| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹46.4 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹49.6 L+₹3.2 L (6.80%)Rejected-Finance | 2 | Rejected-Finance NOT L-1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
24 Feb 2020, 6:00 pmClosed
CWE AHMEDABAD
CWE AHMEDABAD
SPECIAL REPAIR TO BLDG NO P 06 (SINGLE JCO S ACCDN) AT AHMEDABAD CANTT
2020_MES_319301_1
86811
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA AHMEDABAD
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY AHMEDABAD
₹98,000
Yes
2 Sept 2020
28 Jan 2020
25 Feb 2020
28 Jan 2020
24 Feb 2020
12 Feb 2020
28 Jan 2020 - 31 Jan 2020
Amount
Taking down shutters of any description exc 1 Sqm and n exc 2 sqm each and refixing in same opening complete all as specified and directed.
Taking down chowkats or frame with shutters ( without taking off shutters from the frame) n.exc 1.5 sqm each complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm and n exc 4.0 sqm each complete all as specified and directed.
S&F steel window with side hung shutters including box type hinges with steel handles and steel peg stay complete with glazing bars dove-tailed or welded complete including one coat of shop coat of primer.
Ditto as above item but without glazing bars
S & F mild steel bars conforming to Fe 290 Gde E-165 as in guard bars or similar works including welding etc complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from wooden or metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and directed.
S&F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 sq.m in each pane complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm normal dia of wire and average width of aparture 1.40mm and fixed with tinned tacks or Stainless steel wire stapples complete all as specified and directed.
S/F factory made flyproof mesh panel pvc door shutter 30 mm thick (Style) consisting of frame made out of M.S. frame shall be covered with heat moulded wood grain printed PVC 'C' chanel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, all as per specification & drawing and SS wire gauzed i.e. panel will be of SS wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be screwed to M.S. tubes. The wire gauge shall be stretched to tighten firmly, all as directed by Engr-in-charge.
S&F 2nd class hard wood factory made plain framed panelled door shutters 35mm thick (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both sides. The size of rail and stiles as per IS:1003 (Part I), Klin seasoned and chemically pressure treated.
M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed
M&L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors all as specified and directed by Engr-in-charge.
S&F mild steel rolled sections as in framing for fixing boards in ceiling and the like fixed with angle cleats and connecting plates of grade Fe-410-S complete all as specified and directed.
S&F butt hinges 100mm size medium weight cold rolled mild steel complete all as specified and directed.
S&F for butt hinges 100mm size medium weight stainless steel .
M&L for 150mm long extructed aluminium handle fabricated type complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section 150 mm size complete all as specified and directed.
S&F aluminium alloy anodised sliding door bolt with hasp and stapple ( bolt type) and fixing clips of sheet cast or extruded section with fixing bolts and sliding bolt of extruded section 300mm length & dia not less than 12mm with & including 6 Nos of bolts complete all as specified and directed.
M&L 18-20mm thick Granite (of any type) work (tablee rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) 10mm thick including pointing in white cment (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed.
M&L for Non Skid ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed CM 1:6 all as Specified.
all as per item above but bt in verticle surfaces with 1:4 backing coat.
M & L for machine cut kota stone slab size as in flooring, stair case landing. treads of steps etc, 20-25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified including 10mm thick screed bed or bedding in cement mortar 1:6. all as specified nd directed
Material & labour for machine cut kota stone slab size as in skirting, dado, vertical surfaces etc, 18-22mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including backing coat 15mm thick cement mortar 1:3 complete all as specified.
M&L for Precast RCC (1:2:4) type B1 (using 20mm graded stone aggregrate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for TMT bars 10 mm dia & over cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends & binding with & including mild steel wire (not less than 0.9 mm dia) or securing with clips quality conforming all as specified & as directed
M&L for Mild steel TMT bars 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L, RCC in 1:2:4 type (20 mm graded aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and the like etc all as specified and as directed by Engineer-in-Charge
Demolition of concrete of any description and in any position not otherwise specifically provided for
S&F factory made solid PVC door, cup board shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded both side prelaminated PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & prelaminated PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail, lock rail & bottom rail panelling of prelaminated PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent cement, supply & fixing in the frame at site as per SSR specification & diagram/product drawing shown on ser page No 156 of SSR Part II complete all as specified and directed.
S&F solid PVC door, cup board frame size 50mmx47mm made out of 5mm Prelaminated PVC sheet reinforced with MS square tube all as per specification and as per drawing shown on ser page No 150 of SSR Part II (for item 884) complete all as specified and directed.
Dismantling asbestos cement (corrugated or semi corrugated, etc)sheets in roof covering complete all as specified.
S & F prepainted galvalume aluminium zinc coating GI base corrugated steel sheet 0.60 mm thick of green colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws complete all as specified and directed.(Note : Corrugation colour and shape of sheet shall be approved by GE)
S & F prepainted galvalume aluminium zinc coating GI base corrugated steel sheet 0.60 mm thick of green colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screws complete all as specified and directed.
S&F mild rolled steel straps in joist, angle ,channel as in purlins, rafters, truss, door frame etc conforming to fe410 w all as directed by Engr-in-Charge complete all as specified and directed.
Dismantling and Refixing of mild rolled steel straps in joist, angle ,channel as in purlins, rafters cleats , ceiling frame etc conforming to fe410 w all as directed by Engr-in-Charge.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling timber scantling 40Sqcm and over in section in any position in unframed work as in rafters, purlins etc complete all as specified and directed.
Dismantling timber scantling 40Sqcm and over in section in any position in framed work as in rafters, purlins etc complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Taking down cement or lime plaster of any description from stone or brick walls etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick/ concrete surfaces in CM (1:4) finished even and fair without using extra cement complete all as specified and directed. (Note :- Supply only WPC will be measured & paid separately)
M&L for 10 mm thick rendering on surfaces other than fair faces of brick/concrete surfaces in CM (1:6) and finished even and smooth without using extra cement complete all as specified and directed.
Supply only Integral waterproofing compound.
Demolition of Brick work or stone/boulder masonry, build in cement mortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks built in CM (1:6) straight or curved on plan & exc 6 m mean radius with old size bricks.
M&L for brick work with sub class 'B' bricks built in CM (1:4) straight or curved on plan to any radius in half brick thick walls with old size bricks.
M&L for brick work with sub class 'B' bricks built in CM (1:6) straight or curved on plan & exc 6 m mean radius with except bricks.
M&L expanded metal,(exc 4kg) cut to length, bent to shape required and tying with and including necessary welding, rebitting etc complete to wood/steel/wall all as specified and directed by Engr-in-Charge.
M&L for Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed
M&L for cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate 75mm thick as in plinth protection including necessary form work and finishing surface even and smooth w/o using extra cement including bitumen joints complete all as specified and directed.
Dismantling wall and ceiling boards any thickness including cover fillets complete all as specified and directed.
S&F Tee grid suspension system of size 600 mm x 600 mm type-1 made out of roll framed hot dipped galvanised steel zince coated of not less than 120 gm/Sqm, main runner 0.3 mm thick of section 24 mm x 33 mm crross runner 0.30 mm thick of section 24 mm x 25 mm, wall angle shall be 0.63 mm thick of section 24 mm x 24 mm grid shall be suspended by 4 mm dia adjustable quick fit hanger rod, system exposed portion shall be pre painted polyester coated in off whitee/white in colour complete with material, fixing, jointing etc., with Coloured textured designer ceiling board (Everest) 4mm thick of size 595 x 595 mm fixing with screws/clips complete all as per manufacturers instructions and direction. (Make : METROC or METACIL or any other equivalent as approved by GE)
M&L for preparation of new plastered surfaces on walls and applying two coats of oil bound distemper over 2mm thick wall care putty and a coat of primer all as specifed.
M&L for preparation of newly plasterd wall surfaces and applying two coats of oil bound distemper over one coat of primer over 3mm thick of wall care putty all as specified
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified.
M&L Preparation of old or previously treated steel surfaces of any description not other wise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by EIC.
M&L for complete removal of existing treatment and applying two coat of oil bound distemper over one coat of primer over 3mm thick of wall care putty all as specified.
M&L for complete removal of existing treatment and applying two coats cement based paint on over one coat of primer on on old plastered or unplastered surface on walls all as specified and directed by the Engr-in-Charge
M&L for preparation of New surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying Two coat of synthetic enamel paint, incl one coat of pink Primer complete all as specified and directed.
M&L, Broken stone or boulder Hardcore of guage n exc 63 mm, deposited, spread and levelled in layers not exc 15 cm thick , watered and rammed to a true surface etc all as specified and directed by engineer- in- charge
M&L 75 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in as in sub base all as specified and directed.
M&L for cement concrete type B0 1:2:4 (12.5 mm graded aggregate) 25mm thick as in coping water troughs and the like including weathring, slightly rounded all as specified and directed.
Rough excavation in soft/loose soil not exceeding 1.5 m deep and getting out complete all as specified and directed.
Removing excavated material exc. 500 m but n exc. 1.50 km and depositing where directed from the starting point. complete all as specified and directed.
Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering all as required and directed by Engr-in-charge.
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
Taking down carefully aluminium or copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
Point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete for the following :-
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on indepdendent board.
Point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for one 16 amp socket outlet controlled by one switch on independent board complete.
S&F switch piano flush button single pole one way 6 amp complete.
S&F switch piano flush button single pole one way 16 amp complete.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete.
S&F LED batten (1.2 m) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 100+ lumens per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make : Philips cat ref no. ENDURALED BATTEN " BN 108C LED 20S PSU CDL WH " or equivalent in Wipro or C & S Elect as approved.
S&F LED fixture 8 watt including connection all as per Philips LED LINEA cat ref no. BN 550 WLED 6 - 6500 or eqivalent in Wipro or Havells or GE Lighting as approved.
S&F LED bulkhead fitting 9 watt IP 66 & IK 09 with pressure diecast aluminum housing & polycarbonate diffuser duly prewired for connection with flexible multi stranded copper conductor cable as required all as per Philips cat ref no. WT202W LED6S CW PSU S1 PC or equivalent in Wipro or Bajaj or Havells as approved.
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe nominal dia 80 mm & inner pipe nominal dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth wire 4 mm dia from pit to main MCB DB protected in 15 mm GI pipe light grade, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 1.0 ohm complete.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLSH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour 20 mm dia along with accessories of nominal sizes .
(a) 2x4 sqmm + 1x4 sqmm earth continuity conductor in 20 mm dia conduit..
(b) 2x6 sqmm + 1x6 sqmm earth continuity conductor in 20 mm dia conduit..
S&F factory made epoxy powder coated MCB distribution board VTPN, 415 volts, 12 ways with acrylic door IP-3 protection IK 09 CRCA sheet and fixed flush to wall and suitable universal mounting and including 160Amps copper bus bar, Neutral bar,Standard DIN rail, Earth bar and cable ties for cable management top and bottom removable gland plates,interconnection, earthing connection, blanking plated in unused spaces as required complete. Make:- Legrand cat ref No. 607760 or equivalent in Hager or Schneider as approved.
S&F MCB distribution board SPN, 240 volts, 8 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
(a) Single pole 6 to 16 amp. Make - Legrand DX3 cat ref no. 408587 to 408592 or equivalent in Schneider or Hager as approved.
(b) Double pole 32 amp. Make - Legrand DX3 cat ref no. 408636 or equivalent in Schneider or Hager as approved.
S&F MCCB four pole, 125 amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs etc complete. Make - Legrand cat ref no 420016 or equivalent in Schneider or Hager as approved.
S&F LED 20 Watt streetlight made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LED's with secondary optics and IP 65 protection complete with fixing arrangement and connection as directed as per Bajaj cat ref No. BCLST 20W LED I code 169829 or equivalent in C&S
DMA PROJECTS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .