| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹20.0 L+₹6.0 L (43.0%)Rejected-Finance GOALAPARA MONIRAMPUR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹20.9 L+₹6.9 L (49.3%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹22.0 L+₹8.0 L (57.2%)Rejected-Finance ABANI APARTMENT 1ST FLOOR 6 2 TALBAGAN ROAD WEST PO NONACHANDANPUKUR BARRACKPORE KOLKATA 700 122 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700122 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹24.5 L+₹10.5 L (75.2%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹19.4 L
EMD Value
₹38,800
Closing Date
4 Jan 2022, 6:55 pmClosed
CWE (AF) KALAIKUNDA
CWE (AF) KALAIKUNDA, KALAIKUNDA AIR FIELD POST, DIST - WEST MIDNAPORE, WB-721303
SPECIAL REPAIR AND REPLACEMENT OF OLD VINTAGE TRANSFORMERS, OCBs AND VCBs
2021_MES_493089_1
8261/BKP/04/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AT AF STATION BARRACKPORE
CLASS E, Category b(ii)
2 documents required · 2 mandatory
₹500
GE AF BARRACKPORE
₹38,800
Yes
24 Feb 2022
7 Dec 2021
6 Jan 2022
7 Dec 2021
4 Jan 2022
21 Dec 2021
8 Dec 2021 - 15 Dec 2021
Amount
Disconnecting and taking out existing HT 6.6 KV VCBs of any make from housing and cleaning, rubbing and overhauling the mechanical parts and Servicing of 6.6KV in door VCB, checking of quality of vacuum interrupter, insulation resistances, static contact resistance, Testing ( IR value, Ratio test, Polarity test) and connection verification of 6.6 KV Current transformer( Set of three) by PRIMARY INJECTION KIT ,and Testing and calibration of relay( set of two Over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. complete all as specified and directed.
Supply and Fix Vacuum Interrupter type VG 2EN with TC suitable for 6.6 KV VCB Panel as per existing, complete all as specified and directed.(Make: Schneider)
Supply and Fix Vacuum Interrupter with TC suitable for 6.6 KV VCB Panel as per sample, complete all as specified and directed . (Make: Kirloskar)
Supply and Fix breaker charging motor including Gear assembly 110 volt/ 220 Volt AC suitable for 6.6 KV VCB panel, complete all as specified and directed.
Supply & Fix Multifunction meter square type Digital of size 96 Sqmm of capacity 0 to 15 KV PT Ratio 6.6KV/110 Volt for panel complete all as specified and directed (Make : Conzerv )
Supply install ,testing and commissioning of Micro processor base relay (02 O/C + 01 EF) for 6.6 KV VCB panel , rating 5 Amps, Auxiliary supply 20-110 Volt DC complete all as specified and directed. Make: L&T / Ashida
Supply install ,testing and commissioning of voltage operated auxiliary relay with SR contacts for 6.6 KV VCB panel , coil rating 24V DC with operational time 20-25 ms, complete all as specified and directed.
M & L for Trip and Close switch for 6.6 KV VCB panel 02 Amps/110 volt with locking arrangement complete all as specified and directed . Make: switron /Kee or equivalent)
S & F 6.6 KV panel indicating lamp fitting LED type suitable for 24 volt/30volt DC complete with base complete all as specified and directed
S & F 6.6 KV panel indicating lamp fitting LED type suitable for 110 volt/230volt AC complete with base complete all as specified and directed
S & F limit switch suitable for VCB Panels complete all as specified and directed .
S & F tap changer switch off load type as approved and suitable for transformer 250 KVA as per existing complete all as specified and directed .
S & F tap changer switch off load type as approved and suitable for transformer 315 KVA as per existing complete all as specified and directed .
Disconnecting HT/LT Connections of Transformer, including disconnecting of earthing lead, unscrewing nuts, bolts and washers, testing their un-serviceability (Open and Closed circuit test) with the help of composite unit of Transformer 100 to 350 KVA 6600/433, and isolation transformer of any capacity complete all as specified and as directed .
Opening Top Lid Cover of Transformer 100 to 350 KVA 6600/433 indoor / outdoor, disconnecting all Internal Connections of HT/LT Side for Periodical Maintenance such as Cleaning of Core and Winding by means of Washing by Hosing Down with Clean Dry Oil to removed Dust/Sludge on Core and Coil, Cleaning of Oil Tank to removed Sludge deposited, Replacement of Rusted Gasket Set, Burnt Spindle, Broken/ Unserviceable HT/LT Ceramic Bushing, Broken Arc Horn, Surge Arrestor, Replacement of Silica Gel, etc. complete all as specified and as directed .
Taking down carefully defective transformer of 100 to 350 KVA 6600/433 indoor / outdoor and from foundation base including draining out old transformer oil complete carefully and keeping the same in a cleaned container in safe custody for reuse after repair works of transformer and transportation from site to contractors workshop and back to site after repair, connecting HT as well as LT side to existing system, testing and commisioning complete all as specified and as directed .
M&L for open the top cover of transformer of capacity 100 KVA to 315 KVA, after disconnecting HT/LT connection, drain out of transformer oil and preserve it in container, replacement of all gasket for prevention of leaking, replacement of broken HT/LT bushes complete as per existing size all as directed, refixing all connection and testing on load complete all as specified and as directed . NOTE : FOR ITEM No. 17 TO 18 (a) Cost of Transformer Oil for Cleaning by Hosing down shall deem to be included in the QUOTED UNIT RATE. (b) Gasket set, LT/HT side ceramic bushing, spindle for HT/LT side and horn surge arrester etc. for replacement shall be measured and paid under relevant item. (c)Transformer Oil to be re-used should be dehydrated/ filtered upto required value under respective items. The rate quoted by the contractor for this item shall deemed to be included for dehydration /filteration of old oil.
M&L for rewinding of LT copper coil for off sizes transformer after removing unserviceable Insulating Materials, Re-insulation and Re-winding as per existing Size of Core of Transformer including Heating, Varnishing, etc., complete all as specified and as directed.
M&L for rewinding of HT coil for off sizes transformer using Proper Size new Copper Wire and HV Insulating Materials suitable for Working Voltage 11 KV complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix Ceramic Bushing and Gasket on HT Side of Transformer 100KVA to 350KVA 6600/433 complete all as specified and as directed. (MAKE : MYSORE POTTERIES/BHELL )
Supply & Fix Ceramic Bushing and Gasket on LT Side of Transformer 100 KVA to 350KVA 6600/433 complete all as specified and as directed. (MAKE : MYSORE POTTERIES/BHELL )
Supply and fix Breather Assembly filled with Silica Gel as Approved complete all as specified and as directed.
Supply & Fix Brass Spindle for Terminal on HT Side Threaded complete with Nut, Washers, etc. of dia as ordered, as Approved and suitable and suitable for Transformer 100 to 350 KVA 11000/6600/433, complete all as specified and as directed.
Supply & Fix Brass Spindle for Terminal on LT Side Threaded complete with Nut, Washers, etc. of dia as ordered, as Approved and suitable and suitable for Transformer 100 KVA to 350KVA 11000/6600/433, complete all as specified and as directed.
S&F Gasket (Cock Sheet) 6 mm thick with Conical Rubber Bush Complete as approved and suitable for Transformer 100KVA to 350 KVA 6600/433 Volt including Taking down/ out unserviceable Gasket, complete all as specified and as directed.
M&L for apply one coat of synthetic enamel paint by spray painting including preparation of body of transformer 100KVA & 350 KVA 11000/6600/433, complete all as specified and as directed.
M&L in repair for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed. Make RAYCHEM/DENSION/3M
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed . Make RAYCHEM/DENSION/3M
M&L of new transformer oil for topping up all as directed complete all as specified and directed by Engr-in-Charge. Make : Power oil.
JADAV CONSTRUCTION
JAIN CONSTRUCTION AND ENGINEERS
Globe Electricals
REMCO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .