| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹27.6 L+₹3.4 L (14.0%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹29.8 L+₹5.6 L (23.1%)Rejected-Finance D NO 71 31 96 6 ASRR COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹30.5 L+₹6.3 L (26.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
₹30.3 L
EMD Value
₹60,600
Closing Date
5 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
ADDITION AND ALTERATION TO BLDG. NO. P-47A/1 UNDER LBW, AS AND AS TO BLDG NO. P-185 AT NAVAL STATION BHEEMUNIPATNAM UNDER GE(P) NAVY KALINGA
2022_MES_500158_1
GE (P)/N/K/8850 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a (i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹60,600
Yes
24 Mar 2022
7 Jan 2022
7 Feb 2022
7 Jan 2022
5 Feb 2022
22 Jan 2022
60 days
Amount
Taking down old tarfelt treatment from roof surfaces including plaster etc.
Demolition of mud phuska treatment of any thickness including plastering and leaping plaster of any thickness and removing.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3.
10mm thick screed bed on concrete surface in cement mortar 1:3 with water proofing compound before carrying out water proofing treatment over roof slab. Note: WPC will be measured and paid separately as supply only
Normal water proofing treatment on roof slab portion consisting with the following operation : (i) Cleaning surface by wire brushes broom, removing dust and applying with bitumen primer conforming to IS 3384-1986 @ 0.50 kg per sqm (ii) Applying a tack coat of bitumen 85/25 @ 1.2 kg per sqm for water proofing membrane (iii) Applying of polymeric water proofing membrane weight not less than 3 kg per sqm over entire area with overlapping and sealed. (iv) Again applying hot bitumen 85/25 @ 1.2 kg per sqm over water proofing membrane (v) Applying a bituminous aluminium primer/ paint 0.10 kg per sqm.
GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (n.exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre size of grid of GI frame 600 x 600mm to receive ceiling board.
Gypsum board 12mm thick in ceiling fixed with screw, cut opening for light and including 75 to 100 mm wide decorative gypsum corner beading finished smooth.
4 mm thick E-board ceiling of size 600 mm x 600 mm fixed to timber/ GI/ aluminium frame work with screws in ceiling flat or sloping
Dismantling floors, hearth or wall tilling including cement mortar bedding (but not backing), removing rubbish off the premises.
Stone wall cladding coloured tiles of size 300 x 150 x 7-8 mm thick (Ist quality) as in vertical surface such as wall/ skirting/ dado set in neat cement slurry and pointed in coloured cement to match the surface, including 10mm thick backing coat to receive tiles in CM (1:3) finished even and rough.
Vitrified ceramic light shade tiles 10mm thick (Square/Rectangular) polished area of each tiles n.exc 0.36 Sqm as in floor etc. set and jointed in neat cement slurry and pointed in white and coloured cement to match the surface over and including screed bed layer 15 mm thick in CM 1:4.
Vitrified ceramic light shade tiles 10mm thick (Square/Rectangular) polished area of each tiles n.exc 0.36 Sqm as in skirting etc. set and jointed in neat cement slurry and pointed in white and coloured cement to match the surface over and including 10 mm thick backing coat in CM 1:3.
Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 (Ist quality) as in floor set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 15mm thick screed bed in CM 1:4 finished even and rough.
Glazed ceramic coloured tiles 300 x 450 x 6-7 mm thick (Ist quality) as in vertical surface set in neat cement slurry and pointed in coloured cement to match the surface, including 10mm thick backing coat to receive tiles in CM (1:3) finished even and rough.
Designer rubber moulded chequered cement concrete tiles 30 cm x 30cm x 25 cm thick conforming to IS-13801-1993 with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including 20mm thick screed bed in cement mortar (1:4).
20 mm thick granite (of any type) work table rubbed and polished in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 m thick screed bed in Cement mortar (1:4).
Rounding edges of stone slab, such as cooking platform and other similar situation.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm below or above ground level including removal of demolished materials from work site.
Demolition of reinforced cement concrete in roof, floor (other than ground floor) beams, staircase, chajja and similar suspended works (reinforcement cut as required to facilitate demolition).
Plain cement concrete type B-1,1:2:4 (using 20mm graded stone aggregate) as roof kerbs, mud stops, chajjas rounded or chamfered on edges .
40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub base of floors.
Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, bed etc.
Reinforced cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roof, landings, deck slabs and in shelves and the like.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws.
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof ridge/ gutter/ cladding to wall, fixed with self tapping screws.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 including gusset plate, including erection of vertical supports for holding purlins, rafters, base plates, nuts & bolts etc.
Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming to Fe-410W (Gde-E-250) quality-A
12 mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed the both ends each screwed ends to be fitted with washer and one hexagonal or square nut exc 15 cm but n.exc 22.5cm long.
Mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410 W (Gde-E-250) quality A.
Applying two coats of high build chlorinated rubber paint over two coats of epoxy micaceous iron oxide paint protection with total thickness not less than 100 microns over two pack zinc rich epoxy primer with total thickness not less than 45 microns including preparation/ cleaning of steel surfaces
2.5 to 3.0 mm thick metallic finish silver aluminium plastic composite panel fixed to steel/ aluminium frame including all necessary fixing arrangements
UPVC window, (unplastisized poly-Vinyl Chloride) sliding windows multi-chambered and stiffened framed windows using 88 mm x 52mm size sections all-round as main frames and shutters made with profile sections of size 57mm x 42mm, including the cost and fixing of 5mm thick clear float glass in shutters and stainless steel wire mesh shutters shall have well defined welded corner joints without any gaps, fixed the window unit to the existing masonry with anchor fasteners as required. The shutters shall have necessary handles and other associated fittings to facilitate smooth operation. Both the frames and the shutters shall be reinforced with Gl profiles of thickness 1.25mm the entire window is covered with MS powder coated tube of size 40mm x20mm all-round the frame the frame section, 10mm square bars horizontally placed at 120mm C/C and suitably placed vertically to avoid buckling and providing structural strength, minimum weight shall be 10kg/Sqm and fixed to UPVC frames with suitable fasteners. The gaps between the window tames and masonry walls shall be filled with silicon or with any other suitable filler materials.
Supply only 4mm thick plain sheet glass & fixed in aluminium frame work.
10 mm thick toughened glass for door shutter with necessary SS fancy handle, locking arrangement
Aluminium XPM wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty
10mm thick plain sheet glass ordinary quality for partition work & fixed in aluminium frame work.
Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc, (minimum thickness of powder coating 50 micron).
Aluminium extruded section door closer hydraulically regulated, designation No. 2 universal type, suitable for door shutters of 701 to 850mm in width and of weight between 36 to 60 Kg.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, as per specification & drawing
125mm size MS butt hinges medium weight cold rolled fixed to frame.
150mm size aluminium handles, cast type, anodised.
200 mm long , aluminium alloy barrel tower bolts anodised extruded section ISI marked.
300mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy.
Stainless steel, curtain rod, 25 mm dia for door and window opening.
Fancy type CP knob round for fixing curtain rod.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sided and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surface of concrete.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams finished rough surfaces of concrete.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, FRLS cable etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft /loose soil.
Excavation in trenches n. exc 1.5 mtr wide and exc. 1.5mtr in depth and n. exc 3.0 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sqm on plan and getting out in soft / loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick in soft /loose soil.
Removing excavated materials (soil) exc 250mm and n. exc 500m and depositing where directed at a level n.exc 1.5m above the starting point.
Reinforced cement concrete (1:1.5:3) nominal mix using 20mm graded aggregate as in foundations, including rafts, footings, plinth beams, bases for columns, basement slab, under-reamed piles etc..
Reinforced cement concrete (1:1.5:3) nominal mix using 20mm graded aggregate as in lintel beams, roof beams and the like etc.
TMT bars 10mm dia and over, as reinforcement. cut to length, bent to shape required including cranking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia.
TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length , bent to shape required including cranking bending hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips.
PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete.
Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc built in cement mortar.
Demolition of Brick work or stone boulders masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles.
Brick work with fly ash bricks straight or curved on plan exc 6.0 mtr mean radius built in cement mortar (1:6).
Brick Work in with fly ash Bricks straight or curved on plan to any radius in half brick thick wall, built in Cement Mortar 1:4.
Rendering in two coats with first coat of 10mm thick in CM 1:6 and second coat of 5mm thick duly mixing water proofing compound in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement . Note: Supply only WPC shall be measured and paid separately.
Supply only Liquid water proofing compound (ISI marked) of approved make.
Rendering 10 mm thick on internal surfaces of other than fair faces of brick work in cement mortar 1:6 finished even and smooth without using extra cement .
5mm thick plaster in CM 1:3 on concrete surfaces of ceilings . by the Engineer-in-Charge.
Preparation of new plastered surfaces (internal walls) and applying two coats of oil bound distemper over a coat of primer including 1 mm thick wall care putty.
Applying two coats of weather shield exterior emulsion paints over a coat of primer including preparation of new external wall surfaces.
In repairs gun metal gate valve of size 32 mm bore conforming to IS: 778 with iron wheel head screwed both ends for iron pipe & fixed.
PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls.
PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls.
PVC (SWR) vent cowl 110 mm bore.
PVC (SWR) vent cowl 75 mm bore.
75 mm bore PVC (SWR) bends any radius .
110 mm bore PVC (SWR) bends any radius .
110mm bore PVC (SWR) branch piece, double (double Y) equal or unequal.
PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement.
In repair three layer PP-R (Polypropylene random copolymer) pipes of outer dia 32 mm bore pipes SDR 7.4 & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.
In repair three layer PP-R (Polypropylene random copolymer) pipes of outer dia 25 mm bore pipes SDR 7.4 & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.
Cutting chases, pinning in, making good to facing were required and pointing in cement mortar 1:3 for concealed water tubing and making good cutting not exceeding 10cm girth.
In repair 15 mm dia bib tap cast copper alloy chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule.
In repair 15 mm dia two way bib cock chromium plated fancy type.
15mm dia pillar tap cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts. Screwed for iron pipe.
15mm dia stop valve cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions.
10 Ltrs (PVC) white, valve less, syphonic action type, dual type flushing cistern, low level with inlet ball valve, float, top push button type and 32 mm dia flush pipe.
PVC connection 15mm size with PTMT nuts of length 600mm.
Concealed type CP with long cup and shank stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
Vitreous china, water closet pedestal pattern (white) 'P' trap (including fixing bolt and seat cover).
Wash hand basin vitreous China white coloured flat back of size (550x400)mm including a pair of bracket and cutting for pinning in ends of brackets but excluding taps, waste, chain and plug.
Chequered vitrified tiles of 10 mm thick of size 300 x 300 mm set, jointed and pointed in neat cement slurry with grey cement pigment in floors over a screed bed of 15 mm thick in cement mortar 1:4.
Exterior wall designer coloured tiles 300 x 450 x 6-7 mm thick as in vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match the surface, including 10mm thick backing coat to receive tiles in CM (1:3) finished even and rough
Stairs (framed) including stringers, trades, landing, balusters, hand rails etc. including cleats, brackets, etc. conforming to Fe-410-W (Gde-E-250) quality-A
2nd class hardwood boarding, 40 mm thick planed one side, with butt joints and fixed with nails
Taking down and refixing of old steel stair
Dismantling cast iron work of any description
Applying acrylic cementitious, elastomeric, two component water proof coating of master builders solutions or equivalent by mixing both the components to a lump free consistency by suitable means and applied on the prepared surface in 2 or 3 coats at an interval of 4 to 8 hours between coats, depending on the atmospheric conditions, applied at a total consumption of 3 Kg/Sqm to achieve a total dry thickness of 1.5 mm and coating shall be continued along the wall and allowed to cure etc. coating shall offer the following performance parameters:- (i) Tensile Strength – 1 MPa as per ASTM D 412 (ii) Elongation – 35% as per ASTM D 412 (iii) Water penetration – No leakage at 5 Bar pressure as per DIN 1048
Taking down carefully existing aluminium /copper conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc and removing materials from site and making good the disturbed surfaces of walls roof and floor etc as per existing specification.
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and fan regulators etc. for reuse at site. (Note : To be measured only when found serviceable in all respects complete for reuse)
Point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing/New concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated for mounting modular switches, sockets, fan regulators etc including testing on completion complete including making good disturbed surface.
All as per Item no 98 here-in-before but for one fan /E Fan point controlled by 1 one way switch and regulator.
All as per Item no 98 above but for one 3 pin switch socket outlet, 5 Amp on independent board.
All as per Item no 98 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
All as per Item no 98 here-in-before but for one 16 Amp 3 & 5 pin switch socket outlet, independent with 4.0 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4.0 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire.
Sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm as in continuous earth wire drawn into and including PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and making good the disturbed surfaces. Note: 2 runs of 4 Sq.mm, 1 runs of 4 Sq.mm & one run of 25mm dia PVC Conduit will be measured as one unit
Sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 6.0 sqmm size and drawing into and including concealed PVC conduit of 25 mm dia with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 6.0 sqmm, single core, as earth continuity wire. (NOTE: 3 runs of 6.0 Sqmm cable and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM)
Modular plate switch flush type single pole one way 6 Amp, 250 volt ,.
Switch modular flush type single pole two way 5 Amp, 230 volt ,.
Modular plate switch flush type single pole one way 16 Amp, 250 volt ,.
Modular socket 6 Amps 5 pin.
Modular step type fan regulator 120 watt two module five steps and back plate.
Modular plate white colour suitable for flush metal boxes for mounting modular switches or sockets etc for 8 modules.
All as per Srl Item No. 110 here-in-above but for 6 modules
All as per Srl Item No. 110 here-in-above but for 3 modules
All as per Srl Item No. 110 here-in-above but for 2 modules
Flush metal box 1/2 module.
All as per Srl Item No. 114 here-in-above but for 6 modules
All as per Srl Item No. 114 here-in-above but for 3 modules
All as per Srl Item No. 114 here-in-above but for 8 modules
Ceiling rose surface bakelite 65 x 30 mm three terminals.
Fixing only ceiling rose surface bakelite three terminals. (Material obtained from item No 97 here in before shall be used)
Sheet metal enclosure for MCCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts
Sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with din rail earth and neutral bar.
MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position.
MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position.
MCB Double Pole of capacity 40 amps, 240 Volts c-series with 10kA breaking capacity .
Single pole and neutral enclosure with two pin earth plug and socket with 01 Nos of MCB DP 20 Amps 'C' series.
Indoor luminaries decorative batten for wall/ceiling mounting box type Extruded aluminium housing ,PC Diffuser, energy efficient saving LED BATTEN LIGHT 20W, 230 V, 50 HZ, slim integrated design easy install including twin twisted copper conductor flexible wire from ceiling rose to connector. (CG Cat Part no. CCS-100-20-65-HL2-DP-NWH or equivalent as approved by GE)
Recess Mounting luminaries LED down lighter of 12 W white in the shape of Square.
Wall security LED light luminaries fitting 1X25 W and including cable for connection from ceiling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut, washer, clamp etc.
Ceiling fan 230 Volts 1200mm sweep, 5 STAR rating, BLDC 32W decorative blades complete incl fan hook made out of 16 mm dia mild steel hook with all accessories.
Exhaust fan metal body of size 300 mm sweep, single phase,230 volts AC with louver shutter /grill and connection complete with cutting of a hole on wall of suitable size.
Taking down solar water heater of capacity 500/200 Ltrs in existing position after disconnecting the water pipe line, water tank and re-assembling the water tank, solar water heater flat collector complete testing and refixing the other position, including all connection, labour cost & transportation for replacing are deemed to be inclusive in the quoted rate. Solar water heater comprising of the following :- (a) Inspection, taking down, opening for dismantling, de-scaling, brushing and thoroughly cleaning the storage tank up to the satisfaction of the Engr-in-Charge. (b) Checking of all stop cock, solar flat plate collector/ tube collector and re-adjust. (c) Re-assembling the solar water tank, solar water tube collector/ flat plate collector, re-install and testing. Note : Parts/ components of solar water heater found unserviceable shall be replaced by the contractor without any extra cost to the deptt. Material and labour charges required for replacement are deemed to be included in the quoted rate.
Earthing complete with 2.5m CI pipe 80 mm dia with flanged ends, centrifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slot up to 2 mtrs length buried directly and preferably vertically in ground with top flanged ended 2 mtrs below ground level welded/ connected with GI strip 32×6mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400 mm dia bore in any strata of soil to lower the CI pipe complete including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab and necessary testing on completion. .
Framed brackets of angle iron, flat iron, made to shape required including welding etc as frame work for water tank, conforming to Fe-410 or Fe-310-O including MS sheet base painting.
Wall or surface hot water pipe 15 mm bore line duly insulated with glass wool and aluminium cladding with all accessories
Wall or surface medium class grade 25 mm bore GI pipe with all fittings laid in trenches
Note : 1. All items in the schedule shall be read in conjunction M&L or S&F as applicable. 2. All items in the schedule shall be completed in all respect as directed by the Engr-in-Charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .