Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.1 CrAccepted-AOC | ₹97.1 Cr | L1 | Accepted-AOC being lowest and reasonable |
| 2 | L2₹105.4 CrRejected-Finance | ₹105.4 Cr | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹106.9 CrRejected-Finance 421 4TH FLOOR TOWER A 2 SPAZE ITECH PARK SECTOR 49 SOHNA ROAD GURGAON | GURUGRAM | HARYANA | 122001 | ₹106.9 Cr | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹106.9 CrRejected-Finance 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹106.9 Cr | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹107.4 CrRejected-Finance | ₹107.4 Cr | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹98.5 Cr
EMD Value
₹15 L
Closing Date
4 Nov 2023, 6:00 pmClosed
CHIEF ENGINEER NAVY VISAKHAPATNAM
CHIEF ENGINEER NAVY STATION ROAD VISAKHAPATNAM
PROVISION OF DEFICIENT MARRIED ACCOMMODATION 288 DUS FOR SAILORS POs NEAR ASHOKA PARK, VISAKHAPATNAM
2023_MES_607231_2
85425
Open Tender
Civil Works
820 days
VISAKHAPATNAM
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹3,000
Garrison Engineer(Project)(Navy)No 2Visakhapatnam
₹15 L
Yes
9 Nov 2023
17 Oct 2023
6 Nov 2023
17 Oct 2023
4 Nov 2023
30 Oct 2023
Amount
Schedule "A" Part – I to Schedule "A" Part – XXIII: NOTE: Schedule "A" Part – I to Part – XVII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES", as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "SITE CLEARANCE & AREA DEVELOPMENT/ EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "PILE FOUNDATION ", as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL B/R", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "ROADS /HARD STANDING", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "COMPOUND WALL/ FENCING", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "FIRE FIGHTING, FIRE ALARM & DETECTION SYSTEM", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for ""LIGHTENING PROTECTION ", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for "TV & TELEPHONE", as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for "DEMOLITION", as listed in Schedule "A" Part – XV
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL E/M", as listed in Schedule "A" Part – XVI
Lumpsum price worked out by the contractor for "SOLAR WATER HEATING SYSTEM", as listed in Schedule "A" Part – XVII
Schedule "A" Part - XVIII: [Miscellaneous Items] [Pile Foundation, Internal Electrification, Internal water supply, , External Water Supply, External Electrification, Road/Path/ Hard standing, Area Drainage, Fire fighting system , Fire alarm & Detection system, Lifts, Aviation Light, DG Set, Solar Power inverter, lightening protection, Sewage Disposal E/M, Solar water heating system and TV & Telephone ]
PILE FOUNDATION
Boring for bored cast in situ piles 600 mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Boring for bored cast in situ piles 500 mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Boring for bored cast in situ piles 600mm dia in hard rock / fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Boring for bored cast in situ piles 500mm dia in hard rock / fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Carrying out Initial load [Compression] test on 600mm dia piles, complete all as specified and directed.
Carrying out Initial load [Lateral] test on 600mm dia piles, complete all as specified and directed.
Carrying out routine load test [Compression] on 600mm dia piles, complete all as specified and directed.
Carrying out routine load test [Lateral] on 600mm dia piles, complete all as specified and directed.
Carrying out Initial load [Compression] test on 500mm dia piles, complete all as specified and directed.
Carrying out Initial load [Lateral] test on 500mm dia piles, complete all as specified and directed.
Carrying out routine load test [Compression] on 500mm dia piles, complete all as specified and directed.
Carrying out routine load test [Lateral] on 500mm dia piles, complete all as specified and directed.
Carrying out low strain integrity test on 600mm dia piles including analysing the results complete all as specified and directed.
Carrying out low strain integrity test on 500mm dia piles including analysing the results complete all as specified and directed.
Internal Electrification
All as per Serial Item No. 33 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per item No.33 here-in-before but controlled by two two way switch complete all as specefied and directed.
Supply and fixing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed.
Supply and fixing exhaust fan, 250mm sweep, plastic body, heavy duty with louvers, AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
Supply and fixing exhaust fan, 300 mm sweep, metallic body, 900 RPM heavy duty with louvers, AC single phase, 230 volts , connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
S&F energy efficient LED Tube light fitting with tube 5W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
S&F energy efficient LED Tube light fitting with tube 10W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
S&F energy efficient LED Tube light fitting with tube 18/20W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
S&F LED adore lamp for AC 240 Volts, B22 type CDS, five star rated, 10 Watts complete all as specified as directed
S & F energy efficient LED security light fitting with tube 30 watts new generatiion energy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired and connecting up with with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade bracket of 32 mm dia bend to shape for fixing on wall/ pole with suitable MS bracket nuts, bolts etc., complete all as specified and directed.
M & L for sub-main wiring with 2.5 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 2.5 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 20 mm dia PVC conduit complete all as specified and as directed. Note :(i) Two run of 2.5 Sqmm + one run of 2.5 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for sub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 20 mm dia PVC conduit complete all as specified and as directed. Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for sub-main wiring with 6.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 6.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 20 mm dia PVC conduit complete all as specified and as directed. Note :(i) Two run of 6.0 Sqmm + one run of 6.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for sub-main wiring with 10.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 10.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 25 mm dia PVC conduit complete all as specified and as directed. Note :(i) Four run of 10.0 Sqmm + one run of 10.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
S & F MCCB DB, vertical double door, TPN, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of CCB FP 40 Amps, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed.
S & F MCB DB, double door, single pole and neutral, 12 way, sheet steel, phospetised powder painted with 200 amps rated bus bar, 240 Volts, neutral link, IP : 43 protection, flush mounting type, concealed in walls complete all as specified and as directed.
S & F MCB DB, double door, single pole and neutral, 8 way, sheet steel, phospetised powder painted with 200 amps rated bus bar, 240 Volts, neutral link, IP : 43 protection, flush mounting type, concealed in walls complete all as specified and as directed.
S & F MCB DB, double door, single pole and neutral, 4 way, sheet steel, phospetised powder painted with 200 amps rated bus bar, 240 Volts, neutral link, IP : 43 protection, flush mounting type, concealed in walls complete all as specified and as directed.
S & F RCBO double pole, 32 Amps, 230 Volts, 50 Hz, 10 KA, complete all as specified and as directed.
Supply and fix prefabricated meter box made out of 2mm thick CRCA sheet powder coated of approx size 50cmx 60cm to accommodate 4Nos single phase energy meter, front portion of the meter box to be provided with four opening to take reading of energy meter and four slit to be covered/ fixed with glass, necessary sunmica sheet of suuitable size to provided inside the meter box to fix energy meter, with locking arrangements complete all as specified and as directed. Note: Energy meter shall be measured and paid separately.
Supply, install, testing of single phase two wire energy meter BIS 16444 2015 [reaffirmed 2020] haveing current range 10-60 Amps, 240 Volts, accuracy class 1.0 complete all as specified and as directed.
Supply, install, testing of electric water heater [geyser], storage type steel body with copper of inner tank and heating element upto 2 KW, capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc., complete all as specified and as directed.
M & L earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to GI earth lead wire 4.0 mm dia [earth lead] and GI pipe 15 mm, light grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth wire upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relavent item.
Internal Water Supply
S & F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 16 mm inner dia CPVC pipe complete all as specified and as directed.
S & F Angle stop valve, chromium plated, fancy type, screwed down, high pressure screwed and fixed, suitable for 16mm outer dia CPVC pipes with and including chromium plated urinal water drpoer complete all as specified and as directed.
S & F 15 mm health faucet, chromium plated, fancy type with steel flexible complete suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed.
S & F CP mixer for mixing hot and cold water fancy type, chromium plated, screwed down for pipe, with two outlets going (one for bib tap and other for shower) complete all as specified and as directed.
S & F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S & F Angle stop valve, chromium plated, fancy type, screwed down, high pressure screwed and fixed, suitable for 16mm outer dia CPVC pipes with and including chromium plated urinal water drpoer complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S & F 15 mm health faucet, chromium plated, fancy type with steel flexible complete suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S & F CP mixer for mixing hot and cold water fancy type, chromium plated, screwed down for pipe, with two outlets going (one for bib tap and other for shower) complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S & F digital type water meter [electromagnetic type], flanged tye, MS body for smart metering of high accuracy, robust design, IP 67 enclosure, for residentail water supply, fixing to 150 mm dia GI pipe line with necessary nuts, bolts and washers and including connecting FRLS PVC insulated 3 core, PVC sheathed unarmourded copper wire through 20 mm dia GI pipe light grade complete as per site requirement all as specified and as directed.
SEWAGE DISPOSAL [B/R] / AREA DRAINAGE
S&F Precast SFRC Cover extra heavy duty [rectangular] of Grade [EDH-35] conforming to IS 12592-2002, set in cement mortar (1:4) including cover complete all as specified and directed.
External Water Supply/ Fire Fighting/ Sewage disposal E/M
M & L for 150 mm dia ductile iron pipe spigot and socket type centrifugally cast (spun) all as per IS:8329-2000, class K9 with flexible rubber gasket push on type joint having cement mortar lining with portland slag cement as per IS 455 : 1989 bituminous coating as per Annex 'C' of IS 8329, including provision of specials, such as tee's, elbows, bends, reducers, taper pieces complete all as specified and directed.
M & L for 100 mm dia ductile iron pipe spigot and socket type centrifugally cast (spun) all as per IS:8329-2000, class K9 with flexible rubber gasket push on type joint having cement mortar lining with portland slag cement as per IS 455 : 1989 bituminous coating as per Annex 'C' of IS 8329, including provision of specials, such as tee's, elbows, bends, reducers, taper pieces complete all as specified and directed.
M & L for masonry valve chamber of size 750 X 750 X 750 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
Supply and fix flanged end lift type Foot valve 100 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed.
M&L for cutting the existing 150 mm dia GI pipe for additions and alterations including necessarily done in position without taking down and inserting Tee 150 x150x 150 mm for tapping including all fittings and fixtures complete all as specified and as directed.
Supply, install, testing and commissioning of Monoblock pump set with minimum rating as 30 HP, 60 metre head, 1400 LPM with delivary size of 80 mm bore, 4 pole, 415 Volts, 50 Hz, AC 3 phase supply, electric driven, including of air valve at delivary, pressure guage along with cable tray and suitable base and PCC foundation and connecting with coper conductor cable from pumpset to starter/ LT panel complete all as specified and as directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick GI strip [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth strip upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relavent item.
Supply and fix sheet metal enclosure indoor type feeder panel with provision of fixing incoming and outgoing cables with bus bar and cable connection to tinned copper bus bar with insulators suitable for Three Phase and four wire LT AC, 50 Hz, 415 Volts, 200 Amps capacity complete with powder coating, necessary internal electric connection as required and including provision of the following all as specified and as directed.
(a) MCCB 4 Pole, 415 Volts, 16 KA, 50Hz, microprocessor release 100 Amps capactiy 25 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 01 No. (b) MCCB 4 Pole, 415 Volts, 16 KA, 50Hz, microprocessor release 63 Amps capactiy 16 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 03 Nos. (c) MCB TPN 20 Amps, 'C' Curve -03 Nos. (d) Fully Automatic Star Delta 30 HP starter - 02 Nos (e) LED indicating lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases - 01 No [Set of 03]. (f) Multifunctional digital Meter
External Electrification
Supply, install ,testing and commissioning of outdoor type Four way 11 KV, 630 Amps, 21 KA/3 Sec, both sides extensible, Ring Main Unit / Compact switchgear with copper busbar, consisting of two numbers (as incomer) 630 Amps Fixed Manual / Motorised Load Break Switchs & Two numbers Fixed Manual / Motorised SF6 insulated Vacuum Circuit Breakers (as outgoing) in SF6 Gas insulated sealed for life, minimum 2 mm thickness SS 304 stainless steel tank IP 67 degree protection with one number air Insulated metering module along with FRTU, PT, CT's, multifunctional meters, one number manometer shall be provided for each outgoing feeders, one set of CT 100/1A, 2.5 VA, Class1.0 for metering & one set of 100/1A, 2.5 VA, CL 5P 10 Current Transformers shall be provided, one number of Digital Multifunction Meter with RS 485 Port shall be provided for VCB Feeders, one Set of 11 KV/RT3/110/RT3, Class 1.0, 20 KVA PT shall be provided in Metering Module, Vacuum Circuit Breakers shall be with self-powered micro processor based Numerical Over Current and Earth Fault Relay having charged Open/ Closing mechanism, On/Off indicators, Mechanical Operation Counters etc., including in-built battery along with battery charger and maintenance free batteries of capacity not less than 20 AH to give backup upto 05 hours with 10 open/close operations, complete all as specified and as directed. Note :Contractor shall submit drawings/specifications for approval before placement of order.
Supply, install, testing and commissioning of bus trunking system, sandwich type, Aluminium busway (3L+N+PE), with multi layer polyester film class-F insulation, 100% N, 50KA for 1 sec and 12 KV impulse withstand, enclosure as Integral Earth in GI, with IP-55 protection, bus duct shall be made out of min 1.5 mm thick galvanised sheet steel enclosure (C-Ribbed housing in min 1.5 mm thick) with IP-55 and powder coated painted with RAL 7035 or as per OEM design, minimum temp rise : 550 C over ambient of 400 C rated insulation & operative voltage 1000 V of minimum rating 500 Amps with IP55 protection complete for raising mains of building having length G+9 (No of Blocks 4 Nos). Note: (a) Rate inclusive of all bends, seperators, flexible joints, tap off boxes, end feed units, earthing strip/ connections to busbar, angle iron supports etc., complete. (b) Contractor shall submit drawings/specifications for approval before placement of order.
Supply, install ,testing and commissioning of LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc., used are to be made of rust proof material as per IS: 8623 tinned aluminum bus bar with insulators suitable for three phase and four wire, LT AC, 50 Hz, 415 Volts, 2000 Amps capacity complete with powder coating, necessary internal electric connection as required with and including the following:
(a)ACB 4 Pole, 415 V, 50 KA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 1250 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 No. b)MCCB 4 Pole, 415 V, 36 KA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 500 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 03 Nos. c) MCCB 4 Pole, 415 V,36 KA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 320 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 Nos. d) MCCB 4 Pole, 415 V,36 KA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 200 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 02 Nos. e) Intelligent Panel meter to measure voltage, current, frequency, power factor, KWH etc., with all connected CTs of each breakers - 01 No F) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers : 01 No [Set of 03]
Supply, install ,testing and commissioning of LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, the nuts/ bolts etc., used are to be made of rust proof material as per IS: 8623 tinned aluminum bus bar with insulators suitable for three phase and four wire, LT AC, 50 Hz, 415 Volts, 2000 Amps capacity complete with powder coating, necessary internal electric connection as required with and including the following:
(a) ACB 4 Pole, 415 V, 50 KA (ICS=ICU=ICW for 1 Sec) with microprocessor release (EDO type) of capacity 1250 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CT's, meters and cable boxes. - 01 No. b) MCCB 4 Pole, 415 Volts, 36 KA (ICS=ICU=ICW for 1 Sec) with microprocessor release (EDO type) of capacity 500 Amps, with adjustable type overload protection, short circuit protection, with in-built display for 20 fault history current parameters and necessary CT's, meters and cable boxes. - 03 Nos. c) MCCB 4 Pole, 415 Volts, 36 KA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 320 Amps, with adjustable type overload protection, short circuit protection, with in-built display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 No d) MCCB 4 Pole, 415 Volts,36 KA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 160 Amps, with adjustable type overload protection, short circuit protection, with in-built display for 20 fault history current parameters and necessary CT's, meters and cable boxes. - 02 Nos. e) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers - 01 No F) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers : 01 No [Set of 03]
Supply, install ,testing and commissioning of LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc., used are to be made of rust proof material as per IS: 8623 tinned aluminum bus bar with insulators suitable for three phase and four wire, LT AC, 50 Hz, 415 Volts, 500 Amps capacity complete with powder coating, necessary internal electric connection as required with and including the following:
(a) MCCB 4 Pole, 415 Volts, 36 KA (ICS=ICU=ICW for 1 Sec) with microprocessor release (EDO type) of capacity 200 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CT's, meters and cable boxes - 01 No. b) MCCB 4 Pole, 415 Volts, 25 KA (ICS=ICU=ICW for 1 Sec) with microprocessor release (EDO type) of capacity 63 Amps, with adjustable type overload protection, short circuit protection, with in-built display for 20 fault history current parameters and necessary CT's, meters and cable boxes. - 02 Nos. c) MCCB 4 Pole 415 V, 16 KA, 50Hz, microprocessor release 40 Amps capactiy 25KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 05 Nos. d) MCB TPN, 20 Amps, 'C' curve , 415 Volts, 50 Hz - 04 Nos e) MCB SPN, 20 Amps 'C' curve, 230 Volts, 50 Hz - 03 Nos f)Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc., with all connected CT's of each breakers - 01 No g) Timer switch with control relay/contactor - 01 No h) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers : 01 No [Set of 03]
Supply, install, testing and commissioning of LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc., used are to be made of rust proof material as per IS: 8623, tinned aluminum bus bar with insulators suitable for three phase and four wire, LT AC, 50 Hz, 415 Volts, 500 Amps capacity complete with powder coating, necessary internal electric connection as required with and including the following:
(a) MCCB 4 Pole, 415 Volts, 36 KA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 160 Amps, with adjustable type overload protection, short circuit protection, with in-built display for 20 fault history current parameters and necessary CT's, meters and cable boxes. - 01 No. b) MCCB 4 Pole, 415 Volts, 16 KA, 50Hz, microprocessor release 40 Amps, capactiy 25KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 05 Nos. c) MCB TPN, 20 Amps, 'C' curve, 415 Volts, 50 Hz - 05 Nos d) MCB SPN, 20 Amps 'C' curve, 230 Volts, 50 Hz - 03 Nos e) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc., with all connected CTs of each breakers - 01 NO f) Timer switch with control relay/contactor - 01 No g) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers : 01 No [Set of 03]
S & F loop in loop out box [minimum size 200x160x98 mm] of FRP made with IP 65 protection of thermoplatic circuit breaker boxes with metric knockouts for cable entry and exit, combiclimate Cable Glands of IP66/IP67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, 'C' Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands etc all as specified and directed.
S & F PVC insulated Cable PVC sheathed LT 1100 Volts grade with copper conductor of size 3 core 2.5 sqmm multi stranded drawn through rigid PVC conduit of suitable size, with suitable clamps, bolts, nuts etc., complete all as specified and as directed.
Supply, install, testing and commissioning of sheet metal enclosure indoor type feeder panel with provision of fixing incoming and outgoing cables with bus bar and cable connections to tinned copper bus bar with insulators suitable for three phase, four wire, LT AC, 50 Hz, 415 Volts, 200 Amps capacity complete with powder coating, necessary internal electric connection as required with and including the following:
INCOMER [a] MCCB, AC 3 Phase 415 V, 50Hz, 4 pole, 40 Amps capactiy 16 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 01 No. OUTGOING [b] MCB AC, 3 Phase, 415 Volts, 50Hz, TPN 25 Amps, 10KA 'C' curve - 03 Nos [c] MCB AC, 3 Phase 415 Volts, 50Hz, SPN 20 Amps, 10 KA 'C' curve - 01 No [d] Indicating lamp for phase indication with control fuse/MCB - 01 set [Set of 03] [b] Multifunctional panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs - 01 Sets
Taking down old UG cable of size 3.5 Core 10 to 50 Sqmm from trenches or fixing on wall or passing through pipe or in cable ducts 1100 volts, 3.5 core, PVC sheathed armoured, electric power cables complete all as specified and directed. Note: The old serviceable bricks/cable covers retrieved will be deposited to MES storeyard. complete all as specified and directed.
Taking down old UG cable of size 3.5 Core 70 to 120 Sqmm from trenches or fixing on wall or passing through pipe or in cable ducts 1100 volts, 3.5 core, PVC sheathed armoured, electric power cables complete all as specified and directed. Note: The old serviceable bricks/cable covers retrieved will be deposited to MES storeyard. complete all as specified and directed.
M&L for relaying UG cable of size 3.5 Core 10 to 50 Sqmm retrieved above in trenches or fixing on wall or passing through pipe or in cable duct, including testing and commissioning complete all as specified and directed. Note: Earth work, sand cushioning, cable covers shall be measured and paid separately.
M&L for relaying UG cable of size 3.5 Core 70 to 120 Sqmm retrieved above in trenches or fixing on wall or passing through pipe or in cable duct, including testing and commissioning complete all as specified and directed. Note: Earth work, sand cushioning, cable covers shall be measured and paid separately.
Supply and fix cable jointing kit 11 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 / 4 core XLPE armoured indoor / outdoor type aluminium conductor cable of size 10 Sqmm to 50 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit 11 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 / 4 core XLPE armoured indoor / outdoor type aluminium conductor cable of size 70 Sqmm to 120 Sqmm complete all as specified and directed.
FIRE FIGHTING SYSTEM/ FIRE ALARM & DETECTION SYSTEM
Supply and lay PVC insulated, PVC sheathed cable with stranded copper conductor of size 1.5 Sqmm, 2 core, 1100 Volts grade complete all as specified and directed.
Supply and fix LED EXIT light double sided with battery back up up to 2 Hrs of operating Voltage 230 Volts, 50 Hz complete with all as specified and as directed.
LIGHTENING PROTECTION
M&L for Test point terminal box of size 200 x 100 x 100 mm made out of 2 mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15 mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosphorus Bronze of size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws, etc., complete all as specified and directed.
TV & TELEPHONE
Supply and fix factory fabricated GI metal flush boxes suitable for 1-2 modules complete all as specified and directed.
S & F telephone socket [JACK TYPE] RJ 11 with cover plate complete with all accessories complete all as specified and directed.
S & F TV co-axial socket 1 module complete with all accessories complete all as specified and directed.
S & F internet socket [JACK TYPE] RJ 45 with cover plate complete with all accessories complete all as specified and directed.
Supply & Fixing PVC insulated telephone cable one pair on existing PVC conduit concealed in wall complete all as specified and directed. Note: PVC conduit shall be measured and paid seaparately.
Supply & Fixing CATV co-axial cables [electrolytic grade solid annealed copper conductor, jelly field, aluminium foiled and aluminium wire braided] on existing PVC conduit concealed in wall complete all as specified and directed. Note: [a] PVC conduit shall be measured and paid seaparately. [b] Contractor shall take necessary drawing before commencement.
[SEWAGE DISPOSAL E/M]
Supply, installation, testing and commissioning of non-clogging vertical submersible pump of 3 HP capacity electric driven with chrome steel impeller of minimum flow 250 LPM, head 40 m inside raw sewage tank with float switch, lifting arrangement cabling, installation complete along with the basic requirement of motor protection, including installation with guide rail and lifting chain, testing complete all as specified and as directed
M&L PVC insulated, FR PVC Round Sheathed, copper conductor cable of size 3 core 6 Sq.mm (flexible) industrial cable, 1100 Volts, conforming to IS 694 for submersible pump complete all as specified and as directed
Supply and fix sheet metal enclosure indoor type feeder panel with provision of fixing incoming and outgoing cables with bus bar and cable connection to tinned copper bus bar with insulators suitable for Three Phase, four wire, LT AC, 50 Hz, 415 Volts, 200 Amps capacity complete with powder coating, necessary internal electric connection as required and including the following all as specified and as directed.
INCOMER [a] MCB TPN, 20 Amps, 'C' curve, 10 KA - 01 No [b] MCB TPN, 10 Amps, 'C' curve - 04 Nos [c] DOL Starter 03 HP - 03 Nos [d] LED indicating lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases - 01 No [Set of 03] [e] Multifunctional digital Meter - 01 No
Supply, installation, testing and commissioning of ultra sonic level sensor Rust proof, maintainance free suitable for up to 6 metre water level depth of OHTs, UG Sump, with dead band of less than 06 meter, IP 67 protection, accuracy of 0.25% of F.S, 4-20 mA current output, No of wires: 4 wire, Beam angle : less than 7.5 degree, capable for working in ambient temperature of zero degree centigarde to 75 degree centigarde, non-condensing at 25 degree centigrade and humidity upto 95% with response time of less than 1 sec with 230V AC to 24 V DC, 50 Hz variation compensation, verticle type mounting on top of OHTs/Sump, Suitable for measuring water/ waste water in sump/ OHT with all connections and fixing including clamp, nut-bolt etc., complete all as specified and as directed. Note :This item include all accesories required for the correct operation of sensor.
Supply, install, testing, commissioning and calibration CE and UL approved manufacturer's, smart energy meter with memory / real time clock having CI 0.5 accuracy & Modulus /RTU cummunication over RS 485 and 1 serial port integrated with RTU as per specs mentioned in technical bid documents complete all as specified as directed.
Supply, install testing & commisioning of indoor type PLC (Programmable Logic controller) / RTU (Remote terminal unit) based Automation, protection Panel for STP with feature of Dual mode communication and wireless Radio frequency based communication (The module should be programmed to automatically toggle between the two commication mode based on the actual signal strength available ) suitable for control and monitoring of upto 4 Nos pumps with electrical parameters, 01 No Energy meter, 01 No electromagnetic flow meter with totalizer & 1 No ultrasonic level sensor, panel shall be 500 x 800 x 300 mm front opening type as per MES enclosure guidelines as per given specification:-
(i) The panel should be capable of performing following functions as specified and as directed:- (a) Time & level based operation of lift well, (b) online monitoring of electromagnetic flow meter parameters & energy consumption pumps in desired format. (c) Automatic Operation of motor Actuated Butterfly valves/DO sensors/ compressors, etc., (if required) (d) Automatic duty cycle based operations of pumps (e) Auto Change over in case of pumps failure (f) Single phasing prevention, phase sequence corrector, voltage unbalancing protection (g) Manual mode operation (all connected sub systems & operations in Sewage treatment plant) from the PLC/RTU based Control panel. (ii) The panel shall have 01 No PLC/RTU with following specifications:- (a) Discrete input logic (b) Should have suitable No. of Discrete Input and Discrete Output :- Relay/Transistor (c) Protocol supported : isolated serial/ TCP link : Modbus master/Slave and DNP 3.0 (d) Standard supported :- ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.1 No 213, EN/IEC 61131-2:2007 (e) Web Services :- Integrated Web server (f) 02 Nos isolated RS 485 communication port, 1 Nos. Ethernet communication port with 10BASE-T/100BASE-TX (g) Number of slave :-64 Modbus TCP, & adequate DNP -3 master slaves. (h) PLC/RTU shall be certified by NABL for electromagnetic compatibility and radio disturbance standrads as per CISPR22, IEC 61000-4-2:2008, IEC61000-4-3:2010, capable of sending data to multiple route and on precise location.
(c) Communication protocol - Modbus PLC/RTU to TCP support, Modbus master mode or inbuilt in RTU (Remote terminal unit) (d) Routing - DHCP, static routing, port forwding, traffic routing, static/dynamic DNS, DNS proxy. (e) Operating voltage Range - 24V DC, +/-5% (f) Dual SIM (one standby) via two SIM.
Complete 5 years SIM Data Cost - in RTUs for transmitting data to remote station in dual mode complete all as specified and directed. Note For item Nos 104 to 108: Any other product/ service that is needed to complete the automation work at liftwell functional shall be considered part of scope of work. OEM/contactor will not get any extra price for additonal items for making the SCADA hardware/software operational and functional for the tender duration
(a) Fire man switch (b) Automatic rescue divide (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funning the lift with full load. c) Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. d) Four sleek circular LED light fitting in false ceiling . e) One Sleek circular PVC heavy duty fan in false ceiling. Make for(c) & (d) : Philips / Bajaj / Havells / Crompton Greaves. f) Aluminum chequered plate (3 mm thick) as flooring joint in chequered plate should not more than one and top covering with granite flooring complete. g) Non stop button / independent operation. h) Over load warning indicator both audio and visual type with tripping system having relays etc., (overload protecting / tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be conforming to IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish.
l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. m) Mirror of 4 mm thickness of suitable size as specified. n) Specification plate with complete details . o) Continuous earthling for machine and equipments, 02 Nos of GI plate earthing per lift as shown in electrode plate No.2 of SSR Part-I p) Steel wire rope of adequate size as per relevant IS and as per manufacturer specifications. q) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breaks, control panel, locks, governor, car operational panel, power, control and trailing cables complete. r) Full length display indicator panel. s) Main drives and control shall be of latest, high effective and low power consumption. t) Suitable phase reversal relay shall be provided on the controller to protect lift/ equipment against phase reversal, phase failure and low voltage. u) Stainless steel front opening type landing door & car door with small opening for vision of size 200 mm x 800 mm with toughened glass not less than 8mm thick. Make of Toughened Glass : Safe / Saint Goblin Glass / Modiguard float glass / kesar / Aashi Indian / Atul Tuf / Hindustan pilkington glass works / Trivenin float glass. v) Three-way Intercom connectivity i.e., Ground floor, security post, car cabin and machine room. w) Brail push button to be provided in the lift car.
All as per Serial Item No.109 here-in-before but lift suitable for 13 passengers (884 Kgs)
Aviation Light
Supply and fix aviation obstruction light LED type filament-less bulb with 10 Watt bulb including standard fixing arrangements complete all as specified and as directed
S & F PVC insulated armoured Cable PVC sheathed LT 1100 Volts grade with copper conductor of size 3 core 2.5 sqmm multi stranded with suitable clamps,spacers, bolts, nuts etc., complete all as specified and as directed.
Supply and fix time switches 250 Volts single Phase of 20 Amp rating with contactor fitted inside steel enclosure complete energy saving programmable aviation control switch suitable to operate on single phase AC voltage 160-260 Volts, 50 Hz, housed in a sheet metal enclosure, powder coated, confirming to IP 54 of IS :12063/1987(1999), having programming features of default (company programmed) / define (user programme) to switch on & off the aviation light load for whole the year with 24 programme spreads over year, in-built real time clock with battery backup up to 5 years, 2x20 character LCD display for setting, in-built by-passing switch when required manually controls, in-built a photo sensor circuit option for on the street light when ambient light level falls 40 lux, and off when goes 80 lux with by-passing switch arrangement, entire system shall be protected for over voltage (260 V), under voltage (160 V), over load, voltage spikes & surges and completed with suitable MCB, heavy contactor & duly wired upto input/output terminals complete all as specified and as directed.
DG SET
(A) Alternator :- Standard design alternator rated at 125 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 phase, 4 wire, 415 Volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof, IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated Voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be in a position to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722 i) Insualation class - 'H‘ ii) Temparature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The Voltage is kept constant with +/- 1%, manual Voltage adjustment within +/- 5% v) Frequency regulation +/- 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details, water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under i)Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe light grade upto & outside and 1 Metre away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete within the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows
iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System : Lubricating oil filter Lubricating oil pump vi) Air Intake System : Air intake Manifold Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan
Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice iginiton key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battery Volt display. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms xvi) MS pipe line to and from the fuel tank to the DG Set
C) AMF Panel :- Factory made inbuilt type control cubical type made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 Volts, 3 Phase, 4 wire, AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 125 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating Voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc., g) Annuciation with indication lamps for : (i) Low lub oil pressure. (ii) High Water Temparature. (iii) Engine over speed. (iv) Battery low Voltage Controls :- a) Load on Indication b) Load off indication c) Engine start push button d) Engine stop push button e) Fault accept / reset push button
All as per Serial Item No.114 here-in-before but of capacity 100 KVA
SOLAR POWER INVERTER
Supply, install, testing and commissioning of solar panel powered inverter (sine wave) with battery back up for 08 hours capacity 03 KW (Single phase 230 Volts, 50 Hz, AC supply) complete (off grid type) with and inclusive of all electrical and mechanical accessories & stand for inverter and batteries complete all as specified and as directed. Note: [i] Solar panel of Specification 320 Wp (Minimum) polycrystaline type to be provided. [ii] Inverter and battery back up shall be placed near the staircase 3. [iii] Tubular battery of 12 Volts, 150 AH of sufficient quantity to be provided and rate quoted shall be deemed included in the cost of batteries. [iv] Manual changeover switch 20 Amps single phase, 240 Volts to be provided near inverter for switching on to normal electric supply, incase solar system fails. Cost of the same deemed to be included in the rate quoted. [v] Solar inverter supply will feed to light fittings of parking area, staircase lights, building security lights in ground floor and passage lights, staircase lights of each floor of building. [vi] Before commencement of work contractor shall submit complete wiring diagram for approval.
SOLAR WATER HEATING SYSTEM
Supply and fix pressure release valve for pipe of ize 50 mm bore complete all as specified and as directed.
SCHEDULE 'A' PART-XIX PHASE -III OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 109 AND 110 DURING FIRST YEAR OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year during Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XX PHASE -IV OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 109 AND 110 DURING SECOND YEAR OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year during Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XXI PHASE -V OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 109 AND 110 DURING FIRST YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year during Defect liability period complete all as specified and as directed.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 110 of Sch "A" Phase-I during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 109 of Sch "A" Phase-I during 1st year after expiry of defects liability period all as specified and directed
SCHEDULE 'A' PART-XXII PHASE -VI OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 109 AND 110 DURING SECOND YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year during Defect liability period complete all as specified and as directed.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 110 of Sch "A" Phase-I second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 109 of Sch "A" Phase-I second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
SCHEDULE 'A' PART-XXIII PHASE -VII OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 109 AND 110 DURING THIRD YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year during Defect liability period complete all as specified and as directed.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 110 of Sch "A" Phase-I third year after expiry of defects liability period and After completion of second year Comprehensive Maintenance.
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 109 of Sch "A" Phase-I third year after expiry of defects liability period and After completion of second year Comprehensive Maintenance.
Notes for manning and operation of lifts : (i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge. (ii) The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 Hours and Second Shift shall be from 1430 Hours to 2230 Hours. (iii) In case of non function of passenger lift, the Goods Lift installed in the same building shall be operated as directed. (iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 2 to 3 years items under BoQ shall be deemed to be including the same. (v) The unit rate is deemed to include for maintaining log books, record of repair /replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors. (viii) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc.
(ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job. (x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same. (xi) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. "Name of the firm and designation" on front and on the back of the T-shirt along with protective clothing/ gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. (xii) INSURANCE: The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations.
Note for comprehensive maintenance:- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation. (iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engr -in-Charge. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.
DES RAJ AND SONS BUILDERS PVT LTD
Aalaya Engineering Project Private Limited
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED
Mukul Builders Private Limited
RKEC Projects Limited
CHHABINDRA KUMAR PRADHAN
RAGHUSONS INFRA ENGINEERING PVT. LTD
GOPAL TEKNOCON PRIVATE LIMITED
SVS PROJECTS
SOOD ASSOCIATES PVT LTD
Som Projects Pvt Ltd
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid