Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC JAGADHRI ROAD NEAR MAHAVIR CHOWK YAMUNA NAGAR HARYANA 135003 | YAMUNA NAGAR | YAMUNA NAGAR | HARYANA | 135003 | L1 | Accepted-AOC po issued | |
| 2 | L2₹32.2 L+₹4.3 L (15.5%)Rejected-Finance | L2 | Rejected-Finance higher rates | |
| 3 | L3₹33.0 L+₹5.1 L (18.5%)Rejected-Finance KHASRA NO 981 330 BLOCK 3 BASAI VILLAGE BASAI VILLAGE NEAR BASAI FLYOVER BASAI VILLAGE GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | L3 | Rejected-Finance higher rates |
| Sl No | Description | Qty | Unit | Sharan Radio & Electricals L1 | KANDI ELECTRICAL SOLUTIONS PRIVATE LIMITED L3 | INDUSTRIAL AUTOMATION SYSTEMS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00 | Air Circuit Breaker Panel
1. One panel 1 breakers with following rating: Rating Voltage-415 V. 4 Pole Making capacity: 105kA peak, Shunting trip coil-110 VDC, Thermal Current-1000 Amp. Short time-50kA, Closing coil-110VDC, Breaking capacity-50kA RMS, Control Coil Voltage-110 VDC, Confirms to IEC 60947-2, Rated temp. 55 deg. C
Accessories to be supplied:
a) Digital Metering-ACA and ACV with selector switch
b) Indication Lamp-1set, c) CT and PT No. 3 each, d) Push Button-1 set
e) Interlocking mechanism for protection
f) Energy meter (class 0.2), g) Foundation bolt, h) Ground Fault Protection
11) Overload Protection, j) Delayed short circuit protection k) Short circuit protection, 1) Motorized Mechanism with universal 220V Motor
m) Spring charge signal switch, n) Single phase preventor
o) Mechanical contact erosion indicator, Erection, testing and commissioning shall be in the scope of firm. Any consumable,
Spares/material and T&P required to complete the commissioning work shall be in the scope of firm. Any consumable Old breaker shifted to Hydel store shall be in the scope of firm.
Breaker design should in corporate the present cabling position Cabling position should not change during installation of new breaker. Representative of the firm may please visit the site to check the dimension of breaker and feasibility for installation before filling the tender. | 6 | Nos | 4,64,920 ₹27,89,520 Lowest | 5,50,735.12 ₹33,04,410.72 | 5,36,900 ₹32,21,400 |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
30 Sept 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE MM AND STORES
DCRTPP YAMUNA NAGAR
Supply of Air ckt breaker panel
2025_HBC_457305_1
POM-14073 Supply of Air ckt breaker panel
Open Tender
Miscellaneous Goods
Supply
90 days
DCRTPP YAMUNA NAGAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
₹82,000
Yes
25 Mar 2026
9 Jul 2025
3 Oct 2025
9 Jul 2025
30 Sept 2025
9 Jul 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_535003.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .