Supply and installation of Fire Check Door and Miscellaneous civil works at SDF Building
2026_WEBEL_1027348_1
WEBEL/ EOT/W/26-27/000044 Dated 04/06/26
Open Tender
CIVIL WORKS
45 days
SDF Building Salt Lake Sec V Kolkata
Please refer to the Tender Document
6 documents required · 6 mandatory
₹500
₹10,400
Yes
10 Jun 2026
10 Jun 2026
30 Jun 2026
10 Jun 2026
29 Jun 2026
10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supplying, fitting & fixing fire resistant door frame conforming to IS:3614, tested and certified as per laboratory approved by Engineerin- charge, of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 120 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with back plate bracket and anchor fastener of approved size and make. Rubber door silencers should be provided on striking jamb.
Supplying, fitting & fixing fire resistant Door leaf of 46 mm thick fully flush double skin glazed fire resistant door shutters with or without vision lite, of 120 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 18 SWG G.I. sheet (zinc coating not
less than 120 gm/ m2) duly filled heat-resistant phenolic resin bonded insulation material (honeycomb craft) and fixing with necessary stainless steel ball bearing hinges of approved make. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturer recommendation with a beeding and screw from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating.
All door and frames shall be finished with polyurethene aliphatic grade paint of approved colour including applying a coat of approved brand fire resistant primer. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation complete as per direction of Engineerin- charge.
2 hour Fire rated door single leaf of size (1200 mm x 2180 mm). | - | - | - | - | Item 01 |
| 2 | At Ground Floor. | - | Each | - | - | - |
| 3 | At 1st Floor. | - | Each | - | - | - |
| 4 | At 2nd Floor. | - | Each | - | - | - |
| 5 | At 3rd Floor. | - | Each | - | - | - |
| 6 | At 4th floor. | - | Each | - | - | - |
| 7 | At 5th floor. | - | Each | - | - | - |
| 8 | Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style, made of heavy duty cast iron/ steel body & latches with SS, BHMA certified & conforming to ANSI A 156.3 for grade-1 (3 hours fire rated) and suitable for surface mounting to wooden/hollow metal/ Al framed door withopening upto 900mm, with maximum operating force 6 kg for unlocking easily & outwardly during emergency, complete in all respect as per direction & satisfaction of Engineer-in-Charge.
For door opening 900. | - | Each | - | - | Item 02 |
| 9 | Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors, of size EN-4 for leaf width upto 950/ 1100mm weighing maximum 60/ 80 kgs, CE certified, marked & conforming to EN 1154-2003 of
approved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge.
For leaf width upto 950mm. | - | Each | - | - | Item 03 |
| 10 | Supplying & application of chemical for post installed rebar connection by using ETA approved for seismic criteria in rebar connection, including drilling hole to the required depth by rotary hammer drill, cleaning with brush & jet of clean air, filling chemical using serrated nozzle to eliminate mixing error & in a voidless manner including charges for all tools & plants. Application to be designed for post - installed rebar as per EC2/TR023 or relevant tested & accepted design guidelines & the design documents to be furnished by the manufacturer. The chemical should have ETA approval for seismic criteria of rebar fixing which should be furnished by manufacturer. The installation & the setting instructions should be strictly followed as per manufacturer's specification as per approved by EIC prior to drilling along with the post - installed rebar embedment design report. The existing concrete member should be scanned using rebar scanner to avoid hitting existing reinforcement in concrete
during drilling. Cost of post installed rebaring application with chemical as specified for 12 mm dia per cm of depth. | - | cm | - | - | Item 04 |