| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC VIKASH NAGAR GAUSHALA RAMGARH CANTT 829122 RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC Bid amount is lowest and reasonable | |
| 2 | L2₹11.7 L+₹1.2 L (11.8%)Rejected-AOC | L2 | Rejected-AOC Bid amount is not lowest and not reasonable | |
| 3 | L3₹11.8 L+₹1.3 L (12.8%)Rejected-AOC VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L3 | Rejected-AOC Bid amount is not lowest and not reasonable | |
| 4 | L4₹12.2 L+₹1.7 L (16.4%)Rejected-AOC | L4 | Rejected-AOC Bid amount is not lowest and not reasonable | |
| 5 | L5₹12.5 L+₹2.1 L (19.6%)Rejected-AOC | L5 | Rejected-AOC Bid amount is not lowest and not reasonable |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
9 May 2023, 6:00 pmClosed
GE RAMGARH
GE RAMGARH CANTT
REPAIR MAINT OF DEEP FREEZER REFRIGERATOR AC WATER COOLERS GEYSERS AT RAMGARH CANTT
2023_MES_578148_3
8300/3155/E8
Open Tender
Civil Works
Item Rate
180 days
GE RAMGARH CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE RAMGARH
₹30,000
Yes
28 Jun 2023
18 Apr 2023
11 May 2023
18 Apr 2023
9 May 2023
25 Apr 2023
Amount
Taking out old burnt compressor and S & F new sealed /rotary compressor suitable for 1.5 ton capacity of window/split type AC unit and connecting up suction and discharging pipe line with gas welding and duly charged with fresh refrigents gas connecting up all electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Make :Voltas/USHA/Shriram/ Blue Star/ Samsung / Hitachi/Vedeocon/LG/Carrier/General/Onida etc as per existing make at site.
Taking out old burnt compressor and S & F new sealed /rotary compressor suitable for 2.0 ton capacity of window/split type AC unit and connecting up suction and discharging pipe line with gas welding and duly charged with fresh refrigents gas connecting up all electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Make :Voltas/USHA/Shriram/ Blue Star/ Samsung / Hitachi/Vedeocon/LG/Carrier/General/Onida etc as per existing make at site.
Material & Labour for replacement of rusted body portions of split type AC/Window type AC unit of 1.5/2.0 Ton capacity with same gauge / size materials like MS sheet, angle iron similar to the existing one by removing existing, foam pad and components and scraping out old paint on complete body, cleaning surface thoroughly, appling two coats of synthetic enamel paint of approved shade over a coat of red oxide primer including preparation of existing surface , fixing of new foam pad of not less than 3mm thick, refixing of all components, installation in original position, connecting up all electrical connections, testing and commissioning all as specified and directed.
S & F for Condenser fan blade set for 1.5/2.0 Ton capacity of any type of ACs, suitable for existing makes and rotation in the casing testing including taking out the defective condenser fan blade all specified and directed. Make : Kirloskar/Crompton/ Jyoti/ABB/KSB /NGF/BCH or equivalent as approved by GE
M&L for Evoporator fan blower motor of suitable capacity duly ISI marked, double inlet, double width centrifugal type suitable for 1.5/2.0 Ton capacity split type AC including taking down the unserviceable damaged Evoporator fan blower motorr complete all as specified and directed.
Supply and fix in repair swing motor for ACs suitable for existing size and capacity of 1.5/2 Ton capacity complete all as specified and directed.
M&L for painting of split type AC and window type AC by applying two coats of approved synthetic enamel paint over a coat of red oxide primer for any capacity of Acs including preparation of old surface by scrapping and removing of old corroded paint complete all as specified and directed by Engineer-in-charge.
M&L for Single pole contactor for 1.5/2.0 ton capacity of split type ACs including taking down of existing contactor complete all as specified and directed.
M&L for replacement of thermal insulation for 1.5/2.0 Ton split type ACs complete all as specified and directed.
M&L for Themal over load relay for 1.5/2.0 Ton capacity of any type of ACs including taking down unserviceable thermal over load relay complete all as specified and directed.
M &L for Running capacitors of 35 mfd to 60 mfd suitable for 1.5/2.0 Ton Capacity split type AC/window type AC including taking down existing unserviceable running capacitors complete all as specified and directed.
M&L for Starting Capacitor of 80/100/120 MFD suitable for 1.5/2.0Ton Capacity split type AC/Window type AC including taking down old unserviceble staring capacitor complete all as specified and directed.
M&L for Fine filter for 1.5/2.0 ton split type AC includig taking down existing fine filter complete all as specified and directed.
M & L in repairs for Drain connection and drain trap for 1.5/2.0 Ton capacity of split type ACs complete all as specified and directed.
S & F in repair wiring kit suitable for 1.5/ 2.0 Ton capacity of split type AC/Window type ACs complete all as specified and directed.
M&L for capillary tube set suitable for 1 5/2.0 ton capacity of split type AC including taking down of existing unserviceable defective capillary tube set all as specified and directed.
M&L for replacement of rusted mild steel stand (size & shape of existing stand) suitable for mounting out door unit of split type AC complete complete all as specified and directed.
M&L for servicing carefully any type of AC of cap 1.5/2.0 TR from site and removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, cleaning, servicing including chemical wash of cooling coil of indoor cooling unit and condenser coil of out door unit and cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas and re assembling the dismantled components and fixing to its original position complete all as specified and directed.
M&L for shifting of Split AC of 1.5/2.0 TR capacity including removing indoor cooling machine, copper piping, drain pipe and thermal sleeve, lifting angle with necessary re fixing arrangement on wall surface, copper piping of suitable gauge for suction and delivery with insulation, including re-surfacing to disturbed surface and testing and commissioning all as specified. (Note: The copper pipe required will be measured against relevent items in this schedule)
S & F in repair sheet metal enclosures Single pole and neutral (SPN), with a two pin earth plug and socket with one single pole MCB 20-32A Amps, complete all as specified and as directed.
M & L for cleaning / flushing out the refrigeration system thoroughly with CTC, leak testing with CO2 / N2 locating and rectifying the leaks by brazing with silver / copper rod, pressure testing, vaccuminising and charging with refrigerant gas and topping up compressor oil, testing and commissioning of split type ACs/window type ACs of 1.5/2.0 Ton capacity complete all as specified and as directed.
M & L for gas charging with refrigerant gas R-22, R-34 & R-410 in new sealed/eixting unit of compressors ACs/Water cooler/Deep freezer/Refrigerator unit of any type and any size including testing, complete all as specified and as directed by Engineer-in-charge.
S & F new temperature sensor probes in the main circuit of split type AC including removal /taking down of existing temperature sensor probes complete all as specified and as specified.
S & F in repair Printed Circuit Board (PCB Board) for any type of AC units suitable for 1.5 TR to 2.0 TR, complete all as specified and as directed by Engineer-in-charge. Make : Voltas/ Videocon /LG/National aircon/Bluestar/Carrier as approved by GE
S & F in repair remote controller unit suitable for split type ACs/widow type AC unit of 1.5/2.0 Ton capacity complete all as specified and as directed. Make : Voltas/Videocon/LG/National aircon/Bluestar/ Carrier as approved by GE
S & F in repair for PVC drain pipe of 15mm/20 mm dia with suitable clamps on walls and ceiling all as specified and as directed.
S & F in repair cooling coil of 1.5/1/2 ton AC units including necessary welding/brazing of copper pipes line, testing of leakage, complete all as specified and as directed by Engineer-in-charge.
S & F in repair cooling motor for walk in cooler, complete all as specified and as directed.
S & F in repair remote sensor for walk in cooler, complete all as specified and as directed..
S & F in repair controller for walk in cooler, complete all as specified and as directed.
S & F in repair capacitor for walk in cooler of capacity 45 mfd complete all as specified and as directed.
M & L for repairing of cooling coil,cooling fan ,out door motor ,out door condenser coil for walk in cooler complete all as specified and as directed. Note:Minor spares required for repairing is deemed to be included in the unit quoted rate.& not any claim entertained on this account at later stage.
S & F new air filter for AC of any size including removal /taking down of existing air filter complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Tenacity/Athelete or equivalent as approved by GE
M & L for PVC cable 4 Sqmm 3 core unsheathed multi stranded copper conductor including taking down of existing cable complete all as specified and as directed by Engineer-in-Charge. Make : Havells/Polycab/Finolex/Plaza/Anchor.
S & F strainer filter for AC including removal /taking down of existing strainer filter complete all as specified and as directed by Engineer-in-Charge. Make : Voltas/LG/Godrej/Bluestar/Kirloskar/Carrier or equivalent as approved by GE.
S & F in repair copper pipe as per existing size/shape including necessary welding/brazing/making threading required length, complete all as specified and as directed by Engineer-in-charge.
S & F in repair air grill for split AC as existing size/shape/design & make, complete all as specified and as directed by Engineer-in-charge. Make : Voltas/Videocon/LG/National aircon/Bluestar/Carrier as approved by GE
Taking down unserviceable water cooler from the site and transporting the same for repair,removing the unserviceable burnt sealed unit (compressor) from the water cooler and S&F factory overhauled compressor duly charged with compressor oil including welding in position and testing on required pressure and transporting the water cooler at site in its original location of capacity 40/80 ltr complete all as specified and as directed by Engineer-in-charge. Make –Usha/Arco/Sidhwal.
S & F in replacement of running capacitor for water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-charge.
S & F in replacement of starting relay 3 pin for water cooler 40/80 ltrs capacity complete all as specified and as directed by Engineer-in-charge. .
Taking down old defective over load protector & S&F new over load protector of suitable capacity/size for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-charge. Make –Renutral/Techno mech.
S & F in repair starting capacitor for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-charge. Make : Asian/Unistar/Arvind.
Taking out old unserviceable internal wiring and rewiring with same guage and size with flexible copper conductor of suitable size with terminal clips etc including screws, washers etc required for fastering with body complete all as specified and as directed by Engineer-in-charge.
Taking down rusted front and back body mild steel sheet cover and S&F new 2mm thick mild steel plate cover of duly painted to match the existing of water cooler complete all as specified and as directed by Engineer-in-charge. .
S & F in replacement of unserviceable float valve with new polythelene ball suitable for 15mm dia GI pipe complete all as specified and as directed by Engineer-in-Charge.
Taking out old unserviceable 15mm dia water tap and S&F new self closing chromium plated push cock of 15mm dia heavy duty complete all as specified and as directed by Engineer-in-Charge.
Taking out old unserviceable fan motor and S&F new fan motor suitable for water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-Charge.
M&L for cleaning of water cooler complete internally and externally including scraping and complete removing of existing treatment, scales and dirt etc.and applying of two coats of synthetic enamel tone paint over a coat red oxide primer all as specified and as directed.
Taking down unserviceable refrigerator of capacity 250 Ltr to 310 ltr from the site and transporting the same to work shop for repair/removing unserviceable burnt sealed unit (compressor) and supply and fix factory overhauled compressor duly changed with compressor oil including welding in position and testing on required pressure and transporting back to its site and fix in original location complete all as specified and directed by Engineer –in-Charge.
All as per item No 49 here in before but 165 ltr to 190 Ltr capacity.
S & F in replacement of freezer door (plastic) complete with tension spring as per original complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of unserviceable tray with new as per original complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of fruit/vegetable tray as per original complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of pgmy lamp (bulb) as per the existing complete all as specified and directed by Engineer -in-Charge..
S & F in replacement of door liver (plastic) as per original complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of door magnetic gasket as per original make for any capacity of Refrigerator complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of unserviceable relay box type for any type and any capacity of refrigerator complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of unserviceable over load protection with new for any type and any capacity of refrigerator complete all as specified and directed by Engineer -in-Charge. Make : Renutral/Shriram.
Opening of regrigator of any capacity for servicing and refixing the same after flushing out and removal blockage, brazing replacement of liquid line filter and recharging the regrigation gas R-22 to obtain the desired cooling complete all as specified and directed by Engineer -in-Charge.
M&L for spray painting of refrigerator with synthetic enamel paint after preparation of old surface of refrigerator capacity 310/286/165 ltr of any make/model complete all as specified and directed by Engineer -in-Charge.
Taking out deep freezer of any capacity from the site for complete servicing of Deep freezer units by electically disconnecting the units and cleaning the compressor , condenser , piping suction/discharge suction, fan motor, cooling coils, cooler body and connected accessries with the help of blower unit , cleaning the same with water and caustic soda for condenser and piping unit , tighten all nuts , bolts, screws etc checking the door bedding , electrical controls of the cooling units rectify where necessary and refixing in its original site and testing comlete all as specified and directed by Engineer-in-charge
S & F new sealed unit compressor for deep freezer as per existing make and size & capacity as approved by GE complete all as specified and as directed by Engineer-in-charge.
S & F running capacitor 10 mfd including taking out capacitor complete all as specified and as directed by Engineer-in-charge.
S & F in repair fan motor for deep freezer complete all as specified and as directed by Engineer-in-Charge.
S & F in repair relay for deep freezer as per sample complete all as specified and as directed by Engineer-in-Charge.
M & L for body patching including denting at certain place of deep freezer and then spray painting with match of existing finishing complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Voltage stabiliser, copper wound of 5 KVA capacity digital display type having I/P Correction Range of 140 - 280 volt complete all as directed. Make –V-Guard,Havells,Bajaj,Usha,Crompton,Khaitan
Disconnecting carefully water and electric connection from storage type water heater of 25/50 Ltr capacity of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by de-scaling with chemical compound including soldering, brazing the inner tank if required, re-assembling the geyser after cleaning & servicing including replacement of flexible cable of size 2.5 sqmm 3 core with copper conductor up to 1.5 mtr long and re-fixing in existing position complete all as specified and directed. Note:- The rate quoted is deemed to include cost of soldering/brazing work and glass wool superior quality if required at site.
S & F in repair heating element including rubber gasket & washer etc. of capacity 1.5 KW suitable for existing make and shape all as specified and directed.
S & F in repair heating element including rubber gasket & washer etc. of capacity 2 KW suitable for existing make and shape all as directed.
S&F Thermostat including rubber/ PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 /35/ 50 ltrs including taking down existing unserviceable thermostat complete all as specified and as directed.
Supply only safety valve for geyser chromium plated brass 15 mm dia all as specified and directed.
M&L for preparation of surface of geyser 25/50Ltrs capacity by scrapping and applying one coat of sythetic enamel paint of approved colour including tinkering and welding if required at site all as specified and directed.
S&F PVC connecting pipe 18" long with brass adopters for hot and cold water and connecting up with complete for 25 /35/ 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe complete all as specified and directed.
S&F bottom covers (set of two halves) duly painted made out of Aluminium /MS sheet of 18 SWG suitable for 25 /35/ 50 ltrs capacity Geysers including taking down existing unserviciable bottom covers complete all as specified and as directed.
S&F base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly complete all as specified and as directed.
M&L for repairs to water heater inner vessel including brazing, welding, testing for a pressure of 3 Kg / Sq.cm., re-assembling of any capacity Geysers complete all as specified and as directed by the Engineer -in Charge.
S &F in replacement inner stainless steel dome of geyser of capacity 25 Ltrs complete as per sample to match original patterns and shape complete all as specified and as directed by the Engineer -in Charge.
S & F in replacement inner stainless steel dome of geyser of capacity 35 Ltrs complete as per sample to match original patterns and shape complete all as specified and as directed by the Engineer -in Charge.
S&F indication lamp for 25/35/50 ltrs capacity Geysers including taking down existing unserviceable indication lamp complete all as specified and as directed.
S & F in repair PVC insulated copper cable of size 2.5 Sqmm 3 crore to any capacity geysers as required length complete all as specified and as directed.
S & F in repair Plug Top 15A, 230 Volt, AC complete all as specified and directed by Engineer-in-Charge.
om suppler
M/S ROHIT CONSTUCTION
M/S tiwari enterprises
ARYA ENTERPRISES
M/s Ray construction
M/S ANJALI ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .