Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAdmitted-Finance 1 C 1 NEW ROHTAK ROAD KAROL BAGH NORTH WEST DELHI 110005 INDIA | CENTRAL DELHI | DELHI | 110005 | L1 | Admitted-Finance | |
| 2 | L2₹26.3 L+₹60,550 (2.36%)Admitted-Finance A 86 MANISH MARG NEMI NAGAR NR GANDHI PATH VAISHALI NAGAR JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L2 | Admitted-Finance | |
| 3 | L3₹26.4 L+₹65,047 (2.53%)Admitted-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L3 | Admitted-Finance | |
| 4 | L4₹26.4 L+₹66,536 (2.59%)Admitted-Finance III A 28 GF VAISHALI GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | L4 | Admitted-Finance | |
| 5 | Rejected-Technical 0 0 RAMNAGAR FATEHPUR ROAD KADIRABAD GRAM BUDHWAL PARGANA AND TEHSIL RAMNAGAR BARABANKI UTTAR PRADESH 225202 | BARABANKI | UTTAR PRADESH | 225202 | - | Rejected-Technical Not Eligible |
| Sl No | Description | Qty | Unit | VOLKS ENERGIE PVT LTD L3 | AQUATICS ENIGINEERS L1 | GAYATRI AIRCON PRIVATE LIMITED L4 | LIFE STYLE INTERIORS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply , Installation , Testing , Commissioning of 4.0 TR CASSETTE type, 4 WAY, Inverter AC , 5 star rated Air Conditioner units , evaporator coil, air cooled condenser with hermitically sealed scroll type compressor, condenser coil, propeller fans controls suitable for operation on 415 V +/- 10%, 50 Hz, Three Phase AC Supply and capable of performing cooling, dehumidifying, air circulating, filtering etc., remote control, including provision of suitable angle iron stand for outdoor units, handing arrangement for indoor, supply & fixing of drain pipe upto 3.0 mtr. & supply & fixing of liquid & gas refrigerant piping with insulation i/c Silver foil wrapping upto 3.0 mtrs , as per technical specifications, complete as required. | 8 | each | 1,50,000 ₹12,00,000 | 1,25,000 ₹10,00,000 Lowest | 1,28,926 ₹10,31,408 | 1,33,100 ₹10,64,800 |
| 2.00 | Supply, Installation, Testing, Commissioning of 2.0 TR wall mounted Air Conditioner unit , Inverter AC, 5 star rated, evaporator oil, air cooled condenser ,condenser coil, controls suitable for operation on 230 V +/- 10%, 50 Hz, AC Supply and capable of performing cooling, dehumidifying, air circulating, filtering etc., remote control, including wall mounted stand for outdoor units, 05 years warranty on compressor and supply & fixing of drain pipe upto 3.0 mtr. & supply & fixing of liquid & gas refrigerant piping with insulation i/c Silver foil wrapping upto 3.0 mtrs , cabling & electrical connections, complete as required. | 13 | each | 59,800 ₹7,77,400 | 50,000 ₹6,50,000 | 48,999 ₹6,36,987 Lowest | 57,700 ₹7,50,100 |
| 3.00 | Supplying and fixing refrigerant extra copper piping suction & discharge, with power supply wire, communication & insulation, silver foil for outdoor as suitable for 1.5TR/2.0TR/4.0 TR AC complete as required. | 100 | meter | 1,060 ₹1,06,000 Lowest | 1,300 ₹1,30,000 | 2,000 ₹2,00,000 | 1,350 ₹1,35,000 |
| 4.00 | Supplying and laying UPVC drain pipe of 25 mm dia. from indoor unit to drain point for Tower AC complete as required. | 100 | meter | 110 ₹11,000 Lowest | 150 ₹15,000 | 200 ₹20,000 | 180 ₹18,000 |
| 5.00 | Supplying and laying of PVC Trunking with cover on surface of 100 x 50 mm size to cover the AC refrigerant piping of Tower type AC unit complete as required. | 50 | meter | 240 ₹12,000 Lowest | 500 ₹25,000 | 250 ₹12,500 | 275 ₹13,750 |
| 6.00 | Supplying & laying of 3 x 2.5 Sq. mm copper conductor power cable FRLS insulated wire on surface for AC unit system, complete as required. | 100 | meter | 170 ₹17,000 | 120 ₹12,000 Lowest | 200 ₹20,000 | 230 ₹23,000 |
| 7.00 | Dismantling of existing split AC units 1.5 TR /2.0 TR/Cassette AC/ window AC, including copper piping, wire, etc., and keeping all these units from the site to the AAI store in AAI colony, complete as required. | 17 | JOB | 525 ₹8,925 | 300 ₹5,100 Lowest | 1,500 ₹25,500 | 1,800 ₹30,600 |
| 8.00 | Supply, Installation, Testing, Commissioning of water cooler with 40 LPH and 80 litres storage capacity suitable for operation on 230 V +/- 10%, 50 Hz, single phase AC Supply and capable of performing cooling & suppy & fixing of liquid & gas refrigerant as per technical specifications, complete as required. | 3 | each | 30,000 ₹90,000 Lowest | 55,000 ₹1,65,000 | 65,336 ₹1,96,008 | 35,500 ₹1,06,500 |
| 9.00 | Supply, Installation, Testing, Commissioning of water Purification Units (RO) with 50 LPH capacity UV, sediment filters, Ultrafiltration with suitable for operation on 230 V +/- 10%, 50 Hz, single phase AC Supply and capable of performing cooling & supply & fixing of drain and inlet piping as per technical specifications, complete as required. | 3 | each | 40,000 ₹1,20,000 | 70,000 ₹2,10,000 | 32,000 ₹96,000 Lowest | 40,000 ₹1,20,000 |
| 10.00 | Supply of XLPE/PVC insulated, PVC sheathed aluminium conductor power cable of 1.1KV grade confirming to IS 7098(Part I) 1987 with upto date amendments etc as required for the following sizes (Makes: As per approved list)
a) 3.5Cx35 sqmm | 100 | meter | 245 ₹24,500 Lowest | 700 ₹70,000 | 866 ₹86,600 | 270 ₹27,000 |
Tender Value
₹27.7 L
EMD Value
₹83,055
Closing Date
3 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGM(Engg-E)
Pantnagar Airport
SITC of additional Airconditioning unit for Terminal Building other areas at Naini Saini Airport Pithoragarh
2026_AAI_290433_1
AAI/Pantnagar/NIT-02 dated 11.09.2026
Open Tender
Electrical Works
Works
60 days
Pithoragarh Airport
As per DNIT
3 documents required · 3 mandatory
₹1,180
₹83,055
13 Oct 2026
11 Sept 2026
5 Oct 2026
11 Sept 2026
3 Oct 2026
11 Sept 2026
11 Sept 2026 - 18 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply , Installation , Testing , Commissioning of 4.0 TR CASSETTE type, 4 WAY, Inverter AC , 5 star rated Air Conditioner units , evaporator coil, air cooled condenser with hermitically sealed scroll type compressor, condenser coil, propeller fans controls suitable for operation on 415 V +/- 10%, 50 Hz, Three Phase AC Supply and capable of performing cooling, dehumidifying, air circulating, filtering etc., remote control, including provision of suitable angle iron stand for outdoor units, handing arrangement for indoor, supply & fixing of drain pipe upto 3.0 mtr. & supply & fixing of liquid & gas refrigerant piping with insulation i/c Silver foil wrapping upto 3.0 mtrs , as per technical specifications, complete as required. | 8 | each | - | - |
| 2 | Supply, Installation, Testing, Commissioning of 2.0 TR wall mounted Air Conditioner unit , Inverter AC, 5 star rated, evaporator oil, air cooled condenser ,condenser coil, controls suitable for operation on 230 V +/- 10%, 50 Hz, AC Supply and capable of performing cooling, dehumidifying, air circulating, filtering etc., remote control, including wall mounted stand for outdoor units, 05 years warranty on compressor and supply & fixing of drain pipe upto 3.0 mtr. & supply & fixing of liquid & gas refrigerant piping with insulation i/c Silver foil wrapping upto 3.0 mtrs , cabling & electrical connections, complete as required. | 13 | each | - | - |
| 3 | Supplying and fixing refrigerant extra copper piping suction & discharge, with power supply wire, communication & insulation, silver foil for outdoor as suitable for 1.5TR/2.0TR/4.0 TR AC complete as required. | 100 | meter | - | - |
| 4 | Supplying and laying UPVC drain pipe of 25 mm dia. from indoor unit to drain point for Tower AC complete as required. | 100 | meter | - | - |
| 5 | Supplying and laying of PVC Trunking with cover on surface of 100 x 50 mm size to cover the AC refrigerant piping of Tower type AC unit complete as required. | 50 | meter | - | - |
| 6 | Supplying & laying of 3 x 2.5 Sq. mm copper conductor power cable FRLS insulated wire on surface for AC unit system, complete as required. | 100 | meter | - | - |
| 7 | Dismantling of existing split AC units 1.5 TR /2.0 TR/Cassette AC/ window AC, including copper piping, wire, etc., and keeping all these units from the site to the AAI store in AAI colony, complete as required. | 17 | JOB | - | - |
| 8 | Supply, Installation, Testing, Commissioning of water cooler with 40 LPH and 80 litres storage capacity suitable for operation on 230 V +/- 10%, 50 Hz, single phase AC Supply and capable of performing cooling & suppy & fixing of liquid & gas refrigerant as per technical specifications, complete as required. | 3 | each | - | - |
| 9 | Supply, Installation, Testing, Commissioning of water Purification Units (RO) with 50 LPH capacity UV, sediment filters, Ultrafiltration with suitable for operation on 230 V +/- 10%, 50 Hz, single phase AC Supply and capable of performing cooling & supply & fixing of drain and inlet piping as per technical specifications, complete as required. | 3 | each | - | - |
| 10 | Supply of XLPE/PVC insulated, PVC sheathed aluminium conductor power cable of 1.1KV grade confirming to IS 7098(Part I) 1987 with upto date amendments etc as required for the following sizes (Makes: As per approved list)
a) 3.5Cx35 sqmm | 100 | meter | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.93 MB
Tendernotice_2.pdf
PDF • 7.20 MB
DNITSITCACFINAL.pdf
Tender Documents • 7.18 MB
BOQ_339045.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .