Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.9 LAccepted-AOC FLAT NO 201 GF KAMAL VIHAR CGHS LTD PLOT NO 5 SECTOR 7 DWARKA NEW DELHI 110075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹1.0 Cr+₹9.4 L (10.0%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹1.0 Cr+₹10.7 L (11.4%)Rejected-Finance 203 VARDHMAN ENTRANCE PLAZA LSC NASEERPUR DWARKA SECTOR 1A PHASE 1 NEW DELHI 110075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹1.1 Cr+₹15.9 L (16.9%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹1.2 Cr+₹27.1 L (28.9%)Rejected-Finance A 102 GOLDEN SAND APARTMENTS GAZIPUR DHAKOLI ZIRAKPUR PB 160104 | ZIRAKPUR | S A S NAGAR | PUNJAB | 160104 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹1.6 Cr
EMD Value
₹1.8 L
Closing Date
25 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE (AF) WAC PALAM
CE (AF) WAC PALAM DELHI CANTT
PROVN OF CENTRAL AIRCONDITIONING FOR DEVELOPMENT OF INFRASTRUCTURE FOR INDUCTION OF MMRCA AT AF STATION AMBALA (TENDER-VII)
2021_MES_431703_1
CEWAC/AMB/T-34/2020-21
Open Tender
Civil Works
Item Rate
210 days
GE (P) (AF) AMBALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (P) (AF) AMBALA
₹1.8 L
8 Jul 2021
19 Mar 2021
27 May 2021
19 Mar 2021
25 May 2021
17 May 2021
19 Mar 2021 - 9 Apr 2021
90 days
Amount
AIR CONDITIONING WORK
WATER-COOLED SCROLL TYPE CHILLER UNIT WITH R407C/134a/410A REFRIGERANT Supply, installation, testing and commissioning of factory designed, pre-fabricated and floor-mounted, water vapour compression, scroll type water-cooled chiller machine complete with semi-hermatic scroll compressors with independent refrigerant circuits, water-cooled S/T type condenser, S/T horizontal flooded type evaporator with carbon steel shell and seamless copper tubes with elastomeric insulation, common base frame, interconnected copper refrigerant piping and wiring, vibration isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly, CFC-free refrigerant gas R407C/134a/R410A all complete as specified and directed. The quoted price shall be inclusive of a unit mounted star-delta starter in accordance with site parameters, Victaulic coupling and system integrator capable of giving industry standard (modbus/bacnet) output to BMS for critical parameters, etc. Mapping shall be required for all critical points displayed on the chiller control panel. The chiller shall be BMS compatible and shall have RS485/RS232 serial communication protocol; the motor shall be suitable for 3- Phase, 415 V ± 10%, 50 Hz AC electric supply; electric panel shall have an IP 54 rating. Necessary civil work viz. foundation for placement of chillers shall be covered in the scope of work. The chiller shall be as per the approved particular
technical specifications and shall meet the following design criteria:- [a] Local ambient temperature: 109°F [b] Chilled water leaving temperature: 44 °F. . [c] Chilled water entering temperature: 54 °F [d] Evaporator fouling factor: 0.0005 °FPS & condenser fouling factor 0.00p1 FPS. [e] IKW/TR: Not exceeding 0.85 [f] Refrigerant (Ozone friendly type): R407C/41OA/134a [g] Minimum COP required 4.7 [h] Flow Rate: chilled water- 2.46 USgpm/TR; condenser water- 4.0 USgpm/TR. (j) Condenser water entering temp - 90 degree F. (k) Condenser water leaving temp - 98.5 degree F. (l) Condenser fouling factor -0.00100 Sqft hr˚ F/Btu. Scroll-type water-cooled chiller suitable for ambient environmental conditions having actual capacity not less than 65 TR
CHILLED WATER CIRCULATION PUMP (2 W +1 S) Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute end succession type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, elastomeric insulation, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete ail as specified and directed. Necessary civil work viz. foundation for placement of pump, mounting of star-delta starter panel and pump accessories shall be covered in the scope of work. Monoblock type centrifugal pump suitable for 10.08 LPS water flow and 12 MWC head along with elastomeric insulation.
FRP RECTANGULER SHAPE INDUCED DRAUGHT COOLING TOWER WITH VFD Supply, installation, testing and commissioning of FRP rectangular shape, vertical, induced draught counter flow cooling tower with uniform water distribution and optimal heat transfer, having tough fiberglass reinforced plastic (FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60 m/s, FRP basin, rigid honeycomb type PVC fill of suitable thickness, SS sprinklers and non-clogging sprinkler pipes, FRP drift eliminator, energy efficient induced draught axial type fans with factory set and dynamically balanced blades pitch, TEFC squirrel cage high efficiency induction motor wiih IP 65 protection, inlet, outlet, drain and over-flow nozzle connections, etc. suitable for 3- Phase, 415 ± 10% V, 50 Hz AC electric supply complete all as specified and directed. . Necessary civil work viz. foundation, supporting structure, etc. for placement of cooling tower shall be covered in the scope of work. FRP bottle shape induced draught cooling tower suitable for 80 TRAC Plant capacity or heat flow of 241920 Kcal/hour.
CONDENSER WATER PUMP (2 W + 1 S) Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete ail as specified and directed. Necessary civil work viz. foundation for placement of pump, mounting of stae-delta starter panel and pump accessories shall be covered in the scope of work. Monoblock type centrifugal pump suitable for 16.5 LPS water flow and 14 MWC head.
DOUBLE SKIN AIR HANDLING UNITS WITH 43 mm THICK CFC-FREE PUF INJECTED INSULATION PANEL & 10 MICRON PRE-FILTERS Supply, installation, testing and commissioning of double-skin type horizontal, floor-mounted, top/side discharge air handling units having corrosion resistant extruded aluminum hollow profile with thermal break, 16 gauge galvanized steel channel base frame, 43 mm thick double skin panel with pressure injected CFC & HCFC free PUF having 'k‘ value of 0.02 W/°C/m & density 40 kg/m3 pre-coated, pre- plasticized, galvanized outer and inner skin 0.60 mm thick, air-tight casing using gaskets and self- adhesive tapes, AMCA certified energy efficient fans with double inlet, double width forward or backward curved impellers for high static pressure mounted on aluminum extruded side rail base frame, combination of 6 rows deep chilled water coils with anti-corrosion aluminum fins, combination of 2 rows deep hot water coils with anti-corrosion aluminum fins PVC/naylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, 10 micron pre-filters, inspection windows/doors, mixing box and supply/return/fresh air dampers complete all as specified and directed. The AHU shall comprise of the following: [a] Suitable DIDW fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s. NOTE:- Minimum static head 750 mm WC. [b] 4 Pole, TEFC, high efficiency, squirrel cage induction motor having BHP rating 20% higher than the peak capacity, suitable for 415 V ±10%, 50 Hz, 3-Phase AC power supply [c] V-belt drive assembly with pulleys, belt guard, etc., double canvass connections with zip to discharge duct/plenum, etc.
[d] 50 mm thick, washable HDPE, 90% down 10 micron pre-filters, filters, fixing framework, hinge type access doors, etc. [e] 6 row deep chilled water coil section with copper fins and copper tube tested on 21 kg/cms with SS sandwiched drain tray, etc. [f] 2 row deep heating coil section with copper fins and copper tube tested on 21 kg/cm2 with SS sandwiched drain tray, etc. [g] AHU panel made out of 2.00 mm thick mild steel CRCA sheet, duly powder coated, in compartmentalized construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, fire damper actuator motor, etc. complete with required variable frequency drive (VFD), relays, timers, contactors, PT, push buttons, switches, internal wiring, etc. (h) Necessary GI U-trap for disposal of condensate outside the AHU room. (j) Zipped canvass joint between first duct piece and AHU making necessary bellows when idle. (k) Ultra violet radiation lamps for disinfection of air. Necessary civil work viz foundation for placement of AHU, mounting of variable frequency drive (VFD) panel, construction of openings(s) for fresh/exhaust air etc. shall be covered in the scope of work. 28000 CFM, 75 mm WG static pressure.
PAN-TYPE HUMIDIFIER Supply, installation, testing and commissioning of PAN-type humidifier having SS-304 sheet welded construction with unitized stainless steel reservoir divided into two chambers from inside having 25 mm thick fiberglass insulation cladded with aluminum foil, snap-acting humidistat, support legs for free¬standing or wall hanging, brackets for wall-mounting, factory mounted & wired humidifier control cabinet, steam outlet nozzle, water make-up, drain, over-flow, quick fill connections, immersion heaters made of copper or stainless steel, terminal blocks suitable for field power and control wiring and safety thermostat complete all as specified and directed. PAN-type humidifier suitable for 60 l/h evaporation rate
HOT WATER GENERATOR Supply, installation, testing and commissioning of SS 304 shell type vertical electric hot wafer generator for hot water output at 150° F (65.56° C), tested for 350 psig pressure, having resin insulation bonded with fiber glass wool along with aluminum cladding, thermostat for individual step, digital thermometer for inlet & outlet pipes, pressure gauge with ball valve for inlet & outlet pipes, SCR based step less linear controller, float switch, audio/visual alarm for low water level, audio/visual alarm for high temperature, pressure relief valve, door switch, safety thermostat, etc.. complete all as specified and directed. Hot Water Generator suitable for 160 KW heat output
CENTRIFUGAL MONOBLOCK PUMP FOR HOT WATER GENERATOR Supply, installation, testing and commissioning of centrifugal monoblock pump for pumping hot water from hot water generator to heating coil in AHU with energy efficient motor conforming to IS 12615. The pump shall be suitable for the given duty point. Each pump shall be of 100% capacity. (Out of two pumps, one shall be working and one shall be standby.) The pumps shall be insulated with 25 mm thick dosed cell elastomeric insulation useful upto 220 T with wrapped water-proof fabric cloth all as specified and directed. [i] Water Quantity (discharge): 110 LPM [ii] Static Head: 20 m pii] RPM of motor: 2900 [iv] Impeller: Bronze [v] Shaft: High Tensile Steel [vi] Seal: Mechanical [vii] Motor: Suitable HP, Squirrel Cage SPDF having Class B Insulation [viii] Starter Star/Delta or DOL [ix] Base Frame: MS Fabricated [xj Foundation: RCC / PCC foundation as per OEM recommendation
STAINLESS STEEL EXPANSION TANK FOR CHILLED WATER S & F SS- 304 closed expansion tank of pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825-1969 for 'non-fired pressure vessels' complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge, insulated with 50 mm thick elastomeric insulation and cladded with 26 gauge aluminum sheet complete all as specified and directed. SS-304 closed expansion tank of 300 litres capacity
HDPE MAKE-UP WATER TANK FOR COOLING TOWER S & F multilayered HDPE storage tank made up of 100% virgin material, having 100% UV stabilized white outer layer, threaded lid, extra insert lid for protection against algae formation complete with inter¬connection piping and non-return valve etc, complete all as specified and directed. HDPE make-up water tank of 5000 liter capacity
STAINLESS STEEL EXPANSION TANK FOR HOT WATER S & F SS- 304 closed expansion tank of pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825-1969 for non-fired pressure vessels' complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge, insulated with 50 mm thick elastomeric insulation useful upto 220 F and cladded with 26 gauge aluminum sheet complete all as specified and directed. SS- 304 closed expansion tank of capacity 500 Ltrs
CONDENSER WATER PIPING MS ERW CLASS- C PIPE Supply, installation, testing and commissioning of condenser water piping with MS Class 'C' Sch 40 pipes and all necessary fittings i.e. bends, tees, reducers, flanges, structural support, air-purge valves, drain- valves, etc. complete all as specified and directed.
BUTTERFLY VALVE Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having Cl body & disc, SS AISI304 disc seal, CS clamping ring and SS AISI410 shaft and flange drilling standard end connection with accessories complete all as specified and directed.
NON-RETURN VALVE (NRV) Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS: 5312-2 (1986), suitable to handle dear water having turbidity up to 5000 ppm, having Cl body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc, with accessories complete all as specified and directed size 100 mm NB
POT STRAINER Supply, installation, testing and commissioning of PN1.6 rated POT strainer, tested as per BS 6755 (Part- I), suitable high capacity flow throughout full size inlet/outlet, having Cl body & strainer bonnet, stainless steel perforated filter screen, black rubber body/bonnet gasket, SS- 410 ball valve and flange drilling standard end connection, etc. complete all as specified and directed size 125 mm NB.
Y-STRAINER Supply, installation, testing & commissioning of Y-type strainer with Cl/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection, etc. with accessories complete all as specified and directed size 100 mm NB
BALANCING VALVE Supply, installation, testing and commissioning of manual balancing valve, conforming to BS 7350 complete all as specified and directed. The valve shall meet the following technical criteria: p] Body: Cl 260 (GG 25)/DI [ii] Bonnet: Cl 260 (GG 25)/DI IS 1865 Gr. 450/10 [iii] Hand wheel: Cl 220/WCB / M.S. [iv] Stem: SS 410/431 [v] Lower Disc: SS 410 [vi] Upper Disc: SS410 [vii] Body/Bonnet Gasket: CAF [viii] Body/Bonnet Bolts: A 307 Gr. B [x] Gland Packing: Graphited Asbestos
FLOW SWITCH Supply, installation, testing and commissioning of paddle type water flow switch, having operating pressure 1000 kPa, withstand pressure 91750 kPa, insulation resistance over 100 Q, withstand voltage 1500 V AC for 1 minute, contact point life of 1000 k cycles and bellows life 500 k cycles complete with control wiring and accessories, etc, complete all as specified and directed, 100 mm NB
CHILLED WATER PIPING MS ERW CLASS- C PIPE WITH INSULATION Supplying, laying/fixing, testing and commissioning of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with FM approved closed-cell elastomeric foam material of appropriate thickness covered with 230 micron thick double layer laminate of aluminium, coated with a special UV protection and PVC backing, having service temperature range 0 to110 °C, thermal conductivity £ 0.039 W/mK at 40 °C and class 0 fire performance, conforming to BS 476 (Part- 7): 1997, as per specifications and as required. NOTE: The pipes of sizes 150 mm NB & below shall be M.S. ‘C1 class as per IS 1239 (Part-1): 2004 and pipes size above 150 mm NB shall be welded black steel pipe heavy class as per IS: 3589:2001, from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm NB and from minimum 7 mm thick MS sheet for pipes of 400 mm NB and above.
Y-STRAINER Supply, installation, testing & commissioning of Y-type strainer with Cl/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories complete all as specified and directed.
BUTTERFLY VALVE Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having Cl body & disc, SS AISI304 disc seal, CS clamping ring and SS AISI410 shaft and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories complete all as specified and directed.
NON-RETURN VALVE (NRV) Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS: 5312-2 (1986), suitable to handle dear water having turbidity up to 5000 ppm, having Cl body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. with elastomeric thermal insulation of suitable thickness and accessories complete all as specified and directed. 80 mm NB
BALANCING VALVE Supply, installation, testing and commissioning of manual balancing valve, conforming to BS 7350 complete all as specified and directed. The valve shall meet the following technical criteria: [i] Body: Cl 260 (GG 25)/DI [ii] Bonnet: Cl 260 (GG 25)/DI IS 1865 Gr. 450/10 [iii] Hand wheel: Cl 220-/ WCB / M.S. [iv] Stem: SS 410/431 [v] Lower Disc: SS410 [vi] Upper Disc: SS 410 [vii] Body/Bonnet Gasket: CAF [viii] Body/Bonnet Bolts: A 307 Gr. B [ix] Gland Packing: Graphited Asbestos
3 -WAY TEMPERATURE CONTROL VALVE Supply, installation, testing and commissioning of Cl 3-way mixing valve, suitable for operation up-to 10 bar, with electronically operated actuator for AHUs. Water flow through the valve shall be regulated by rotation of brass slipper between the main and the bypass ports; it shall be possible to manually rotate the brass slipper through 360“ and interchange the main and the common ports, to facilitate installation at site. All internals of the valve shall be rust-proof and the 'O' ring shall be of elastomeric insulation. The valve actuator shall be of electronic type with DC motor, the actuator's angle of rotation shall be 90°, it shall be without any limit switches and shall be overload-proof. It shall have an indicator to indicate the position and push-button to disengage the gear train for manual operation complete all as specified and directed, size 100 mm NB. NOTE FOR ITEM NO 3.00 to 3.40:- All the valves/controls / fittings shall be insulated with minimum 25 mm thick elastormeric insulation cladded with 26 SWG aluminium sheet.
FLOW SWITCH Supply, installation, testing and commissioning of paddle type water flow switch, having operating pressure 1000 kPa, withstand pressure 91750 kPa, insulation resistance over 100 0, withstand voltage 1500 V AC for 1 minute, contact point life of 1000 k cycles and bellows life 500 k cycles complete with control wiring and accessories, etc. complete ail as specified and directed., size 80MM NB
HOT WATER PIPING MS ERW CLASS- C PIPE WITH INSULATION Supply, installation, testing and commissioning of hot water piping with MS Class 'C' Sch 40 pipes and all necessary fittings i.e. bends, tees, reducers, flanges, structural support, air-purge valves, drain-valves, etc. thermally insulated with elastomeric insulation of appropriate thickness wrapped with water-proof cloth, suitable to 120˚F temprature complete all as specified and directed.
BUTTERFLY VALVE Supply, installation, testing and commissioning of PN 1.6 rated double flanged shorts long body type butterfly-valve designed, manufactured and tested as per IS: 13095 (1991)', suitable for isolation and throttling services, having Cl body & disc, SS AISI304 disc seal, CS clamping ring and SS AISI410 shaft and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories complete all as specified and directed.
Y-STRAINER Supply, installation, testing & commissioning of Y-type strainer with Cl/MS body, bolted cover; flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories complete all as specified and directed, size 50 mm NB
DRAIN PIPE M&L for UPVC pipes and fittings, resistant to chemical & electromechanical corrosion, conforming to EN 1452-2, having specific gravity 1.43, shore hardness 70”C to 90° C, tensile strength 500 kg/sq.cm, bending strength 950 kg/sq.cm, modulus of elasticity 3.2 X10 kg/sq.cm and dielectric strength > 40 kV/mm complete with accessories complete all as specified and directed. 32 mm NB
BALLVALVE S & F of CL 150 # rated ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fasteners and lever and screwed/socket weld end connection, etc. with accessories complete all as specified and directed. 32 mm NB. NOTE FOR ITEM NO. 3.70 to 3.80 & 4.00: All the valves/ controls/fittings shall be insulated with minimum 25 mm thick elastomeric insulation cladded with 26 SWG aluminium sheet.
AUTO-AIR-VENT Supply, installation, testing and commissioning of automatic air-vent valve with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide cap etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115° C respectively, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and directed. Automatic air-vent having 19 mm end connections
TEMPERATURE GAUGE Supply, installation, testing and commissioning of glycerin filled bimetallic thermometer in compliance to EN13190, having standard range 0° C to 60° C up to 400° C, IP 67 protection, bimetal coil sensing element, accuracy class 1 as per EN 13190, stainless steel casing, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 stem and connection, aluminum dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), toughened glass window, neoprene filling plug and gasket complete with accessories, etc. complete all as specified and directed. Temperature gauge of 150 mm dial size for temperature range 0°C to 100° C
PRESSURE GAUGE Supply, installation, testing and commissioning of glycerin filled pressure gauge in compliance to EN837- 1, having standard range 15 to 0 psi and 16 psi to 10000 psi, IP 67 protection, accuracy class ±1.6% of FS, stainless steel casing and TIG argon welded socket to case, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 bourdon, socket, SS dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), polycarbonate glass window, neoprene blow off disc and filling plug, silicon gasket complete with accessories, etc. complete all as specified and directed. Pressure gauge of 100 mm dial size for pressure range 0 psi to 200 psi
AIR DISTRIBUTION GALVANIZED STEEL SHEET DUCTING Supply, installation, testing and commissioning of pre-fabricated, galvanized steel sheet (G.S.S.) square/rectangular ducting for supply/return air, fabricated from galvanized steel sheet, having zinc coating of 160 g/m2 total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. conforming to per IS 655:1963 along with required scaffolding work to install the ducts at site complete all as specified and directed.
24 G (MS angle flanges)
22 G (MS angle flanges)
20 G (MS angle flanges)
FIRE DAMPER Supply, installation, testing and commissioning of fire damper complete with smoke detector/thermister, fusible link etc, and actuator as required for operation. The fire dampers shall be spring activated on melting of fusible link having melting point 67.13° C. The fire damper shall be located In the SA/RA ducts, at all fire rated crossovers (shafts, walls, etc.). The control panel shall be located in such a way that the reset can easily be done. These combination smoke and fire dampers shall be interlocked with the building management system for the fire detection or HVAC and shall trip/close in the event of fire/smoke in the respective, zone. Fire damper shall be tested as per ULL- 555 and certified by CBRI. The fire- damper shall be of at least 120 minutes fire-rating complete all as specified and directed. The fire dampers shall meet the following criteria: [a] Bare fire dampers with 400 mm sleeve [b] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position. [c] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers [d] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommendations of the manufacturer.
Motorized, spring return type, combination fire and smoke damper
Control panel actuator, including electrical spring type actuator, remote indication of the fire damper, smoke/duct detector as required.
THERMAL INSULATION S & F closed cell elastomeric nitrile rubber insulation with aluminum foil laminated on one side, having thermal conductivity not exceeding 0.037 W/mK at mean temperature of 20° C as per EN12667, moisture diffusion resistance factor or ‘µ’ value of minimum 7,000 for base insulation material without the foil as per EN 12086, fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame and also fire performance of V0, HB as per UL 94,1996, density without the foil between 40 to 55 kg/m3. The insulation material shall be FM (Factory Mutual) USA approved and dust & fibre free. The Aluminum foil shall be 60 microns thick and its weight shall be 193 gsm as per EN ISO 2286-2, tensile strength 90 N /15 mm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3 complete all as specified and directed.
19 mm thick nitrile rubber thermal insulation
13 mm thick nitrile rubber thermal insulation
9 mm thick nitrile rubber thermal insulation
SA/RA DIFFUSERS/ GRILLES/LOUVERS Supply, installation, testing & commissioning of removable supply air jet diffusers, return air grilles/louvers of extruded aluminum sections duly powder coated with volume control damper complete all as specified and directed. SA jet diffusers, RA grilles/louvers with volume control damper
ELECTRICAL WORKS AC PLANT ROOM PANEL Supply, installation, commissioning and testing of factory made, CPRI type tested, indoor, cubical compartmental type "HVAC Panel" of suitable size, conforming to IEC 61439-1 &2, IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 3.15 mm thick mild steel CRGA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with, danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. The HVAC Panel shall comprise of the following:
NOTE: [i] The panel shall be completely Ethernet communication ready to communicate with Energy Management System & shall be Web based application in-built. [iii] The Panel shall be with wireless energy sensor on incomer and outgoing feeders for monitoring (V, I,. P, PF, Energy), voltage loss alarm, Unbalance in phases. Same shall be communicated through Ethernet communication gateway to centralised Energy Monitoring System.
Fully automatic star/delta starter, suitable for 5 HP monoblock pump
Fully automatic star/delta starter, suitable for 3 HP monoblock pump
POWER CABLES M & L for ISI marked 1.1 kV grade aluminum conductor, XLPE insulated armored cables, conforming to IS: 7098 (Part 1)-1988 having stranded aluminum compact shaped conductor as per Cl. 2, IS: 8130- 1984, PVC inner sheath, single armoring of galvanized steel strip/wire and PVC Type ST- 2 outer sheath conforming to IS: 5831-1984, including termination complete as specified and directed.
4.0 core 10 mm2 (for pumps)
4.0 core 16 mm2 (for AHU)
3.5 core, 25 mm2 (for PAN-type humidifier)
3.5 core, 70 mm2 (for chillers)
3.5 core, 185 mm2 (for hot water generator)
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 mm X 3 mm copper strip complete all as specified.
M & L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, filled around with alternate layers of charcoal dust and salt and connected to galvanised strip of size 32 mm x 6 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel and protected by galvanized iron pipe light grade 40 mm bore and watering pipe 20mm dia medium grade with funnel and wire mesh as specified and connected all as shown in electrical plate No 3 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1:2:4 type B - 1 in chamber of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep and 80 mm thick precast RCC 1:2:4 type B - 1 using XPM weighing not less than 4Kg/Sqm for cover slab, complete all as specified and directed. Note: The unit rate quoted by tendrer is deemed to be include for necessary excavation, removal of surplus soil, PCC foundation, RCC cover, XPM weighing not less than 4Kg/Sqm, earth lead protection up to 7.5m etc complete.
Excavation in trenches not exc. 1.5 mtr in depth and n.exc 1.5mtr in width for laying of cables or pipes and getting out in soft/loose soil all as specified and directed.
Returning filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removing excavated material in soft/loose soil exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified.
M & L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable in trenches (total punned depth of sand shall be 180 mm after punning down) complete all as specified and directed. Note: punned thickness of sand shall be measured.
M&L for sub class 'B' bricks old size, laid dry flat over the cable (Width wise) after sand cushioning, for cable protection all as specified and directed.
M & L for cable tray made out of GI sheet of appropriate thicness 300 x 50 mm (deep) powder coated . Make: Slattaco/ Becco.
M & L for cable tray made out of GI sheet of appropriate thicness 150 x 50 mm (deep) powder coated . Make: Slattaco/ Becco.
M/S N.K BUILDERS
HVAC Engineering Co
Blue Star Limited
AP BUILDERS
Pneumatic Engineers Pvt. Ltd.
Jyoti Refrigeration
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .