| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC 1008 LASKARHAT FLAT 2A 2ND FLOOR KOLKATA 700107 | KOLKATA | KOLKATA | WEST BENGAL | 700107 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹18.1 L+₹46,728 (2.66%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹18.4 L+₹83,787 (4.76%)Rejected-Finance 32 A SWAMI SATYANANDA SARANI BARANAGAR | L3 | Rejected-Finance Being L3 |
| Sl No | Description | Qty | Unit | M/S. GOPAL ELECTRICALS L1 | SARKAR ENTERPRISE L3 | MAHALAXMI ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying and fixing 415V, 125A, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S&F 3nos .DIN type HRC fuse as per rating. ( Make- L&T / Siemens/ABB) (For ADJ-I Building) | 1 | Each | 8,518 ₹8,518 Lowest | 8,923 ₹8,923 | 8,743 ₹8,743 |
| 2.00 | Supplying and fixing 415V, 63A, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S&F 3nos .DIN type HRC fuse as per rating ( Make- L&T / Siemens/ABB) (For ACJM Building) | 1 | Each | 4,747 ₹4,747 Lowest | 4,973 ₹4,973 | 4,873 ₹4,873 |
| 3.00 | Supplying and fixing 415V, 32A, TPN SFU with sheet steel enclosure on angle frame on wall with nuts bolts etc incl. S&F 3nos .DIN type HRC fuse as per rating ( Make- L&T / Siemens/ ABB) ( for ADJ-II Building, FTC-II Building, JM Building) | 3 | Each | 3,636 ₹10,908 Lowest | 3,809 ₹11,427 | 3,732 ₹11,196 |
| 4.00 | Supplying and fixing of 6-Way Vertical TPN MCB Distribution board (Upto 160A) for MCCB incomer with IP-43 metal double door protection on angle iron frame on wall & mending good the damages to original finish ,provided with insulated vertical phase bus-bars,neutral bar/s with shroud/s, earth bar/s, sticking saddles,colour coded interconnecting wire set, ckt identification lables, cement spill protector, etc. & provision for earthing attachment having 125 A 4 Pole MCCB as incomer and 4 nos. 63A TP MCB and 6 nos. 6-32A SP as outgoing etc. (Make-Legrand/ Seimens/ABB) (For ADJ 1) | 1 | Each | 19,366 ₹19,366 Lowest | 20,288 ₹20,288 | 19,878 ₹19,878 |
| 5.00 | S&F 415 V, 16-32A per way, 4 way TPN MCBDB with SS enclosure, double door with IP 42/43 protection with 4 pole 63 Amp MCB isolator as incomer and C curve 10KA SPMCBs 12 nos 16-32amp as outgoing, concealed in wall after wall cutting and mending good the damages to original finish incl. interconnection with suitable size of Cu wire, neutral link and earthing attachment. (Make- ABB/ Seimens/ Legrand). (for ADJ-1 Building) | 1 | Each | 5,859 ₹5,859 Lowest | 6,138 ₹6,138 | 6,014 ₹6,014 |
| 6.00 | S&F 415 V, 16-32A per way, 4 way TPN MCBDB with SS enclosure, double door with IP 42/43 protection with 4 pole 32 Amp MCB isolator as incomer and C curve 10KA SPMCBs 12 nos 16-32amp as outgoing, concealed in wall after wall cutting and mending good the damages to original finish incl. interconnection with suitable size of Cu wire, neutral link and earthing attachment. (Make- ABB/ Seimens/ Legrand). (1 no for ADJ-II Building, 01 nos for FTC-II Court Building, 01 no for JM building) | 3 | Each | 5,636 ₹16,908 Lowest | 5,904 ₹17,712 | 5,785 ₹17,355 |
| 7.00 | S&F 415 V, 16-32A per way, 6 way TPN MCBDB with SS enclosure, double door with IP 42/43 protection with 4 pole 63 Amp MCB isolator as incomer and C curve 10KA SPMCBs 18 nos 16-32amp as outgoing, concealed in wall after wall cutting and mending good the damages to original finish incl. interconnection with suitable size of Cu wire, neutral link and earthing attachment. (Make: ABB/Seimens/ Legrand). (for ACJM Court Building) | 1 | Each | 7,624 ₹7,624 Lowest | 7,987 ₹7,987 | 7,825 ₹7,825 |
| 8.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Polycab/RR) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC ( For AC ) | 530 | RM | 171 ₹90,630 Lowest | 179 ₹94,870 | 176 ₹93,280 |
| 8.01 | 2x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC (For existing SPNDB from New PDB at ADJ -II Building, JM Building and FTC-II Building) | 30 | RM | 222 ₹6,660 Lowest | 232 ₹6,960 | 228 ₹6,840 |
| 9.00 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2 x 4 sqmm + 1 x 2.5 sqmm | 48 | Set | 23 ₹1,104 Lowest | 24 ₹1,152 | 23 ₹1,104 Lowest |
Tender Value
Refer Docs
EMD Value
₹37,273
Closing Date
11 Mar 2026, 1:00 pmClosed
EE, North 24 Parganas Electrical Div.P.W.Dte.
OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION, TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOLKATA 700 059
SITC of RACs with allied E.I. work in the all Ejlas and Chambers at Bongaon Sub-Divisional Court, North 24 Parganas.
2026_WBPWD_1009620_1
WBPWD/EE/N24/EL/e-NIQ- 181/25-26
Open Tender
MISC ELECTRICAL WORKS
Item Rate
21 days
Bongaon
Please refer Tender documents.
4 documents required · 4 mandatory
₹37,273
North 24 Parganas Electrical Division, P.W.Dte.
14 Oct 2026
18 Feb 2026
13 Mar 2026
18 Feb 2026
11 Mar 2026
25 Feb 2026
24 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing 415V, 125A, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S&F 3nos .DIN type HRC fuse as per rating. ( Make- L&T / Siemens/ABB) (For ADJ-I Building) | 1 | Each | 100 | ₹100 |
| 2 | Supplying and fixing 415V, 63A, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S&F 3nos .DIN type HRC fuse as per rating ( Make- L&T / Siemens/ABB) (For ACJM Building) | 1 | Each | 101 | ₹101 |
| 3 | Supplying and fixing 415V, 32A, TPN SFU with sheet steel enclosure on angle frame on wall with nuts bolts etc incl. S&F 3nos .DIN type HRC fuse as per rating ( Make- L&T / Siemens/ ABB) ( for ADJ-II Building, FTC-II Building, JM Building) | 3 | Each | 102 | ₹306 |
| 4 | Supplying and fixing of 6-Way Vertical TPN MCB Distribution board (Upto 160A) for MCCB incomer with IP-43 metal double door protection on angle iron frame on wall & mending good the damages to original finish ,provided with insulated vertical phase bus-bars,neutral bar/s with shroud/s, earth bar/s, sticking saddles,colour coded interconnecting wire set, ckt identification lables, cement spill protector, etc. & provision for earthing attachment having 125 A 4 Pole MCCB as incomer and 4 nos. 63A TP MCB and 6 nos. 6-32A SP as outgoing etc. (Make-Legrand/ Seimens/ABB) (For ADJ 1) | 1 | Each | 103 | ₹103 |
| 5 | S&F 415 V, 16-32A per way, 4 way TPN MCBDB with SS enclosure, double door with IP 42/43 protection with 4 pole 63 Amp MCB isolator as incomer and C curve 10KA SPMCBs 12 nos 16-32amp as outgoing, concealed in wall after wall cutting and mending good the damages to original finish incl. interconnection with suitable size of Cu wire, neutral link and earthing attachment. (Make- ABB/ Seimens/ Legrand). (for ADJ-1 Building) | 1 | Each | 104 | ₹104 |
| 6 | S&F 415 V, 16-32A per way, 4 way TPN MCBDB with SS enclosure, double door with IP 42/43 protection with 4 pole 32 Amp MCB isolator as incomer and C curve 10KA SPMCBs 12 nos 16-32amp as outgoing, concealed in wall after wall cutting and mending good the damages to original finish incl. interconnection with suitable size of Cu wire, neutral link and earthing attachment. (Make- ABB/ Seimens/ Legrand). (1 no for ADJ-II Building, 01 nos for FTC-II Court Building, 01 no for JM building) | 3 | Each | 105 | ₹315 |
| 7 | S&F 415 V, 16-32A per way, 6 way TPN MCBDB with SS enclosure, double door with IP 42/43 protection with 4 pole 63 Amp MCB isolator as incomer and C curve 10KA SPMCBs 18 nos 16-32amp as outgoing, concealed in wall after wall cutting and mending good the damages to original finish incl. interconnection with suitable size of Cu wire, neutral link and earthing attachment. (Make: ABB/Seimens/ Legrand). (for ACJM Court Building) | 1 | Each | 106 | ₹106 |
| 8 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Polycab/RR) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC ( For AC ) | 530 | RM | 107 | ₹56,710 |
| 8.01 | 2x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC (For existing SPNDB from New PDB at ADJ -II Building, JM Building and FTC-II Building) | 30 | RM | 108 | ₹3,240 |
| 9 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2 x 4 sqmm + 1 x 2.5 sqmm | 48 | Set | 109 | ₹5,232 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.66 MB
Tendernotice_2.pdf
PDF • 0.45 MB
BOQ_2478636.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .