| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹16.2 L+₹35,018 (2.20%)Rejected-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹18.2 L+₹2.3 L (14.2%)Rejected-AOC | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹35,800
Closing Date
31 May 2023, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIRS MAINTENANCE OF COOLING APPLIANCES DESERT COOLERS CEILING FANS WALL FANS AND GEYSERS AT MIL STN GANDHINAGAR
2023_MES_593043_1
GE(A)/GNR/TOKEN/04 of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹35,800
Yes
20 Jul 2023
3 May 2023
2 Jun 2023
3 May 2023
31 May 2023
19 May 2023
3 May 2023 - 17 May 2023
Amount
M&L for Repair / maintenance of Air conditioner of any type with replacement of defective minor spare parts such as connector, burn contol copper cable, copper himbles,cutting, grinding and welding etc or if any other required minor spares including taking out old u/s Air conditioner with disconnecting electrical / mechanical connection and testing after repair entire satisfaction of Engineer-in-Charge , fixing to its original location complete with making electical connection complete all as specified and directed.
Repair and Maintenance of flame proof split AC 1.5 ton with dismentling of assembly cleaning the body with air blower, replacement of electrical contactor set, cleaning of filter for internal unit, replacement insulation for cooling pipe, checking of electrical connection and tightning of the same and testing complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing), suitable for working on single phase, 50 HZ AC supply in window/split type A/C of appropriate make including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed for 1.5 TR Capacity, complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing), suitable for working on single phase, 50 HZ AC supply in window/split type A/C of appropriate make including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed for 2 TR Capacity, complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in water cooler of 40/80 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/8 HP (165 to 210 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/6 HP (265 to 310 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 310/320 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, Electronic PCB suitable for split/windows AC of any capacity as per sample complete all as specified and directed.
M&L, in repair, starting relay of Refrigerator 1/8 to 1/6 HP capacity including making necessary electric connections complete all as specified and directed.
S&F, in repair, overload protector of Refrigerator and Deep freezer 165 Ltr to 310 Ltr complete all as specified and directed.
S&F, in repair, Thermostate suitable for Refrigerators & deep freezer up to 310 Ltrs complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for window/split type A/C of capacity 1.5 & 2 TR and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 36/45/50 MFD complete all as specified and directed.
S&F,in repair, Starting capacitor 230 Volt, 80-100MFD suitable for AC's complete all as specified and directed.
S&F, in repair, starting contactor for split AC of any capacity as per existing sample complete all as specified and directed.
S&F, in repair, starting relays with overload suitable for Split /window AC as per existing sample complete all as specified and directed.
S&F, in repair, thermostate as per existing sample for Split /window AC complete all as specified and directed.
S&F, in repair, air filter as per sample for Split/window AC of any capacity complete all as specified and directed.
S&F, in repair, indoor unit blower motor for Split AC of any capacity as per existing sample complete all as specified and directed.
S&F, in repair, outdoor unit blower motor for Split AC of any capacity as per existing sample complete all as specified and directed.
S&F, in repair, swing motor for Split AC of any capacity as per existing sample complete all as specified and directed.
S&F, in repair, PVC/aluminium blower impeller for Split /window AC as per existing sample complete all as specified and directed.
S&F, in repair, suction/Discharge service Valve as per sample for Split AC of any type complete all as specified and directed.
S&F, in repair, Cooling / condenser coil suitable for split type AC of any type complete all as specified and directed.
Disconnecting & taking out of split AC indoor and out door unit by cutting cutting of copper tube and disconnecting of electric cable & shifting of indoor/outdoor unit to another or same location with refilling refrigerant gas and fixing & testing after connecting all the parts in position complete all as directed by Engr-in-Charge complete all as specified and directed.
S&F, in repair, factory made MS bracket duly painted suitable for split AC outdoor unit of any type complete all as specified and directed.
S&F, in repair, old u/s remote control suitable to existing window/split type ACs (as per sample) complete all as specified and directed.
S&F, in repair, 6 pin, 5/16 amp multiple switch socket combination with PVC Box complete all as specified and directed.
S&F, in repair, switch socket combination, 2 in 1, 3/5 pin, 5/6 Amps, 240 volt, flush type with PVC box complete all as specified and directed.
S&F, in repair, 10-20 Amp MCB SP complete all as specified and directed.
S&F, in repair, 5 Amp plug top complete all as specified and directed.
S&F, in repair, Plug top (male) 16 Amps for sheet metal enclosure. (As per sample) complete all as specified and directed.
S&F, in repair of old u/s round PVC insulated stranded copper conductor 3 core 1.5 Sq mm 1100 volt grade, connected & testing complete all as specified and directed.
S & F, in repair of old u/s nitrile rubber insulation material for split air conditioner copper tube complete all as specified.
S & F, in repair, Plywood 4 mm thick, grade BWR, type BB, fixing for window AC / desert cooler as per existing windows size complete all as specified and directed.
S&F, in repair, replacement MCB single pole & neutral neutral 40 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified & as directed.
S & F, in repair, of old u/s filter flare nipple for water cooler / Acs complete all as specified and directed.
S & F, in repair, old unsv Copper Pipe ½" as per sample complete all as specified and directed.
S&F, in repair, old unsv Copper Pipe ¼" as per sample complete all as specified and directed.
S & F, in repair, old unsv copper pipe 5/8" as per sample complete all as specified and directed.
M & L for Repair / maintenance / Servicing of Water coolers of any type with replacement of defective minor spare parts such as connector, burn contol copper cable, copper thimbles etc or if any other required minor spares at Gandhinagar Mil stn including taking out old u/s water cooler with disconnecting electrical / mechanical connection and transporting to workshop for repairing & testing after repair entire satisfaction of Engineer-in-Charge and transporting back , fixing to its original location complete with making electical connection complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for Water Cooler of capacity 40/80 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
S & F, in repair, starting relay for water cooler of any type complete all as specified and directed.
S & F, in repair, overload for water cooler of as per existing sample complete all as specified and directed.
S & F, in repair, running capacitor 10/15/20 mfd for water cooler of any type complete all as specified and directed.
S & F, in repair, starting capacitor 40/60, 80/100 mfd for water cooler of any type complete all as specified and directed.
S & F, in repair, thermostat as per existing sample complete all as specified and directed.
S & F, in repair, waste water PVC pipe with clamp suitable to existing size complete all as specified and directed.
Supply and fixed in repairpush cock, 15mm bore made of brass chromium plated self closing, vertical type complete all as specified and directed.
S&F, in repair, connectors made of brass with chromium plated suitable for water cooler having cooling capacity 40 litres per hour complete all as specified and directed.
S&F, in repair, fan blade for condensing fan motor suitable for water cooler having cooling capacity 40/60 Ltr/Hr complete all as specified and directed.
S & F, in repair, chromium plated water tray basin for water cooler match to the existing size complete all as specified and directed.
Supply and fixing in repair MCB Triple pole 32 to 63 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and as directed.
Supply and fixing in repair 15mm dia PTMT float ball valve for water cooler and desert cooler complete all as specified and as directed by Engr-in-Charge.
S&F, in repair, PVC connection pipe 15 mm dia 450/600 mm long with brass fly nut at both ends for water cooler and desert cooler complete all as specified and as directed by Engr-in-Charge.
M & L for Repair to water cooler body by replacing worn out metal sheet, with S/S metal sheet and frame of existing thickness at bottom and side with S/S metal sheet and frame of existing thickness at bottom and side including welding/soldering where ever applicable. Painting with one coat of anti corrosive paint and two coats of synthetic paint complete all as specified and as directed by Engr-in-Charg
S & F, in repair, cooling coil evaporator assembly as per sample for refrigerator of any capacity complete all as specified and directed.
S & F, in repair, condensing coil assembly as per sample for refrigerator of any capacity complete all as specified and directed.
S & F, in repair, thermostat switch as per sample for Refrigerator or Deep freezer of any capacity complete all as specified and directed.
S & F, in repair, Starting relay with OLP as per sample for Refrigerator or Deep freezer of any capacity complete all as specified and directed.
S & F, in repair, timer as per sample for double door refrigerator of any capacity complete all as specified and directed.
S & F, in repair, blower motor with fan as per sample for double door refrigerator or Deep freezer of any capacity complete all as specified and directed.
S & F, in repair, freezer chest door as per sample for any capacity refrigerator complete all as specified and directed.
S & F, in repair, transparent vegetable tray complete set / other tray as per sample for any capacity refrigerator complete all as specified and directed.
S&F, in repair, Electronic PCB 200 to 300 Ltr capacity as per sample refrigerator complete all as specified and directed.
S&F, in repair of old u/s capillary tube (copper) match to the existing size & length including taking down and removal of old unserviceable one complete all as directed.
S&F, in repair, old u/s filter flare nipple for refrigerator / deep freezer of any capacity complete all as specified and directed.
S&F, in repair, three pin plug with PVC flexible cable lead as per sample for desert cooler complete all as specified and directed.
S&F, in repair, piano type switch 5 amp complete all as specified and directed.
S&F, in fabrication frame work for voltage stabilizer, water cooler, window AC, desert cooler made from angle iron, flat iron, square tube, wire mesh, GI sheet etc. quality confirming to Fe-410-W or Gde-E 250 quality -A with including drilling holes, cutting & welding nut & bolts etc. complete with locking arrangement , grouting in wall / floors etc. and make good the disturbed surfaces incl required cement /bricks etc complete all as directed and specified by Engr-in-Charge
M&L for refrigerent charging with R-22/R-134 for Deep Freezer of capacity 165 Ltr to 320 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
S&F, in repair, GI sheet side grill match to existing size of desert cooler complete all as specified and directed.
S&F in repair side supporting columns made out of 20 gauges PGI sheet of size 80x80x800 mm including necessary nut, bolts etc including painting to match with the existing desert cooler complete all as specified and directed.
S&F, in repair, condenser unit complete suitable for 40 Ltr/Hr capacity water cooler including gas charging, flushing out the system, brazing, welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge
S&F, in repair, side penal made out of PGI Sheet with suitable handles including painting to match with the existing desert cooler complete complete all as specified and directed.
S&F, in repair, top cover made out of PGI Sheet including painting to match with the existing desert cooler complete all as specified and directed.
S&F, in repairs, water lift submerssible pump (ISI Marked) suitable to operate on 230V AC supply of desert cooler and connecting electically, complete all as specified and directed.
S&F, in repair, fan motor (ISI Marked), 1/10 HP, 230 volt single phase of existing desert cooler with fixing clamps, complete all as specified and directed
S&F, in repair, wood wool pads, superior quality, suitable size of existing desert cooler, complete all as specified and directed
S&F, in repair, desert cooler fan blade suitable for 4000/ 5000 cum desert cooler motor complete all as specified and directed.
S&F, in replair, PVC pipe 15 mm dia heavy duty for Desert Cooler Pump complete.
S&F, in Repair, of voltage stabilizer spare parts of upto 5 KVA of any type such as transistor, PCB, diode, transformer, preset ic , volt meter, ampmeter, indicator lamp, socket outlet and any other parts as required for proper functioning of stabilizer complete along with testing and transportation charges from site to workshop complete all as directed
Opening (De-assembling) of the ceiling fan, 1200mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of appropriate gauge, slot insulation, heat varnishing, greasing and re-assembling including replacement of split pin and flexible twisted copper cable of 23/0.0076 gauge and testing complete all as specified and directed. Note:- (i) Contractor shall collect the Ceiling fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge.The spare part shall be measured & paid separately under respected, items below.
S&F capacitor of 2.5 Mfd suitable for ceiling fan.
S&F ball bearing suitable for 1200mm sweep ceiling fan.
S&F gun metal bush suitable for 1200mm sweep ceiling fan of appropriate make.
S&F, in repair, PVC canopy set (Upper & Lower) suitable for ceiling fans complete all as specified and directed.
S&F, in repair, MS hanging clamp with rubber bush, bolts, nuts & washer with split pin suitable for 1200 mm sweep ceiling fan complete all as specified and directed.
Taking down of ceiling fan 1200 mm sweep from existing position/hook, cleaning, servicing, greasing, oiling and re-fixing on same position complete all as specified and directed.
S&F, in repair, PVC body, Fresh air fan, AC single phase 230 volt 50 Hz, 250 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
S&F, in repair, PVC body, Fresh air fan, AC single phase 230 volt 50 Hz, 300 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
S&F, in repair, PVC body, Fresh air fan, AC single phase 230 volt 50 Hz, 200 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
S&F, in repair, Metal body, Exhaust fan , AC single phase 230 volt 50 Hz, up to 450 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
Opening (De-assembling) of exhaust fan any size up to 450 mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling and testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge.The spare part shall be measured & paid separately under respected, items below.
S&F capacitor of 4.0 Mfd suitable for exhaust fan.
S&F ball bearing suitable for any size up to 450 mm sweep exhaust fan complete.
S&F gun metal bush suitable any size up to 450mm sweep exhaust fan complete.
Taking down exhaust fan of any size upto 450 mm sweep from existing position, cleaning, servicing, greasing, oiling and re-fixing on same position complete all as specified and directed.
Disconnecting carefully water and electric connection from storage type water heater of 25/50 ltr cap of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by de-scaling chemical compound including soldering, brazing the inner tank if required, re-assembling the geyser after cleaning & servicing and re-fixing in existing position complete all as specified and directed. Note:- (i) Heating element, thermostat, air release valve, safty valve, indicating lamp and syphone assembly and spare part shall be measured and paid separately under relevant items as given below. (ii) The rate quoted are deemed to include cost of soldering/brazing work if required at site.
S&F,in repair heating element of 1.5 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed.
S&F, in repair, heating element of 2.0 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed.
S&F, In repair , thermostate assembly for geyser, tempetrature setting up to 85 degree centigrade, ISI marked complete all as specified and directed.
S&F,in repair indicating lamp suitable for existing slot of geyser complete all as specified and directed.
S&F, in repair, 15mm bore 600mm long heavy dutry , Stainless steel connection, high density suitable for temperature upto 100 degree complete all as specified and directed.
S&F, in repair,semi circular bottom cover plate of 25/50 ltr capacity geyser duly painted of appropriate make complete all as specified and directed.
S&F in repair wall mounting fan 400 mm sweep electrically operated swing type suitable for working on 240 v single phase AC supply complete all as specified and directed.
S&F in repair of metal fastner 12mm dia for fixing geyser complete all as specified and directed.
S & F in repair 3 pin plug top of 15/16 Amp, 240 V AC supply ISI marked of make Bajaj/ Anchor or equivalent as specified in Appx 'C'
S & F in repair 3 pin plug top of 5 Amp, 240 V AC supply ISI marked of make Bajaj/ Anchor or equivalent as specified in Appx 'C'
S&F ,in repair, PVC Insulated and PVC sheeted cable 3 core, 2.5 Sqmm, multistandard copper conductors for water coolers/ refrigerators complete all as specified and directed.
Gyser assembly 8/9 holes Complete all as apecified and directed.
S & F in repair DBOXx MCB protected socket pvc plastic with single pole MCB 25 Amps complete all as specified and directed
M & L in replacement sub-main wiring with 2 single core 2.5 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in and including PVC casing caping ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire drawn through and connected to main switch/ DB and testing on completion. Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length.
S&F, in repairs, 15A switch socket combination alongwith PVC top cover and sunken box complete all as specified and directed by Engineer-in-Charge.
S & F in repair Auto cut off electric water heater geyser temperature controlling sensor any capacity complete all as specified and directed
M & L for painting of ceiling fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc complete all as specified and directed by Engineer-in-Charge.
ARTI CONSTRUCTION
SATISH ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .