Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC 31 A K ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.7 L+₹34,534 (4.72%)Rejected-AOC NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.0 L+₹65,060 (8.88%)Rejected-AOC 2ND FLOOR 2B SORAJ ESTATE ULUBARI K C PATOWARI ROAD ULUABRI KAMRUP ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | L3 | Rejected-AOC L3 | |
| 4 | L4₹8.0 L+₹67,910 (9.27%)Rejected-AOC JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L4 | Rejected-AOC L4 |
| Sl No | Description | Qty | Unit | R.P.ELECTRONICS L4 | Eastern Commerce L2 | RS COOLING APPLIANCES L3 | STANDARD ELECTRONICS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing and Comissioning of ISO certified company made Air cooled High Wall Split type Air Conditioners with latest star rating system as per BEE amemnded up to date complete with Indoor unit (IDU), Outdoor unit (ODU), surface/ concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr. (IDU to ODU), R-32/ R-410/ R-407 Green refrigerant, wireless remote control, suitable for working between 180-260 V with low & high voltage cut-off and 50 Hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ rotary compressor. The system shall be able to deliver 100 % of the rated capacity upto 43 Degree celcius. Minimum 5-Year OEM warranty of both compressor & PCB. Duly accredited lab testing reports as per IS-1391 (Part-2) 2018 with OEM certificate must be submitted to Engineer-in-charge. Complete as per CPWD specification, as per the terms & condition and as directed by Engineer-in-charge | |||||||
| 1.01 | 1.5 TR split type high wall AC machine (rated cooling capacity should not be less than 4500 Kcal/hr or 18000 Btu/hr or 5250 watt) | 1 | No | 36,000 ₹36,000 Lowest | 36,900 ₹36,900 | 50,000 ₹50,000 | 40,000 ₹40,000 |
| 1.02 | 2.0 TR split type high wall AC machine (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 Btu/hr or 7000 watt) | 7 | No | 56,000 ₹3,92,000 | 51,900 ₹3,63,300 Lowest | 55,500 ₹3,88,500 | 52,000 ₹3,64,000 |
| 2.00Supply, Installation, Testing and Comissioning of ISO certified company made Air cooled Floor Standing Tower type Air Conditioners complete with Indoor unit (IDU), Outdoor unit (ODU), surface/ concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr. (IDU to ODU), Copper power cable upto 3.5 Mtr. (IDU to ODU), R-32/ R-410/ R-407 Green refrigerant, wireless remote control, suitable for working between 180-260 V with low & high voltage cut-off and 50 Hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ rotary compressor with minimum 5 Year OEM warranty for both compressor & PCB. Duly accredited lab testing reports as per IS-1391 with OEM certificate must be submitted to Engineer-in-charge. Piping connection should be 9.5 mm &15.9 mm as per ISO manufacturing standards, complete as per CPWD specification, as per the terms & condition and as directed by Engineer-in-charge. | |||||||
| 2.01 | 4.0 TR (rated cooling capacity should not be less than 12000 Kcal/hr or 48000 Bthu/ hr or 14000 Watt) | 2 | No. | 1,30,000 ₹2,60,000 | 1,34,567 ₹2,69,134 | 1,32,000 ₹2,64,000 | 1,20,000 ₹2,40,000 Lowest |
| 3.00 | Standard installation, testing and commissioning of 1.5/ 2.0 TR split and window type machine including hole cutting, finishing etc as per direction of the Engineer-in-charge. | 8 | No. | 4,000 ₹32,000 | 1,600 ₹12,800 Lowest | 2,500 ₹20,000 | 3,000 ₹24,000 |
| 4.00 | Standard installation, testing and commissioning of 4.0 TR high wall and ceiling mounting split type machine including hole cutting, finishing etc as per direction of the Engineer-in-charge. | 2 | Mtr. | 10,000 ₹20,000 | 5,000 ₹10,000 | 5 ₹10 Lowest | 5,000 ₹10,000 |
| 5.00 | Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. | 10 | No. | 2,000 ₹20,000 | 800 ₹8,000 Lowest | 1,250 ₹12,500 | 1,000 ₹10,000 |
| 6.00 | Supply, installation of additional length of copper pipe beyond 10 ft length of 5/8”, 3/8", 1/2" and 1/4” diameter diameter for suction and liquid line with insulation and necessary wiring between indoor and outdoor units as per direction of the Engineer-in-charge. | 53 | Mtr. | 570 ₹30,210 Lowest | 900 ₹47,700 | 950 ₹50,350 | 600 ₹31,800 |
| 7.00 | Providing hard UPVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. | 100 | Mtr. | 100 ₹10,000 Lowest | 190 ₹19,000 | 120 ₹12,000 | 125 ₹12,500 |
Tender Value
₹8.1 L
EMD Value
₹16,210
Closing Date
25 Apr 2025, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division Agartala
Providing Installation Testing and Commissioning of split type air conditioning system in various rooms Room No 1202 1209 6207 5104 under the Home Department Secretariat Building Agartala
2025_CEPWD_60237_1
115_EE_DNIeT_MECH DIVN_AGT_2024_25
Open Tender
Electrical Works
Works
60 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹16,210
18 Aug 2025
10 Apr 2025
25 Apr 2025
10 Apr 2025
25 Apr 2025
10 Apr 2025
Amount
Supply, Installation, Testing and Comissioning of ISO certified company made Air cooled High Wall Split type Air Conditioners with latest star rating system as per BEE amemnded up to date complete with Indoor unit (IDU), Outdoor unit (ODU), surface/ concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr. (IDU to ODU), R-32/ R-410/ R-407 Green refrigerant, wireless remote control, suitable for working between 180-260 V with low & high voltage cut-off and 50 Hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ rotary compressor. The system shall be able to deliver 100 % of the rated capacity upto 43 Degree celcius. Minimum 5-Year OEM warranty of both compressor & PCB. Duly accredited lab testing reports as per IS-1391 (Part-2) 2018 with OEM certificate must be submitted to Engineer-in-charge. Complete as per CPWD specification, as per the terms & condition and as directed by Engineer-in-charge
1.5 TR split type high wall AC machine (rated cooling capacity should not be less than 4500 Kcal/hr or 18000 Btu/hr or 5250 watt)
2.0 TR split type high wall AC machine (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 Btu/hr or 7000 watt)
Supply, Installation, Testing and Comissioning of ISO certified company made Air cooled Floor Standing Tower type Air Conditioners complete with Indoor unit (IDU), Outdoor unit (ODU), surface/ concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr. (IDU to ODU), Copper power cable upto 3.5 Mtr. (IDU to ODU), R-32/ R-410/ R-407 Green refrigerant, wireless remote control, suitable for working between 180-260 V with low & high voltage cut-off and 50 Hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ rotary compressor with minimum 5 Year OEM warranty for both compressor & PCB. Duly accredited lab testing reports as per IS-1391 with OEM certificate must be submitted to Engineer-in-charge. Piping connection should be 9.5 mm &15.9 mm as per ISO manufacturing standards, complete as per CPWD specification, as per the terms & condition and as directed by Engineer-in-charge.
4.0 TR (rated cooling capacity should not be less than 12000 Kcal/hr or 48000 Bthu/ hr or 14000 Watt)
Standard installation, testing and commissioning of 1.5/ 2.0 TR split and window type machine including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Standard installation, testing and commissioning of 4.0 TR high wall and ceiling mounting split type machine including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe beyond 10 ft length of 5/8”, 3/8", 1/2" and 1/4” diameter diameter for suction and liquid line with insulation and necessary wiring between indoor and outdoor units as per direction of the Engineer-in-charge.
Providing hard UPVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
Eastern Commerce (BID ID -172928)
RS COOLING APPLIANCES (BID ID -173813)
R.P.ELECTRONICS (BID ID -172915)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_61260.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .