with anchor bolting, grouting and making good disturbed surface complete all as specified and directed.
Supply and fixing in repair electric Hammam water heater of capacity 45 Ltr , steel body rect angular /cylindrical type with thermostat for auto cut , Heating element of 2000 watts , CP taps, connecting wire with plug top 15 Amps complete all as specified and directed .
Supply and fixing in repair heating appliances electric rod 2000 watts ( water heating element ) with complete set thermostat and tank nipple complete all as specified and directed.
M&L for repairing of invertor by removing battery bank and connecting lead, removing the carbon deposition , checking the specific gravity of distilled water, cleaning the batteries , refixing the same in battery rack , servicing the invertor assembly , checking output voltages for proper functioning complete all as specified and directed. Note : Distilled water and spare items shall be measured and paid as per relevent items in the schedule .
Supply only distilled water for invertor batteries complete all as specified and directed
Supply and fixing in replacement of battery lead suitable for 12V 180 Ah invertor batteries all as specified and directed
Supply and fix in replacement of invertor tubular battery 12 volt 180 AH complete all as specified and directed
Supply and fixing in repair wave fins room heater 3000 wattts oil filled type , metal body ,03 nos heating stage complete all as specified and directed.
M&L for replacing the heating element of Heat pillar rod 2KW incl opening the outer cover rewiring the connectors compete all as specified and directed.
Supply and fixing in repair tracer wire for anti freezing due to cold weather for PP-R pipes complete all as specifed and directed.
Supply and fixing in replacement of battery terminal brass suitable invertoe batteries all as specified and directed
Routine repair maintenance & Servicing of CENTRAL REVERSE OSMOSIS WATER TREATMENT PLANT Complete with Electrical / Control Panels and all connected Gadgets / Devices including Routine Checking of Metering Equipments like Voltmeter, Ammeter, Flow Meter, Conductivity Meter (TDS Meter) PH Meter, Pressure Meter etc. including removal/replacement of defective parts having capacity of delivering Pure, Safe and Healthy Drinking Water 5000 Ltr/Hr by removing dissolved Solids like Calcium, Magnesium, Sodium Bicarbonate, Chlorides, Sulphides, etc. in Water by 90-95% and reducing Harmful Minerals like Arsenic, Fluorides, Lead, Bacteria, etc. and bring Water Hardness Level to Safe Drinking Water Limits, Skid Mounted type alongwith Routine maintenance of RO Water Supply Pumping Set 3.0 HP capacity Each, complete all as specified and as directed :- NOTE :- (a) The Contractor shall engage One Experienced Technician who will visit at an interval of EVERY 30 DAYS and/or as and when required/directed by the Engineer-in-Charge to examine and repair maint of complete Plant. The Technician will report to the JE E/M and Engineer-in-Charge for his Every Visit min 12 visit through out the contract period , failing which no Payment will be allowed to the Contractor.(b) The Plant shall not remain Non Operation more than 8 HOURS after complaint ( any failure of equipment which causing affect the operation of the plant ) received to you otherwise a recovery @ Rs. 300.00 PER HOUR shall be charged from the Contractor beyond 8 HOURS for Non Operation of Plant.(c) The Quoted Unit Rate includes Labour Only for replacement of any type of Spares & Filters, as and when required basis.(d) The Quoted Unit Rate includes the Cost of Chemicals as recommended by Manufacturer for Flushing/Cleaning the System. (e) The Quoted Unit Rate is inclusive of Periodical Back Wash for every 1-2 months for moderate fouling or as and when required to maintain as per the Treatment Guideline of Plant including Cleaning. (f) The Quoted Unit Rate includes the replacement of Minor Spares like Washers Nylon/ Lead, Teflon Tape, Bolt & Nuts, Gland Packing, Gasket, etc. other than specifically Priced. (g) Major Spares like Micron Filter, Membrane, MCCB, Contactors, Relays incl all electronics components will be Measured and Paid for separately.
Supply and fixing Micron Filter of size 4 Inch dia x 20 Inch Length with Filter capacity upto 1 micron (as approved) and Fixing-in-repairs, complete all as specified and as directed.
Supply and fixing Ultaviolet (UV) ,Ultrafilter (UF) TDS water purifire system for Central RO Plant (as approved)any type of filter as per site requirment and Fixing-in-repairs, complete all as specified and as directed.
Supply and replacement of activated carbon filter for Central RO Plant Make -Aquapura model no. AQUAPURA5000 (as approved) and Fixing-in-repairs, complete all as specified and as directed.
Supply and replacement of RO membrance Central RO Plant Make -Aquapura model no. AQUAPURA5000 (as approved) and Fixing-in-repairs, complete all as specified and as directed.
Supply and fix in repair of overload relay of capacity 9-12 Amps ,rated operational voltage 415 V,50Hz trip class 10A for the RO plant stater motor complete all as spd and directed.
Supply & Fix in repair of Single phase preventor for 2 to 5 HP motor ,voltage 280-415V,3 phase ,50 Hz for RO plant complete all as spd and directed.
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 63 Amps 16KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
M&L for complete rewinding ( copper wire coated with PP insulation material) , servicing and refixing of 415 volts 50 Hz 2 to 5 HP monoblock centrifiugal pumps motor and refixing the same at existing same place and testing incl required accesssories i.e. nuts bolts, washers etc complete all as specified and as directed.Note:- item rate includes dismantling of pumps and transporation of motor from site to workshop and back.
M&L for complete rewinding ( copper wire coated with PP insulation material) , servicing and refixing of 415 volts 50 Hz12.5 to 15 HP monoblock centrifiugal pumps motor and refixing the same at existing same place and testing incl required accesssories i.e. nuts bolts, washers etc complete all as specified and as directed.Note:- item rate includes dismantling of pumps and transporation of motor from site to workshop and back.
M&L for repairing and cleaning of existing water treatment vessel for RO plant and same as material complete filling in vessel and serviceable condition directed by Engr-in-charge
S&F in repair star -delta Starter for capacity 15 HP centrifugal motor of , 415 volts, 50 HZ 3 Phase incl the necessary wiring connection to the pump complete all as specified and directed.
Supply and fix in repair of HDPE (High density Polyethylene) flexible pipes ISI marked SDR 7.4 (PN16) of 50 mm bore confirming to IS code 4984:2026 for water supply incl assessories laid in surface /wall/ floor complete all as spd and directed.
Material and labour in repair of PCC (1:3:6) C-2 using 40mm graded aggergate pedestal for supporting upto the base of main delivery GI pipe line complete all as specified and directed.
Material and labour for Bands,straps,supportsorstays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Taking up/down GI/DI and connection from trenches/ground incl connected fittings/accessories complete of 50 mm dia sizes for re use of serviceable pipes and removing the U/S pipes from site for taking credit
Supply, laying & testing on ground GI pipe medium grade ISI marked of size 50 mm dia with all fittings complete all as specified
Deduct Credit for Demolished/Dismantled material Rs (-) 17,506.50 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
M/S MOHD KHAN (BID ID -3474788)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
TENDER71.pdf
Tender Documents • 1.51 MB
BOQ_823213.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid