Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.1 L+₹1.1 L (7.69%)Rejected-Finance | L2 | Rejected-Finance Second Lowest | |
| 3 | L3₹20.8 L+₹5.9 L (39.4%)Rejected-Finance | L3 | Rejected-Finance Third Lowest | |
| 4 | L4₹21.7 L+₹6.7 L (45.1%)Rejected-Finance PLOT NO 2 INDUSTRY AREA NEAR LAL WARE HOUSE OPP OLD HOUSING BOARD COLONY SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L4 | Rejected-Finance Fourth Lowest | |
| 5 | L5₹24.7 L+₹9.8 L (65.5%)Rejected-Finance SHIVAJI NIWAS VILL CHIMBALHAR P O GEETA PEETH PALAMPUR HP 176061 | KANGRA | HIMACHAL PRADESH | 176061 | L5 | Rejected-Finance Fifth Lowest |
Tender Value
Refer Docs
EMD Value
₹49,000
Closing Date
3 Jan 2022, 9:00 amClosed
Major Sameer Wadekar
Holta Cantt, Palampur
SPL REPAIR FOR AUTOMATION OF ON OFF STREET LIGHT AND SECURITY LIGHT AT PALAMPUR MIL STN
2021_MES_492879_1
GEP/ - /2021-22
Open Tender
Civil Works
Item Rate
180 days
Palampur Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹49,000
Yes
25 Jan 2022
6 Dec 2021
5 Jan 2022
6 Dec 2021
3 Jan 2022
20 Dec 2021
Amount
Dismantling ACSR or AAC conductors from poles and removing unservicable conductor from site to store or credited to contractor complete all as specified and directed.
Dismanting cross arms of MS channel or angle sections etc complete and setting aside for re-use within 50m or credited to contractor complete all as specified and directed.
Dismantling insulators any type, any size, complete all as specified and directed.
Excavation in trenches for poles/cable in any type of soil n.exc 1.5 metres wide and not exc 1.5 metres deep and getting out including dismantling of bricks for cable protection complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance exc 500m but n.exc 1.50 m and depositing where directed at a level n.exc 1.5metres above the starting point complete all as specified and directed.
M&L sand cushioning to underground cable provided with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable. The top layer of 15cm shall be punned to 10 cm (total 18 cm) complete all as specified and directed.
M&L sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick complete all as specified and directed.
S&F 40mm bore light grade GI tubing for cable protection as in road crossing, along poles, walls, floors and drain etc complete all as specified and directed.
Supply and fixing cable junction boxes IP 66/67 Weather proof of dimentions 205 x 255 x 112 for 10-25 Sqmm with four terminals outdoor installation( with knockouts for cable entry ) complete all as specified and directed. Make: Hensel, Cat Part No KF2525G or equivalent as approved by GE
Supply and fixing cable junction boxes IP 66/67 Weather proof of dimentions 155x210x92 for 10-16sqmm with four terminals outdoor installation ( with knockouts for cable entry) complete all as specified and directed. Make: Hensel, Cat Part No KF1616G or equivalent as approved by GE
Supply and fixing cable junction boxes IP 66/67 Weather proof of dimentions 155x210x92 for 4-10 sqmm with four terminals outdoor installation ( with knockouts for cable entry) complete all as specified and directed. Make : Hensel, Cat Part No KF1010G or equivalent as approved by GE
Taking out old unserviceable LT cable of any size from trenches or on poles etc complete all as specified and directed.
Material and labour twin core flexible copper cables of size 1 Sqmm 1100 Volts PVC insulated & sheathed with PVC conduit of 20 mm bore for connection from Junction box to street light fitting including taking down existing unserviceable cable and conduit complete all as specified and directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volts grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 25 sq.mm 4 core complete all as specified and directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volts grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 10 sq.mm 4 core complete all as specified and directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 10 sq.mm 2 core complete all as specified and directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 6 sq.mm 2 core complete all as specified and directed.
S&F timelite Distribution Board 32 Amp, 3 pole, 230 V, 50 Hz with Astronomical time switch according to IEC 60730-1 with text based programming concept. The time switch should be microprocessor based programmable having 2 channels and should work on the principle of daily calculations of sunrise and sunset by programming the date, time and positioning coordinates (Longitude and Latitude). The switching ON and switching OFF times should be adjustable asymmetrically for ±120 Minutes (Offset) including taking down the unserviceable timelite distribution board complete all as specified and directed. Make:- Indo Asian/Schneider/Hager/ Legrand/ Havell's
Supply, installation, commissioning and testing LT feeder pillar box outdoor type of size 0.90 mtr x.0.50 mtr x 0.60 mtr factory fabricated made out of MS sheet of thickness 3.15 mm with front door openable with locking arrangement mounted on angle iron legs made out of angle iron size 40 mm x 40 mm x 6 mm, 1.0 mtr long, 0.50 mtr above ground level and 0.50 mtr embedded in PCC blocks 1:2:4 type B1 using 20mm graded crushed stone aggregate of size 0.30 mtr x 0.30 mtr x 0.50 mtr-04 Nos, duly painted with two coats of synthetic enemel paint over a coat of red oxide primer, complete with 200 Amps rated copper bus bar LED phase indicators, suitable for 3 phase 4 wire supply system with MCCB 63 Amp 4 pole breaking capacity 16 KA-01 No, duly drilled holes for cable connection mounted on epoxy based post insulators all as required at site, complete all as specified and directed including taking down the U/S feeder pillar box.
Taking down old unserviceable LT panel board of any specification and size, supply, install, testing & commissioning of CPRI approved LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire , 50 Hz , AC supply system having busbar chamber made out of size 60 cm x 60 cm x 30 cm with angle iron of size 40 x 40 x 5mm with copper bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators. The panel shall be factory made, double door, made out of 3.15 mm thick MS Sheet (CRCA) totally enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of sie 40X40X6 mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable etc all as directed at site and comprising of the following:-
(a) MCCB 200 A, 4P, 415 Volts AC supply , thermal magnetic release type 35/36 KA-01 No (b) MCCB 63A, 4P, 415 Volt 25 KA thermal magnetic relase type -04 Nos. (c) Timelite -110 A 3 Pole, 230 V Digital time switch Make : indoasian Cat part No : TL110080-01 Nos (d) Panel mounted multi function meter for measuring Voltage (0-500 Volts), Current (0- 100 Amps) and frequency-01 No (e) RYB neon indicating lamp panel mounting type (Set of three ) - 01 N0. (f) Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses (g) Cable entry gland and two no earthing terminal
Material and Labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32X6 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion including taking down the unserviceable earthing.
M/s Sheetal Associates
dinesh enterprises
M/S ASHWANI KUMAR AND COMPANY
MM Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .