Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹34.9 L+₹32,068 (0.93%)Rejected-Finance MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance BecomeL2 | |
| 3 | L3₹38.8 L+₹4.2 L (12.3%)Rejected-Finance NIL | L3 | Rejected-Finance BecomeL3 | |
| 4 | L4₹41.0 L+₹6.4 L (18.5%)Rejected-Finance | L4 | Rejected-Finance BecomeL4 | |
| 5 | L5₹41.3 L+₹6.8 L (19.6%)Rejected-Finance 622 A STREET NO 3 FIRST FLOOR SHAKTI NAGAR BATHINDA 151001 PUNJAB | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance BecomeL5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 May 2023, 6:00 pmClosed
GE South Tezpur
GE South Tezpur,Mission Charlia
REPAIR/MAINTENANCE OF DG SET WITH AMF PANEL AT ZONE 5 And 1 (A, B, C) ZONE 1, 3 (A AND B), ZONE 2 AND ZONE 4 UNDER GE (S) TEZPUR
2023_MES_592209_1
8748
Open Tender
Civil Works
Item Rate
240 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹90,000
Yes
6 Jul 2023
29 Apr 2023
30 May 2023
29 Apr 2023
27 May 2023
13 May 2023
30 Apr 2023 - 12 May 2023
Amount
Maint and servicing of DG set 320-400 KVA canopy type with AMF Panel (if installed ), through authorize service agency of OEM , including replacement of defective/workout parts with new spares such as filters, gaskets, V belts, Engine Oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vacuum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of POL tank and radiator etc,complete all as specified and directed. Make - Kirloskar/Cummins/greaves/Ashok Leyland / As per OEM Note:- 1. spares required for above maint will be measured and paid separately under relevant items of Schedule. 2. All breakdown calls should be attended.
All as per Item No-1 Above but for DG set of capacity 180-250 KVA
All as per Item No-1 Above but for DG set of capacity 100-160 KVA
All as per Item No-1 Above but for DG set of capacity 40-82.5 KVA
All as per Item No-1 Above but for DG set of capacity 25-35 KVA
S & F in repair Fuel filter for 300-400 KVA DG set, complete all as specified and directed. Make : As per OEM
S & F in repair Fuel filter for 125-250 KVA DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Fuel filter for 25-100 KVA DG set, complete all as specified and directed. Make : As Per OEM.
S & F in repair Lub oil filter for 300-400 KVA DG set, complete all as specified and directed. Make : As Per OEM.
S & F in repair Lub oil filter for 125-250 KVA DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Lub oil filter for 25-100 KVA DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Air cleaner filter ( inner and outer ) for 300-400 KVA DG set, complete all as specified and directed. Make : As Per OEM.
S & F in repair Air cleaner filter (inner and outer ) for 200-250 KVA DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Air cleaner filter (inner and outer ) for 25-100 KVA DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Bypass filter for 300-400 KVA DG set, complete all as specified and directed. Make : As Per OEM.
S & F in repair Bypass filter for 125-250 KVA DG set, complete all as specified and directed. Make :As Per OEM
S & F in repair Bypass filter for 25-100 KVA DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair V belt for 300-400 KVA DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair V belt for 125-250 KVA DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair V belt for 25-100 KVA DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Display control panel (LED Board) for 25 to 100 kva DG set, complete all as specified and directed. Make : As Per OEM.
S & F in repair Display control panel (LED Board) for 125 to 250 kva DG set, complete all as specified and directed. Make : As Per OEM.
S & F in repair Display control panel (LED Board) for 300 to 400 kva DG set, complete all as specified and directed. Make : As Per OEM.
S & F in repair Fuel actuator with O Ring for 25 to 100kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Fuel actuator with O Ring for 125 to 250 kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Fuel actuator with O Ring for 300 to 400 kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Key switch for 25 to 400kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair coolant temperature sensor (coolent control safety) for 25 to 400kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair AMF controller assy for auto/manual operation for 25 to 100 kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair AMF controller assy for auto/manual operation for 125 to 250 kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair AMF controller assy for auto/manual operation for 300 to 400kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Control assy main generator panel any type for 25 to 100 kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Control assy main generator panel any type for 125 to 250 kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Control assy main generator panel any type for 300 to 400 kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Lube oil pressure sensor adaptor (oil control safety ) 25 to 400 kva DG set, complete all as specified and directed. Make : As Per OEM
S & F in repair Stop solenoid switch 12 Volts, complete all as specified and directed. Make As Per OEM
S & F in repair Stop solenoid switch 24 Volts, complete all as specified and directed. Make- As Per OEM
Supply & Fill Coolant for radiators complete all as specified and directed. Make- As Per OEM
S & F in repair Turbo charger for 25-100 capacity DG set ,complete all as specified and directed. Make- As Per OEM
S & F in repair Turbo charger for 125-250 capacity DG set complete all as specified and directed. Make- As Per OEM
S & F in repair Turbo charger for 300-400 capacity DG set complete all as specified and directed. Make- As Per OEM
Supply & Fill engine oil multi grade 15W40 all as specified and directed. (Make ELF Oil/ Castrol /HP or equivalent of OEM make)
S & F in repair Automatic Voltage Regulator fit for 25-100 capacity DG set complete all as specified and directed. Make- As Per OEM
S & F in repair Automatic Voltage Regulator fit for 125-250 capacity DG set complete all as specified and directed. Make- As Per OEM
S & F in repair Automatic Voltage Regulator fit for 300-400 capacity DG set complete all as specified and directed. Make- As Per OEM
Calibration of FIP and fuel injector from the authorized dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set up to and including 100 KVA (Certificate to this effect that calibration and repair is carried out by authorized dealer will be submitted by the contractor),complete all as specified and directed.
Calibration of FIP and fuel injector from the authorized dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set 125-250 KVA (Certificate to this effect that calibration and repair is carried out by authorized dealer will be submitted by the contractor) all as specified and directed.
Calibration of FIP and fuel injector from the authorized dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set 300-400KVA (Certificate to this effect that calibration and repair is carried out by authorized dealer will be submitted by the contractor) all as specified and directed.
Disconnecting the electric connection of Alternator of capacity 25-100 KVA DG set ,taking the accumulator and cleaning the core assembly through air blower, heat varnishing with insulating material complete all as directed.
Disconnecting the electric connection of Alternator of capacity 125-250 KVA DG set ,taking the accumulator and cleaning the core assembly through air blower, heat varnishing with insulating material, complete all as specified and directed.
Disconnecting the electric connection of Alternator of capacity 300-400 KVA DG set ,taking the accumulator and cleaning the core assembly through air blower, heat varnishing with insulating material, complete all as specified and directed.
S & F in repair Lub Oil cooler plate ,complete all as specified and directed. Make- As Per OEM
S & F in repair Lub Oil pressure gauge pipe of required standard size ,complete all as specified and directed. Make- As Per OEM
S & F in repair Oil spray nozzle assembly ,complete all as specified and directed. Make- As Per OEM
S & F in repair Piston assembly of 25 - 400 KVA DG Set complete all as specified and directed. Make- As Per OEM
S & F in repair Main Bearing of various sizes for DG set of different capacity complete all as specified and directed. Make- As Per OEM
S & F in repair Water temp switch complete all as specified and directed. Make- As Per OEM
S & F in repair Lub Oil pump high discharge of required standard size complete all as specified and directed. Make- As Per OEM
S & F in repair of field coil assembly for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
S & F in repair of Eye bolt for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM.
S & F in repair of fan key for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
S & F in repair of fan assembly for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
S & F in repair of fan for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
S & F in repair of Circle for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
S & F in repair of DE Bearing for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
S & F in repair of Brush holder spindle for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
S & F in repair of NDE bearing cap for125/100/75/62.5kva DG set, complete all as specified and directed. Make- As Per OEM
S & F in repair of Slip ring assembly for 25 -400 KVA DG set ,complete all as specified and directed. Make- As Per OEM.
S & F in repair of Excitation (CX) unit for 25-100 KVA DG set, complete all as specified and directed. Make- As Per OEM
S & F in repair of Excitation (CX) unit for 125 - 250 kva DG set, complete all as specified and directed. Make- As Per OEM
S & F in repair of Excitation (CX) unit for 300-400 kva DG set, complete all as specified and directed. Make- As Per OEM.
S&F battery terminal cable , copper conductor multi strand, unsheathed, single core 25sqmm, 1.5 mtr long each for negative and positive terminal fixed/solder with battery terminal clamp and copper lugs each side of cable suitable for 180 AH Battery (Set of 2 nos.) complete all as specified and directed.
Taking down unserviceable battery and supply and fixing 12 volt, 180 AH battery complete all as specified and directed.
Taking down unserviceable battery and supply and fixing 12 volt, 100 AH battery complete all as specified and directed.
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc for 25-160 KVA capacities of DG Set, complete all as specified and directed.
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc for 200-400 KVA capacities of DG Set, complete all as specified and directed.
Taking down the unserviceable radiator for 25-160 KVA from engine, transportation to the workshop dismantling the radiator, repair the tank /storage portion incl necessary welding & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing in to the existing position & on the engine and testing ,complete all as specified and directed.
Taking down the unserviceable radiator for 200-400 KVA from engine, transportation to the workshop dismantling the radiator, repair the tank /storage portion incl necessary welding & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing in to the existing position & on the engine and testing ,complete all as specified and directed.
S & F in repair self starter 78 volt dc complete all as specified, complete all as specified and directed. Make- As Per OEM
S & F in repair self starter 12 volt dc ,complete all as specified and directed. Make- As Per OEM
Repair, transporting, taking down and servicing of self starter 12/24 volt dc at authorized service centre including refixing the same and testing ,complete all as specified and directed.
Maintenance and servicing the AMF panel and replace the unserviceable items and testing and replace unserviceable wiring connection in panel for automatic operation through relay, contactor, timer, sensor etc,complete all as specified and directed.
S & F in repair of Digital multi function meter suitable for AMF panel, complete all as specified and directed. Make- As Per OEM
S & F in repair of indicator lamp (R,Y & B) suitable for AMF panel, complete all as specified and directed.
S & F in repair of three pole power contractor type MNX-250 with Aux contracts 2 Nos 2 NC , suitable for AMF panel, complete all as specified and directed.
S & F in repair of three pole power contractor type MNX-300 with Aux contracts 2 Nos 2 NC , suitable for AMF panel ,complete all as specified and directed.
S & F in repair of three pole power contractor type MNX-550 with Aux contracts 2 Nos 2 NC , suitable for AMF panel, complete all as specified and directed.
S & F in repair of AC Control contactor - M00AC - 15 4A at 415 Volt suitable for AMF panel, complete all as specified and directed.
S & F in repair of DC control contactor M00AC 15 4A at 415 volt suitable for AMF panel, complete all as specified and directed.
S&F Manual change over switch fitted in sheet steel enclosure 400 Amp, 4P 415V, 50 Hz with after disconnecting all electrical connections including dismantling old unserviceable and making necessary electrical connections complete all as specified and as directed. Make : Havells cat code IHCNFO0400 or equivalent make of Legrand/Schneider/L&T/ABB/Indo Asian
All as per item No. 90.00 here-in-before but of capacity 250 amps ,complete all as specified and directed. (Make : Havells cat code IHCNFO0250 or equivalent make of Legrand/Schneider/L&T/ABB/Indo Asian
All as per item No. 45.00 here-in-before but of capacity 100 amps ,complete all as specified and directed. (Make : Havells cat code IHCNFO0100 or equivalent make of Legrand/Schneider/L&T/ABB/Indo Asian
D G Corporation
M/S N S CONSTRUCTION
M/S G.D. Engineering Construction
Truly Technos LLP
Ms N D Enterpise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .