| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.7 LAccepted-AOC 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹59.8 L+₹5.0 L (9.22%)Rejected-AOC 275 GOLE BUILDING ROAD 1ST B ROAD SARDARPURA JODHPUR RAJ 342003 | JODHPUR | RAJASTHAN | 342003 | L2 | Rejected-AOC L2 bidder | |
| 3 | L3₹63.0 L+₹8.3 L (15.1%)Rejected-AOC | L3 | Rejected-AOC L3 bidder |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
17 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JODHPUR
HQ CWE AF JODHPUR
85891 E8 Repair to Joints and cracks using epoxy resin mortar and elastomeric concrete of rigid portion and application of PME on flexible portion at Jodhpur
2021_MES_447864_1
85891 E8
Open Tender
Civil Works
Item Rate
180 days
GE AF JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE AF JODHPUR
₹1.3 L
25 Aug 2021
2 Jun 2021
19 Jul 2021
2 Jun 2021
17 Jul 2021
22 Jun 2021
60 days
Amount
M&L for raking out sealing compound from existing expansion joints of dimension 25 mm to 30 mm wide and 25 mm deep, removing the debris from site by sweeping the concrete surface with brooms, cleaning with compressed air, treating sides and bottom of the joints with primer as per manufacturer's directions and filled with preformed closed cell polyethylene backup rod/strip of 25-32 mm dia, sealing with pitch free polyurethane grey sealant (minimum depth of sealant above backup rod shall be 10 mm) conforming to BS-5212 (Type FB) and applying masking tape on edges of joints to prevent accidental spillage of sealant and removing the masking tape after application of sealant complete all as specified and directed. Note :- Incase of any variation in width or depth of joint, the same is deemed to be included in quoted rates by the contractor as in Sch 'A'/BOQ items as above. The contractor shall not be entitled for any extra claim on this account.
M&L for raking out sealing compound from existing construction/dummy joints of dimension 20 mm to 25 mm wide and 25 mm deep, removing the debris from site by sweeping the concrete surface with brooms, cleaning with compressed air, treating sides and bottom of the joints with primer as per manufacturer's directions and filled with preformed closed cell polyethylene backup rod/strip of 25-30 mm dia, sealing with pitch free polyurethane grey sealant (minimum depth of sealant above backup rod shall be 10 mm) conforming to BS-5212 (Type FB) and applying masking tape on edges of joints to prevent accidental spillage of sealant and removing the masking tape after application of sealant complete all as specified and directed. Note :- Incase of any variation in width or depth of joint, the same is deemed to be included in quoted rates by the contractor as in Sch 'A'/BOQ items as above. The contractor shall not be entitled for any extra claim on this account.
M&L for raking out sealing compound from existing construction/dummy joints of dimension 10 mm to 15 mm wide and 25 mm deep, removing the debris from site by sweeping the concrete surface with brooms, cleaning with compressed air, treating sides and bottom of the joints with primer as per manufacturer's directions and filled with preformed closed cell polyethylene backup rod/strip of 13-18 mm dia, sealing with pitch free polyurethane grey sealant (minimum depth of sealant above backup rod shall be 10 mm) conforming to BS-5212 (Type FB) and applying masking tape on edges of joints to prevent accidental spillage of sealant and removing the masking tape after application of sealant complete all as specified and directed. Note:- Incase of any variation in width or depth of joint, the same is deemed to be included in quoted rates by the contractor as in Sch 'A'/BOQ items as above. The contractor shall not be entitled for any extra claim on this account.
Material and Labour Chipping and/or neatly Cutting of existing loose concrete at cracks on Runway/Taxi track/ pavement by using diamand cutter. Cutting of cracked portion shall not be less than 100 mm wide and 45 mm deep. Cleaning the dirt and all loose material fanned with air blower and air blasting the cleaned surface applying proprietory primer on surfaces to obtain tack and finally filling in Elastomeric Concrete, (Mix shall be prepared as per manufacturer) to obtained a true surfce and finally tooling the set surface with hand tools complete all as specified and directed. Note :- (i) The rate shall be include for providing masking tape at joints and formwork required if any at spalled joints edges. (ii) The quoted rate deemed to be included for making good to disturbed joint filling around the area where material is applied. (iii) All material shall only be procured directly from manufacturer.
Material and Labour Cutting existing loose patches / spalled edges of concrete pavement in square / rectangular/ triangular shape to a depth not less than 25mm removing debris out side MD land sweeping the patches with broom, cleaning with compressed air and applying epoxy resin mortar (proportion as specifed) incl necessary form work for sides of joints, sprinkle , a thin layer of dust free fine sand (QUARTS SAND 10 No) and applying a coat on top of surface with epoxy resin primer @ 0.45 Kg/Sqm and finally filling the joints with sealing compound complete all as spd and as directed by Engr-in-Charge (Sealing of joint shall be measured under respective item separately).
M&L for cleaning the surface by brushing with wire brushes for removing caked mud etc, sweeping with compressor air blower to remove all loose dust and dirt etc/taking out dust/ existing material with compressed air and making the surface free from dust, drying the surface and applying Two coats of polymeric modified emulsion (PME) by using self propelled emulsion distribution uniformly or towed emulsion pressure sprayer , equipped for spraying the PME uniformly and mopping the total undiluted PME @ 1.00 litre per sqm in two coats in ratio 1:1 (PME: water) and ensure uniform finish of total area complete all as specified and directed. Note:- The tenderr shall take into consideration the following points while quoting his rate for the above item:- (i) No price adjustment shall be applicable if excess quantity of polymer modified emulsionm (PME) than that mentined above is used, depending upon condition of the surface to be treated. (ii) Special care shall be taken to fill gaps/cracks with 6mm to 2.36 mm size coarse sand as per manufacturers instructins and quoted rate is included for repir of gaps/cracks. (iii) Cost of trial patch 15mx15m deemed to be included in rates quoted for above item.
Supply & fixing in repairs taxiway/runway sign board having UV protected face plate on both sides not more than 1.0 Sqm each consisting of non metallic materials support structure having min. tensile strength 4000 Kg/Sqcm impact strength of 139 Kg/Sqcm, and able to withstand wind speed of 30 m/s, with high intensity prismatic grade retro reflective sheeting as base and with cut out message (legends borders letters numerals etc) sign board frame shall fixed in frangible coupling embeded in PCC 1:2:4 type B1 block of size 15cm x 15cm x 15cm complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs taxiway/runway sign board having UV protected face plate on both sides size exceeding 1.0 Sqm but not exceeding 1.5 Sqm each consisting of non metallic materials support structure having min. tensile strength 4000 Kg/Sqcm impact strength of 139 Kg/Sqcm, and able to withstand wind speed of 30 m/s, with high intensity prismatic grade retro reflective sheeting as base and with cut out message (legends borders letters numerals etc) sign board frame shall fixed in frangible coupling embeded in PCC 1:2:4 type B1 block of size 15cm x 15cm x 15cm complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs taxiway/runway sign board having UV protected face plate on both sides size exceeding 1.5 Sqm but not exceeding 2.0 Sqm. each consisting of non metallic materials support structure having min. tensile strength 4000 Kg/cm2 impact strength of 139 Kg/cm2, and able to withstand windspeed of 30m/s, with high intensity prismatic grade retro reflective sheeting as base and with cut out message (legends borders letters numerals etc) sign board frame shall fixed in frangible coupling embeded in PCC 1:2:4 type B1 block of size 15cm x 15cm x 15cm complete all as specified and directed by the Engineer-in-Charge.
Demolition of PQC of any description & in any position not otherwise specifically provided for (unreinforced)
M&L for pavement quality concrete (PQC) of flexural strength 45 kilogram per sqcm in field as per design mix (as per IRC 44-2017) thickness of concret 300-350mm using non circular synthetic polyster fibre reinforcement @ 0.25 % by weight of cement including form work for laying in bays complete all as specified and as directed by the Engr-in-Charge. Note :- (i) Admixture is if required as per desin mix shall be added. Cost of Admixture including dosage plant and labour for mixing shall be measured and paid under respective items of this schedule. (ii) Polyester triangular fibres as secondary reinforcement mixed in concrete shall be measured and paid for separataly under respective item of this schedule. However, mixing shall be deemed to be included in the quoted rate (the constant shall be apply based on design mix). (iii) Construction joints, dummy (construction joints and expansion joints shall be measured and paid separately under respective items. (iv) Deduction shall be made in PQC for quantity for expansion joints. (v) As per IRC provision minimum cement content is 360 Kg/cum for the purpose of pricing this item, the cement content shall be considered as 400 kg/cum. Minus price adjustment shall be made based on quoted rate for supply only cement, incase of quantity of cement is used less than 400 kg/cum. However No plus price adjustment shall be made to the quoted rate of excess quantity of cement used beyond 400kg/cum. (vi) The quoted rate shall deemend to be include the cost cement mortar bund. (vii) The cutting of joint will be done using diamond cutter.
Removing of concrete material outside MD land complete all as specified and directed by Engr-in- Charge.
Material and Labour for refixing of stopbar lights (dia 200 mm to 250 mm and depth 150mm to 300 mm) in PQC(depth up to 350mm) by forming / cutting core using diamond core cutter of dia 200 mm to 250 mm and up to full depth of PQC, refilling of the remaining gap with elastometic concrete ( mix shall be prepared as per manufautrer's instructions) after cleaning the dirt, all loose material fanned with air blower and applying primer on the surface, forming joint of width 25 to 30mm and depth up to 100mm of length up to 23.5 meter for laying PVC pipe for passing cables for power supply to stopbar lights and joint of width 10mm and depth up to 50 for laying cable from conduit to stopbar light using diamand cutter and filled the gap with polyurethene sealant (Minimum depth of sealent 20 mm ) after fixing 30 mm dia polythene backup rod for 25 to 30 mm wide joint and 12mm dia polythene backup rod for 10mm wide joint priming the sides and applying masking tap on edge to prevent accidental spillage of sealent on top surfaces and to give neat finish to the sealent in position as required complete all as per manufacturer's instruction as specified and directed by Engineer-in-Charge. Note :- (i) The stopbar lights will be supplied by the department and cost of same not included in the item. (ii) The quoted rate deemed to be included for making good to edges of PQC around stopbar lights. (iii) The quoted rate shall included cost of forming / cutting core using diamond core cutter ,refilling of the remaining gap with elastometic concrete, forming/cutting required joints for laying supply cable to the stopbar lights using diamond cutter,polyurethene sealant, primer, polythene backup rod, masking tap, etc. (iv) The cost of PVC pipe and power cables will be measured and paid separately.
Supply & fixing for laying of Secondary cable used in runway lighting system of 5KV,6.6A ,4Sqmm single core multistranded copper cable in PVC conduit of size 25mm.cable should have impedence of 50M ohm.Cable has to lay in trench of 25mm width trench in PQC in PVC conduit as directed by Engr in Charge.
Supply & fixing secondary cable connector male and female combined used in Air Field Lighting system suitable for cable size 4 sqmm single core 5KV,6.6 A as directed by Engr-in-Charge.
Supply & fixing PVC pipe of size 25mm for laying of primary and secondary cable used in Air Field Lighting System as directed. Note for item No 13, 14 & 15 :- Old retrived cable to be deposited to department. Other allied items will also be retrived and deposited to department.
M&L for cutting out flexible surface from existing joints of dimension 12mm wide and 25 mm deep, removing the debris from site by sweeping wire brushing, cleaning with compressed air, and applying sides and bottom of the joints with primer and sealing with bitumen based sealant conforming to IS 1834-1984, complete all as specified and directed. Note: Manufactures insturctions to be complied with IS 1834-1984
Supply only for HDPE pipe of size 150 mm dia as such scalefor 0.4 Mpa pressure complete all as specified and directed.
JANGID BUILDERS
Jeet Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .