Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.4 LAccepted-AOC ALAKHRAJ BHAWAN NEAR MAMTA MOTORS BHUSA MORE WARD NO 7 SINGRAULI M P 486889 | SINGRAULI | MADHYA PRADESH | 486889 | L-1 | Accepted-AOC Accepted as being L-1 bidder and acceptable rate | |
| 2 | L-2₹12.5 L+₹24,502 (2.00%)Rejected-Finance MINERS BASTI MINERS COLONY WARD NO 04 BIHARI HOTEL R N SINGH COMPLEX BIJURI ANUPPUR MADHYA PRADESH 484440 | ANUPPUR | MADHYA PRADESH | 484440 | L-2 | Rejected-Finance L-1 Bidder Accepted | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically not accepted as per NIT |
| Sl No | Description | Qty | Unit | M/s. SWETA ELECTRICALS L2 | ANNAPURNA CONSTRUCTION COMPANY L1 |
|---|---|---|---|---|---|
| 1.00 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 10.0 metre | 24 | Each | 5,500 ₹1,32,000 Lowest | 5,829 ₹1,39,896 |
| 2.00 | Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required. | 40 | Each | 950 ₹38,000 Lowest | 988 ₹39,520 |
| 3.00 | Supplying and erection of a set of three 11 KV disc insulator for 33KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. | 15 | Set | 2,010 ₹30,150 Lowest | 2,142 ₹32,130 |
| 4.00 | Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. | 25 | Set | 800 ₹20,000 | 633 ₹15,825 Lowest |
| 5.00 | Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required. | 400 | Kg | 190 ₹76,000 Lowest | 202 ₹80,800 |
| 6.00 | Supplying and erection of single piece nonlinear resistor lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. | 9 | Set | 13,000 ₹1,17,000 | 12,962 ₹1,16,658 Lowest |
| 7.00 | Supplying and Erection of 33KV DO Fuse unit on existing two pole structure with insulator and other assessories complete including locking arrangement as per specifications. | 12 | Nos. | 3,500 ₹42,000 | 3,234 ₹38,808 Lowest |
| 8.00 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre Ion0 etc. with charcoal/ coke and salt as required. | 12 | Set | 12,000 ₹1,44,000 | 10,628 ₹1,27,536 Lowest |
| 9.00 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & SDring washer sDaced at 50mm) | 25 | Meter | 1,100 ₹27,500 | 728 ₹18,200 Lowest |
| 10.00 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer SDaced at 50mm) | 175 | Meter | 150 ₹26,250 | 111 ₹19,425 Lowest |
Tender Value
₹13.5 L
EMD Value
₹17,000
Closing Date
18 Oct 2024, 5:00 pmClosed
Staff Officer EnM SECL Hasdeo Area
OFFICE OF THE AREA GENERAL MANAGER, HASDEO AREA PO SOUTH JHAGRAKHAND COLLIERY DISTT MCB (CG) PIN 497448
Shifting of 33KV/3.3KV substation from Kapildhara Colony of Kurja sub area under Hasdeo Area.
2024_SECL_318781_1
AGM/HSD/SO(EnM)/E-Tender/65 dated 08.10.2024
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Hasdeo Area
Please refer Tender documents.
5 documents required · 5 mandatory
₹17,000
16 Oct 2025
8 Oct 2024
19 Oct 2024
8 Oct 2024
18 Oct 2024
8 Oct 2024
8 Oct 2024 - 15 Oct 2024
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 10.0 metre
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying and erection of a set of three 11 KV disc insulator for 33KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.
Supplying and erection of single piece nonlinear resistor lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supplying and Erection of 33KV DO Fuse unit on existing two pole structure with insulator and other assessories complete including locking arrangement as per specifications.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre Ion0 etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & SDring washer sDaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer SDaced at 50mm)
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/steel tubular/ rail pole etc. as required.
Erection of cradle guard as required.
Pocelain AB Switch with complete fittings 33KV
T-clamp for Dog Consuctor
Stay Clamp for "H" Beam
Red Oxide Paint
Aluminium Paint
Concreting of Transformer Foundation (1:3:6)= 15 Cmt.
Concreting of 33KV VCB Foundation (1:3;6)= 7 Cum.
Control Cable (Copper) 8 core 2.5 Sqmm (Unarmored)
Control Cable (Copper) 4 core 2.5 Sqmm (Unarmored)
Control cable (Copper) 2 core 2.5 Sqmm (Unarmored)
MS Nuts and Bolts 16*90mm
MS Nuts and Bolts 16*160mm
MS Nuts and Bolts 16*200mm
70W LED Street Light complete Set
Total impact of GST for the purpose of CTC
M/s. SWETA ELECTRICALS (BID ID -1094769)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .