Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L3₹37.5 L+₹5.8 L (18.3%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 3 | L4₹38.5 L+₹6.8 L (21.4%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 4 | Rejected-Technical | - | Rejected-Technical NON FURNISH OF DOCUMENT | |
| 5 | Rejected-Technical AT PO HINJILICUT GANJAM | HINJILICUT | GANJAM | ODISHA | - | Rejected-Technical NON FURNISH OF DOCUMENT |
Tender Value
₹35.3 L
EMD Value
₹35,290
Closing Date
10 Feb 2021, 5:00 pmClosed
Execurive Engineer ,RWSS Division, Berhampur
Near Jarada Bunglow, Berhampur
Laying of pipelines, Construction of valve Chambers, bore well platform,Construction of 50KL ltrs capacity RCC ESR,Providing 100PERCENT FHTC etc.in connection with to PWS to Kalabada under Chikiti Block.
2021_RWSS_65820_2
EERWSSBAM- 26 ( D ) / 2020-21
National Competitive Bid
Civil Works - Water Works
Item Rate
210 days
PWS to Kalabada under Chikiti Block
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
₹35,290
Yes
13 Sept 2021
27 Jan 2021
11 Feb 2021
27 Jan 2021
10 Feb 2021
27 Jan 2021
27 Jan 2021 - 3 Feb 2021
Amount
Laying of pipe line ,Head works, Other Balance Works
Supplying all materials labour T&P for construction of Compound wall .Laying, testing and commissioning of Rising main & Distribution system pipe line such as UPVC,HDPE,ASTM, G.I /CI pipes line etc along with required fittings & specials and construction of valve chamber, bore well platform,individual house hold connection, installation of submersible pump with motor in deep Tube well etc.as per detail scope of work & technical specification, quantity of work mention in Schedule-I in DTCN and in ( Annexure-A to C). Materials as required shall be supplied by the Contractor as per terms and condition of DTCN & all dimensions are as per Schedule-I in DTCN and as per direction of Engineer in Charge . All work shall be completed in such a manner that all house hold of entire village will get required quantity of drinking water with residual head of 7m without any likage in the entire PWS system as per direction of Engineer-in-charge.
Construction of 50,000 LTR OHR WITH 12M STAGING Supplying of all labour,T&P,material including taxes for soil testing ,supply of design, drawing, construction,errection,testing & commissioning etc. of RCC elevated storage reservoir of 50,000 ltrs capacity with necessary staging height of 12 mtr consisting of cylindrical container with minimum 6 nos RCC columns and circular dome with full raft using CC M-25 with RCC stair case as per approved drawing,supplying, fitting & fixing of 80 mm medium grade GI pipe Tata/Jindal/Sail make confirming to IS specification of required length from production well to ESR & ESR to rising main including in-let,out-let,over flow & washing line of ESR,use of 32 mm GI pipe for Gallary and vertical post. and Aluminium ladder inside and outside the ESR,CI puddle collar,0.6 m dia CI manhole cover at dome , RCC vent with brass jally, lightening arrestor and water level indicator etc. complete as per direction of the Engineer - in- Charge. (The contractor is to approve all structural design & drawing from State Technical Agency IGIT,Saranga /CET,BBSR /VSSUT,Burla /NIT,Rourkela/IIT,BBSR at his own cost)
DILIP KUMAR SAHU
PRAFULLA KUMAR PANDA
Sukanta Panigrahi
Rajesh Kumar Sahu
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .