Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.2 LAccepted-Finance NO NO GHEEKANTA ROAD NAGARWADA VADODARA GUJARAT 390001 | VADODARA | GUJARAT | 390001 | 1 | Accepted-Finance ok |
Tender Value
Refer Docs
EMD Value
₹38,430
Closing Date
26 Oct 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
O/o The Executive Engineer E BSNL ED-I Vadodara
2nd floor, E-5 Staff Quarters TE Bldg Subhanpura Compound, TE Subhanpura Vadodara.
Annual Comprehensive Maintenance and attending faults on call basis for 1pt5TR 2TR capacity WAC SAC FCU units installed at various BBNL OLT Major Telephone Exchanges Transmission equipment room under the jurisdiction of ESD I II of Vadodara SSA
2020_BSNL_59067_2
21/EEE/ED-I/BSNL/VDR/2020-21
Open Tender
Electrical Works
Item Rate
720 days
Vadodara
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO(Cash) O/o PGMTD BSNL Vadodara
₹38,430
Yes
27 Oct 2020
12 Oct 2020
27 Oct 2020
12 Oct 2020
26 Oct 2020
12 Oct 2020
12 Oct 2020 - 26 Oct 2020
90 days
Amount
Annual Comprehensive Maintenance of 1.5 / 2 TR Window / Split / HSAC units / Free Cooling Units installed at various GSM BTS Sites / exchanges under including attending fault on Comprehensive basis covering all ites such as incomer MCB, Voltage stabilizer / controller / wiring / compressor / filter etc attached with existing AC unit of following size WAC / Split AC units etc. (i) 1.5TR Window / Split AC Units
(ii) 2TR Window / Split AC Units
Replacing of following faulty parts with brand new spares suitable for 1.5 TR Window AC units i/c testing, commissioning etc i/c credit of non returning of faulty parts as reqd. a) thermostat
b) Running capacitor (36 MFD) metalic
c) Blower Fan motor for window A/C
d) Fan motor capacitor (2.5 Mfd)
e) Condenser Fan blade of Window AC
f) Blower drum for Window A/C
g) Rotary Compressor WAC ( Test Certificate of manufactor will be required)
h) Reciprocating Compressor For WAC ( Test Certificate of manufactor will be required)
i) Capilary tube Suitable for rotory compressor
j) Strainer Dryer filter for 1.5TR Window AC Unit
k) Condenser Coil 1.5 TR WAC
l) Cooling Coil for 1.5 TR WAC
Replacing of following faulty parts with brand new spares suitable for 1.5 / 2.0 TR Split AC units i/c credit of non returning of faulty parts i/c testing, commissioning etc. as reqd. a) Blower motor
b) Blower Drum
c) Condenser motor
d) Conderser fan blade
e) Condenser coil SPAC
f) Rotory Compressor ( Test Certificate of manufactor will be required) i) 1.5 TR
g) 2 pole contactor 25 Amps
h) Terminal box ( connector) 4/6 way
i) Capacitor 45/5 MFD Duel
Water servicing of 1.5 / 2 TR Window AC / split AC unit / HPAC units with complete cleaning i/c cleaning condencer coil with suitable Chemical ( Activity to be done in month as specified in NIT if required)
Blower Servicing & Cleaning of 1.5 / 2 TR Split AC Units / 2 x 1.5 TR High Sensible AC Units of various BTS/TE Buildings at City area and Rural area including taking out Window AC out side ,blowring out all dust from the complete units and put in working condition etc. complete as required. ( Activity to be done in month as specified in NIT if required )
Carrying out leak testing of Window/ Split AC unit with nitrogen gas, brazing the leak points, flushing the system, vaccumizing, making the system leak proof, testing & commissioning by carging required quantity of R22 / R410 refrigerent gas etc. complete as reqd.
Replacement of 50 mm thick 600 mm x 600 mm microvee type washable synthetic filter inside the GI frame having efficiency above 90% down to the particals of 05 microns suitable for FCU installed in BTS shelter
Supplying and fixing of Auto sequential programable mode Micro controller for two Nos. 1.5/2TR WAC/Split A C units with built in cylic timer ( 4Hrs) capable of operating on 230 Volt, 50Hz single phase A C supply having inbuilt features of temperature sensor with settable over temperature alarm and potential free contacts for extension of the alram High and low voltage cut off arrangement, over load tripping, housed in M S box of appropriate size fabricated out of 16 guage M. S. sheet powder coated having power relays for operation on 100% A C current with 20% over load including making intreconnectoions with 3 core PVC insulated PVC sheathed coper conductor wire of 2.5 sqmm cross section with following LED indications etc.complete as required. (BSNL approved make) ( Item shall be got approved from Engineer-in-charge before installation). (a) Power on-Green (b) Timer on- Red (C ) A C-1 on-Green (d) A C-2 on-Green (e) Over voltage Trip- Red (f) Over current Trip- Red (g) Over Temp. Trip- Red Note : Controller must have memory with visual indication for showing total running hour of each AC unit
Replacement of faulty SPN MCB C series 25 Amps in existing DB as reqd.
Site Visit for checking and attending the defects / faults with minor petty material (Costing below Rs 100/-) including attending minor complaints / faults at various BTS / Exchanges, damage of control wiring of Split AC / AC Pkg Units by the rat cutting etc. as below etc. complete as required (For payments for this item, faults must be attended) . a) Within Muncipal Corporation area
b) Outside Muncipal Corporation area i/c rural
Supplying and charging of fresh refrigerant gas R-22 including making nitrogen pressure testing and arresting leakage , vaccumization / dehydrating of entire circuit including pump down the system etc. complete as required.
Supplying and charging of fresh refrigerant gas 410 including making nitrogen pressure testing and arresting leakage , vaccumization / dehydrating of entire circuit including pump down the system etc. complete as required.
Repairing of the faulty control card as required in the 1.5 / 2 TR SAC / HSAC units after removing and refixing including making interconnections, testing and commissioning etc. complete as required.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .