| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹26.3 L+₹1.5 L (6.21%)Rejected-Finance 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹26.5 L+₹1.7 L (6.71%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹31.6 L+₹6.8 L (27.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹34.6 L+₹9.8 L (39.6%)Rejected-Finance 2 B KRISHNA NAGAR AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Jun 2025, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
CAMOUFLAGE PAINTING AND PERIODICAL SERVICES TO BPs, BUILDINGS, WATCH TOWERS AND SECURITY WALL IN TECH AREA AT AF STN AMBALA UNDER GE (AF) AMBALA
2025_MES_710867_1
GE AF/AMB-T-11/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹80,000
Yes
22 Jul 2025
28 May 2025
27 Jun 2025
28 May 2025
25 Jun 2025
11 Jun 2025
Amount
M&L for preparation of plastered or unplastered surfaces of walls and applying one coats of distemper oil emulsion on old surfaces upto any height including necessary scaffolding as required, complete all as specified and directed. Note: Cost of necessary scaffolding and security provision of labour shall be deemed to be included in the quoted rate.
M&L for one coat of synthetic enamel paint on old painted steel surfaces as in walls / roof trusses/purlins/rafters/angle iron posts etc complete all as specified and directed.
M&L for complete removal of existing treatment from old decorated plastered surface of wall and applying two coats of distemper oil emulsion complete all as specified and directed.
M&L for one coats of painting as per manufacturer instruction to PCC pavements or concrete surface of Runway / taxi tracks and the like of any shade as approved by Engineer-in-Charge including cleaning all foreign materials, dust etc by water or air blower and scrapers complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old or previously treated surfaces of RCC / Stone / Concrete / brick walls/ Asbestos Cement Sheet or plastered surfaces and applying one coat of exterior acrylic emulsion paint in camouflaging pattern of any shape and any size complete all as specified and directed by Engineer-in-charge, Note: Sample of camouflage pattern to be approved as per the user requirement by GE
M&L for complete removal of old or previously treated surfaces of RCC / Stone / Concrete / brick walls/ Asbestos Cement Sheet or plastered surfaces and applying two coat of exterior acrylic emulsion paint in camouflaging pattern of any shape and any size over a coat of primer complete all as specified and directed by Engineer-in-charge. Note: Sample of camouflage pattern to be approved as per the user requirement by GE
Cleaning of dust Removal fo all loose existing bituminious material manually and with heat torch gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repair all joints and cracks with Highly elastic Bituminous cold applied putty of Tarplasic having penetration after setting upto 8mm. Levelling of surface to give proper slope will be done as per site requirements with Shalipatch or equivalent make of approved by GE cold applied, Bituminous Mortar & Cold Emulsion cum waterproofing Liquid of Shalikote-T-10 or equivalent make of approved by GE, Created SSD condition on surface with water. Prime the surface with Tarfelt LM or equivalent make of approved by GE mixed with portable water in the ration of 1 :1 and apply @400gm per Sqm (As per Surface Conditions). . Apply first coat of Tarfelt LM or equivalent make of approved by GE having elongation 200% conforming to ASTM-C-412 & having crack bridging of 8mm confirming to ASTM-C-836 with tensile strength after 7 days 0.50 mm conforming to ASTM-C-412 with no diluation of water on primed surface while the surface is still tacky with consumption of 700gm per Sqm. . Lay Geotex of 45 GSM/ Fibre mesh simultaneously and paste it properly with overlap of 50mm. . Allow the first coat to dry for 10 to 12 Hrs. . Apply 2nd coat on cured first coat with consumption @ 700gm per Sqm in opposite direction of first coat by Brush or Roller. . Allow it to dry for 10-12 hrs after apply 3rd coat with consumption @ 700gm per Sqm.Ensure final curing time of 36 hrs before allowing/ carrying out any further work. Conduct ponding test after min 7 day applying two coats of U V Resistand Elastomeric Exterior Axcrylic Weather resistant water proof coating of Shalicryl-215 or equivalent make of approved by GE having elongation of 300% after curing of 14 days confirming to ASTM D- 6083-- for U V Protection of Bituminous Elastomeric Acrylic Emulsified Liquid Membranc of Tarfelt LM or equivalent make of approved by GE to give long life and prevent its deterioration from sunlight. Note:- Application of water proofing treatment will be done by Authorised Applicator only.
S&F of 5 mm thick plain colour PVC sheet hollow interlocking wall panelling of width 250 mm for wall panelling inclusive of fixing on wall with screws and solvent alongwith PVC 'U' and 'L' beading at corner and end portion where ever required of matching colour including taking down of existing wall lining, board or insulation board/panelling including cover fillets of any type and thick complete all as specified and as directed. NOTE : - Unit rate quoted against this item shall also includes taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface effected for this area etc complete all as specified and directed.
S&F of 5 mm thick plain colour PVC sheet, solid PVC wall paneling/ lining PVC sheet inclusive of solvent cement and fixing at site with and including 5 mm thick PVC sheet fillets of width 35 mm for wall paneling inclusive of fixing on wall to make PVC frame as per specification and directed including taking down of existing wall lining, board or insulation board including cover fillets of any type and thick complete all as specified and as directed. NOTE : - Unit rate quoted against this item shall also includes taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface effected for this area etc complete all as specified and directed.
S&F semi perforated false ceiling 12 mm thick with micro tegular edged at all height with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and pattern having moisutre content less than 2%, humidity resistance of 99%, NRC 0.60 to 0.85 as per IS 8225-1987, non combustible as per BS 476 (Part-4) 1970 and light code description unit code No 429 Sub Head 26. New Technologies and materials reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T -grid of hot dipped galvanised iron section of 0.33 mm thick ( galvanised @ 120 gms/ sqm including both sides) comprising of main T- runners of size 15x 32mm of length 3000mm, cross T of size 15 x32 mm of length 1200mm and secondary intermediate cross T of size 15 x 32 mm of length 600 mm to from grid module of size 600 x 600 mm, suspended form ceiliing using galvanised mild steel items (Galvanised @ 80 gm/sqm) i.e. 50 mm long, 8mm outer diameter M-6 dash fastners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85 x 25 x 2mm. galvanised iron perimeter wall angle of size 24 x 24 x 0.4 mm of length 3000 mm to be fixed on perimeter wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall SS screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge including dismantling existing asbestos sheet false ceiling textile coverings including frames (if any) and cover fillets complete all as specified and directed. NOTE : -Unit rate quoted against this item shall also includes taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface effected for this area etc complete all as specified and directed.
M&L for granule textured homogenous wall finishing system consisting of two component system of dry granules (25 Kgs Pack) made of 92 % silica particles coated with fade resistant pigments , 100% arcylic polymer bondring agent (5 Kgs Pack with the applied thickness of the coating being between 0.8 mm to 1.2 mm to be applied on cured , smooth level plastered surface , as per manufacturer's direction , applied by approved applicator of the manufacturer as per direction / supervision of Engr-in-Charge, all complete , The above textured coating should confirm to surface spread of flame class of BS 476 part 7 : 1971 and pull off strength of the coating to meet JISA 6909 all as specified and as manufacturers specifications/ instruction . Make :- Bakelite Hylam limited or equivalent approved by GE
Bairagi Builders (BID ID -3332423)
KULWANT SINGH (BID ID -3336533)
SARJIT SINGH AND CO. (BID ID -3327688)
Puneet Sharma (BID ID -3327899)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .