Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹102.6 Cr
EMD Value
₹5 L
Closing Date
23 Nov 2026, 5:30 pmDue today
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
MR CGMSC ENGG Creator(DFLT)
BILASPUR
“Construction of Planning, Designing, Engineering, Procurement of 300 Bedded District Hospital Building with 30 Bedded Trauma Care Unit (Up Gradation of 100 Bedded District Hospital) and Allied infrastructure development work at Raigarh, District Raigarh, Chhattisgarh” including one year of operation and maintenance of services.
203695
Ref.No.:6800/CGMSC/NIRMAN/2026-27, Date-29/10/2026
OPEN TENDER
WORKS
ITEM RATE
24 days
BILASPUR
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
20 documents required · 20 mandatory
Chhattisgarh Medical Services Corporation Ltd. (CGMSC)
WORKS
MR CGMSC ENGG Creator(DFLT)
OPEN TENDER
ITEM RATE
OPEN TO ALL
BILASPUR
TENDER SECTION
CGMSC L
120
24
No
10
203695
23 Nov, 2026 5:30:00 PM IST
26 Nov, 2026 11:00:00 AM IST
6 Nov, 2026 6:30:10 PM IST
Ref.No.:6800/CGMSC/NIRMAN/2026-27, Date-29/10/2026
“Construction of Planning, Designing, Engineering, Procurement of 300 Bedded District Hospital Building with 30 Bedded Trauma Care Unit (Up Gradation of 100 Bedded District Hospital) and Allied infrastructure development work at Raigarh, District Raigarh, Chhattisgarh” including one year of operation and maintenance of services.
500000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
1025521000.00
2
1025521000
AS PER NIT
AS PER NIT
AS PER NIT
10000.00 INR
16d 22h 39m
20 documents required · 18 mandatory · 2 optional
₹10,000
₹5 L
23 Nov 2026
6 Nov 2026
26 Nov 2026
6 Nov 2026
120 days
Name of Project:- PROPOSED GOVERNMENT MEDICAL COLLEGE, AT CHATTISGARH
Project Abstract- Civil and Electrical Works
S.No. Name Of Project Sub Head Amount DSR Amount NSR Amount TOTAL Remarks
1 Medical College (Academic Block) With Examination
Student Indoor Sports Facility
Boys Hostel- 388 Cap:-136 (Double seated) and 68 (Single seated)
Girls Hostel- 388 Cap:-136 (Double seated) and 68 (Single seated)
Intern Male Hostel (56 units)
Intern Female Hostel (56 units)
Director Residence
Supritendant Residence
Residence Type-D (8 units)
Residence Type-E (16 units)
Residence Type-F (16 units)
SUB Station/Services
Pump Room With UG Tank
Sports Facilities
Sub Total Building
Internal & External plumbing 194806216.13020003 52055379.49763915
Fire Fighting work 50322792.76451118 3384677
Site Development
Add GST @ 6% of Total
Internal & External Electrical 363445303.34640014
Add Contigency charges @ 3%
Add CGMSCL charges @ 5% on Sub total B
Note: The work is to be executed on Detailed Design, Engineering, Procurement & Construction (EPC) Mode basis following the item descriptions as mentioned below in line with the scope of work/drawings/tender etc. The Engineer-in-Charge may change/modify these items due to functional or site requirements and the contractor shall carry out the work without any additional cost /claim as per direction of Engineer in Charge. In case any activity though specifically not covered in the following list but the same is covered under BOQ/scope of work/ scope of supply/ specification/ drawings etc. no extra claim on this account shall be entertained, since these items are to be read in conjunction with all other documents forming part of the Contract. These items shall include but not limited to the following:
1 Disposal of excavated rock by mechanical transport including loading, unloading and stacking for a lead upto 10.00 Km.
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
In all types of soils.
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
In ordinary rocks.
In hard rocks where blasting in prohibited.
Extra for every additional lift of 1.5 m or part thereof.
All kinds of soil
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 10km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
Providing and mixing water proofing material in PCC/ RCC work in the proportion recommended by the manufacturer.
Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil..
Making 50mm thick plinth protection of plain cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with sand including finishing the top smooth.
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work.
M-25 Grade minimum
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
Thermo-Mechanically treated bars FE 550D
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
i Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
ii Wall of any thickness including attached pilasters, buttresses etc. in super structure.
iii Columns, Pillars, Piers and likes- rectangular or square in shape
iv Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
v Beams, lintels, cantilevers & walls
vi Stair cases of all types excluding spiral and folded plate type, including risers and landings
vii Weather shade, chhajja, Cornices and mouldings
Extra for additional height every 1m or part thereof where height of staging for form work exceeds 4.0 metre with adequate bracing, propping etc at all levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured):
Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints.
Providing and making 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width: Drip course
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063).
Floor Joint of 100 mm gap
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063)
Wall Joint of 100 mm gap
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063).
Roof Joint of 100 mm gap
Brick work with non-modular well burnt (open bhatta) clay bricks of crushing strength not less than 20 kg/sqcm and water absorption not more than 25% in foundation and plinth in:
Cement Mortar 1:6 (1 Cement : 6 Coarse Sand)
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand)
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level:
Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry.
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/230mm/ 300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately)..
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately).
Red sand stone - 30mm thick gang saw cut stone
White sand stone - 30mm thick gang saw cut stone
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin- charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid).
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge.
STRUCTURAL GLAZING AND ALUMINIUM COMPASITE PANEL
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers..
Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 17025
Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr
Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.
Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml
Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm
Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.
Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in- Charge.
Providing and fixing slear float toughened glass door or partition in required thickness frameless in appropriated sizes inclusive of edge molding polish and making required size slot or hole for patch fitting/hardware etc. The glass to be assembled together with patch fitting and hardware in proper alignment with all labour tools and tackles etc compicte. (Patch fittings and hardware to be paid for separatelv).
Providing and fixing flush door shutters, conforming to IS 2202 (Part 1), interior grade, commercial type, core of block board construction with frame of first class hard wood and well matched commercial ply veneering with vertical grains, cross bands and face veneers on both faces of shutters excluding hinges.
35 mm. thick (single leaf)
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).
Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Frame size 50 x 100 mm
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :
35 mm thick shutters
with ISI marked M.S. pressed butt hinges bright finished of required size
Kiln seasoned and chemically treated hollock wood
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 4 mm thickness
With float glass panes of 5 mm thickness
Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading
Providing and fixing ISi marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete :
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete.
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete.
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete.
Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete.
Providing and fixing IS: 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc complete.
Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastner with necesary stainless steel screws, all complete as per direction of Engineer-in-charge.
Providing and fixing factory made Kitchen Cabinet hutter/Partition 20 mm nominal thickness of approved shade, quaity and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity. Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge.
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of. E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately.
Structural steel work riveted or bolted or welded in built-up sections, trusses and frames work upto a height of 5m above plinth level, including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer..
Electric resistance or induction butt welded tubes Grade-300
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. SS Grade 304
Providing and fixing M.S. frames of doors, windows, ventilators and cupboards joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
MS tubular frames
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring.
80x1.25 mm M.S. laths
Providing and fixing 27.5cm long wire spring for rolling shutters.
Providing and fixing M.S. sheet top cover for rolling shutter.
Providing and fixing ball bearing for rolling shutters.
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting upto 30 cm. height with cement mortar 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement including rounding of junction with floor.
18 mm thick in two layers of 12mm and 6mm
15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above)
Granite stone black
25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm)
Mirror polishing on marble work/ Kota stone/ Granite work where ever required to give high gloss finish complete.
On walls/ Floor
KOTA stone slab 25mm thick in risers and treads of steps, skirting dado and pillar laid in 12mm (Average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (single stone is to be used for riser and treads of steps and the width of stone for skirting and dado shall be equal to the height of skirting/ dado up to length of 1.0 M.)
Extra for nosing in steps and treads of Kota stone slab.
Providing and laying rectified ceramic glazed floor tiles of size 300x300mm and above conforming to IS : 15622 of approved make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.
Size above 300x300mm
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.
Size above 200x300mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Glazed Vitrified tiles Matt/Antiskid finish of size
Size of Tile 600 x 600 mm
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.
Size of Tile 600 x 600 mm
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.
15mm thick Granite work (machine cut, table rubbed & mirror polished) for wall lining (veneer work) in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing with cement mortar 1:2 (1 white cement: 2 marble dust) mixed with matching pigment. (Area of slab should be over 0.5 sqm).
Granite stone black
15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish.
Granite stone black
Extra for providing edge moulding to 15mm thick stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Extra for fixing marble /granite stone in facia and drops of width upto 150 mm with epoxy resin based adhesive instead of cement mortar including cleaning etc. complete.
Extra for making opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including making necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tile including cleaning of joint etc complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :
Light shade using white cement
Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm
Pigment Coloured (rubber mould) precast interlock concrete blocks
ROOFING & CEILING WORK
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with
recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum moisture resistant board.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing.
Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing
& finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with:
8mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.
Proving and fixing Acoustical Suspended Ceiling System made of tiles of size 595x595mm and specified thickness as approved by Engineer-In-charge, in true Horizontal Level Suspended on inter locking metal grid of hot dipped galvanised steel sections (galvatised @120 gsm both side inclusive) consisting of main "T" Runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 thick (minimum) sheet, spaced at 1200mm center to center and cross "T* of size 24x38mm made of 0.30 thick (minimum) sheet, 1200 mm long spaced between main "T at 600mm center to center to form grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24×38mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200×600 mm panel to form grids of 600x600 mm and wall angle of size 24x24mm and laying false ceiling tiles of approved texture in the grid, cutting/ making opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc wherever required. Main "P" runner to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4mm dia Gl adjustable rods with galvanised butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along main "I". Bottom exposed width of 24mm of all "f* sections shall be pre-painted with polyester paint, all complete for all heights as per specification drawings or as directed by Engineer-In-Charge.The tiles should have Humidity resistance (RH) of 99%, Light Reflectance >83%,
Thermal Conductivity K=0.052-0.57w/mk, colour white, fire performance UKclass0/Class I(BS476pt-6and7) in module size of 600x600x16 mm with Bio Block coating on the face of the tile, suitable for green building application, with recycled content of 38-41%. Ceiling height up 3.5 mt from adjacent floor level.Extra height to be paid separately.
With 16 mm thick bevelled/ tegular edged mineral fibre false ceiling tile (NRC 0.55 to 0.6)
Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorptions ? 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
Providing and making 6mm thick cement plaster of mix:
In Cement mortar 1:3 (1 cement : 3 fine sand)
Providing and making 12mm thick cement plaster of mix:
In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
In Cement Mortar 1:6 (1 cement : 6 fine sand)
White washing with lime to give an even shade :
New work (three or more coats)
Providing and making 18 mm thick cement plaster with under layer of 12mm thick cement plaster 1:5 (1 cement : 5 fine sand) finished with a top layer of 6mm thick cement plaster 1:3 (1 cement : 3 fine sand)..
Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer.
Extra for plastering of exterior walls when height exceeds 10m above ground level for every additional height of 3.0m or part thereof.
Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even.
Wall painting with acrylic premium emulsion (plastic) paint of required shade to give an even shade.
On new work (two or more coats)
Painting exterior surface with TEXTURED exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:
On new work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm
Painting on new work (two or more coats) to give an even shade with:
Satin synthetic enamel paint
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately::
i For fixed portion.
Powder coated aluminium (minimum thickness of powder coating 50 micron)
ii For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Upto 5mm depth and 5 mm width
Providing and laying water proofing treatment in sunken portion of WCs,bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment andsealing of all joints, corners, junctions of pipes and masonry with polymer mixedslurry.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size)
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage..
For vertical surface two coats @ 0.70 kg per sqm
For horizontal surface one coat @1.10 kg per sqm.
Providing anf fixing Combi. Finished Stainless Steel 316 glass door pull handles 450x25mm (pair of handle) dia with screws etc. complete:
Providing anf fixing Stain Finished Stainless Steel 316 glass door floor lock with screws etc. complete:
Providing anf fixing Stain Finished Stainless Steel 316 glass door stopper with screws etc. complete:
Supply and installation of 300mm x 600 mm x 20mm thick Terracotta tiles made entirely from natural raw materials derived from a sustainable source with superior finish, high strength, low maintenance , tested safety ,colour fast, highly resistant to all kinds of weather conditions , fire resistant with density 2.0- 2.4 g/sqcm, dry weight 30-32 kg /sqm, elasticity .305 x 105 as per ISO 17561, water abrasion value 3%, collapsible strength > 7*104N, anti fire performance grade A , thermal shock stability with no crack and burst after 10 times testing JC/T 1080-2008, sound proofing with reduce noise over 9 db , thermal conductivity 0.264 W/m@K, Wind pressure performance Positive 2 KPa OR 2.25 Kpa, Negative 2 KPa OR 2.25 Kpa GB/T 21086- 2007, Seismic performance over 10 grade GB/T 18575 \ GB5011, Acid resistant . Installation up to 10.0 mtr height with Aluminium sections frame as per structural design all complete as directed by Engineer – in – Charge
Providing and installation of Vinyl Sports Sheet Flooring manufactured by Armstrong or equivalent World Industries , Inc, 1.8m wide and 15 m long, having a nominal total thickness of 6.5mm. The wear surface shall be 0.7 mm and PUR coated with UV Treatment. Athleta shall conform to flammability Class Cfl as per EN 13501‐1;Shock Absorption more than 37%; sliding coefficient of 0.45‐0.65; energy return of 0.40m/s; vertical deformation of 2.8 mm and sound insulation of 23‐25 db. Impact Resistance of 8N/M (as per DIN18032); Abrasion Resistance of 7 mm, Indentation Resistance of 0.6mm (as per EN1016), Friction Coefficient of 0.6 (as per GB/T14833‐ 1993) and Rebound Coefficient of 0.86 (as per GB/T14833‐ 1993)
Providing and fixing Glass Reinforced Concrete (G.R.C) Panels casted with 'Spray Mix' concrete design in approved size, pattern, thickness of 40‐50mm on the outer Border & 25‐30mm for Internal member and shade. The Panels should be made from ‘43 grade’ Portland Cement manufactured by ‘JK Cement’ or ‘Nuvoco’ or ‘JK Lakshmi’ or Ultratech', White Quartz fine graded sieve Silica Sand, Alkali Resistant Glass Fibre manufactured by 'NEG Japan, Owens Corning ‘Saint Gobain’ or equivalent, Super Plasticizers manufactured by ‘Karochem’ or equivalent, Polymers manufactured by ‘Nova Polychem’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘Phenochem industries or equivalent. The Panels casting shall take place with layering methodology using‐ Direct Power Spray machines. The GRC Panels flexural strength average L.O.P should be above or equivalent to 6 N/mm² & M.O.R should be above or equivalent to 12 N/mm² for tests done on 28 days cured samples.
The fixing of Panels should be done using ‘Dry fixing’ method onto structural support members i.e. R.C.C, Brick work MS Framework. MS Galvanized CLAMPS & PINS also if required fasteners to be used of Steel Grip/ HP/ Wurth/ Hilti/ Fischer/ Klimas or equivalent. All cast in socket to be Epoxy Primer Coated. ELECTRODES to be used of Advani, Mangalam, Esab or Victor brand or equivalent. If there will be a requirement of Joint filling, then Elastomeric exterior grade paintable PU Sealant will be used. For final finishing of Panel one weather shield exterior grade water based diluted paint coat will be done if required. Vendors shall submit shop drawings of the same, the drawings to be duly approved by the Engineer in charge at site.
Providing and Fixing Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm or as required by approving engineer, made of a high density fibre board with minimum 595 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 5mm/ 13mm/ 21mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.59. The panels shall be mounted on special aluminium splines using clips provided by manufacturer and approved by Engineerin-Charge.
INSTALLATION: Install wooden battens of section 50x50mm or as approved on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for channelled woodworks provided by Manufacturer over the lowest and second wooden batten at an on-centre distance of 600mm. Install the Skirting of width 50mm or more as required Engineer-in-Charge and insert the tongue end of the panel in the skirting.
6mm thick Heat strengthened performance glass with reflective soft coating at face # 2 of silver shade on Clear Substrate of approved make having properties as visible Light transmittance (VLT) of 20 %, Light reflection internal 26%, light reflection external 31 %, Solar heat gain coefficient (.28), shading coefficient (0.33) and U value of 3.5 W/m2 degree K ,CRI value 92ra(d65). (VLT) of 20 %, Light reflection internal 26%, light reflection external 31 %, Solar heat gain coefficient (.28), shading coefficient (0.33) and U value of 3.5 W/m2 degree K ,CRI value 92ra(d65).
Providing and fixing of Pre Fabricated Aluminum Twin Sash Casement window Consisting of 1 sash of Glass , and one Fixed window. The extruded aluminium sections should be made from AW 6060 and AW 6063, Post-treatment T66 in accordance with EN 755-2, Tolerance In accordance with EN 12020-2, and suited for anodizing and powder coating. All profiles should be Non insulated Profiles. Corner connection Crimped/screwed with Aluminum Die Cast Cleats sealed with two-component glue (epoxy) on the outer frame and screwed . All Glazing gaskets Silicone compatible EPDM in accordance with TV 110, possible to vulcanize. System should be wih 3 layer gasket solution. Accessories should be used which are designed to be simple and rational to use. System with Euro Nut compatible hardware only. The Section used for Outerframe shall be of size 65.5 mm D x 45mm H . The Sash used shall be of size 30.5mm D x 59.5 H. There shall be one windows opening outside having glass. Hardware should be as per approved makes with rollers of capacity of 150Kg. All materials which are used in should be corrosion-resistant so that the good functioning in different environments is guaranteed and this for a period of min. 10 years.
This means that the article can be used in all environments and that there are no negative influences either on the aluminium or on the surface treatment. The Glass panel shall be with Multi point locking The system should allow the application of glazing or panels with thickness from 8mm to 22 mm. System should qualify Air tightness, max. Test pressure EN 1026; EN 12207(600pa), Water tightness EN 1027; EN 12208(900Pa), Wind load resistance EN 12211; EN 12210(class C E2400). System should have 10 year guarantee on properties, functionality and design, within restrictions defined by technical specifications, powder coating / anodising & 10 year guarantee on wearing parts only applies to normal and realistically foreseable use.
Providing and fixing of Pre Fabricated Aluminum Casement Fixed Windows . The extruded aluminium sections should be made from AW 6060 and AW 6063, Post-treatment T6 in accordance with EN 755-2, Tolerance In accordance with EN 12020-2, and suited for anodizing and powder coating. All profiles should be Non insulated Profiles. Corner connection Corner Cleat with Aluminum Die Cast Cleats sealed with two-component glue (epoxy). All Glazing gaskets Silicone compatible EPDM in accordance with TV 110, possible to vulcanize. System should be wih 3 layer gasket solution. System depth to be 56mm and height to be 48mm with minimum wall thickness of 2mm. Accessories should be used which are designed to be simple and rational to use. All materials which are used in should be corrosion-resistant so that the good functioning in different environments is guaranteed for a period of min. 10 years. This means that the article can be used in all environments and that there are no negative influences either on the aluminium or on the surface treatment.The system should allow the application of glazing or panels with thickness from 24 to 28 mm.
The external perimeter of aluminium sections should be coated with 50-60 Micron RAL colour powder coating, Qualicoat certified surface treatment only. Coating thickness according to norm ISO 2360:1995. System should qualify Air tightness, max. Test pressure EN 1026; EN 12207(600pa), Water tightness EN 1027; EN 12208(900Pa), Wind load resistance EN 12211; EN 12210(class C E2400) System should have 10 year guarantee on properties, functionality and design, within restrictions defined by technical specifications, powder coating / anodising & 10 year guarantee on wearing parts only applies to normal and realistically foreseable use. The section used shall be of size 56mm D x 48mm H
Providing and fixing of factory made uPVC casement window / Fixed Window & Casement Door (White Colour) comprising uPVC multi-chambered frame, Sash, & Mullion with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa.
All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. EPDM / TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 mm Float Annealed glass shall be provided in the sash with the help of uPVC glazing bead and hardware, i.e., friction hinge & single point handle (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.
Casement Window (Big Series) frame of size 67 x 62 mm & Sash / Mullion of size 67 x 78 mm.
Casement Door (Big Series) frame of size 67 x 62 mm & Door Sash of size 67 x 115 mm & Mullion (if required) of size 67 x 78 mm.
Fixed Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Supplying and stacking at site.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
Dry Lean Cement Concrete Sub-base as per IRC:SP-49 (Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.)
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Extra for providing and mixing hardening compound of approved quality as per manufacturer's specification in cement concrete.
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.).
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.
Using grade 'A' sealing compound conforming to IS: 1834..
Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bilingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge.
Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm
Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm
Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge. (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).
Overhead informatory road signage
Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge.
Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge)..
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Making bell mouth opening/ entrance of size 100x50x50 cm for drainage pipe under footpath, including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for shape of bell mouth, including plastering providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar 1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, shuttering & neat cement punning inside the bell mouth etc. all complete.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
450 mm dia RCC pipes.
600 mm dia RCC pipes.
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site well decayed cow dung manure from approved source, including loading, unloading and carriage upto 5 km (manure measured in stacks will be reduced by 8% for payment).
Rough dressing the trenched ground including breaking clods..
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
Fine dressing of the ground
Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/ and good earth to be paid separately).
Mixing earth and sludge or manure in proportion specified or directed.
Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth shall be paid for separately)..
In rows 15 cm apart in both direction.
With grass turf
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :
Holes 1.2 m dia and 1.2 m deep.
Holes 90 cm dia and 90 cm deep.
Holes 60 cm dia and 60 cm deep.
Holes 45 cm dia and 45 cm deep.
Half brick circular tree guard in modular well burnt clay bricks of crushing strength not less than 25kg/ sqcm, internal diameter 1.25 metre and height 1.2 metre above ground and 0.20 m below ground bottom two courses laid dry and top three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses being in dry honey comb masonry as per design complete:
Edging with modular well burnt clay bricks of crushing strength not less than 25kg/ sqcm laid dry length wise including excavation, refilling, consolidating with hand packing and spreading neatly surplus earth within a lead of 50 m :
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).
Excavation in dumped stones or malba including stacking of serviceable and unserviceable material separately and disposal of unserviceable material lead upto 50 m and lift upto 1.5 m disposed material to be neatly dressed.
Providing and fixing M. S. tree guard 45 cm square in plan, height 1.20 metre above ground level and 0.40 metre below ground level. The vertical members shall consist of four nos. angle iron of size 25x25x3 mm, 1.6 m long, one at each corner and 8 nos flat iron of size 25x3 mm, 1.2 m long. The vertical mambers shall be welded to 4 nos. 25x6 mm M. S. flats placed horizontally around the vertical member of the cage. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree. guard near the middle height and lettered CPWD/ PWD/ any other approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two or more coats of synthetic enamel paint of approved brand and manufacture over a coat of primer, complete in all respect.
Providing and fixing M. S. tree guard 50 cm square in plan, height 1.40 metre above ground level and 0.50 metre below ground level. The vertical members shall consist of four nos of angle iron of size 25x25x5 mm 1.9 long, one at each corner and 8 nos flat iron of size 25x5 mm 1.4 long. The vertical members shall be welded to 4 nos 25x6 mm M. S. flats placed horizontally around the vertical member of the cage. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two coats of paint of approved brand and manufacture over a coat of primer, complete in all respect.
Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge.
Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge..
Top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall thickness of 25.4 mm
Top inside dia 30 cm, outer bottom dia 20 cm, total height 30 cm with wall thickness of 25.4 mm
Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge..
Top inside dia 30 cm, outer bottom dia 20 cm, total height 30 cm with wall thickness of 25.4 mm
Providing and Displaying Ficus black vivion piller topiary (sylinder type) well developed with fresh & healthy 180 to 210 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and Displaying Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Ficus Long Island topiary well developed with fresh & healthy 5 to 6 ball specific size and shape 120 to 150 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Ficus nuda topiary well developed with fresh & healthy foliage 45 to 60cm spread 75 to 90 cm ht. bushy in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Ficus reginold well developed fresh & healthy foliage 60 to 75 cm spread 105 to 120 cm ht., Bushy in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 to 75 cm ht in 30 cm Earthen Pot as per direction of the officer-in-charge.
Providing and Displaying Cyprus Golden 30 to 45 cm ht. well developed good Golden colour foliage, Conial Shape in 25 cm Earthen Pots as per direction of the officer-in-charge.
Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Calliandra hybrida of height 75-90 cm. with 4-5branches in bag of size 25 cm as per direction of the officer-in-charge.
Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Bamboo Buddha valley with fresh & healthy 3 to 4 suckers having 75 to 90 cm ht. in 25 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge.
Providing and Displaying Ficus Retusa topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 180 to 210cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Golden Bottle brush Topiary well developed with fresh & healthy foliage 5 to 6 big ball 115 to 180 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)
ii Shrubs Plant
Supplying & Stacking of Selection No.1/doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Supplying at site :
R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarsesand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-incharge (cost of earth works in excavation, concrete works in foundation to be paid separately).
Supplying and fixing turn buckles and straining bolts for barbed wire fencing.
Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire
Building Branding Signage
Signage is made of 3D channel Latter, made from Following A) Front :- Front is to be made of 3.5 mm Acrylic and 3M/Avery/LG Cast vinyl of desired shade as per approval. Dual color vinyl film in desired day shade to be of cast acrylic without prininting the face of vinyl. B) Side :- Signage made of CNC channel bending machine made of exturded alloy 6063 thickness of 1.00mm confirming to BS 1474-1987 . 125 to 130 mm as side of 3D letter exturded alloy profile with front edge and border with provisioning of housing front Acrylic inside . Back of the extrusion must be provided with built in weather proof layer to prevent dust , moisture etc. Alloy to be anodize to 18 to 20 microns in copper/ bronze/ silver colour of approval shades. C) Illumination :- Signage is to be illuminated with LED module base LED made of OSRAM (with required power supplies). D) Back :- Back is to be made of 4mm thick ACP with 0.45 mm thickness Aluminum Foil on both sides. E) Timer:- Auto operated using L&T/Havells/schneider timer of required capacity.
Entry Gate Signage
Providing and fixing External Signage's made of SS 304 (brush finish) 1mm thk.sheet for Logo and letters with raising(letter depth of 50mm). Including all fittings, accessories, fixtures, fabrication.The signage will be front illuminated/hollow illuminated either back or front of the signage to be made of 4 mm thick acrylic. 3M/Avery/LG cast vinyl for desired colour with OSRAM make LEDS and IP 67 Grade powersupply fixed on the wall with necessary fixtures.
Campus Directional Signage
Double Sided Signage will be fabricated using ACP panel size 800x1200 as base duly fixed over modular aluminium extruded ultraedge section frame of 50mm depth of brand 247Sign/Vista System/ASB Neon having no screws visible outside powder coated to 40-50 microns. Text & Graphics will be in 3M HIP grade prismatic Retro-reflective self adhesive sheet duly digitally plotter cut and pasted on base on both side as per design. Signage will be grouted to RCC pedestal using MS Pole of 100X100x3000 mm with base plate size 300x300x10 mm duly powder coated of 40-50 microns in approved shade.
Traffic regulatory Signage ( Drop off/ Speed Limit / No Horn/ BASEMENT Entry/Exit)
A)POST :- Signage is to be made oF 100x100 mm 1800 mm High MS pole, Base Plate of size 250x250mm of thickness 10mm is to be used. Duly powder coated 50 microns in the desired colour. B) Panel-1 :- Panel size 400X110X1200 mm is to be made of 50x50x2 mm internal MS frame duly powder coated to 40-50 microns with ACP 4 mm thick, 0.5 mm aluminium foil, 3M / AVERY Prismatic Retro reflective sheet and approved color Overlay film on top having desired text and pictographs on both side post. C) Panel-2 :- Panel size 600X600 Sq/round with ACP 4 mm thick, 0.5 mm aluminium foil, 3M / AVERY Prismatic Retro reflective sheet and approved color Overlay film on top having desired text and pictographs.
Entry/ Exit Signage - Wall / Surface Mounted (IN/OUT/NO ENTRY/ NO EXIT)
Signage sides is to be made of 50 mm width, extruded alloy 6063 of brand 247Sign/Vista/Cosign having no screws visible outside. duly anodized 18-20 microns bronze / copper finish with in built in provision to received the sign face panel in 5 mm Acrylic on front and having provoison of hold the LED Modules . Sign face is to be made of graphic plotter cut vinyl as per graphic pasted over 5 mm thick white transluent acrylic. The panel should be made easily openable for maintinace point of view. Illumination :- The lighting for panel shall be achieved through LEDs and IP 67 Grade powersupply.
FIRE EVACUATION Photoluminicent Signages
Emergency Evacuation Signage :- Round Corner signages with radius 8 to 12 mm, made of 2 mm Rigid PVC sheet with premium photoluminicent of illumination upto minimum 4 hours. With UV printing for Graphic and text. Adhering to latest NBC Standards. Mounted using SS scews OR 3M VHB tape, as per directions of engineer incharge
a Stair Direction at landing
c Stair Floor Level Indicator
d Fire Safety Disclaimer
g Fire Extinguishers
i AHU/Electric Room
Evacuation Route Identification
Emergency Evacuation Signage :- Sandwhich Acrylic frame work of 5 mm + 5mm thickness. Signages made of premium photoluminicent of illumination upto minimum 4 hours. With ecosolvent printing for Graphic and text. Adhering to latest NBC Standards. Mounted using SS Spacers 18 mm x 25 mm, as per directions of engineer incharge. Signages to be bilingual/trilingual language.
Emergency Evacuation signage with battery backup
ITEM Name:- Edge Lit Emergency Signage MODEL - EMEX3726- Premium Casing:- Anodised Aluminium with Plastic / Metal Side Caps. Signages Over all size :- 375 x 260 mm Text Panel:- 8 mm Acrylic Back Up Duration :- 180 Minutes Primary Power Source:-AC - 150-240 Volt Luminare:- LED Battery Disconection Swith Power Consumption :- (3-5) Watt (0.018 to 0.023 Amp). Battery Capacity:- 2000 MAH Battery Type:- Lithium ION AC to DC Built in Adaptor Fuse for Circuit protection AC, Charging, EMERGENCY Indicators Emergency Test Switch Battery Minimum Discharge Protection Battery Maximum Charge Protection Installation:- In client scope through certified electrical contractor..
a BB Directional
Signage to be made of stainless steel sheet of 1 mm thick 304 grade brush finish including engraving/etching of letters of required size filled with colour as desired by engineer,fixing with ss screws on walls.signages to be bilingual/trilingual language.
c Instructional signs
AREA INDETIFICATION SIGNS
Curved Signages made of extruded 6063 grade alloy confirming to B.S. 1474-1987 with copper/brass finish anodizing in 18-20 microns. Minimum 1.5mm wall thickness of extrusion with provisioning of housing print and 1mm protective sheet in front side. Fixing arrangment made of anodised aluminium in Brass / Copper shade to be fixed at back side with Fastner . Alloy to be anodized to 18 to 20 microns . Side caps with 3 mm Thickness in molded PVC of matching color as that of anodising without paint, side caps to be fixed to main plate using SS L key screws or same color coated L key screws as anodising. signages to be bilingual/trilingual language with pictograph as required.
a Room indentification
b Department indentification
c Sub Department
d Wash room ( Wall mounted )
DIRECTORY SIGNS
Curved Signages made of extruded 6063 grade alloy confirming to B.S. 1474-1987 with copper/brass finish anodizing in 18-20 microns. Minimum 1.5mm wall thickness of extrusion with provisioning of housing print and 0.8- 1mm protective sheet in front side. Fixing arrangment made of anodised aluminium in Brass / Copper shade to be fixed at back side with Fastner . Alloy to be anodized to 18 to 20 microns . Side caps in pvc as per standard color (offer by 247SIGN) with 2mm aluminium anodised in same colour as main profile, side caps to be fixed to main plate using SS L key screws or same color coated screws as anodising. signages to be bilingual/trilingual language with pictograph as required.
a Service Directory (Top header profile 120 mm, 16 contant profile 105mm.)
b Floor Directory (Top header profile 120 mm, 10 contant profile 105mm.)
INTERNAL WAYFINDING SIGNS
Curved Signages made of extruded 6063 grade alloy confirming to B.S. 1474-1987 with copper/brass finish anodizing in 18-20 microns. Minimum 1.5mm wall thickness of extrusion with provisioning of housing print and 1mm protective sheet in front side. Fixing arrangment made of anodised aluminium in Brass / Copper shade to be fixed at back side with Fastner . Alloy to be anodized to 18 to 20 microns . Side caps with 3 mm Thickness in molded PVC of matching color as that of anodising without paint, side caps to be fixed to main plate using SS L key screws or same color coated L key screws as anodising. signages to be bilingual/trilingual language with pictograph as required.
a Wash room ( Wall Projected double side )
b WAY FINDING ( Celling Hung double side )
c Waiting Lobby ( Celling Hung Single side )
d Nurse Station ( Celling Hung Single side )
e Reception ( Celling Hung Single side )
f Counters ( Celling Hung Single side )
PARKING WAYFINDER SIGN for Basement
Double sided signage will be fabricated using 12+12 mm thick twin ultra slim edge modular aluminium extruded profile of copper/brass shade anodising in 18-20 microns with approved ACP as base duly fixed over on both sides and retro reflective vinyl duly digitally cut and pasted on ACP panels on both side. Signage will be hanged using SS cable/ SS chain with fastners..
LED LIT DISPLAY PANELS
EXTERNAL PROFILE & FRONT CLIP ON:- Made of alloy 6063 confirming to BS 1474-1987. Main load bearing frame profile to have minimum 2.5mm wall thickness made in Synchronization with front clip on profile having 1mm wall thckness. Main profile of depth 100 mm while 75 mm clip on front profile visible as front border. INTERNAL FRAME :- To be fixed using concealed MS frame work in shape of 'T' section using 2 nos of SHS 40x40x2 mm and 50x25x2 mm duly welded and coated with primer and two coats of enamel paint. Front :- Front made of 450 Gsm flex with Ecosolvent Printing. Tied using eyelet @ 3" interval. BACK : - Back is to be made of 4mm thick ACP with 0.45 mm thickness Aluminum Foil on both sides. Illumination :- Signage is to be illuminated with LED module (with required power supplies.
Poster Frame made of alloy 6063 heavy copper/bronze anodizing, clip on arrangement for easy change of insert. Use 2mm clear acrylic as a protection layer in the front.
Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required :
White Orissa pattern W.C. pan of size 580x440 mm
Providing and fixing vitreous china water closet (European type W.C.pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
White pedestal type
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete..
Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required.
Kitchen sink with drain board Size 510x1040 mm bowl depth 250mm
Kitchen sink without drain board Size 610x510 mm bowl depth 200 mm
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of brackets, cutting and making good the wall wherever required :
Size 450x300x150mm
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge
Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
Providing and fixing unplasticised PVC connection pipe with brass unions
15 mm nominal bore
Providing and fixing in position best Indian Health Faucet with 8mm dia 1 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:
Bib cock (400 grams)
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore ( for sink)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:
Angle valve for basin mixer and geyser points (450 grams)
Providing and fixing C.P. brass sink mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath) . 15 mm nominal bore
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:
Shower rose (revolving type) (150mm)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:
Stop cock (concealed) (600 grams)
Providing and fixing CP Brass 40 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:
Toilet paper holder
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing Ultra Thin Stainless Steel Hand Dryer (Heavy Duty EH 24S) of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
Providing and fixing sand cast iron S&S pipe as per IS: 1729 for soil, waste and vent pipes:
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe
75 MM SS 304 grade coupling with EPDM rubber gasket
100 MM SS 304 grade coupling with EPDM rubber gasket
Cutting holes more than 20x20 cm and upto 30x30 cm in walls including making good the same :
Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof.
Providing and fixing UPVC pipes complete with fittings and clamps, including cutting and making good walls etc. ( for wash basin & Urinal waste )
40 mm dia nominal bore
Providing and fixing upvc hooper
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :
100mm dia pipe.
Providing and fixing sand cast iron S&S trap of self cleansing design with screwed down or hinged grating with or without vent arm as per IS: 1729 complete, including cost of cutting and making good the walls and floors :
100 mm inlet and 100 mm outlet
100 mm inlet and 75 mm outlet
Providing and fixing sand cast iron S&S bend with access door of required degree as per IS : 1729, insertion rubber washer 3 mm thick, bolts and nuts:
Providing and fixing plain bend of required degree.
Providing and fixing sand cast iron S&S single equal junction with access door of required degree as per IS : 1729, insertion rubber washer 3 mm thick, bolts and nuts:
Providing and fixing centrifugaly cast iron single equal plain junction of required degree.
Providing and fixing sand cast iron S&S single unequal junction with access door of required degree as per IS : 1729, insertion rubber washer 3 mm thick, bolts and nuts complete:
Providing and fixing sand cast iron S&S single unequal plain invert branch of required degree as per IS : 1729:
Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.)
Providing and fixing sand cast iron S&S terminal guard as per IS: 1729:
Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required ouplers, jointing with seal ring conforming to IS : 5382 Laving 10 mm gap for thermal expansion etc complete.
110 mm dia pipe.
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
Access door cap
Double "Y" with or without door
Tee/ Tee with door/ Bend 45°/ Bend 90°
Plain reducing Tee
Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
g) Providing & fixing UPVC Coupler
a) Providing & fixing UPVC 90˚ elbow
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing 100 mm/110 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 sand)
Upvc spout (Pipe dia.110 mm)
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fttings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work including cutting chases and making good the walls etc.
20mm dia nominal outer dia pipes
25mm dia nominal outer dia pipes
32mm dia nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work-Exposed on wall
15mm dia nominal bore
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..
Internal work-Exposed on wall
65mm dia nominal bore
80mm dia nominal bore
Providing and fixing gun metal gate valve with wheel of approved quality.
20mm dia nominal bore
Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end):
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
65mm dia nominal bore
80mm dia nominal bore
Providing and fixing Butterfly Valve with IP 54 actuator with Control Panel and Two Point Magnetic Sensor for Automated Tank Filling System
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Capcity in Per Liters
RO Plant 3500 LPH (Liter per hour)
MGF Model WWMGF_FRP2162 Flow Rate : 5 M3/Hr Max. Design Pressure : 4 Kg/cm2 Service Velocity : 25 M/Hr Operation : Manual MOC : FRP ACF Model WWACF_FRP3072 Flow rate : 5 m3 /hr Max. Design Pressure : 4 Kg/cm2 Service Velocity : 18 M/Hr Operation : Manual MOC : FRP RO System Model WWSRO-3500 Permeate Flow rate : 3500 LPH Recovery : 75% Operating Hours : 10 hr Operation : Semi-Automatic (for hospital building )
RO Plant 500 LPH (Liter per hour)
PLANT CAPACITY - 500 LPH RECOVERY - 50% ELECTRICAL CONNECTION - 415 V, 3 PHASE, 50 HZ TDS - < 100 PPM
1000L STORAGE TANK AND DRINKING FOUNTAIN
RO Plant 250 LPH (Liter per hour)
PLANT CAPACITY - 250 LPH Treated Water Quality Turbidity : <1NTU pH : 6.5-7.0 Chlorides : < 10 ppm Sulphates : < 5 ppm TDS : < 150 ppm
500L STORAGE TANK AND DRINKING FOUNTAIN
Supply installation, testing and commissioning of water cooler Cooling Capacity150Ltrs. / Hrs.,Storage Capacity 150 Ltrs
Flat plate collector solar water heating system
Supply, Installation, Testing & Commissioning of 500 LPD Flat Plate collector based on thermosyphon circulation Solar water heating System suitable for 2.0 Kg/cm2 working pressure & 3 Kg/cm2 testing pressure comprising of 8 numbers of Flat Plate collectors, internal system piping, insulated hot water storage tank with heat exchanger, valves on inlet & outlet, temperature gauge, MS Angle frame etc. complete in all respect. Details of each items used in one 500 LPD system are mentioned below:
Solar Flat Plate collector having collector area should be min. 2 Sq, Mtr. Its include the collector stands & other acessories to joint the collectors each other. (Collectror should be BIS approved.) - 4 Nos.
Solar hot water storage tank capacity of 500 litre made up of SS-304L insulated with 100 mm rock wool insulation covered with chicken mesh and 22 SWG aluminum cladding. Tank should be installed on MS stand of proper height & its load baring. 1 Nos
Heat exchanger cage/Coil type SS304 having surface area should not less then 1.2 Sq.mtr. With SS make up tank. 1 Nos. Inter-connected G.I. B class system piping with GI fittings, insulated with 50 mm glasswool/rockwool insulation covered with chicken mesh & 26SWG aluminum cladding to connect the collectors with hot water storage tank. 1 Lot.
Ball Valve for Inlet & outlet. - 2 Nos. Ball Valve for makeup tank - 1 Nos NRV for Inlet - 1 Nos. NRV for makeup tank. - 1 Nos Dial Type Temprature gauge - 1 Nos
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
100 mm. dia. RCC Pipes
150 mm. dia. RCC Pipes
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
100 mm dia. R.C.C. pipe
150 mm dia. R.C.C. pipe
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
150 x 100 mm size P type
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)
Inside size 90x80 cm and 45 cm deep including RCC cover with frame 450x600 mm internal dimensions.
Extra for depth for manholes
Size 120x90 cm metre 4473
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design:
With 20x20 mm square bar
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
up to 1.50 m depth
Pipes 80 mm to 300 mm diameter
Pipes 300 mm to 600 mm diameter
1.50 m to 3.00 m depth
Pipes 80 mm to 300 mm diameter
Pipes 300 mm to 600 mm diameter
3.00 m to 4.50 m depth
Pipes 300 mm to 600 mm diameter
Open timbering in foundation trenches including strutting and shoring complete (measurements to be taken of the face area timbered.)
Depth not exceeding 1.5 M.
Depth exceeding 1.5 M. but not exceeding 3 M.
Depth exceeding 3.0 M
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.
150 mm. dia. RCC Pipes
250 mm. dia. RCC Pipes
300 mm. dia. RCC Pipes
450 mm. dia. RCC Pipes
500 mm. dia. RCC Pipes
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm
space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29m
With Sewer bricks conforming IS : 4885
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :
With Sewer bricks conforming IS : 4885
Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m :
With Sewer bricks conforming IS : 4885
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Constructing brick masonry INSPECTION chamber 60x60x90 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as per design. With FPS bricks
Providing and laying double flanged (Screwed/Welded) centrifugally (Spun) Ductile iron pipes of class K-9 conforming to IS 8329
100mm dia Ductile iron double flanged
Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket :
100 mm dia pipes
Providing and placing in position C.I. sluice valves category “A” (with cap) complete:
100 mm diameter
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
40 mm nominal outer dia pipes
50 mm nominal outer dia pipes
65 mm nominal outer dia pipes
80 mm nominal outer dia pipes
Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end):
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
Providing and placing in position C.I. double acting air valve of approved make.
Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :
Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Domestic pump Hydro-Pneumatic Booster System Parallel Pumping System Numbers of Pump in System: 3 Pump Version: Cast Iron & S.S AISI 304 Seal Material: Carbon/SiC/SS316/EPDM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Mounting: IEC Enclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE1 Motor System Components Accessories: Included Header Flange Rating: PN 16 Pump Controller: Single VFD with HMI & PLC HPN Pressure Tank: 200 litre
Flow Rate- 525 lpm
2 Working + 1 Stand By
Flushing pump Hydro-Pneumatic Booster System Parallel Pumping System Numbers of Pump in System: 3 Pump Version: Cast Iron & S.S AISI 304 Seal Material: Carbon/SiC/SS316/EPDM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Mounting: IEC Enclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE1 Motor System Components Accessories: Included Header Flange Rating: PN 16 Pump Controller: Single VFD with HMI & PLC HPN Pressure Tank: 200 litre
Flow Rate- 300 lpm
2 Working + 1 Stand By
IRRIGATION PUMP
Supplying & installation of approved make required capacity 3 phase, 50 Hz, 415V, centrifugal mono-block pump, with starter i/c single phase preventer, connections, base channel foundation etc. as required as per specifications but excluding pipe and connection cable.
7.5 HP head metre 24-37, discharge LPM 780-320
Pump Room for Sump Pump
1 Phase open well submersible pump
Supplying &installation of approved make required capacity single phase, 50 Hz, 230V, open well submersible pump, with control panel starter with dry run protection, connections, etc. as required as per specifications but excluding pipe and connection cable.
2.0 HP head metre 14-24, discharge LPM 342-138
Domestic & Flushing Pump Panel
Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.
Same as above item but following mountings.
1 Nos. 125 Amps. 4P MCCB (25 KA)
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-125 Amp. Ammeter (digital type) with inbuilt ASS
200 Amps. TP&N aluminium bus bars
6 Nos. 40 Amps. TPN MCCB (15 KA) - To Pumps
6 Nos. 40 Amps. TPN MCCB (15 KA) - SPARE
Constructing RCC precast perforated RCC. slab covered Drain with 150mm thick RCC 1.1.5.3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size) wall including earth excavation, 75mm thick bed concrete 1:4:8 (1 cement : 4 fine sand : 8 graded stone aggregate 40mm nominal size) and 100mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:
Drain 300 wide average. Depth 500cm with R.C.C. Slab
Drain 450 wide average. Depth 750cm with R.C.C. Slab
Drain 600 wide average. Depth 1200 cm with R.C.C. Slab
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level.
All types of soil
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level.
All types of soil
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
200 mm nominal size dia having minimum wall thickness 5.4 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
150 mm nominal size dia having minimum wall thickness 5.0 mm
Providing and fixing in 200X150 ERW Pipe Reducer including fittings complete.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of:
200mm nominal size dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I).
Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing 80 dia G.I. column pipes complete with G.I. fittings including trenching and refilling etc.
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
80 mm dia nominal bore
Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end):
80 mm nominal bore
Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) :
80 mm nominal bore
Submersible Pump include the rate of electrical control panels complete with all accessories &controls, all Electrical/Mechanical items as required to operate the system automatic/manual.
c) Level Controller with sufficient nos. of low / high level alarms, contacts with electrodes and control wiring for the automatic operation of water supply pumps, Submersible Sump Pumps, to achieve the functional requirement shall be provided. Control wiring between these pumps and water tanks shall be provided.Domestic water pumps must start at low water level in under ground domestic water tank & stop at high level in that water tank. Dry running protection shall be provided for all the pumps.Sequencing shall be provided for each set of pumps.
Supplying & Installation of (400 lpm and 75 mtr head) submersible starter and cable etc of approved make, and all accessories complete as per requirement of site.
SEWAGE TREATMENT PLANT :
Design ,Supplying, installing, testing & commissioning of electro mechanical work of Sewage Treatment Plant of 250KLD based on MBR technology excluding any civil work (excavation, back filling & disposal of surplus earth Civil construction work) for the following duty: Nature of Sewage - Domestic Sewage. Reuse of Treated Water- For Flushing/Iriigation purpose
The STP shall be designed based on the following inlet parameters:
Daily average flow : 250KLD
S. Solids : 350 Mg/l
COD : 400 - 500 mg/L
Oil & Grease : Approx 20 mg/L
Effluent discharge standard after treatment :-
BOD5 : < 5 mg/l
S. Solids : < 1 mg/l
COD : < 30 mg/l
Color : Color Less
Oil & Grease : < 1 mg/l
Sewage treatment plant includes the following tanks and plant room with foundations for pumps and equipments in civil construction:
a Screen chamber with OIL &GREASE trap
b Equalisation Tank
c STP Treated Water Tank
e Aereation tank
g Sludge holding tank
B Electro-Mechenical Equipment-STP(MBR)
Supplying, installing, testing & commissioning 1 nos. S.S. Coarse 12-15mm hole size and 1 nos Fine screen of size 8-10 mm having provision for lifting arrangement etc. complete as required.
Size : 1000mm X 800mm
Purpose: For separation of large solids
Supplying, installing, testing & commissioning level switch and controler for automatic operation of pumps at high and low level with alarm and indication of tanks.
Type: Float type
Supply, installation, testing & commissioning of non clogging type Sewage transfer pumps having CI casing & SS impeller complete with delivery header and all accessories, motor of required capacity. NRV of required size; pressure gauge on delivery line with isolation cock, level controller to control the level for provision to control the level of sump automaticly. Pumps shall have following duty:2No.(1W+1S)
Submersible Sewage Transfer Pump
Flow Rate : 12.5 M3/hr
Head : 10-12 mtr
Solid handling : 35MM
One Set consists : 2 Pumps (1W+1S)
Purpose: For sewage transfer from Equilization to Anoxic Tank
Sludge Recirculation/Transfer pump
Flow Rate : 2 M3/hr
Type : Monoblock type
Solid handling : 12 MM
One Set consists : 2 Pumps (1W+1S)
Plant room sump pump
Flow Rate : 18 M3/hr
Type : submersible type
Solid handling : 20 MM
One Set consists : 2 Pumps (1W+1S)
Supply, installation, testing & commissioning of non clogging MBR permeate pump having CI casing & SS impeller, SS shaft complete with and foundation bolts all accessories, motor of required capacity. NRV of required size; pressure gauge on delivery line with isolation cock, level controller to control the level of sump automatically. Pumps shall have following duty:
Flow Rate : 18 M3/hr
1 Set : 2 Pumps (1W+1S)
Purpose: For suction of clear water from MBR tank & transfer it to trated water tank.
Air diffusion system shall include the following:
2 Nos. twin type rotary air blowers (1W + 1S) for working blowers, capable of delivering 250 M3/hr with free air at 0.5 kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. Including vibration pad and foundation bolts work.(1W+1S)=1Set
Purpose: For air supply to areation, Equilization & Sludge Holding tank.
2 Nos. twin type rotary air blowers (1W + 1S) capable of delivering 200 M3/hr with free air at 0.4 kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. Including foundation and foundation bolts work.(1W+1S)=1Set
Purpose: For air supply to MBR Module.
Non clog, Self Cleaning type air dispersion system including Air dispersion grid capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per / meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from plat form at the top.
Coarse bubble diffuser
Fine bubble diffuser
Purpose : Air dispersion system shall be provided for transfer air in equalisation tank, aeration tank and Sludge Holding Tank.
Providing and fixing all piping (as described below) including all fittings, valve, support for making the system complete.
SS 304 : Submerged air piping
MS Epoxy : Interconnecting pipe line after delivery header of pump/ filter
MS Epoxy : Air piping & pumped sewage riser (non-submerged)
UPVC: Tank overflow and and drain line with interconnecting pipe line.
Supply, installation, testing and commissioning of MBR Module 0.04-0.08 micron pore size fitted in SS skid with hollow fiber/Flat Sheet to be installed in MBR reactor alongwith suitable sludge removal arrangement with suitable lifting arrangement.
No of module: As per manufacturer design for suitable flow 300 kld.
Purpose: For physical seperation of sludge and liquid
Supply, installation, testing and commissioning of CIP System for MBR Module with suitable capacity consisting the following items:
1000 ltr HDPE Tank
CIP Pump capacity & head: flow-10cum/hr. at 20 M head, MOC: SS 304
Supply, installation, testing & commissioning of submersible mixture for anoxic tank with all acessories and motor of required capacity, suitable for 415± 10% volts, 3phase 50Hz cycle AC supply.
Supply, installation, testing and commissioning of screw Filter press for sludge dewatering.
Type : autoOperatio
capacity: 05cum/hr@ 1% sludge consistency
Moter Power: 018KW
Supply, installation, testing and commissioning of sludge Feed Pumps horizontal monobloc type Complete with all fittings & accessories. 2Nos. (1W+1S)
Capacity : 1 M3/H
Purpose: For feed of sludge to screw filter press
Supplying, installing, testing and commissioning of ozonator capacity of 20 gms per hr with SS316 venturi complete in all respect .
Supply, installation, testing & commissioning of non clogging treated water transfer pump having CI casing & SS impeller, ss shaft complete with and foundation bolts all accessories, motor of required capacity. NRV of required size; pressure gauge on delivery line with isolation cock, level controller to control the level of sump automatically. Pumps shall have following duty:
Flow Rate : 18 M3/hr
1 Set : 2 Pumps (1W+1S)
Purpose: For transfer of STP treated water.
INSTRUMENTS WORKS
Suppy, installation, testing & commissioning of electro-mangnetic type flow meter at inlet & outlet.
Providing & fixing online pH meter.
C ELECTRICAL INSTALLATION & AUTOMATION FOR SEWAGE TREATMENT PLANT
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and /or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates shall inclusive of cables, cable trays, earthing (in accordance to specification) with earthing from panel to each motor / equipment.
Microprocessor based PLC Control panel comprising of necessary processors, input/output, (I/O) modules, communication Interface modules and Human-Machine Interface (HMI) required performing the desired functions. The PLC System shall be expandable, OPC compatible and shall be Modular in construction, so as to capable of future expansion without hardware modifications. PLC's shall use standard known protocols and structure for communication outside the system. In case of system failure or power supply failure the outputs shall attain a predetermined fail safe condition (this shall normally be "off"). The PLC used shall have a proven record in the type of application concerned and in the prevailing environmental conditions. PLC shall be of an approved type from a major International Manufacturer. PLC Control Panel shall be provided/operate with all Automation required like Solenoid valve / Pneumatic Valve, instruments like Pressure gauge, Pressure switch / level switch, compressor of required capacity including all fitting & accessories and other required accessories. As per Technical specification etc. to operate the complete Sewage Treatment Plant automatically. The entire STP shall be designed in a way to facilitate complete Automatic mode of control via PLC based system.
100 amps TPN MCCB with the following accessories: a. 0-500 volts 96 x 96 mm square voltmeter with selector switch shall be protected by 2 amps TP MCB. ---1 Set b. 0-100 amps 96 x 96 mm square ammeter with selector switch and 150/5 amps 15 VA burden CL:1 CTs. ----1 Set c. Phase indicating lamps shall be protected by 2 amp SP MCB--- 3 Sets
Bus Bar: 300 amps TPN (25 KA) aluminium bus bar with heat shrinkable insulation sleeves
Outgoings: Suitable rating MCCB, DOL starter & Relay upto 10 HP motor and star delta starter for more than 10 HP motor for each motor. panel shall contain auto / manual selector swtich and indicating / pushbutton lamps with ON / OFF / TRIP indicator of motor.
l. Spare MCB’s of following capacities: i. 63 amps TPN MCB’s 2 Nos ii 32 amps TPN MCB’s 2 Nos
MCC –1 for STP as described above
Note: All MCCB's to be suitable for motor duty and shall be of 25 KA breaking capacity. Provision shall be made for providing potential free contacts to all pumps starters for connection to building automation system. All motor starter shall be provided with Automatic level controller. Overflow alarm must be provided at the plant room
Supply and installation of ladder type/perforated type cable trays of the suitable sizes fabricated out of perforated hot dip galvanised MS sheets of minimum 2 mm thick. The cable tray shall be complete including cost of supporting arrangements etc as per drawings/site condition and as required.
Supply, installation, testing & commissioning of G.I. Strip/G.I. wire clamped to existing cable tray, wall for system/equipment earthing complete as required including interconnection etc.
EFFLUENT TREATMENT SYSTEM :
Contractor shall ensure submission of detail civil GA,P & I diagrams, schematic diagrams, for below mentioned component & additional commenent if so required for the complete working of the ETP.Design (Civil, Mechanical, Electrical, Instrumentation etc.)for, supply installation testing & commissioning of Effluent treatment Plant for the following duty.
Daily average flow - 50 m3/day
BOD5 - 250 - 600mg/l
S.Solid - 200 - 650mg/l
Oil & Grease - 50-140mg/l
Water discharge after treatment
S.Solid : <150mg/l
Oil & Grease : <5mg/l
Effluent treatment Plant consist of following civil tanks as per requirement made of RCC construction:
Bar screen chamber and oil & grease trap
Equalisation tank
Filter feed tank
Treated water tank
ELECTRO MECHANICAL WORK:
Construction of the following tanks and chambers in 4-5mm thick MS sheets with two coats of epoxy paint inside the tanks with enamel paint at outer surface followed redoxide primer. It also include platform, staircase handrails, puddle flanges, with enamel paint.
size: as reuired
Floculation tank/Reaction tank
size: as required
size: as required
Supply, installation, testing and commissioning of PVC Tube Deck settling media to be installed in Primary tank (Clarifier) .
PVC Tube Deck Media 750 mm- COOLDECK/ SDM/ MM Aqua
Supply, installation, testing & commissioning of 2 Nos SS perforated basket bar screen of suitable size with suitable lifting arragement.
Providing & fixing all piping (as described below) with isolation control valves, nrvs for making system complete.
UPVC : Submerged Air Piping
MS Epoxy : Air Piping non submerged
PVC Piping : Pumped effluent & tank overflow pipe line
UPVC : Interconnecting pipe line after delivery header of pump/filter
GI (Class C) : for all other water piping.
Providing and fixing all instrumentation pressure guage, level controller sensers rotameters for air and water for making system comlete.
Supply, installation, testing & commissioning of non clogging type pumps having CI Casing & Bronze Impeller complete with all accessaries, motor of required capacity. Pressure gauge on delivery line with isolation cock , level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty.
Submersible Effluent Discharge Pump ,
Flow Rate(each) - 2.5 Kl/Hr
Solid Handelling 30-40mm
2NOS. (1 Working +1stb)
Sludge disposal monoblok pump
Flow Rate(each) -1 Kl/Hr
Solid Handelling 10mm
1NOS. (1 Working )
Treated effluent transfer monoblok pump
Flow Rate(each) -3 Kl/Hr
Solid Handelling 10mm
1NOS. (1 Working )
Supply, installation, testing & commissioning of dosing system lime/alum/Poly/Hypo comprising of 100 ltrs HDPE/FRP tank with 0-10 lph Electronic Metering Pump.
Supplying, installing, testing and commissioning of SS 304 blade type agitator mixer with speed control gear box motor .
Supplying, installing, testing and commissioning of belt tye Oil Skimmer in oil & grease trap to remove the same with oil collection tray.
Supply installation testing and commissioning of Sludge Holding tank
size: as required.
Air diffusion system shall include the following:
Twin Lobe Rotary Air Blowers for aeration in, Equilization Tank, Sludge Holding Tank (2nos. , 01 Working & 01 Standby) capable of delivering 50 m3/hr of free air at 0.35kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply.
Air piping shall comprise of pipes droppers/laterals with MS (Epoxy Coated) Header complete with all fitting such as tees, crosses, plugs, sockets, Elbows, reducer,supporters & clamps, Puddle flange etc cutting chases and making good.Contractor to submit detailed P& I indicating there propasal
Non clog type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per/meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from plat form at the top. (Imported Fine Bubble Membrane diffusers I and Coarse diffusers for Equilization Tank, Sludge Holding Tank).
Fine Bubble Diffuser (EPDM) 63X600mm- Proflex/ MM Aqua
Coarse Bubble Diffuser (EPDM) 06"- Proflex/ MM Aqua
Air dispersion system shall be provided for Equilization tank, flash mixture and flocculation Tank
Supply, installation, testing & commissioning of horizontal/ vertical centrifugal filter feed water pumps CI Casing & Bronze Impeller along with motor for the pump. Pressure guage with isolation cock, Isolation valve, NRVon delivery line. Isolation valve, strainer (with by pass) at suction. Mechanical seal, suitable vibration elimination pad of approved designed, drain pipe with valve (25mm dia). The pump shall be suitable for 415+10% volts, 3 phase AC Supply.
Capacity : 3KL/Hr
Supplying, installing, testing and commissioning of MSEP (IS:2829) vessel filter. Filter shall be suitable for working pressure of 5.0 kg / cm2 and shall include media, standard fittings like pressure gauges, sampling cock, rinse drain, vacuum breaker, 1no water flow meter at outlet complete (flow meter shall be of approved by department of weights & measures). Including frontal piping and multi port valves.
Mulitgrade Pressure Sand Filter/ Vessel
Filtration velocity : 18 m3/hr/m2
Filter Media : Fine and coarse sand, pebels and gravels
Valve dia : 40 mm
Activated Carbon Filter/ vessel
Filtration velocity : 20 m3/hr/m2
Filter Media : Activated carbon, fine and coarse sand, pebels and gravels
Valve dia : 40mm
Supplying, installation, testing & commissioning of 02 No. (1W+1S) Screw Type sludge feed Pumps. Flow:1cum/hr, Head-35mtr.
Supplying, installing, testing and commissioning of Filter Press of suitable size for the dewatering of sludge generated per day.
Mode of operations: Hydraulic operational, Rachet System With Sludge Tray
Model: 12" x 12" x 12 Plate (hydraulic Operated)
Cake Holding: 96 Ltrs
MOS: MS + PP (Poly Propylene)
Supplying, installing, testing and commissioning of Digital pH Meters With Sensor
Aster -Digital ph Meter- - 01 Nos
Supplying, installing, testing and commissioning of ozonator capacity of 10 gms per hr with SS316 venturi complete in all respect .
Electric control panel for the safe and control operation of all the equipements as mentioned above with all the required contactor, relays complete with voltmeter, ammeter, energy meter with required MCCBs and MCBs.
WATER TREATMENT PLANT
Design, Supplying, Installing, Testing & Commissioning of Water Treatment Plant capacity 550 LPM excluding excavation, back filling & disposal of surplus earth /Civil construction work) for the following duty:
Source of Water - Bore well /MCG Supply
Supply, Installation, testing and commissioning of Horrizontal/vertical, inline multistage centrifugal pumping set with CI Casing and SS 304 impellers with stainless steel SS304 shaft as per IEC standards and GJL 250 cast iron suction and discharge casing connected to TEFC ventilated induction bottom of motor of 2 Pole, 2900RPM, suitable for 415V +/- 10% 3 phase, 50Hz AC Supply.
Filter Feed Pump
Capacity /Flow rate : 33 CUMPH each
Pumping Head : 30 Mts
Location: Basement (Pump room of Filter Feed Water Tank)
Item as Described above
1 Set = 2 Nos. Pump (1 Working+1 Standby)
Supply, Installation, testing and commissioning of vertical self supporting filter vessel fabricated from MSEP, pressure gauges at inlet & outlet with Multiport Valve , sampler cock, air vent with With UPVC Piping along with distribution System and all accessories, with initial charge of filter media
Sand Media Pressure Filter
Flow rate - 33CUMPH
Diameter : 1500 mm
Height : 1800 mm
Filter Media : Multigrade River Pebble and Anthracite
Filtration rate : 15000 L / h / sqm.
Working Pressure : 3.5 Kg/Sq.cm.
Item as Described above
Activated Carbon Filter
Flow rate - 5.4CUMPH
Diameter : 1500 mm
Height : 1800 mm
Filtration rate : 15000 L / h / sqm.
Filter Media : Activated carbon granules
Working Pressure : 3.5 Kg/Sq.cm.
Item as Described above
Supply, Installation, testing and commissioning of vertical self supporting softner filter vessel fabricated from MSEP, with rubber lining inside of 4mm, pressure gauges at inlet & outlet with Multiport Valve , sampler cock, air vent with MSE frontal Piping along with distribution System and all accessories, with initial charge of filter media
Softner vessel Filter
Flow rate - 33CUMPH
Diameter : 1800 mm
Height : 1800 mm
Filter Media : Resin 2160 LTR. Ion Exchange
Incomming hardness: 300ppm
Outlet hardness: >50m
OBR: 400cum (12 hr operation)
Operating time: 12hr.
Filtration rate : 15000 L / h / sqm.
Working Pressure : 3.5 Kg/Sq.cm.
Brine tank: PVC 1000ltr
Agitator:1hp blade type SS304 shaft
Item as Described above
Supply, Installing, testing and commissioning of chlorine dosing system (for domestic water treatment plant) consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing pump having variable flowrate of 0-6 lph @3kg/sqcm. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary polypropylene piping, valves,
(Hydropneumatic Pumping System With Variable Frequency Drive)
Supply, Installation, Testing and Commissioning of compact packaged type skid mounted, self contained variable frequency drive hydropneumatic system complete as per the technical specification complete as required:-
(i) In- line vertical multistage centrifugal water pump set (for clear water) with SS-304 casing, SS-304 impeller with SS-316 shaft ,CI base with coating complete directly coupled with TEFC induction motor of class "F" insulation & efficiency class IE-3, 2900rpm, suitable for opertion on 415 Volts ±10%, 3 phase, 50 Hz A.C. supply. The entire system shall be mounted on a common base frame i/c common suction and common delivery of G.I heavy class pipe headers with flanges, interconnecting piping with all required Conrol Valves, Non-return valves, pressure guage with isolation cock etc. complete as required.
(ii) Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 3 times the vessel operating pressure and prototype cycle tested for 80,000 cycles with charging connections to dischage pipe line with necessary flanges, gaskets, isolating valve, nuts/ bolts etc. with suitable foundation boits etc complete as required.
(iii) Microprocessor based multi pump contoller/panel with graphical display and variable frequency drive (VFD) mounted inside a panel complete with pressure sensor transmitter. The graphical display capable to show number of pumps running & also communicate with other controllers following with open protocol through RS485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. The panel should also have provision for manual / automatic alternate (cyclic) operation of pumps, ON/OFF switch complete as required.
(v) Necessary foundationing bolts, vibration elimination pads etc complete as required.
Domestic Water Supply Pumps
Duty of each pump suitable for:- No. of Pumps : 2 nos. (1 W + 1 S) Capacity : 33 m3/hr of Each Pump Head : 60 Meters Air Vessel : 100 Ltr tank Note:-1 set consists of 2 nos. of pumps (1 Working + 1Standby)
Drainage Sump Pump for Plant room & Basement drainage
Supply, installation, testing and commissioning compact submersible sump pumps of suitable rating, with non-clog free flow open impeller, solid handling capacity at least 20mm suitable for operation on 415 volts +10% , 3 Phase, 50Hz, A.C supply, speed 2900 RPM including guide wire for lifting & lowering of pump, G.I. galvanized lifting chain, complete with MSEP Header with butterfly valves, nrvs, etc to make system complete.
Electrical switch panel with DOL starter having all necessary accessories & safety devices of standard specifications. Automatic built-up water level controller with necessary length of cable upto control panel.
No. of Pumps/set : 2nos. (1 W + 1 S)
Discharge - 600 LPM Each
Head - 15 Meters
Supply, fixing, testing and commissioning of MSEP/UPVC Piping Complete in Plant room Along With Pipe and Valve Stainers Connect with the tank and Drop in treated Water Tank Complete .
Design, fabrication, assembling, wiring, Supply Installation & Commissioning , installation, testing and commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 1 No. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz Supply system. Lifting hooks shall also be provided in case of large panels.
Motor Control Centre
40 amps TPN MCCB with the following accessories:
h. All MPCB, Contactor,Overload Relay Shall be L&T /Schinder/ABB
Supply Installation & Commissioning testing of Cables , Conector, Cable Trays, to make Electrical Installation Complete.
Type - 2-4 Core Copper
Capacity - As per the control panel and machines to connected.
Size of cable - 1sqmm-4sqmm
Qty - As required
Type - Slotted GI
Size - 2" x 4" X6" or as required.
c) Cable Tray Support
Quantity - As per site requirment of approved quality.
Supply Installation & Commissioning testing of Level Controler to switch on the pumps( raw water pump, domestic water supply pump etc) when the level of water in the supply water tank is low and to cut off the pump when the level in the receiving tank is high and switch off the pumpwhen the level of water in supply water tank is low.
To indicate 5 levels of water in all tanks through a control panel with LEDs
To start the pums in a cyclic order.
The system shall be complete to ensure automatic operation of umps in accordance to water level in respective tanks.
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
With 20x20mm square bar
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
M.D. -10- Circular shape 500mm internal diameter
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
Drilling of 300mm dia bore hole manually.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
150 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
(a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
900 lpm at 35 m Head
450 lpm at 35 m Head
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Air Release Valve, Gunmetal, having rubber ball with 1” (25mm) BSP Male threaded inlet
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Fireman Axe-made of carbon steel with rubber insulated handle tested to 20,000 Volts as per IS:926
Fire shaft door fabricated out of M.S. sheet and frame, door size of 1200 (W) x 2100 (h) with 4 mm thick glass, suitable Rubber beading and Locking arrangement and complete door shall be powder coated with red color powder coating
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2 way-100 mm dia M.S. Pipe
4 way - 150 mm dia M.S. Pipe
Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below:
Co2 type Fire Extinguisher 4.5 Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and wheel type valve with initial Charge as per IS: 15683:2018 specification, bearing ISI Mark & EIL approved.
Providing and fixing of ABC Power type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket. Conforming to IS: 15683 finished externally with red enamel paint fixed to wall with brackets complete with internal charge.
Providing and fixing of ABC Power type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket. Conforming to IS: 15683 finished externally with red enamel paint fixed to wall with brackets complete with internal charge.
Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge.
Supply installation, testing and commissioning of approved make DOL starter 7.5 hp, 3 phase, 50 Hz, 415V, i/c single phase preventer, incoming MCB 32A 4P, 10KA , in outdoor type enclosure, connections, as required as per specifications.
Copper Power Cables, Solid Copper Conductor upto 6 sq. mm & Balance Stranded Copper, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Unarmoured/Armoured (Glavanised wire for cables up to 10x1.5 sq. mm, 8x2.5 sq. mm, 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm & balance all galvanised steel strip), Extruded PVC Type ST2 Outer Sheathed, 650/1100 V Grade as per IS 7098
4 Core X 10 sqmm. Aluminium Armoured
Supplying and making end termination with brass double compression gland and aluminium lugs for following size of XLPE insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.
4 Core X 10 sqmm. Aluminium Armoured
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
150 mm width x 50mm depth x 1.6 mm thickness.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing flow switch in following sizes M.S.pipe including connection etc as required.
Supplying and fixing Air Vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
50 mm dia butterfly valve of PN 1.6 rating
25 mm dia Gun metal valves
25mm Sight Glass
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Upright Sprinkler
Horizontal side wall sprinkler
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
(a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
(b)Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
(d)Suitable cement concrete foundation duly plastered
2280 lpm at 88 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type,multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
2280 lpm at 88 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 lpm at 88 m Head
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
FRP Hose Box single door (750X600X250)
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
400A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500Amps
Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)
Main Fire Pumps 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets
Jockey Pump 63 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets
DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc
4 Core X 16 sqmm. Aluminium Armoured
4 Core X 10 sqmm. Aluminium Armoured
3.5Core X 50 sqmm. Aluminium Armoured
3.5 Core, X 35 sqmm. Aluminium Armoured
3.5 Corex 300 sqmm. Aluminium Armoured
3.5 Corex 120 sqmm. Aluminium Armoured
Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat shall be not less than 3 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge. It should be complete as per specifications & directions of Engineer-in-charge.
Supplying and making end termination with brass double compression gland and aluminium lugs for following size of XLPE insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.
4 Core X 16 sqmm. Aluminium Armoured
4 Core X 10 sqmm. Aluminium Armoured
3 Core, X 50 sqmm. Aluminium Armoured
3 Core, X 35 sqmm. Aluminium Armoured
3.5 Corex 300 sqmm. Aluminium Armoured
3.5 Corex 120 sqmm. Aluminium Armoured
Supplying , installating, Testing & commissioning of XLPE insulated & PVC sheathed 1.1 KV grade armoured Copper control cables for various equipment through walls / ceilings with appropriate clamps / fixing arrangements and complete with termination as per manufacturer's specifications & as directed by Engineer-in-charge.
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in surface steel conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable including painting as required.
Wiring for twin control light point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in surface steel conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable including painting etc as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface steel conduit including painting etc as required. 3 X 4 sq. mm in 25mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface steel conduit including painting etc as required. 6 X 4 sq. mm in 32mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface steel conduit including painting etc as required.
3 X 1.5 sq. mm in 20mm conduit
3 X 2.5 sq. mm in 20mm conduit
3 X 6 sq. mm in 25mm conduit
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in surface PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required.
Wiring for twin control light point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in surface PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface PVC conduit etc as required. 3 X 4 sq. mm in 25mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface PVC conduit etc as required. 6 X 4 sq. mm in 32mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface PVC conduit etc as required.
3 X 1.5 sq. mm in 20mm conduit
3 X 2.5 sq. mm in 20mm conduit
Supplying and drawing following pair 0.5 mm FR PVC insulated copper conductor, unarmored telephone cable in the existing surface/ concealed steel/ PVC conduit as required.
Supplying and drawing following grade co-axial TV cable PVC insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ concealed steel/ PVC conduit as required. RG-6 grade
Supplying and fixing of following sizes steel conduit along with accessories in surface including painting complete as required.
Supplying and fixing of following sizes pvc conduit along with accessories in surface complete as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
TV antenna socket outlet
Fan regulator (two module size) electronic stepped type moving all rounds
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
75mmX75mm (1/2 Module)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Ceiling rose, 3 pin, 5 A
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in surface PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required.
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in surface PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 36 watt, size 600 x 600mm
Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 12 Watt
Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 15/16 Watt
Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 18/20 Watt
Supply of IP40 Led fixture 20 W+/- 1W with Surface Mounted 4 Feet with Polycarbonate diffuser with aluminium housing having minimum system lumen efficacy of 110 lm/W with minimum system lumen output 2200 lumens with P.F.>0.95 with THD<10% ,CCT 5700K, CRI 80,Surge Protection 3 Kv .The LEDs with minimum life of 75000 burning hours. The Input voltage range shall be 150V to 270V.
Supply of IP20 Led fixture 2FT 10 W+/- 1W with Surface Mounted 4 Feet with aluminium housing and Polycarbonate diffuser,minimum system efficacy of 100lm/W with P.F.>0.90 with THD<20% ,CCT6500 K,CRI 80,Surge Protection 2 Kv, IP20.The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 270V.
Supply of IP65 Bulkhead led fixture 10 W +/- 1 W Wall Mounted with minimum system lumen efficacy of 100 lm/W with Pressure Die Cast Aluminum housing, Polycarbonate Opal Diffuser and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 5000K- 5700 K only with CRI of minimum 80.The Input voltage range shall be 140V to 280V with 2.5 kV Surge Protection.
Supply, Installation testing and commissioning of red colour aviation light LED integral type comprising of aluminium powder coated housing with polycarbonate enclosure IP 65 on existing pipe/support including connection, testing etc. as required. Guarantee as per tender agreement condition.
i 20 watt (300 LED)
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, earthing etc. complete as required. 1200 mm sweep
Supplying and fixing of wall/ cabin fan of 400mm sweep including connection etc. as required.
Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in lovers in existing opening in wall including earthing etc. complete as required.
ii 300 mm sweep
Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as required.
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a. 6 amps to 32 amps
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator)
iii 8 way, Double door
iv 12 way, Double door
Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as required. (But without MCB/ RCCB/ Isolator)
i 4 way (4 + 12), Double door
ii 6 way (4 + 18), Double door
iii 8 way (4 + 24), Double door
iv 12 way (4 + 36), Double door
Supplying and fixing on surface/ recess prewired vertical type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete with loose wire box, terminal blocks, 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland plate, loose wire box, superior make terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as required. (But without MCB/ RCCB/ Isolator) (Note: Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)
i 4 way (4 + 12), Double door
6 way (4 + 18), Double door
ii 8 way (4 + 24), Double door
iii 12 way (4 + 36), Double door
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 2 pole and earth, 240 volts, industrial type, socket outlet, enclosed metal plug top along with SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 20 Amp with “C” curve MCB
Supplying and fixing TPN and earth, 440 volts, industrial type, socket outlet, enclosed metal plug top along with MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 32 Amp with “C” curve TP MCB
Supplying and erection DANGER BOARD made MS sheet duly painted and maked as per IE rules and specification.
Supplying and erection DANGER BOARD made MS sheet duly painted and maked as per IE rules and specification.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.
For 4 way, Double door TPN MCBDB
For 6 way, Double door TPN MCBDB
For 8 way, Double door TPN MCBDB
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate having 4 nos holes for fixing etc. complete as required.
Making jointing of copper tape (with another copper tape, base of the finial or any other metallic object) by reverting, sweating and soldering/ nut bolting of as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Supplying, installing suspension ON CEILING, testing and commissioning of following capacity Air Insulated COMPACT TYPE BUS TRUNKING for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required:
400 amps 30KA SC for 1 sec
630 amps 50KA SC for 1 sec
800 amps 50KA SC for 1 sec
Supplying, installing, testing and commissioning of TPN tap off box of following capacity, made of 1.6mm thick sheet steel enclosure duly painted with powder coating, on existing rising mains with space for TP Disconnector switch/ MCCB (without switch/MCCB), interconnections with copper lead and copper lugs/thimbles, earthing etc. as required:
Supplying, installing, End Feed Unit and connecting to existing general/ Compact Type bus trunking/ Rising mains, of following capacity for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with space provision of Disconnector switch/ MCCB/ ACB (but without Switch/MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required:
400 amps 30KA SC for 1 sec
630 amps 50KA SC for 1 sec
800 amps 50KA SC for 1 sec
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
3 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 35KA
3 pole MCCB, 630A, Adjustable Thermal - Magnetic Release, 50KA
3 pole MCCB, 800A, Adjustable Microprocessor Release, 50KA
Supply and fixing of perforated 2mm thick CRCA sheet steel power coated cable tray of following sizes complete with bend/tee joints, coupling plate & nuts bolts etc. including providing and fixing of M.S. painted hanger etc. as required.
150mm wide 50 mm depth
300mm wide 62.5mm depth
450mm wide 62.5mm depth
600mm wide 75mm depth
900mm wide 75mm depth
Supplying and installing following size powder coated, perforated M.S. cable trays with perforation not more than 17.5% rigidly suspended from the ceiling with M.S. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc complete as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width x 50 mm depth x 2.0 mm thickness
600 mm width X62.5 mm depth X 2.0 mm thickness
900 mm width X62.5 mm depth X 2.0 mm thickness
Supplying and fixing of following sizes powder coated, perforated, M.S. cable trays bends (horizontal) turning at 900 in same plane with perforation not more than 17.5% rigidly jointed with cable tray etc. complete as required.
150 mm width X 50 mm depth X 1.6 mm thick
300 mm width X 50 mm depth X 1.6 mm thick
450 mm width X 50 mm depth X 1.6 mm thick
600 mm width X 62.5 mm depth X 2 mm thick
900 mm width X 62.5 mm depth X 2 mm thick
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Armoured 2 core
3½ Core Armoured
3.5 x 25 sq. mm.
3.5 x 35 sq. mm.
3.5 x 50 sq. mm.
3.5 x 70 sq. mm.
3.5 x 95 sq. mm.
4 Core Armoured
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing following sizes one number power cable of 1.1 KV grade on surface/ existing cable tray as required.
Upto 35 sqmm (with 1 mm thick GI saddle)
Above 35 sqmm and upto 120 sqmm (with clamp made of 25x3mm MS flat)
Above 120 sqmm and upto 185 sqmm (with clamp made of 40x3mm MS flat)
Above 185 sqmm and upto 400 sqmm (with clamp made of 40x3mm MS flat)
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 25 sq. mm (28mm)
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
3½ X 400 sq. mm (82mm)
4 X 10 sq. mm (25mm)
4 X 16 sq. mm (28mm)
Supplying and making outdoor end termination with cast resin compound including aluminum lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor power cable of 1.1 KV grade as required.
3½ X 120 sq. mm
3½ X 150 sq. mm
3½ X 185 sq. mm
3½ X 240 sq. mm
3½ X 300 sq. mm
3½ X 400 sq. mm
Supplying and making straight through joint with heat shrinkable joint kit including aluminium ferrules for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.
3½ X 120 sq. mm
3½ X 150 sq. mm
3½ X 185 sq. mm
3½ X 240 sq. mm
3½ X 300 sq. mm
3½ X 400 sq. mm
Supply , Installation , Engineering ,Testing And Commissioning of following items of complete Passenger / Bed / Service Lift system in multistorey blocks . All items to include providing all materials and it's assembly at site , labour, T&ps, consumales etc. required at " Jind Haryana" as per specification and drawings and directed by Engineer-in-Charge including transit insurance and storage insurance at site till handing over. Supplier shall provide NOC and inspection certificate from the Lift Safty Septt. of Govt. / Statutarry body (Confermingto IS -14665 Specifications)
Car Type - Stainless steel car in hair line finish 1.22 BG, ARD infrared curtain. Door Size - Maximun available in above category of lifts with Ceramic Flooring
Door operation - Automatic centre / Side opening (as requried) fire rated door with V3F drive.
Operator Door protection - Continuas full infrared Door Protection
Other Provisions to be made in each lift :-
1) Combined luminous hall button with digital hall position indicator at all floors.
2) Integral full height car operating panel with luminous braille buttons , digital car position indicator combined with direction arrows, overload warning indicator.
3) Standard Electrical fittings of Phillips, Havell’s, Bajaj, Crompton greaves or equivalent. Lux Level 150
4) Voice Floor Announcement System with background music
5) Battery operated alarm bell and emergency light.
6) Automatic Rescue Device.
7) Fireman's switch at main lobby.
8) All cables fittings of standard make from distribution board provided. Face plate finish - stainless steel in hairline finish 1.22 BG face plate shape – rectangular
9) Control - A.C. variable voltage variable frequency (with close loop) Operation - Independent IBMS Compatable
10) Machine - Gearless placed directly above the hoistway with regenaration.
11) Car panel - Stainless Steel Panels , SS car door, SS landing door (All Stainless Steel are in hair line finish 1.22 BG)
12) Hand Rail - SS hand rail at 900mm all three side.
13) Ventilation Fan / Blower
14) Fireman's switch for eachlift as tire law.
Above to include supply of mandatory spares & tools for free comprihasive maintenance of 12 months from the date of handing over and obtaining clearances from statutory bodies. Any extra steel structure as required at site.
Bed Lift for Academic Building
Capacity - 20 Persons (Load 1360 Kg.) Speed - @ 1.0 mps
Travel (Max.) - Basement to 4th floor, (G+4). Stops - 5 stops, 5 opening
Shaft Size provided - 2750mm wide x 3000 mm deep, pit size provided - 1600mm deep
Capacity - 20 Persons (Load 1360 Kg.) Speed - @ 1.0 mps
Travel (Max.) - Basement to 4th floor, (G+7). Stops - 8 stops, 8 opening
Shaft Size provided - 2750mm wide x 3000 mm deep, pit size provided - 1600mm deep
Passenger Lift for Intern Male & Female Hostel
Capacity - 8 Persons (Load 544 Kg.) Speed - @ 1.0 mps
Travel (Max.) - Basement to 4th floor, (G+3). Stops - 4 stops, 4 opening
Shaft Size provided - 1800 mm wide x 1900 mm deep, pit size provided - 1600mm deep
Passenger Lift for Type D Residance
Capacity - 13 Persons (Load 884 Kg.) Speed - @ 1.0 mps
Travel (Max.) - Basement to 4th floor, (G+3). Stops - 4 stops, 4 opening
Shaft Size provided - 1900 mm wide x 2500 mm deep, pit size provided - 1600mm deep
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
Ten Loop Panel.
Two Loop Panel.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supply, installation, testing & commissioning of follwing type Addressable detectors (EN/UL approved) with detector mounting base and other required accessories. Multi-Sensor combined (Photo + Thermal) detectors
Supply, installation, testing & commissioning of follwing Addressable devices (EN/UL approved) with mounting base and other required accessories. Response indicator
Supply, installation, testing & commissioning of follwing Addressable devices (EN/UL approved) with mounting base and other required accessories. Isolator module (Fault / Loop)
Supplying, installation, testing & commissioning of intelligent aspiration detector for area coverage of minimum 5000 sq. ft. complete as required.
Supply, installation, testing & commissioning of follwing type Addressable detectors (EN/UL approved) with detector mounting base and other required accessories. Multi-Sensor combined (Photo + Thermal) detectors Rate of Rise Thermal (Heat) detectors
Supply, installation, testing & commissioning of follwing Addressable devices (EN/UL approved) with mounting base and other required accessories. Control Module (for access triping off)
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
Supply, installation, testing & commissioning of Analogue Addressable BEAM TYPE FIRE detectors suitable for minimum 30m span with detector mounting base & required accessories.
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.
Supply, installation, testing & commissioning of follwing Addressable devices (EN/UL approved) with mounting base and other required accessories. Pull Station Type Manual Call Points.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
Supply of XLPE insulated 1.5 sq. mm. Armoured 2 core FRLSZH fire alarm cable (RED) Fire Survival Cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor
Supply and fixing PVC conduit ISI marked FRLS along with the accessories in concealed system etc. as required
PVC. conduit 25 mm (HMS)
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supply, installing, testing and commissioning of 1X500W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection
Supply, installing, testing and commissioning of IP based Networkable touch screen paging station for selection of zones, supervision of system status, setting of scheduled broadcasts with the following functions: . Built-in monitoring loudspeaker . Detachable goose-neck microphone . LCD touchscreen display . Audio input
Supplying and Laying of 2 core twin twisted 48/0.2 ATC, Multi strand, over all armoured speaker cable as specified in the Tender Specifications
Supplying and Laying of 2 core twin twisted 48/0.2 ATC, Multi strand, over all armoured speaker cable as specified in the Tender Specifications
Supply , Installtion , Testing and Comissioning of armoured 6 core Singlemode OFC cable for interfloor switches connectivity.
Supply , Installtion , Testing and Comissioning of 6 port loaded LIU with LC adaptor plates , pigtel cables etc complete as required.
Supply , Installtion , Testing and Comissioning of 24 port loaded LIU for with LC adaptor plates , pigtel cables for core switch to access switch connectivity over fiber.
Supply , Installtion , Testing and Comissioning of LC-LC singlemode fiber patch cord for LIU to switch connectivity.
Supply , Installation , Testing and Commissioning of CAT 6 A UTP cable 23 AWG solid copper conductors for Connectivity of Hub room to End Point.
Supply , Installation , Testing and Commissioning of CAT6 information outlet (I/O) for Data, Voice, Camera & Wi-Fi at user end.
Supply , Installation , Testing and Commissioning of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end.
Supply , Installation , Testing and Commissioning of CAT6 patch cord 3 feet for rack side switch to jack panel connectivity.
Supply , Installation , Testing and Commissioning of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity.
Supply , Installation , Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side.
Supply , Installation , Testing and Commissioning of 42 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Each of hardware pkts.
Supply , Installtion , Testing and Comissioning of 15U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Each of hardware pkts.
Supply, Installation, Testing & Commissioning of Core Switch Should have Min 48 Port /1G/10G/40G Gigabit Eathernet + 4x 40G Uplink. Operating Temperature 5C to 40C . with switching capacity of 1.4Tbps, forwarding performance of 1Bpps with 32x 1/10G SFP+ ports plus 4x 40G QSFP+ ports from day 1, dual hot swappable internal power supply, 60K IPv6 routes and 48K IPv6 multicast routes. Should support advance layer 3 (RIPng, OSPF, BGP and MPLS) with 1 year support. Stack Module/40 Gig Optics and all other Cables should be included in Day 1.
Supply, Installation, Testing & Commissioning of POE Acess Switch switch Should have min 48 10/100/1000 Gigabit Eathernet min 4 x1G/10G SFP port.Stacking port .Minimum operating temp. 5c to 40c.Must supprop 10 switch stacking .Must have common crieteria certification EA/NDPP or other Should support min 2GB internal DRAM, 2GB internal Flash memory,32K MAC address, 1K IPv6 Multicast Routes, Should have static Routes from day 1
Supply, Installation, Testing & Commissioning of POE Acess Switch switch Should have min 24 10/100/1000 Gigabit Eathernet min 4 x1G/10G SFP port.Stacking port .Minimum operating temp. 5c to 40c.Must supprop 10 switch stacking .Must have common crieteria certification EA/NDPP or other Should support min 2GB internal DRAM, 2GB internal Flash memory,32K MAC address, 1K IPv6 Multicast Routes, Should have static Routes from day 1
Supply , Installation , Testing and Commissioning of fiber Modules 1G BASE
Supply , Installation , Testing and Commissioning of Stacking Cable
Supply, Installation, Testing & Commissioning of the Microservices based WLAN Architecture. The indoor AP should have radios to support 2.4Ghz and 5 Ghz band in a 4X4:4 Mu-MIMO configuration with support for 802.11 a/b/g/n/ac. The AP should have internal Omni Antennas and should support vBLE and RF optimization. It should also support way finding and asset tracking via bluetooth.Should support Artificial Intelligence platform, WIPS/WIDS to detct Rogue APs and the facility to terminate connevction to the Rogue APs.Plenum rated and support for UL 60950-1 CAN/CSAC22.2 No. 60950-1, FCC Part 15.247, 15.407, 15.107, and 15.109 RSS247 ICES003
Supply, Installation, Testing & Commissioning of The controller should be AI driven on premise or cloud based controller. The controller should be based on Micro Services based Architecture. The solution should support 802.11ac primarily but, should be becakward comaptible to 802.11 a/b/g/n as well and also should have provision to take care of 802.11ax based APs. It should also support way finding and asset tracking via bluetooth.Should support Artificial Intelligence platform, WIPS/WIDS to detct Rogue APs and the facility to terminate connevction to the Rogue APs. The platform should support Guest portal as well and shoul dbe scalable to 200 APs in future. Must be able to provision bulk deployment via templates. Should also have feature to limit the bandwidth based on client, SSID and application. Should have provision to create WxLAN policies or ACLs to create rules as per organizational requirement. Should have provision to extent API to integrate with other systems as well
Supply , Installation , Testing and Commissioning of Internet Web Security solution with minimum of 500 users from day one with 1 years of subscription / support and flexibility to scale up to 5000 users, having 99.9% uptime with each level redundancy, single pane of glass for reporting with minimum 6 months of logs and must be Leaders in Gartner Magic Quadrant in the last 1 consecutive years (2017) and includes following features as per detailed specification: a) Web Security b) Full SSL Inspection c) Next Generation Firewall d) Sandboxing e) Bandwidth Control f) Cloud Applications Visibility g) Mobility
Supply , Installation , Testing and Commissioning of IP Based voice Communication System with 08 Port Voicemail ,08 Port FXS ,08 Port FXO ,3 PRI Trunk lines (30x3Ch) Circuit with CLIP Facility, 907 IP users License ,02 Each IP based Operator Console, 120 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup.
Supply , Installation , Testing and Commissioning of Type -1 IP phone with 1 VoIP accounts, graphical LCD.
Supply , Installation , Testing and Commissioning of Type 2 IP Phone with 2 Voip accounts, 2 Lines , HD Voice,Graphic LCD display with backligh.
Supply , Installation , Testing and Commissioning of LC-LC singlemode fiber patch cord for LIU to switch connectivity.
Supply , Installation , Testing and Commissioning of CAT 6A UTP cable 23 AWG solid copper conductors for Connectivity of Hub room to End Point.
Supply , Installation , Testing and Commissioning of CAT6A information outlet (I/O) for Data, Voice, Camera & Wi-Fi at user end.
Supply , Installation , Testing and Commissioning of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end.
Supply , Installation , Testing and Commissioning of CAT6 patch cord 3 feet for rack side switch to jack panel connectivity.
Supply , Installation , Testing and Commissioning of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity.
Supply , Installation , Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side.
Supply , Installation , Testing and Commissioning of 5 MP Dome Camera , ONVIF profile S & G ,UL , CE , FCC Certified , 1/2.8" CMOS sensor ,3.to 9 mm varifocal , triple stream ,Min Illumination :0.01 Lux @ (F1.2, AGC ON), 0.028 Lux @(F2.0, AGC ON), 0 Lux with IR , Shutter Speed : 1/5 ̴ 1/100,000 s , Video Compression : H.265 ,H.264 , frame rate 30 fps @ 2 MP ,
Supply , Installation , Testing and Commissioning of 5 MP Bullet Camera , ONVIF profile S & G ,UL , CE ,FCC Certified , 1/2.8" CMOS sensor ,3 to 9 mm varifocal , triple stream , Min Illumination :0.05 Lux @ (F1.2, AGC ON), 0 Lux with IR , Shutter Speed : 1/5 ̴ 1/100,000 s , Video Compression : H.265 , H.264 , frame rate 30 fps @ 2 MP ,
Supply, installation, testing and commissioning of 64 Channel NVR upgradable to 128 Channel, H.264 Recording and Playback , Embedded Linux OS, Pre-Installed VMS with licenses,ONVIF profile S & G , Intel Based i7 Processor , 2x4GB, DDR3 RAM , Intel HD Graphics , Throughput Input: 640Mbps / Output: 640Mbps,Decoding Rate Up to 3840 PPS @ D1, 2.5” SATA x 1 (for OS) + 3.5” SATA x 8 ports , e-SATA Port for External Storage Device , RAID 0/1/5/6/10 Support , COM Port RS-232 x1 and RS-485 x 1, USB 3.0 x 2 + USB 2.0 x 3 , Digital Input : TTL-level x 4 , Digital Output : Relay NC/NO x2 (DC24V/1A) , 1 x WAN (10/100/1000 BaseT) , 1 x LAN (10/100/1000 BaseT), 1 x SFP Port (1 Gbps).
Supply , Installation , Testing and Commissioning of 6TB Surviellance Hard Disk.
Supply , Installation , Testing and Commissioning of Full HD 55" LED Professional Display Panel.
Supply , Installation , Testing and Commissioning of 24 port Fabric (SFP) switch with 20 Each of 20 100M/1G SFP Port , 4 Each of GbE RJ45/SFP Combo Port , 4 Each of 1G/10G SFP+ Port ,1 X Console , Switching bandwidth 128 Gbps , 32K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN . Support IEEE 802.3ad LACP . L3 features - static routing , DHCP server.
Supply , Installation , Testing and Commissioning of 24 port L2 Managed switch having port density 24 Nos of 10M/100M/1G RJ45 Port POE /POE+ ports , 2 Nos of GbE RJ45/SFP Combo Port , 1X console port , Available POE power 370 W , 52 Gbps switching bandwidth , 8K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN . Support IEEE 802.3ad LACP . L3 features - static routing , DHCP feature , Device Management system - topology view , floor view , map view , dashboard , traffic monitoring , cable diagnostics.CE,FCC certified.
Supply , Installation , Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 10 Professional 64 Bit or latest.
Supply , Installation , Testing and Commissioning of fiber Modules 1G BASE
Lift Machine Room for College Block
a) 1 no. 100 A four pole MCCB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 100/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 2 no. FP 63 A MCCB 50 KA
b) 1 no. FP 63 A MCCB 50 KA
c) 1 no. DP 32 A MCB 10 KA
UPS Panel for College Block
a) 1 no. 150 A four pole MCCB (25 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 150/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 8 no. FP 63 A MCB 10 KA
b) 2 no. FP 63 A MCB 10 KA
c) 1 no. FP 40 A MCCB 50 KA
a) 1 no. 500 A four pole MCCB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 500/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 9 no. FP 40 A MCB 10 KA
b) 18 no. FP 63 A MCB 10 KA
c) 2 no. FP 40 A MCB 10 KA
a) 1 no. 500 A four pole MCCB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 500/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 9 no. FP 40 A MCB 10 KA
b) 18 no. FP 63 A MCB 10 KA
c) 2 no. FP 40 A MCB 10 KA
Central Mess Panel
a) 1 no. 200 A four pole MCCB (35 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 200/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 2 no. FP 40 A MCB 10 KA
b) 1 no. FP 63 A MCB 10 KA
c) 2 no. FP 63 A MCCB 15 KA
d) 2 no. FP 40 A MCCB 15 KA
Guest House Block Panel
a) 1 no. 100 A four pole MCCB (35 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 100/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 1 no. FP 40 A MCB 10 KA
b) 3 no. FP 63 A MCB 10 KA
c) 1 no. FP 40 A MCB 10 KA
a) 1 no. 200 A four pole ACB (35 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 200/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 3 no. FP 40 A MCB 10 KA
b) 6 no. FP 63 A MCB 10 KA
c) 1 no. FP 40 A MCB 10 KA
a) 1 no. 200 A four pole ACB (35 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 200/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 3 no. FP 40 A MCB 10 KA
b) 6 no. FP 63 A MCB 10 KA
c) 1 no. FP 40 A MCB 10 KA
a) 1 no. 500 A four pole MCCB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 630/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 20 no. DP 40 A MCB 10 KA
b) 5 no. FP 100 A MCB 10 KA
b) 13 no. FP 63 A MCB 10 KA
Jr. & Sr. Resid. Dr. Block Panel
a) 1 no. 800 A four pole MCCB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 800/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 7 no. FP 40 A MCB 10 KA
b) 19 no. FP 63 A MCB 10 KA
c) 9 no. FP 63 A MCB 10 KA
d) 2 no. FP 40 A MCB 10 KA
Type-D Block Panel
a) 1 no. 320 A four pole MCCB (35 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 320/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 8 no. FP 40 A MCB 10 KA
b) 8 no. FP 63 A MCB 10 KA
c) 1 no. DP 32 A MCB 10 KA
d) 2 no. FP 40 A MCB 10 KA
e) 1 no. DP 32 A MCB 10 KA
Sub-Main Panel of Lift Machine Room for Type-D Block
a) 1 no. 100 A four pole MCCB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 100/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 2 no. FP 63 A MCCB 50 KA
b) 1 no. FP 63 A MCCB 50 KA
c) 1 no. DP 32 A MCB 10 KA
Type-E Block Panel
a) 1 no. 630 A four pole MCCB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 630/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 16 no. FP 40 A MCB 10 KA
b) 16 no. FP 63 A MCB 10 KA
c) 1 no. DP 32 A MCB 10 KA
d) 2 no. FP 40 A MCB 10 KA
e) 1 no. DP 32 A MCB 10 KA
Sub-Main Panel of Lift Machine Room for Type-E Block
a) 1 no. 100 A four pole MCCB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 100/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 2 no. FP 63 A MCCB 50 KA
b) 1 no. FP 63 A MCCB 50 KA
c) 1 no. DP 32 A MCB 10 KA
Type-F Block Panel
a) 1 no. 250 A four pole MCCB (35 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 250/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 16 no. FP 63 A MCB 10 KA
b) 1 no. DP 32 A MCB 10 KA
c) 2 no. FP 40 A MCB 10 KA
d) 1 no. DP 32 A MCB 10 KA
Sub-Main Panel of Lift Machine Room for Type-F Block
a) 1 no. 100 A four pole MCCB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 100/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 2 no. FP 63 A MCCB 50 KA
b) 1 no. FP 63 A MCCB 50 KA
c) 1 no. DP 32 A MCB 10 KA
Superintendent & Director's Residences Panels
a) 1 no. 63 A four pole MCCB (25 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 63/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 1 no. FP 40 A MCB 10 KA
b) 1 no. FP 63 A MCB 10 KA
c) 1 no. FP 40 A MCB 10 KA
Outdoor Feeder Panel-01
a) 1 no. 1250 A four pole ACB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 1250/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 1 nos. 32A DP MCB 10KA (Pump Room)
b) 1 nos. 630A FP MCCB 50KA (Type-E)
c) 1 nos. 320A FP MCCB 35KA (Type-D)
c) 1 nos. 250A FP MCCB 35KA (Type-F)
Outdoor Feeder Panel-02
a) 1 no. 800 A four pole ACB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 800/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 1 nos. 200A FP MCCB 25KA (IF)
b) 1 nos. 500A FP MCCB 50KA (GH)
c) 2 nos. 63A FP MCCB 25KA (Sup. & Dir. Resid.)
d) 1 nos. 100A FP MCCB 25KA (Guest House)
Outdoor Feeder Panel-03
a) 1 no. 1250 A four pole ACB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 1250/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 1 nos. 200A FP MCCB 25KA (Central Mess)
b) 1 nos. 63A FP MCCB 25KA (Sport Complex)
c) 1 nos. 800A FP ACB 50KA (Sr. & Jr. Dr. Resid. Hostel)
d) 1 nos. 630A FP MCCB 50KA (NH)
Outdoor Feeder Panel-04
a) 1 no. 800 A four pole ACB (50 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 800/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 1 nos. 200A FP MCCB 25KA (IM)
b) 1 nos. 500A FP MCCB 50KA (BH)
c) 1 nos. 200A FP MCCB 50KA (STP/ETP)
d) 1 nos. 63A FP MCCB 25KA (Play Ground)
Outdoor Feeder Panel-05
a) 1 no. 200 A four pole MCCB (25 KA).
b) 1 no. Digital type single function volt Metre to show 0-500V voltage with phase selector switch.
c) 1 no. Digital type single function aMetre to show amperage with phase selector switch.
d) 3 Nos cts 200/5 ratio.
e) 3 LED Indication Light with toggle switches.
a) 3 nos. 32A DP MCB 10KA
b) 15 nos. 40A FP MCCB 15KA
c) 4 nos. 63A FP MCCB 25KA
UNINTERRUPTED POWER SUPPLY (UPS)
Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, having three phases input three phase output. Online double conversion VFI-SS-111 technology, with sinusoidal wave form, architecture (standalone of distributed parallel up to 8 units), having input characteristics i.e. input voltage (380v, 400v, 415v, 3Ph+N+PE), input frequency (45 -65 Hz), input voltage range (Ph - Ph) : (half load 208v - 467v/full load 312v - 467v), total harmonic distortion of input current < 3% (at full linear load), compatibility with diesel generators configurable for synchronization between the input and output frequencies even for high frequency variations, input power factor > 0.99, having output characteristics i.e. output voltage (380v, 400v, 415v, 3Ph+N (adjustable from front panel), efficiency up to 96%, efficiency in ECO mode up to 98.5%, output frequency (nominal) 50 /60 Hz 0.01% free run (adjustable from front panel), crest factor 3 : 1, total harmonic distortion of output voltage < 2 % (at full linear load), output power factor 0.9, output voltage tolerance ± 1%, built in automatic and maintenance bypass, inbuilt isolation transformer, battery type (VRLA - AGM maintenance)
80 KVA (3 phase input & 3 phase output)
For 30 minute backup, min. 60000 VAH
SITC of BMS Computer System: i7 Processor orHigher, Intel(R) Xeon(R) Processor, 2.93GHz, 4MB Cache with 8 GB RAM, & 1 TB HDD, 10/100 Mbps Ethernet card, USB connection & internal modem, Microsoft(R) Windows(R) 10 OS Professional Enterprise or Higher, Web server software, DVD-ROM Drive (with RAM), 100/1000 Mbps NIC for Network connection and anti virus software with 32" colour graphics monitor as per Tender SpecificatioMR. Accessories included Optical Mouse, Key Pad, Laserjet A4 printer with the above BMS System configuration. Windows LiceMRed software compatible with the BMS platform etc. complete as required.
Application Software
SITC of the following window based graphical software for IBMS system with 1No Client for Operator workstation, 1No Client for Engineer workstation. The Software shall have 3D & HD vector dynamic graphics with Autocad import of plan with Zoom In & Zoom Out facility, Native 64 Bit System , BTL,UL,EN Certified System, BACnet Profile B-AWS (Advanced workstation) as per the BTL Listing, dot net platform, Certified OPC DA Server by OPC Foundation, Web-Based Server software shall permit use of Standard Web-Browsers such as Microsoft Internet Explorer, Netscape Navigator, etc. The Software shall comply to international standards and strive to deliver products that meet security standards such as ISA/IEC 62443, UL2900, ISO/IEC 27001, ISO/IEC62443 and OWASP. Cybersecurity audit trail , 4-eye principle , Seamless integration of certificates within customer IT infrastructure, Microsoft’s active directory-based authentication, Use of network infrastructure that supports physical network or VLAN segmentation, Placing the web server in a “demilitarized zone” (DMZ), End-to-end encryption, from client to server, End-to-end encryption between servers, Certificate-based data exchange, Encrypted backups.
SITC of High-quality CAPACTIVE touch 7.0'' panels for technical on- site operation of plants as well as room operation. The Touch Panel shall have integrated web server and a BACnet/ IP web interface to connect a HTML5 browser to a device on the network. Generic operation and monitoring of plant functioMR (alarms, schedulers, calendars, set point changes, display of actual values, etc.)
SITC of True IP Based DDC Standalone 32 Bit Intelligent, peer to peer communication, interoperable DDC as per the specification. The compact controller shall have inbuilt 2-port Ethernet switch with WLAN interface. The controller shall have 16 inputs/outputs inbuilt and can be expandable upto max 40 points by Input/Output Modules. The DDC shall have 300 Mhz processor with 128 MByte SDRAM (DDR3) and 512 MByte NAND Flash. The controller shall be freely programmable and have System functioMR (alarming, scheduling, trending, access protection with individually definable user profiles and categories). It should have Cloud connectivity for remote access and inbuilt port for POT for local interface.
The above shall be housed in vandal proof, lockable & secure MS Cabinets to be supplied along with all necessary switchgear protectioMR as required. Number of controllers shall have spare capacity of 15% for future expaMRion.
Controller for VRV System
Controller for AHU system (1 AHU per DDC)
Controller for Axial faMR - Fresh Air faMR & Exhaust - ( 4 FaMR in 1 DDC)
Controller for TraMRformer/LT/HT Panel
Controller for Lifts - (4 lift per DDC)
Controller for Fire Fighting system
Controller for Plumbing System
SITC of True IP Based BTL & UL Listed for third party integration. The controller shall have 2-port Ethernet switch and WLAN interface. It should have BTL label (BACnet communicatioMR passed the BTL test) and coMRisting of Dual microprocessor with Storage capacity of 1 GByte RAM. It should support Real Time clock upto 7 Days. It should Support of the major communication protocols: BACnet,/IP, BACnet MS/TP, Modbus IP and Modbus RTU upto 500 points. Integartor shall be of same make only.
Integration of VRV System on Bacnet/IP
For AHU VFDs on Modbus RS485
For DG Sets on Modbus RS485
For HT/LT on Bacnet/IP or Modbus RS485
For UPS on Modbus/RS485
For Fire ALARM System on Bacnet/IP - 1000 Points
Field iMRtruments
Supplying, iMRtalling, testing and commissioning of the following seMRors / traMRducers / traMRmitters. The DDC shall support seMRor with DC 0...20 mA or 4...20 mA, DC 0 ... 10 V, LG-Ni 1000, 2x LG- Ni1000, Pt 1000 , NTC 10k, NTC 100k, 1000 Ohm.
Combined Ambient Air Temperature + Humidity SeMRor
Differential pressure switch Air
Duct Temprature SeMRor
Flameproof Level TraMRmitter
Voltage TraMRducer
Room Type T+RH SeMRors
SITC of Cabling and Conduiting
2 Core 1.5 Sqmm Annealed Tinned Copper, Twisted pair , Shielded armoured cable for signal and power as per specificatioMR
4 Core 1.5 Sqmm Annealed Tinned Copper, Twisted pair , Shielded armoured cable for signal and power as per specificatioMR
Cat-6 unarmoured cable with required jacks and points
Hot dip galvanised perforated type cable tray
150 x 50 mm x 1.6mm thick
GI Flexible 25 mm
Network Switches
Supply, iMRtallation, testing and commissioning of Layer 2 unmanaged switch with 16/24 ports (RJ-45) port rack mountable, SMPS power supply. The switch to switch distance shall not exceed beyond 80 meters.
STREET LIGHT POLES WITH LED LAMPS & HIGH MAST
Supply, Installation Testing and commissioning of 70W LED Post top light fixtures with elegantly designed die-cast aluminum housing, extruded aluminum (heat sink) for efficient thermal management, sturdiness and excellent corrosion resistant. Al. canopy with PMMA opal cap is provided at the top to enhance the aesthetic of the fixture. Four nos. die-cast aluminum arms are provided to support the housing. Epoxy powder coated black. Multiple PMMA PC lense type III are provided to achieve wide and symmetrical light distribution. Tempered protective toughened glass thermal shock resistant, impact resistant (IK-07) fixed to the housing. Efficacy is 100 lm/w, suitable for mounting on 4.0M height.
40 Watt LED, color temp 3000-6500k as required.
Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job.
60Watt, color temp 3000-6500k as required.
Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
300Watt, color temp 3000-6500k as required.
Supply, Installation testing and commissioning of red colour aviation light LED integral type comprising of aluminium powder coated housing with polycarbonate enclosure IP 65 on existing pipe/support including connection, testing etc. as required. Guarantee as per tender agreement condition.
20 watt (300 LED)
Supply, fixing & testing of approved make of LED integral type bollard cylindrical/square shape housing cast aluminium dome shape top cover fixed with cylindrical shape acrylic cover having base plate with holes for direct mounting complete with all accessories including preparation of foundation, fixing, connection etc. as required. LED of 1 to 3 Watt each assembled on single MCPCB, system lumens output with efficacy>90 lm/W. luminaire having color temp upto 6500K & 50000 burning hrs. life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare, comprises of driver PF> 0.95 & surge protection 10KV. IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
Bollard LED 8-10 Watt mushroom shape height > 600mm, color temp 3000-6000k
Supplying, fixing & testing of approved make flexible LED strip comprising of 60 LED per meter W/O driver for direct mounting complete with all accessories including connection lead, fixing, connection as required. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
Flexible LED strip 24Watt/25Watt - 5 M indoor cove light W/O Driver IP 20 -33
Supplying, fixing & testing of approved make Power supply for LED strip
Power supply 25Watt/30Watt for LED strip IP25/IP33
Supply, fixing and testing of approved make integral step/skirt LED light suitable for 3 module box and plate including fixing on wall as required, with necessary material to complete the job. Guarantee as per tender agreement condition.
Supplying and erection of water tight terminal box made of 16 SWG M.S. Sheet (1.6mm thick) i/c rubber gasket of required size suitable for kit kat/MCB/switch including 2 nos. pole clamp of M.S. flat iron size 32x3mm, nut and bolts, 4 Pole epoxy connector nut & bolt type, 30Amp, 500Volt. The box shall be powder coated excluding the cost of the kit kat/MCB/Switch complete as per specification.
Supplying and fixing of 19mm/20mm dia. M.S. pipe 1 meter in length for CFL/LED street Light/bulkhead/water tight bracket including bending to shape and wiring with 1.5sqmm W.P./PVC wire etc. as required.
Supplying and fixing of 32mm dia. X 2.00 meter long G.I. pipe (medium class) bracket for mounting of fluorescent/S.V/M.H/LED lamp street light fittings on poles including bending the pipe to the required shape and wiring with 1.5sq.mm W.P./PVC wire etc. as required.
Providing and erection on existing foundation 12.5 meter high mast lighting system suitable to install 6 No. 2 x 400 w M.H/S.V/LED flood light fitting and control gear with integral Power tool, weight 340 kg. comprising of 2 section of hot dipped galvanized materials as per BSEN ISO 1461 thickness 3 mm, dia 100mm & 360mm for top and bottom respectively, stress fitting arrangement on site with 350mm overlap dynamic loading to withstand max wind pressure as per-IS 875 part III, parameters for structural & foundation design must be taken from wind tunnel test. Lightning protection of GI single spike 800mm at top and at base inside compartment with double internal lock with adequate size of MCB erected on PVC board complete with base plate of 25mm thick 520mm dia. and foundation bolts having 4 nos. bolts of 24mm dia, 750mm long (EN8 grade), Anchor plate 445 PCD, including accessories viz. (1) Lantern carriage of 50 NB ERW class-B, MS pipe covered with PVC sleeve suitable to carry 250kg. load and upto 6 fittings symmetrically. (2) Trailing copper cable 5x2.5 sq.mm,EPR insulated PCP sheathed.
(3) Double drum/350kg winch having gear 53:1, oil bath (SAE90/140) arrangement. (4) 2 nos. stainless steel wire ropes 5mm dia (7/19) breaking load capacity 1450 kg.x 2. (5) Integral power tool 3-phase, 0.75 HP 2m/min single speed. (6) Feeder pillar fabricated out of 14 SWG CRCA sheet and comprise of incoming MCB 32 A TPN switch, HRC fuses, single dial timer, suitable size of contactors for lighting and power tool, 2 nos. outgoing, reversing switch for motor.
(7) Foundation drawing, test certificate and guarantee certificate shall be provided by manufacturer. (without fixture and lamp)
Providing and erection on existing foundation 16 meter high mast lighting system suitable to install upto 8 No. 2 x 250/ 400 w M.H/S.V/LED flood light and control gear with integral power tool, weight 450 kg. comprising of 2 sections of hot dipped galvanized materials as per BSEN ISO 1461 thickness 3 mm & 4 mm, dia 150mm & 360mm for top and bottom respectively, stress fitting arrangement on site with 500mm overlap dynamic loading to withstand max wind pressure as per -IS 875 part III, parameters for structural & foundation design must be taken from wind tunnel test. Lightning protection of GI single spike 1200mm at top and at base inside compartment having double internal lock with adequate size of MCB erected on PVC board complete with base plate of 25mm thick 520mm dia. and foundation bolts having 6 nos. bolts of 24mm dia 750 mm long (EN.8 grade) anchor plate 445 PCD, including accessories viz.
(1) Lantern carriage of 50 NB ERW class-B, MS pipe covered with PVC sleeve suitable to carry 500kg. load and upto 8 fittings symmetrically. (2) Trailing copper cable 5x2.5 sq.mm, PVC insulated PVC Sheathed (3) Double drum 350Kg Winch having gear 53:1, oil bath (SAE90/140) arrangement (4) 2 nos. Stainless steel wire ropes 5 mm dia (7/19) breaking load capacity 1450 kg x 2, (5) Integral power tool 3-phase, 0.75HP 2m/min single speed .torque limiter upto 500 kg adjustable (6) Single LED 300 Nos. aviation light (7) Feeder pillar fabricated out of 14 SWG CRCA sheet and comprise of incoming MCB 32 A TPN switch, HRC fuses, single dial timer,suitable size of contactors for lighting and power tool, 2 nos. outgoing, reversing switch for motor.
(8) Foundation drawing, test certificate and guarantee certificate shall be provided by manufacturer.(without fixture and lamp)
Providing and erection of hot dipped galvanized octagonal poles in single section made from 3mm thick sheet having lockable weather proof flush door junction box, suitable size & type of foundation bolts 4 nos. 'J' type (EN8 grade) complete, erected in an approved manner on provided foundation.
7 meter height, 130 X 70mm A/F, 220x220x12mm base plate, 4 nos. X 20 x 700mm bolt.
Providing and erection of black painted galvanized decorative designer poles in different section, top 60mm dia., bottom 140mm dia. with gold colour painted ornamental cast aluminium ring having lockable weather proof flush door junction box in bottom section, base plate dia. 290mm having 4 holes of 22mm dia. complete erected in an approved manner on existing foundation. Suitable size & type of foundation bolts 4nos. X 16mm X 450mm 'J' type (EN8 grade)
Designing & casting of open raft shallow footing foundation with M-20 cement concrete suitable for 12.5meter High Mast considering the safe soil bearing capacity at site as 10 T/sqm at 2meter depth including excavation, foundation nut bolts in an approved manner as per manufacturer drawing or Engineer-incharge.
Designing & casting of open raft shallow footing foundation with M-20 cement concrete suitable for 16meter high mast considering the safe soil bearing capacity at site as 10 T/sqm at 2meter depth including excavation, foundation nut bolts in an approved manner as per manufacturer drawing or engineer-incharge.
Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20 (1:1.5:3), required tar steel reinforcement for required size from base concrete, shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner as per manufacturer drawing or engineer-in-charge.
Supply and fixing of IP 65, Surface wall mounted 9W LED up/downlighter decorative wall light fixture with anti glare beam angles 24deg - 36 deg as required. Fixture should be Aluminium with light reflectance surface, SS clamps, screws as required. CRI80+ NON DIM with led power supply built in color tolerance: <MacAdam 4 SDCM LED.
Supply and fixing of IP 65 surface ground mounted 3-6W small LED projector fixture with snoot & Honeycomb louver, product fitted with 700ma 8deg-24deg as required. 3000K-4000K CRI80+ NON DIM with led power supply built in color tolerance: <MacAdam 4 SDCM LED mounting AR111 similar optics PC lens. Fixture should be Aluminium die cast, SS clamps, screws as required. The finish should be stainless steel.
Supply and fixing of recessed ground mounted deep LED uplighter fixture with Honeycomb Louver. protected Uno PATHFINDER IP66 2700K-5500K 8deg-24deg as required. stainless steel body hard anodized aluminium finishes stainless steel & IK rating 08. Installation housing box power supply cables35 cm NS20N PCP 2x0,5 mm2 power supply 24V DC power consumption max 9 Watt lumen output 240- 680lm working temperature-20°C +45°C IP rating IP66 (not for permanent immersion) insulation class III Weight upto 500gm. and delivers 90CRI for excellent colour rendering, and with binning-free LEDs carefully selected from two-step Macadam’s ellipse. PATHFINDER is smart shield protected against polarity inversion, an integrated super fast diode prevents accidental damage to the luminaire during installation on due to reverse polarity. Smart shield protects against ‘hot-plugging’. Fully integrated spike-reduce on protects the constant- current driver and prevents damage to the LED die surface. With housing box included and LED driver in IP66 casing box included.
3W recess deep uplight
Supply and fixing of IP66 protected aluminium instant outline direct view diffuse 3000K-5000K with back profile with integrated cable alley for cable management with integrated IP rated cable connectors hidden within profile for additional protection from weather. Cross section of profile Silver anodized surface mounted aluminum profile 25 mm (W) x 20 mm (D) (minimum), with opal semi translucent sealed encapsulation, protection grade IP66, Minimum 85 lm/watt, DC 24 V, CRI>80Ra, standard length 2000 mm. excl. converter and end caps. The support is made of an anodized extruded aluminum frame which makes it possible to first fix SS the wall/ceiling.
Supply and fixing of IP66 protected aluminum instant outline 10W/pm flexible LED direct view diffuse 3000-5000K/RGB with back profile with integrated cable alley for cable management with integrated IP rated cable connectors hidden within profile for additional protection from weather. Cross section of profile Silver anodized surface mounted aluminum profile 35 mm (W) x 35 mm (D) OR 50 mm (W) x 50 mm (D) (minimum), with opal semi translucent sealed encapsulation, protection grade IP66, DC 24 V, 750 lm/m, 10 W/m, CRI>80Ra , standard length 2000 mm. Excl. converter and end caps. The support is made of an anodized extruded aluminum frame which makes it possible to first fix SS the wall/ceiling.
RGB DMX controller having 24V/48V DC input maximum 300W.
RGB DMX SLAVE having 24V/48V DC input.
Supply and fixing of recessed ground mounted deep LED marker fixture with diffused light 3000K-5000K, CRI>80, 45deg-60deg stainless steel 1W-3W, bodyhard anodized aluminium finish, stainless steel & IK rating 08. working temperature -20°C +45°C IP rating IP66 (not for permanent immersion) insulation class III weight upto 100gm, protected against polarity inversion, fully integrated spike-reduce on protects the constant current driver and prevents damage to the LED die surface, with housing box included and LED driver in IP66 casing box included.
Supply and fixing of LED RGB/RGBW flood lighting luminaire for facade lighting with Die- cast aluminium housing, powder- coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 . Fixture shall be suitable to operate at an ambient temperature range of - 10°C to +50°C and shall be IP 65 and IK 06
rated. Lifetime shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
Supply and fixing of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/ Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
supply and fixing following capacity of automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors, HRC fuse, isolating switch, metering instrument and instrument box with CTs etc.complete in all respect.
TRANSFORMERS - 33KV/433V
Supply, testing & commissioning of Outdoor mounted type 33 KV / 433 Volt Transfomer (as per IS : 2026, P1 to P5), 3 phase, 6.25% impedance, Dyn 11 vector group, 50 cycles, (ONAN) oil immersed naturally cooled, step down, copper wound, continuous duty, temperature rise above 50oC in oil by thermometer 40oC, in winding by resistance 45oC and other standard accessories as required including followings :
The Transformer losses should confirm to IS : 1180 with latest amendments at the time of instalation.
a) Cable Termination box with disconnecting facility for 33 KV 3C-300 sq mm XLPE cable at 33 KV side
b) LV side box suitable for suitable Amp bus duct termination
c) Automatic On Load Tap Changer +10% to -10% @ 1.25% in 16 equal steps with RTCC Panel (Remote tap changer control panel) consisting of followings -
High torque, electric motor suitable for 415V 3 Ph. 50 Hz., AC supply.
Motor drive and energy accumulator.
Monitor isolating device with overload protection.
Contactors for Forward & Reverse operations of motor.
Oil Surge Relay
“RAISE / LOWER” control for local operation.
“LOCAL / REMOTE” control selector switch.
“RAISE / LOWER” limit switches.
Stepping Relay.
Auxiliary Transformer.
d) Bidirectional rollers.
e) Oil Conservator with filter cap, drain plug & oil level gauge
f) Earthing terminals 2 nos for body earthing.
g) 0.415 KV neutral seperately bought out on a bushing for neutral earthing.
h) Neutral CT as required.
i) Pressure release device. Double diaphragm explosion vent.
j) Radiators Detachable type with top & bottom shut off valve.
k) First filling of filtered dehydrated oil as per IS : 335 including make up fill during installation & 10% extra.
l) Silica gel breather with connecting pipe & oil seal.
m) Rating, Diagram & Terminal marking plate of SS.
n) Sampling Valves for filteration, drainage and filling with plugs.
o) Air release plugs.
p) Thermometer pocket with plug.
q) Lifting Lugs.
r) Double float Buchholz relay with gas release cock, alarm & shut off valve on either side with separate set of contacts for trip and alarm.
s) 150 mm Winding temperature indicator (WTI) with alarm. (for 800 KVA & above)
t) 150 mm Oil temperature indicator (OTI) with alarm
u) Marshalling Box.
v) Clamping device.
w) Jacking Pads.
x) Ladder with safety device for access to the top of transformer tank.
The work shall be complete in all respects up to the satisfaction of Engg-in-charge.
(33 KV - 6 VCB PANEL)
Supply,installation, testing & commissioning of indoor type floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 54, The switchgear boards shall have a single front, single tier, fully compartmentalized, metal enclosed construction complying with clause No. 3.102 of IEC 62271-200, comprising of a row of free standing floor mounted panels. Each circuit shall have a separate vertical panel with distinct compartments for circuit breaker truck, cable termination, main bus-bars and auxiliary control devices. The adjacent panels shall be completely separated by steel sheets except in bus-bar compartments. The Service Class Continuity of Switchgears shall be LSC 2B-PM (as per IS/IEC 62271-200) • The Switchgear shall have an Internal Arc Classification of IAC AFLR. Switchgear shall have an internal arc of 31.5kA for 1 second.In case of any Inspection window provided on breaker compartment door, same should also be in line with IAC classifications. comprising of 1250Amp, continuous rated Copper busbars and droppers, 01nos. Rack-In-Rack-Out Handle, structure made from AluZinc/GI sheets to prevent corrosion and rusting.The complete panel incl. HT and LT chamber shall be manufactured by approved OEM at its own facility, and same will be verified via stage/final inspection. License parter, system integrator, panel builder, half-panel concept is not allowed. 33 KV 4 VCB HT Panel fully encapsulated pole VCB breakers (1 incomer and 3 out goings), totally enclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker, having capacities as mentioned below, single break, trip free mechanism, motorised charged and auto closing breaker suitable for use on 33 KV, 3 Phase, 50 Hz A. C. supply with short circuit fault level of 31.5 kA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but continuous rated Copper busbars and droppers , Cu. earth bar, earth bar, breaker featured with mechanical ON / OFF indicator with hand trip device, spring release coil, shunt trip coil, control voltage of 24 Volt DC, TNC, LED type indicating lamps for phases and trip conditions and auxiliary switch of 6 NO + 6 NC and equipped with following switchgears and accessories.
The panel should be suitable for connections for up to 3 x 300 sq.mm XLPE 33 KV cable (cable entry from bottom/top/side), end termination with heat shrinkable jointing material etc. as required. (The Cost of end termination not included in this item)
power pack ( 1 working & 1 standby) with 220 Volt AC input & 24 Volt DC continuous output suitable for indicating lights & closing / tripping / indication of 5 Nos. HT panel boards with 2 Nos. 12 Volts each maintenance free batteries of suitable AH (Min 4 Hrs back up for each relays & indication) each, charging unit, capacitor bank for emergency delivering for trip system complete with suitable capacity of Ammeter & Voltmeter i/c connections with 2.5 sq.mm FRLS insulated copper conductor cable etc. including DC DB consisting of required MCB's for DC supply distribution to panels as required.
As per above item with following mountings-
2 Nos. 1250 Amp. VCB breakers with followings in each breaker -
33kV, 1250Amp, 31.5kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03 Nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC)
(a) 1 set (3 nos) 33 KV / √3 / 110 / √3 Volts drawout type PT Class 0.5 accuracy and 50 VA burden with 1 No. Voltmeter (0-36 KV), digital type, selector switch for voltmeter and protection fuses/MCB for HT metering.
(b) 3 nos. dual core dual ratio CTs of ratio 200/100/1/1A of 7.5 VA burden and accuracy class-0.5 for metering and class 5P10 for protection.
(c) 1 No. - (0-200A) Ammeter, digital type with selector switches.
(d) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having 04CT+05PT Inputs with microprocessor based protection scheme for tripping the breaker on various faults like (1) directional over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults, (3) residual and three-phase under-voltages/over-voltages (4) Synchronism and Energizing Check before breaker closing to prevent un-syncronized mixing of supplies (5) circuit-breaker-failure alarm, (6) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol. The relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. various status, Line-Current, Line-Voltage etc. and display the same locally on a built-in back-lit LCD screen as a Single-Line-Diagram with power & frequency measurements and suitably labelled status LEDs. TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software. Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.
(e) Master trip relay
(f) Trip circuit supervision relay
(g) Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, KVAH, KVARH, PF, HZ & MDI with RS 485 port.
(h) Timer and TNC switch
4 Nos. - 630 A VCB breakers with followings in each breaker -
33kV, 630Amp, 31.5kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03 Nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC)
Note - Provide all type of Protection, Auxillary relays, release for the transformer protection as the outgoing feeders shall feeds the power to transformer.
(a) 3 nos. dual core dual ratio CTs of ratio 50/1/1A of 7.5 VA burden and accuracy class-1 for metering and class 5P10 for protection.
(b) (0-50A) Ammeters, dual scale digital type & selector switches for ammeters.
(c) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having 04CT+05PT Inputs with microprocessor based protection scheme for tripping the breaker on various faults like (1) directional over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults, (3) residual and three-phase under-voltages/over-voltages (4) Synchronism and Energizing Check before breaker closing to prevent un-syncronized mixing of supplies (5) circuit-breaker-failure alarm, (6) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol. The relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. various status, Line-Current, Line-Voltage etc. and display the same locally on a built-in back-lit LCD screen as a Single-Line-Diagram with power & frequency measurements and suitably labelled status LEDs. TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software. Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.
(d) 12 window Annunciation panel with necessary relays, audio and visual indicators and push buttons.
(e) Auxilliary relay for Buchholtz / OTI / WTI
(g) Master trip relay
(h) Trip circuit supervision relay
HT Panel - 07 as described above
Supply of approved high-tension XLPE cable (conforming IS-7098/II/85) as per ISI standard 3 core armoured with alu. solid/stranded conductor ISI marked as required.
3 core XLPE cable 33 Kv grade
Providing & Making cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 33 KV/11 KV 3 core XLPE alum. conductor cable as required as per specification and as per accepted standard including connection testing complete.
Heat shrinkable Jointing kit 33 KV XLPE cable O.D. termination
Heat shrinkable Jointing kit 33 KV XLPE cable I.D. termination
Laying of one number 3 core H.T armoured/unarmoured power cable of grade 33KV of size not exceeding 300 sq.mm direct in ground including excavation in all soil/murrum/soft rock, sand cushioning, excluding protective covering and refilling the trench etc. as required.
Laying of one number additional 3 core H.T armoured/unarmoured power cable 33KV grade of size not exceeding 300 sq.mm direct in ground in the same trench in one tier horizontal formation including sand cushioning, excluding protective covering and refilling the trench etc. as required.
Laying of one number 3 core H.T armoured/unarmoured power cable 33KV grade of size not exceeding 300 sq. mm in the existing RCC/hume/stoneware/G.I. pipe/surface in existing trench as required.
Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked) for cable laid underground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good.
63.00mm outside dia.
90.00mm outside dia.
120.00mm outside dia.
180.00mm outside dia.
210.00mm outside dia.
MAIN LT PANEL :
Design, manufacture, supply ,installation, inspection, handling, assembling, affecting proper connections, testing and commissioning of Main L.T. Panel (with 275GSM GI/CRCA) floor mounting, dust & vermin proof, front operated construction, enclosure class - IP54/42. The bubsbar shall be of aluminium. The panel should be double door design for safety of operator.The panel has to a bolted design and no welding shall be allowed.The main parts like Upright (Frame) 9 fold design,Busbar Support & Corner pieces 3 way of panel should be supplied by OEM to system integrator and copy of inoices(without price) to be submit by System integrator during drawing approval & inspection for authenticity purpose. No changes in the IEC or models/makes of panels as specified in this particular BOQ itself shall not be allowed to ensure high quality of products for hospital. The main LT panel shall be as per IEC61439 (TTA).
Authorized certificate and agreement copy with OEM to be submit while drawing approvals through contractor. Tender based authorization or any other certifications shall not be valid.Further,Only OEM's system integrator for TTA panels as per IEC61439 (Models as specified above)shall only be allowed to manufacturer & supply Non TTA panels also like HVAC, Sub Panels, AHU Panels,Control Panel,Fire Fighting Panel to maintain the high quality vendor for complete LT Panels.No other manufacturer shall supply NON TTA panels even if it is specified in make list.
INCOMERS from 3 Nos. 2000 KVA Transformers
3 Nos. 3200A 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release EDO OL,SC,EF Icu = 65KA having modbus TCP/IP onboard communication on ACB(Without use of any converter or external hardware) and ACB should have a communication redunancy option(That means 2nos Modbus TCP/IP module to be used on board on ACB without use of any converter along with Power Supply). The gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewving software. The integration of communication from ACB to gateway to energy & assest management software of switchgear OEM shall be in scope of the System Integrator
The ACB shall be electrically and mechanically interlocked with the bus coupler, DG incomers and other transformer incomers.
Protection releases / relays, Metering & Accessories for each Transformer incomers.
Over Voltage / Under Voltage relay / release with timer.
Restricted earth fault relay.
Master trip relay.
Trip Circuit Supervison relay.
Auto manual selector switch.
1 nos. 0-500 volt range digital type voltmeter with selector switch
1 set of 3 CT's of ratio 3200/5A, Class 1.0 accuracy 15 VA burden for metering.
1 set of 3 CT's of ratio 3200/5A, Class 1.0 accuracy 15 VA burden for APFCR.
1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse.
1 set of 4 CT's of ratio 3200/1A, Class PS for protection.
1 no. 0-3200 Amp range digital type ammeter with selector switch.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. (or Dual meter)
Power factor meter.
Frequency meter.
4 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons.
4 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB.
INCOMERS from DG SYNCHRONIZING PANEL
3 nos 2000A 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release EDO OL,SC,EF Icu = 65KA with modbus TCP/IP onboard communication on ACB(Without use of any converter or external hardware) and also having a communication redunancy option(That means 2nos Modbus TCP/IP module to be used on board on ACB without use of any converter along with Power Supply).The gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewving software. The integration of communication from ACB to gateway to energy & assest management software of switchgear OEM shall be in scope of the System Integrator
The ACB shall be electrically and mechanically interlocked with the bus coupler, DG incomers and other transformer incomers.
Protection releases / relays, Metering & Accessories for each Transformer incomers.
Over Voltage / Under Voltage relay / release with timer.
Restricted earth fault relay.
Master trip relay.
Trip Circuit Supervison relay.
Auto manual selector switch.
1 nos. 0-500 volt range digital type voltmeter with selector switch
1 set of 3 CT's of ratio 2000/5A, Class 1.0 accuracy 15 VA burden for metering.
1 set of 3 CT's of ratio 2000/5A, Class 1.0 accuracy 15 VA burden for APFCR.
1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse.
1 set of 4 CT's of ratio 2000/1A, Class PS for protection.
1 no. 0-2000 Amp range digital type ammeter with selector switch.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. (or Dual meter)
Power factor meter.
Frequency meter.
4 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons.
4 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB.
2 nos ACB 3200A 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release EDO, Icu = 65 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator
Protection releases / relays, Metering & Accessories for Bus Coupler (s)
Trip circuit supervision relay
Auto/manual selector switch
4 Nos. LED type indicating lamp for indicating the status of feeder - ON/OFF/TRIP/Trip circuit healthy/DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
The bus coupler shall be electrically and mechanically interlocked with all incoming ACB's in such a way that at any one time two supply should not get mixed up.
3 sections of 5000 AMP, 415 Volts, 3 phase 50 HZ 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints.
The current density of bus bar up to 1000 Amp shall be minimum 1.00 sq mm/amp & for 1250/1600 amp shall be minimum 1.30 sq.mm/amp and for 2000/ 2500/ 3200/ 4000/ 5000 Amp shall be minimum 1.60 sq mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C.
Bus PT Module 5 Nos., each with Following:
3PH. 415/v3/110/v3 V 100VA with Fuses.
R,Y,B Ind. Light with Control Fuses
(Note - All the indication & metering shall be done through 110V from secondary of PT's. No indication lamps & metering should not be operated at 415 Volts.)
PLC for load management / automation
Design, manufacturing, testing at works, supply of PLC BASED , AUTOLOAD TRANSFER, AUTOLOAD BALANCING PANEL FOR 3 nos. 1010 KVA. complete as required to acheive the desired functions.
PLC shall be provided in main LT panel for interlocking between different incomers and bus couplers to avoid unintentional paralleling of different supplies.
PLC is not envisazed for DG synchronization
PLC with VIEW PANEL.
In addition to required hardware and software following components shall also be provided.
Based on the load requirement only required no. of DG sets shall be operated.
Monitoring of DG set safeties (mechanical as well as electrical).
PLC Hardware as required
Auxiliary relays/contactor/metering/protection etc as required
230 V AC, UPS alognwith battery of suitable back up of suitable rating
Annunciators as required
One no. Battery charger set consisting of Transformer / Rectifier, DC ammeter, DC voltmeter, Charging rate selector switch, Off/Trickle/boost.
All control wiring from PLC to various feeders with min. of 2.5 sq mm copper FRLS cable.
The PLC provided for Load Management & for interlocking of Breakers shall perform to achieve the system as described in given Main Schemetic Diagram.
All outgoing feeders shall be provided with one set of phase indication lamps and trip indication lamps with protection fuses/MCB and ammeter with selector switch with suitable ratio CT's of accuracy class 1.0
All outgoing feeders fed from TX/DG Bus Bar shall be provided with energy analyser/electronic dual reading KWHR meter with RS 485 communication port, CT's with accuracy class 1, control circuits and wiring as per SLD.
3 nos ACB 1600A 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release EDO, Icu = 65 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator
3 nos ACB 1250A 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release EDO, Icu = 65 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator
3 nos ACB 1000A 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release EDO, Icu = 65 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator
3 nos ACB 800A 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release EDO, Icu = 65 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator
All MCCB's should be ICS=100%= ICU. Single frame from 32Amp to 250Amp & 400/630Amp of single frame. MCCB upto 250Amp should be Adjustable Thermal Magnetic & above 250Amp should be Microprocessor with Built-in μP based trip unit having protection functions LSIG. Variable current setting for L,S,I and G and variable time delay setting for L,S and G. Neutral O/L protection possible with 3P MCCB (with External Neutral CT). Last Fault trip history on LCD screen of MCCB i.e Faulty phase, Type of Fault and interrupted current.
3 nos. 630 AMPS 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release MCCB with Inbuilt OL,SC,EF (Without use of any external device)(35 KA)
10 nos. 400 AMPS 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release MCCB with Inbuilt OL,SC,EF (Without use of any external device)(35 KA)
3 nos. 200 AMPS 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release MCCB with Inbuilt OL,SC,EF (Without use of any external device)(35 KA)
1 nos. 200 AMPS 4P OL,SC,EF with Colour Wide screen Display having Overtempeperature feature in release MCCB with Inbuilt OL,SC,EF (Without use of any external device)(35 KA)
Main LT Panel as described above
HYBRID POWER FACTOR CORRRECTION PANEL - (600KVAR+7% DETUNED COPPER REACTOR) :
Design and supply of Hybrid Power Factor Correction Panel (APFC) of capacity 440V, 3-phase, 50 Hz. The passive 600 KVAr stage ratings shall be 1x10kVAr + 1x15kVAr + 1x25kVAr + 2x50kVAr + 2x75kVAr + 1x100kVAr + 1x200kVAr. The APFC Panel shall be fully type tested and shall comply to IEC 61439-1&2 and IEC 61921 Or IS 16636-2017. The APFC Panel shall be (Indoor) type, weather, dust and vermin proof. The degree of protection of enclosures system of the APFC Panel shall be min. IP54 in accordance with IEC 60529. The capacitor bank shall be Internet of things (IoT) enabled and communicable/ integrable with EMS. The APFC panel should have the capability for environmental monitoring where it is able to provide the real time data for the temperature and humidity inside the panel ambient. The environmental sensors shall be used with a access point, which can be used for multiple sensors, using Green Power wireless communication protocol to transfer the information on real time basis to have the exact and detailed temperature monitoring of the Cap bank conforming to IS13341:1992 & IS 13440:1993 floor mounted design, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m above sea level.
(A) Insulated bus bar assembly made from Aluminium and rated of 1000 Amps capacity. The short circuit withstand capacity shall be 65 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV.
( B) The incomer of the APFC Panel shall be a 1000 Amp, ACB, 3P, 50kA Microprocessor based ET trip systems with thermal memory with O/L & S/C protection, Icu=Ics=Icw=50kA for 1sec @440V, ACB shall have standard extended rotary handle, spreaders, phase barrier. ACB shall be of certified design confirming to IEC 60947-1,2 & 3.
(C) Capacitor Units: The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 480V and shall have a maximum over current capacity of 1.8 In & Peak inrush Current 250In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors (50V in 1min) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993, 13341-1992 & IEC -60831-1&2.
(D) Reactors : The de-tuning reactors shall be connected in series with each capacitor stage and shall be of iron cored type. The reactors shall have relative impedance of 7%, with a de-tuning frequency of 190 Hz. approx. The reactors shall have built in thermostats to protect from overheating. The reactor insulation shall be min. Class “H” rated at 180 degree C. The reactors shall be of certified design confirming to IEC-60076 - 6.
(E) Short-circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB with an electronic over-current relay for short-circuit and overload protection. The electronic over-current relay shall be adjusted to trip if the RMS current of the stage exceeds the overload setting. The MCCB shall be of certified design confirming to IEC 60947-1,2 & 3.
(F) PF Regulator : Advanced Range PF Regulator shall have 11 steps with a LCD Display, Voltage Range : 90V - 550V, 50, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326.
(G) In addition to the PF Controller, the capacitor bank, should also have an energy server which would collect, store, and provides web access and visualization to various energy parameters and enable remote supervision from BMS. To ensure maximum utilization, enable remote commissioning / trouble shooting of the capacitor bank, the energy server should monitor and display the following parameters remotely through a Web Page.- Status of stages (open / close / faulty). - Real time capacitance value of the connected stage. - Initial capacitance value. - Number of operation of stages ( stage utilization / operation) - energy parameters like : I, V , P , Q, S , Operating PF, Target PF, Operating Temperature , Max Temperature, % THD V, %THD I - Display of alarms - Trending curves of historical recorded data.
(H) Stage Contactor : The electromagnetic contactors shall be rated for 660 Volts and shall be capacitor duty 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of (+) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IEC 60947-1 & 4-1.
(I) Ventilating fans of required size shall be used to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks shall be of type tested design and temperature rise test report of the capacitor bank.
DG SYNCHRONIZING PANEL
Supply, Installation, Testing and Commissioning of Power Control Center Based Auto Synchronizing Auto Starting Auto Sharing & Auto Load Management with PLC System panel suitable for 3 x 1010KVA DG sets. Comprising of 3 nos Incomers rated at 1600A. Bus Couplers rated at 1600 A & 3 nos. Out going rated at 1600 A with 3 nos AMF Panels. Complete in all respect as reqd as per detail. Manual Synchronizing 1 No. 144 mm sq. double voltmeter. 1 No. 144 mm sq. double frequency meter. 1 No. 144 mm sq. synchroscope 1 No. synchronizing switch. 1 Set selector switch. 1 Set dark lamp ( 60 watt). 1 No. check synchronizing relay.Auto Synchronizing, Auto starting, Auto sharing and auto-load management with PLC system. The PLC panel shall be located in separate room. 2 Nos. volt monitors for DG supply. 1 No. volt monitors for main supply. 1 No. PLC 1 No. Annuciator with required windows.
3 Nos. power monitor modules. PLC Rack. Digital input modules. Digital output modules. EPROM (EP) Man Machine inter face (MMI) Software for PLC1 SET MIMIC. (SEM) Set of auxiliary relays. Set of indicating lights and push buttons. Set of control MCBS. 1 No. Auto Manual test switches.
DG Synchronizing Panel as described above
AUTOMATIC FIRE DETECTION & SUPPRESSION SYSTEM in PANEL
UL Certified Extinguishing agent filled in PESO Approved Filling Station: 5 Kg FK‐5‐1‐12 Clean agent filled in PESO approved stored pressure type seamless steel cylinder as per IS 7285 with DLP Valve Assembly, Safety Burst Disc at 28 Bar and Mounting Bracket with all necessary fittings & supports Stored Pressure type fitted with Pressure gauge, UV Resistance, Operating Pressure 15 bar, Hydraulic Pressure Tested to 250 bar, Burst Pressure at 350 bar, Red Powder coated.
UL Certified Extinguishing agent filled in PESO Approved Filling Station: 10 Kg FK‐5‐1‐12 Clean agent filled in PESO approved stored pressure type seamless steel cylinder as per IS 7285 with DLP Valve Assembly, Safety Burst Disc at 28 Bar and Mounting Bracket with all necessary fittings & supports Stored Pressure type fitted with Pressure gauge, UV Resistance, Operating Pressure 15 bar, Hydraulic Pressure Tested to 250 bar, Burst Pressure at 350 bar, Red Powder coated.
UL Certified Linear pneumatic Heat Detection Tube for automatic fire detection & supperession system made by special modified polyamaide (PA), colour red RAL300, burst temperature 1000C to 1400C, inner diameter 4mm, outer diameter 6mm. Pressurised with dry nitrogen at 15 bar pressure with all necessary fittings & supports.
Master Control Unit with audio visual alarm Control Panel, 12 Volt battery, 2 NO/NC potential free relay contact for Main Fire Alarm/BMS/SCADA Integration. Gas discharge led indicator, battery led indicator, system status Led indicator , AC power ON Led indicato with all necessary fittings & supports.
Supplying, instalation, testing and commissioning of following capacity Sandwich Type Bus duct for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-67 rating after fixing all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
1600 A 50kA SC for 1 sec
2000 A 50kA SC for 1 sec
3200 A 50kA SC for 1 sec
Supplying and laying of 1000 mm wide x 3 mm thick insulated mat made from highly electrical resistant elastomer of tested quality to withstand 65 KV dielectric strength as per IS 15652 complete in all respects. (For 33KV)
Supplying and laying of 1000 mm wide x 2 mm thick insulated mat made from highly electrical resistant elastomer of tested quality to withstand 30 KV dielectric strength as per IS 15652 complete in all respects. (For LT Panels)
Supplying and fixing of fire bucket, round bottom made of GI sheet 9 to 11 liters capacity duly painted as per fire brigade design, supported on hanging bracket chained and locaked, initially filled with fine river sand, water as per direction of Engineer Incharge.
Supply and erection of shock restoration chart in glass frame
Supplying and fixing of first aid box as approved complete with standard kit as prescribed by Indian Red Cross.
Supplying & laying of following size DWC HDPE pipe ISI marked alongwith all accessories like socket, bend, couplers etc. confirming to IS : 14930 Part-II complete with fitting, cutting & jointing etc. direct in ground (75cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc. as required.
200 MM dia (OD - 200 MM & ID - 175 MM nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickkness of 10cm including inscription duly engraved as required.
Supply, testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 14 / 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following.
Diesel Engine -
Diesel Engine suitable for driving alternator of below rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for below output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.
Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings :
Start stop switch with key
Water temperature indication
Lubrication oil pressure indication.
Lubrication oil temperature indication.
Battery charging indication
Over speed indication
Low Lube oil trip indication
Engine hours indication
Synchronous Alternator of below capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for bus duct termination as required.
Note : - Alternator should have with all other accessories as per specified in Technical specfications.
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.
Power Controller For DG synchronization
Microprocessor based Power command controller (P.C.- 3.3 Jakson or equivalent) suitable for auto / manual synchronization & auto load sharing.
Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required.
Exhaust Silencer - Exhaust manifold with residential silencer.
The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system.
Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.
Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of smoke exhaust piping (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip (as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required.
350 mm dia.(75 mm thick insulation)
250mm dia.(75 mm thick insulation)
Supply & fixing of SS Bellow of following diameter
Supply & fabrication of D G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MS angle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation. incuding RCC Foundation.
Supplying, Laying, terminating, testing, commissioning of folowing sizes of Copper Conductor XLPE insulated, PVC sheathed armoured cable 1100 V grade. On surface the cable run shall be fixed on G.I. clamps etc of suitable size or as directed by the E-I-C complete in all respects. Supply and providing cable identification markers. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. as per specifications complete as required.
3 C x 2.5 sq.mm
Making end termination with brass double compression gland including crimping of copper solderless lugs/ferrules for armoured power copper conductor cables of 1.1 KV grade of following sizes.
3 C x 6 sq.mm (Copper)
3 C x 4 sq.mm (Copper)
3 C x 2.5 sq.mm (Copper)
HSD STORAGE AND SUPPLY SYSTEM 20KL
SITC of HSD storage tanks 25 KL capacity (6mm thick flat end) as per IS : 10987-1992 and approved for construction, shop drawings duly approved by “CCOE” suitable for under ground installation including the following:
a. Inlet and outlet connections
c. Dip pipe assembly with calibration chart
d. 550 mm dia manhole with cover.
e. Lifting lugs
g. Providing Anti corrosive Pypcoat (AW4) treatment.
HSD storage tank as described above
SITC of electrical driven rotary gear-pumps suitable for pumping of HSD
Supply of M.S. class ‘C’ (heavy duty) pipe
SITC of 80 Nb Flexible Hose pipe with AL Adopter for filling of HSD in BOT
SITC of Pot-Strainer
SITC of oil flow meter 80 nb with flanged end for HSD service.
SITC of cast steel ball valves
SITC of cast steel non return valves
SITC of Y Strainer
SITC of 1DLP Laser Projector, 9600 Lumens, WUXGA (1920 x 1200) Resolution, 3000000:1 Contrast Ratio, High-efficiency blue laser phosphor, Standard inputs: HDMI (1.4a), HDMI 2.0, HDBaseT, 3D Sync In (BNC), VGA, Audio In (3.5mm phone jack), USB-A, Signal outputs: 3D SYNC Out (BNC), HDMI, Audio Out, 1.25-2.0:1 (1.6x throw ratio) motorized lens - powered zoom, focus and offset, IP5X dust-resistant, 24/7 performance etc all complete
SITC of 1DLP Laser Projector, 8500 Lumens, WUXGA (1920 x 1200) Resolution, 3000000:1, Contrast Ratio, High-efficiency blue laser phosphor, Standard inputs: HDMI (1.4a), HDMI 2.0, HDBaseT, 3D Sync In (BNC), VGA, Audio In (3.5mm phone jack), USB-A, Signal outputs: 3D SYNC Out (BNC), HDMI, Audio Out, 1.25-2.0:1 (1.6x throw ratio) motorized lens - powered zoom, focus and offset, IP5X dust-resistant, 24/7 performance etc all complete
SITC of Ceiling Mounting Arrangement for the above projector with all required accessories etc all complete
SITC of Recessed-Ceiling Motorized Projector Lift, Max Projector Size: 500 x 500 x 200 mm, Max Carrying weight: 25 KG, Drop: 1000mm (1 Meter), Control System: RF Remote Control, RS232/485, Wall-Switch etc all complete
SITC of 226" Recessed Ceiling Motorized Projection Screen, Aspect Ratio: 16:10, Tubular Motor, Fiber Glass Fabric, Gain 1.0, Viewing angle : 160 °, Built-in RF/IR remote control, RS485 & dry contact etc all complete
SITC of 164" Recessed Ceiling Motorized Projection Screen, Aspect Ratio: 16:10, Tubular Motor, Fiber Glass Fabric, Gain 1.0, Viewing angle : 160 °, Built-in RF/IR remote control, RS485 & dry contact etc all complete
SITC of 137" Recessed Ceiling Motorized Projection Screen, Aspect Ratio: 16:10, Tubular Motor, Fiber Glass Fabric, Gain 1.0, Viewing angle : 160 °, Built-in RF/IR remote control, RS485 & dry contact etc all complete
SITC of 109" Tubular Motorized Screen with Multi Control ( Dry Contact - RS 485), I Remote with 500 mm Extra Black Drop & comes with HD matte White Fabric, Aspect Ratio 16:10 etc all complete
SITC of 55" Professional Ultra HD Display Panel, 4K UHD (3840x2160) Resolution, Brightness 400 Nits, Dynamic Contrast Ratio: 500000:1, Viewing angle (horizontal / vertical): 178 / 178 degree, Display Colours: 1.07 Billion, Panel technology: IPS / Direct LED, Contrast ratio (typical) 1300:1, Connectivity: Video Input: 2 HDMI 2.0, 2 USB 2.0, DVI-I, Audio In, Audio Out, COntrol: RS232, Ethernet, 2x10W Built-in speakers, CE, FCC, Class A, BIS Certified etc all complete
SITC of Fixed Wall Mount, capable of holding up to 45 kg and supports 32" to 65" displays, VESA Compliant etc all complete
SITC of Cable Cubby with flip top, cover and multi-format cables, 2 Universal Power, 2 USB Charger, 1 HDMI, 1 USB-C, 1 Ehternet Cable, made of steel and aluminium etc all complete
SITC of Wireless Presentation Platform, allows simultaneous content sharing for up to four 1080p presenters, Wireless screen casting with iOS, Android, Mac, Chromebook, and Windows devices through native AirPlay, Google Cast, or Miracast protocols, Supports YouTube Live streaming, Local storage available for playback of images and video, WPA2-PSK, and AES-128 encryption etc all complete
SITC of Network PTZ Conference Camera, 20x optical zoom and 60° horizontal FoV, 1/1.8” low-noise CMOS Sensor, Sensor Scanning Mode: Progressive, Horizontal Rotation Range: ±170°, Vertical Rotation Range: -30° to +90°, Image rotation for ceiling mounting, White Balance: Auto, indoor, outdoor, one-push, manual, specified color temperature, IP Stream Resolutions: H.264 @ 360p, 270p or 180p, a single network cable for video, power and control data transport, HDMI 2.0 and 3G-SDI Outputs Power Over Ethernet (PoE) support etc all complete
SITC of Network PTZ Conference Camera, 12x optical zoom and 60° horizontal FoV, 1/2.8” low-noise CMOS Sensor, Sensor Scanning Mode: Progressive, Horizontal Rotation Range: ±170°, Vertical Rotation Range: -30° to +90°, Image rotation for ceiling mounting, White Balance: Auto, indoor, outdoor, one-push, manual, specified color temperature, IP Stream Resolutions: H.264 @ 360p, 270p or 180p, a single network cable for video, power and control data transport, HDMI 2.0 and 3G-SDI Outputs Power Over Ethernet (PoE) support etc all complete
SITC of 15.6 inch Touch Panel, Full HD (1920x1080) Resolution, Pen Display, IPS Display, Color Depth 16.7 million (8 bits), Aspect Ratio 16:9, Brightness 210 cd/m2, Pen Type: Pressure-sensitive, cordless, battery-free, HDMI port and standard USB-A port, Windows® 7 or later (latest service pack/build), OS X 10.12 or later (latest update) support etc all complete
SITC of In Room PC, Ultracompact with 11th Gen Intel Celeron or Pentium mobile processor, fanless chassis for 6W CPU, USB Power Delivery – including input, 2.5 GbE LAN, WiFi 6, Windows 10 Pro and dual USB 3.2 Type-C, with Windows 10 Pro etc all complete
SITC of of Digital Podium: Material: Mild Steel; Should have Tray for Keyboard..It should also have the flexible options in sizes for the 19” or 22” Interactive Panel to fit in. The top should be of wood. Should have a space for the Desktop in the 19” rack for the equipments to fit in as per the International standards. Sliding Shelf/Tray with Locks - For placement of extra lap top or Document and for Presenter with Internal Lock. It should have door locks etc all complete
SITC of Universal Switcher with HDMI and USB-C connectivity, 1 HDMI Inputs, 1 USB-C connectivity (4K Video, Audio, Data, Power charge), 1 HDMI Outputs, 4 USB-A 3.0 Connection (for USB Devices), 1 USB-B 3.0 Connection (for PC hosts), USB host switching, Analog audio de-embedding, Charging via USB-C up to 60w, Supports HDMI 4K signal formats (4K UHD @60Hz RGB 4:4:4, up to 18 Gbps), DP Alt Mode, HDMI 2.0, HDMI 1.x, DVI Signal Support, HDCP 1.x, HDCP 2.2 support etc all complete
SITC of Universal Matrix Switcher with HDMI 2.0 and USB-C connectivity, 2 HDMI, 2 USB-C Inputs and 2 HDMI Outputs with audio out, USB-C input connectivity for 4K Video, Audio, Data, and Power (Video, Audio, Data and Power over a single USB-C connection), Supports HDMI 4K signal formats (4K UHD @60Hz RGB 4:4:4, up to 18 Gbps), Multiple USB 3.1 Gen 1 connectivity for any type of USB devices (Camera, speakerphone, touch monitor, USB-HID devices etc all complete
SITC of HDMI 2.0 Transmitter, Supports HDMI 4K signal formats (4K UHD @60Hz RGB 4:4:4, up to 18 Gbps), Bi-directional PoC remote powering, Extends HDMI 2.0, audio, Ethernet, RS-232 up to 100m over one CATx cable, HDR and Low Latency Dolby Vision support, HDCP 2.3 compliant (transparent pass-through) etc all complete
SITC of HDMI 2.0 Reciever, Supports HDMI 4K signal formats (4K UHD @60Hz RGB 4:4:4, up to 18 Gbps), Bi-directional PoC remote powering, Extends HDMI 2.0, audio, Ethernet, RS-232 up to 100m over one CATx cable, HDR and Low Latency Dolby Vision support, HDCP 2.3 compliant (transparent pass-through) etc all complete
SITC of 8 Inputs and 8 Outputs HDMI 2.0 Compatible Full 4K Matrix Switcher, Supports HDMI 4K signal formats (4K UHD @60Hz RGB 4:4:4, up to 18 Gbps), HDMI 2.0, HDMI 1.4 and DVI 1.0 compliant, HDCP 2.2 and HDCP 1.4 compliant with cross conversion capabilities, HDR and Low Latency Dolby Vision support, Audio de-embedding, Advanced EDID Management, Fully non-blocking switching architecture, Device control via Ethernet (TCP/IP), RS-232 and USB etc all complete
SITC of Digital UHF Wireless Handheld Microphone System, Dynamic, 24 bit Digital Audio, Dynamic Range - 118 dB or better, Frequency Response : 20 to 20,000 Hz, Polar Pattern : Cardioid, Channels – Upto 30 simultaneous Channels per frequency bands, Switching Bandwidth - 42 MHz or better, Frequency Auto Scan Functionality, Range – 300 ft or more, RF Transmitter Output : 10 mW, Should have LAN port for monitoring, Should include rechargeable batteries and charger, Battery Life : 8 hours or more etc all complete
SITC of Digital UHF Wireless Lapel Microphone System, Condenser, 24 bit Digital Audio, Dynamic Range - 118 dB or better, Frequency Response : 20 to 20,000 Hz, Polar Pattern : Omnidirectional, Channels – Upto 30 simultaneous Channels per frequency bands, Switching Bandwidth - 42 MHz or better, Frequency Auto Scan Functionality, Range – 300 ft or more, RF Transmitter Output : 10 mW, Should have LAN port for monitoring, Should include rechargeable batteries and charger, Battery Life : 8 hours
SITC of Antenna Distribution System, 5 Selectable Frequency Ranges, RF Power LED Indicators, cascade ports allow connection to a fifth receiver or a second expander etc all complete
SITC of Passive Wide Band UHF Omnidirectional Antenna, RF Frequency Range 470 to 1100 MHz with mounting etc all complete
SITC of 100-foot coaxial cable offers BNC to BNC connection etc all complete
SITC of Dynamic Vocal Microphone, Polar Pattern: Cardioid (unidirectional), Includes integrated on/off switch, Frequency response: 50 to 15,000 Hz etc all complete
SITC of Dynamic Instrument Microphone, Polar Pattern Cardioid, Frequency Response 40 to 15,000 Hz, Rated impedance is 150 Ω (310 Ω actual) for connection to microphone inputs rated low impedance etc all complete
SITC of Gooseneck Microphone with mute switch, Status indicator, Pre Amp, Frequency Response - 50 to 17,000 Hz, Output Impedance (at 1,000 Hz) - Rated at 150 Ohm (180 Ohm actual), Open Circuit Sensitivity (At 1 kHz) - 33.5 dBV (21.1 mV), Maximum SPL (1kHz at 1% THD, 1 kOhm load) – 124.2 dB with Base moount etc all complete
SITC of Digital Mixer, 32 Mono Mic/Line Inputs, 3 Stereo Inputs, 24 Mix Outputs, 4 Stereo Groups, Up to 11 Monitor Mixes, 2 Stereo Matrix Outs, 4 FX Engines, 4 dedicated FX Sends / Returns, 4 Mute Groups, 4 DCA Groups, AES Digital Out, 32×32 USB Audio Interface, 33 Motor Faders, 7” Touchscreen, 10 Soft Keys, Trim, polarity, HPF, gate, insert, 4-band PEQ, compressor, delay on all Inputs, Insert, 4-band PEQ, 1/3 octave GEQ, compressor, delay on all Outputs, Automatic Mic Mixer, Channel Ducker on all Inputs, Interface for additinal stage box connectivity over Catx, EQ Library presets for a large number of popular and industry standard microphones etc all complete
SITC of 16 XLR Input / 8 XLR Output Stage Box Expander, 48 kHz operation, Compatible with above mixer, Compatible with CAT5e (or higher) cables of up to 100m etc all complete
SITC of Ceiling Array Microphone, Automatic Coverage technology, allow up to eight Automatic Coverage areas, onboard digital signal processing which includes automatic mixing, acoustic echo cancellation, noise reduction, automatic gain control, compression/limiting, delay, and parametric, equalization, Dante and AES67 digital audio networking over a single network cable, RJ-45 connection for audio, control data, and PoE powe, shall be capable of sending and receiving command strings that enable integration with third- party camera control or room control systems. The microphone shall provide enhanced talker localization data that allows camera control systems to be directed to the precise location of an individual talker with mounting arrangement etc all complete
SITC of Left & Right FOH Speaker, Two Way, Trapezoidal, 15-inch, Die cast aluminum frame woofer with a 3.5-inch voice coil, 2.8” compression driver, Power Capacity (Continuous / Peak): 500 W / 2000 W, Frequency Response 55 Hz – 20 kHz, Sensitivity 97 dB (1 W @ 1 m), Coverage Angle 75° conical DMT, Max SPL 130dB, Nominal Impedance 8Ω, Plywood enclousre etc all complete
SITC of Eyebolt kit for suspending loudspeakers (wooden enclosures) with all required accessories etc all complete
SITC of Left & Right Fill Speaker, Two Way, Trapezoidal, 12-inch, Die cast aluminum frame woofer with a 3-inch voice coil, 1.75” compression driver, Power Capacity (Continuous / Peak): 400 W / 1600 W, Frequency Response 64 Hz – 20 kHz, Sensitivity 96 dB (1 W @ 1 m), Coverage Angle 85° conical DMT, Max SPL 128dB, Nominal Impedance 8Ω, Plywood enclousre etc all complete
SITC of Powder coated steel yoke for mounting with all required accessories etc all complete
SITC of Left & Right Back / Front Fill Speaker, Two Way, Trapezoidal, 10-inch, Die cast aluminum frame woofer with a 2.5-inch voice coil, 1.75” compression driver, Power Capacity (Continuous / Peak): 300 W / 1200 W, Frequency Response 68 Hz – 20 kHz, Sensitivity 95 dB (1 W @ 1 m), Coverage Angle 85° conical DMT, Max SPL 126dB, Nominal Impedance 8Ω, Plywood enclousre with all required accessories etc all complete
SITC of Powder coated steel yoke for mounting with all required accessories etc all complete
SITC of Direct Radiation Subwoofer, 18 Inch, Frequency Response 37 Hz to 230 Hz, Power capacity: (Continuous / Peak): 800 W / 3200 W, Sensitivity 98 dB (1 W @ 1 m), Max SPL 133 dB, Nominal Impedance 4Ω, Plywood enclousre with all required accessories etc all complete
SITC of Dual Channel Professional Power Amplifier, Class D, loudspeaker processing built in. Includes high and low-pass filters, 4-band parameteric EQ, limiting, and delay, Output Power per Channel: 800 watts/ch at 8Ω, 1200 watts/ch at 4Ω, total power capacity of 4500 watts, Distortion (typical) 1 kHz at full rated power < 1% THD, Signal to Noise 100 dB, Amplifier and Load Protection Short circuit, open circuit, thermal, RF protection Load protected against DC faults, UL, CE, RoHS/WEEE compliant etc all complete with all required accessories etc all complete
SITC of Stage Monitor Speaker, 12" Compact Powered Loudspeaker, Frequency Response: 50 Hz - 20 kHz, Class D, Power capacity Peak: 800 W (LF), 200 W (HF), Nominal Coverage Angle: 90° Axisymetric, Maximum Rated SPL 126 dB with all required accessories etc all complete
SITC of 16-driver Column Surface-Mount Loudspeaker, Rated Noise Power: 200W, Frequency Range: 90 Hz – 17 kHz, Sensitivity: 89 dB (Narrow) 88 dB (Wide), Coverage (Horizontal x Vertical): 160 x 15 (Narrow) / 30 (Wide), Maximum SPL: 112 / 118 dB (Narrow), 111 / 117 dB (Wide), capable of 70V/100V or 8 ohm bypass loads, UL registered per UL1876, ROHS, CE compliant with all required accessories etc all complete
SITC of 6.5-inch, 2-Way Ceiling Speaker, Rated Power: 60W, Frequency Range: 65 Hz – 20 kHz, Sensitivity: 88 dB, Rated Coverage 135° conical DMT, Maximum continuous SPL 106 dB, Nominal impedance: 8 / 16 Ohm, Transformer taps: 60W / 30W / 15W at 100 / 70V, IP-34 Rated, Low-saturation and low-loss 70/100V transformers with 16Ω bypass, UL and CE Certified with all required accessories etc all complete
SITC of 4 Channel Class-D Amplifier, Power (per channels driven): 200 W at 8 Ω / 4 Ω / 100V / 70V, FlexAmp Technology, Frequency Response: 20 Hz – 20 kHz, Signal to Noise > 103 dB, Input impedance >10k, balanced or unbalanced, User-configurable operating modes, UL, CE, RoHS/WEEE compliant with all required accessories etc all complete
SITC of 120W Commercial Mixer Amplifier with 4 Inputs, Low-Z (4/8 Ohm) and High-Z (70/100 V) operation with switchable high-pass filter, 4 mic/line inputs with individual volume controls, GPI remote volume control using standard RJ-45 connector and Ethernet cable etc all complete
SITC of Fully Integrated Audio, Video and Control Solution, 128 Networked Audio Channel, 24 Channels of analog I/O, including 8 configurable Flex channels, 16 AEC Processor, Up to 32 x 32 Dante audio channels (8 x 8 included), USB AV bridging (16 x 16 audio + Camera Support), Full-featured Control engine (with Feature License), Up to 4x VoIP Instances, External USB audio device host etc all complete
SITC of Audio, Video and Control (AV&C) Processor, 64 x 64 networked audio channels, 8x on-board Flex channels and GPIO, Full-featured Control engine (with feature license), 8 AEC Processors, up to 32 x 32 Dante audio channels (8 x 8 included), USB AV bridging (8 x 8 audio + Camera support), Full-featured Q-SYS Control engine (with optional feature license), External USB audio device host, Up to 2x VoIP instances etc all complete
SITC of Expension Module for RS232 / Communication Port, Gigabit LAN, Four bi-directional RS232 serial ports, Power over Ethernet (PoE) capable etc all complete
SITC of Expension Module for Relay / GPIO Port, Gigabit LAN, Eight (8) logic inputs and eight (8) logic outputs, Power over Ethernet (PoE) capable etc all complete
SITC of 10.2" Apple iPad LED-backlit Multi-Touch display with IPS technology with User Control Interface (UCI) Deployment etc all complete
SITC of 8 Port Managed Switch, 10/100 Mbps, 1000 Mbps, Gigabit Copper etc all complete
SITC of 16 Port Managed Switch, 10/100 Mbps, 1000 Mbps, Gigabit Copper etc all complete
SITC of Wireless Access Point etc all complete
SITC of 1 Meter Premium High Speed HDMI 2.0b Flexy Cable, Bandwidth up to 18Gbps, Up to 4096x2160@60Hz at RGB 4:4:4 video resolution, High Dynamic Range (HDR10), Dolby Vision and Hybrid log–gamma (HLG) video etc all complete
SITC of 2 Meter Premium High Speed HDMI 2.0b Flexy Cable, Bandwidth up to 18Gbps, Up to 4096x2160@60Hz at RGB 4:4:4 video resolution, High Dynamic Range (HDR10), Dolby Vision and Hybrid log–gamma (HLG) video etc all complete
SITC of 5 Meter Premium High Speed HDMI 2.0b Flexy Cable, Bandwidth up to 18Gbps, Up to 4096x2160@60Hz at RGB 4:4:4 video resolution, High Dynamic Range (HDR10), Dolby Vision and Hybrid log–gamma (HLG) video etc all complete
SITC of 7.5 Meter Active Copper HDMI Cable, Data Rate: Up to 18.2Gbps, Colour Depth: Up to 16 bits, Colour Formats: RGB 4:4:4 / Y’CBCR 4:2:2 / Y’CBCR 4:2:0, Consumer Electronic Control (CEC), Auto Lip-Sync Correction, Audio Return Channel (ARC), Enhanced Audio Return Channel (eARC), High Dynamic Range (HDR) etc all complete
SITC of 12.5 Meter Active Copper HDMI Cable, Data Rate: Up to 18.2Gbps, Colour Depth: Up to 16 bits, Colour Formats: RGB 4:4:4 / Y’CBCR 4:2:2 / Y’CBCR 4:2:0, Consumer Electronic Control (CEC), Auto Lip-Sync Correction, Audio Return Channel (ARC), Enhanced Audio Return Channel (eARC), High Dynamic Range (HDR) etc all complete
SITC of 15 Meter Active Copper HDMI Cable, Data Rate: Up to 18.2Gbps, Colour Depth: Up to 16 bits, Colour Formats: RGB 4:4:4 / Y’CBCR 4:2:2 / Y’CBCR 4:2:0, Consumer Electronic Control (CEC), Auto Lip-Sync Correction, Audio Return Channel (ARC), Enhanced Audio Return Channel (eARC), High Dynamic Range (HDR) etc all complete
SITC of 1 Meter USB Full-Featured Type-C cable for USB 3.1 Gen2, 4 Lane Displayport Alt mode (4K60FPS Video and Audio), Supporting peripherals via USB 2.0 up to 480 Mbps (Mouse, Keyboard, Thumb Drive, Speakerphone and Webcam) etc all complete
SITC of 2 Meter USB Full-Featured Type-C cable for USB 3.1 Gen2, 4 Lane Displayport Alt mode (4K60FPS Video and Audio), Supporting peripherals via USB 2.0 up to 480 Mbps (Mouse, Keyboard, Thumb Drive, Speakerphone and Webcam) etc all complete
SITC of 10 Meter USB 3.1 Gen1 SuperSpeed Active Extension Cable TypeA/male to TypeA/female, Supports 4K Webcam, SSD storage, Native USB2/USB1 and USB3 extension, Plug and play compatible with PC, Mac, and Linux etc all complete
SITC of 15 Meter USB 3.1 Gen1 SuperSpeed Active Extension Cable TypeA/male to TypeA/female, Supports 4K Webcam, SSD storage, Native USB2/USB1 and USB3 extension, Plug and play compatible with PC, Mac, and Linux etc all complete
SITC of Microphone Cable, 2 Conductor 22 AWG Tinned Copper, PE Insulation, 85% Tinned Copper Braid Shield, Cotton Braid, PVC Jacket (as per actual) etc all complete
SITC of 2 Conductor 16 AWG Speaker Cable, stranded Bare copper conductors, PVC/Nylon insulation, PVC jacket (as per actual) etc all complete
SITC of 2 Conductor 14 AWG Speaker Cable, stranded Bare copper conductors, PVC/Nylon insulation, PVC jacket (as per actual) etc all complete
SITC of 2 Conductor 12 AWG Speaker Cable, stranded Bare copper conductors, PVC/Nylon insulation, PVC jacket (as per actual) etc all complete
SITC of Category 6A Cable, 4 Pair, S/FTP, PVC jacket (as per actual) etc all complete
SITC of Floor Box, Configurable with removable modules, mainly used for Audio/Video design etc all complete
SITC of Various Cables & Connectors etc all complete
SITC of 16U, Equipment Rack, with Front & Side doors, 4 No Fan Assembly, on Top of the Rack, 4 Caster wheels, 2 no Shelfs to mount the equipments which are not rack mounted, 8X2, 5/6 Amp. Power Distribution Unit, Cable Manager & Sufficient Rack hardwares etc all complete
SITC of 20U, Equipment Rack, with Front & Side doors, 4 No Fan Assembly, on Top of the Rack, 4 Caster wheels, 2 no Shelfs to mount the equipments which are not rack mounted, 8X2, 5/6 Amp. Power Distribution Unit, Cable Manager & Sufficient Rack hardwares etc all complete
SITC of 42U, Equipment Rack, with Front & Side doors, 4 No Fan Assembly, on Top of the Rack, 4 Caster wheels, 2 no Shelfs to mount the equipments which are not rack mounted, 8X2, 5/6 Amp. Power Distribution Unit, Cable Manager & Sufficient Rack hardwares etc all complete
SITC of 150W High Quality LED Parcan Light complete with Lamp source 3200K CCT Colour temperature, CRI & TLCI Values above 95, COB LED source from reputed make (LM80 to be provided), DmX 512 dimming with 3 channel control, Beam Angle of 9˚ / 25˚ / 45˚, Total Power Consumption of 165W, High quality output replacing 1000W Halogen Par, Flicker Free 100% for Tv & Film Cameras , 11.7KHz Refresh Rate, Linear Dimming 0 ~ 100%, Fuse and Internal safety protections, Strobe option Adjustable 1~25 times/Sec Variable, Fixture provided with Yoke of Manual Adjustment, 5 Pin XLR for DmX Black powder coated body, RDM Control options with latest technology (RDM ID to be specified), LM79 Certificates from NABL Acrediated laboratory, Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012, CE Certification compliant to EN60598-1:2015, EN61437-2-13:2014, Brand embosed impact on the light body for genuine product with all required accessories etc all complete
SITC of 300W LED Profile Spot 19 Degree Light complete with 3200K CCT Colour Temperature, COB LED source from reputed make (LM80 to be provided), CRI & TLCI above 95, Strobe option Adjustable 1 ~ 25 times / Sec, 4 Kinds of dimming curves, Black finish housing, Manual Focus with 4 Beam shaping cutters, Efficient and well-designed Lamp reflector, Efficient Copper tube based Heat Sink for Heat Dissipation, Sleek and Unique Designed Light weight body, Fixture provided with Yoke of Manual Adjustment, DmX 512 dimming with 1 or 3 Channel modes, IP20 protection having Lux @ 3 Mtrs above 12040 suitable to illuminate the key presentor or talent on stage. illuminate the key presentor or talent on stage, RDM Control options with latest technology (RDM ID to be specified), LM79 Certificates from NABL Acrediated laboratory, Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012, CE Certification compliant to EN60598-1:2015, EN61437-2-13:2014, Brand embosed impact on the light body for genuine product with all required accessories etc all complete
SITC of 400W LED Blinder Light 30 Degree complete with 3200K CCT 4x100W Chip On Board LED Lamp source, COB LED source from reputed make (LM80 to be provided), DmX 512 dimming with 4 /8 Channel modes, CRI & TLCI Value > 90, Strobe option Adjustable 1 ~ 25 times / Sec Variable, Beam Angle 30 Degree, Total Power Consumption of 420W, 11.7KHz Refresh Rate, In built preset’s for effects, Fuse and Internal safety protections, Active Cooling with Low Noise Fan, 5 Pin XLR for DmX, High quality well designed inbuilt reflector, Flicker Free 100% for Tv & Film Cameras, Black finish housing, IP20 protection, Having Strobe option and smooth dimming, illuminate Stage with uniform light intensity levels, RDM Control options with latest technology (RDM ID to be specified), LM79 Certificates from NABL Acrediated laboratory, Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012, CE Certification compliant to EN60598-1:2015, EN61437-2-13:2014 with all required accessories etc all complete
SITC of 54 x 3W LED Par Light RGBW, Beam Angle 25° complete with LED source from reputed make (LM80 to be provided), RGBW 3W Lamp source x 54 Pcs, DmX 512 dimming with 8 Channel, High Bright Red, Green, Blue, White LED’s Source, Unlimited Color Mixing through DmX, 0 ~ 100% Linear dimming, In built presets for different colors, Strobe Mode 20 times/Sec, Data DmX through 5 Pin XLR’s, 65dB ~ 130dB Sound sensing capacity, Power In and Out Connections, High precision colors, IP20 protection, Powder coated Black finish housing, Having Sound Control & Master Slave Auto Run Mode, Illuminate the Indoor stage with unlimited colour effects, Rigidly built pressure die-casted Aluminium body, RDM Control options with latest technology (RDM ID to be specified), LM79 Certificates from NABL Acrediated laboratory Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012, CE Certification compliant to EN60598-1:2015, EN61437-2-13:2014, Brand embosed impact on the light body for genuine product with all required accessories etc all complete
SITC of 54x3W LED 3200K Par Light Beam Angle 25° complete with , 3200K 3W Lamp source x 54 Pcs , LED source from reputed make (LM80 to be provided) , Having CRI TLCI Values above 95, Flicker Free for high FPS, Smooth fade in and Fade out, High precision steady color, No heat, DmX 512 dimming with 2 Channel, 0 ~ 100%, Powder coated Black finish housing, Rigidly built pressure die-casted Aluminium body, LED Easy view display, Data DmX through 3 / 5 Pin XLR’s, 65dB ~ 130dB Sound sensing capacity, Power In and Out Connections, Total Power Consumption of 180W, Sound Active Mode Control, IP20 protection, RDM Control options with latest technology (RDM ID to be specified), LM79 Certificates from NABL Acrediated laboratory, Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012, CE Certification compliant to EN60598-1:2015, EN61437-2-13:2014, Brand embosed impact on the light body for genuine product with all required accessories etc all complete
SITC of 300W LED Cyclorama Wash Light with LED source from reputed make (LM80 to be provided), 60 Degree or better beam spread, 48 LED Emmitters having RGB Source, Seamless CCT Tuning from 3000K ~ 7000K, R,G,B + WW direct access through knobs for manual operation 10 Presets for CCT Selection, Luxeon LED High Lumens per watt, RGB Colour mixing and presets control, Asymmetric Reflector on LED's, Uniform Spread with RGB LED control, 14+ DmX Channel operation, Barndoor, arrangement for Light spill control, Nuetrick Power loop in and Out, 230V AC Input power along with Fuse protection, No Noise 0 dB operation, RDM Control options with latest technology (RDM ID to be specified), LM79 Certificates from NABL Acrediated laboratory, Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012, CE Certification compliant to EN60598-1:2015, EN61437-2-13:2014, Brand embosed impact on the light body for genuine product with all required accessories etc all complete
SITC of Light fixture mouting clamp , Customized for suspending on fixed bars on stage, Made up of Aluminium Die casted, MS threaded T bolt with yellow passivation finish, Complete with black powder coating matt black finish, Safe working load 150 KG, Suitable to Batten of size 30 OD to 60 OD with all required accessories etc all complete
SITC of Light Fixture dual safety , Chain made up of GI wire rope , Bundled and twisted together , Having load bearing capacity above 200 Kgs, Sleve on the rope. Carabiner Clip with all required accessories etc all complete
SITC of Suspender cum clamps designed made out of MS material, 150mm x 150mm x 5mm MS Base plate, Threaded rod, Black powder coated finish, All the materials under gone through 7 tank process with, various chemical treatment to keep them rust free, Suitable to hold various type grid & other rigging systems with all required accessories etc all complete
SITC of Fixed stage Lighting bar/winch of 15Mtr length constructed with an dual contruction light bar with an Mild Steel 40NB 48 OD black matt finish with an supporting flat patti of height 200mm x 50mm x 6mm thickness for the extra support with 2 holes of 10mm diameter to fix the cable tray on the bar.It shall be hanged from the roof to accommodate various type of stage light fittings. It should hang from the roof with MS anglewhich is suspended from the fish plate of 5mm thickness which is fixed on the rcc roof with 4 anchor fastners of 10mm which can take an total load of 400KG each fastner, Made out of 48mm Outer Dai, 40 Nominal Bore, Material for the light bar shall be of Mild Steel Pipe, Dual Barrel Arrangement, Powder coated with Matt black Texture, Fixing Through Suspenders as per site conditions, Dual Construction and an additional End Caps on the Pipe end shall be there, Light bar Length shall be of customized type as per site condition, Upper pipe of dual construction is used to anchor the bar, lower pipe is effectively used to hang the light fixtures with all required accessories etc all complete
SITC of Fixed FOH Lighting bar/winch of 16Mtr length constructed with an dual contruction light bar with an Mild Steel 40NB 48 OD black matt finish with an supporting flat patti of height 200mm x 50mm x 6mm thickness for the extra support with 2 holes of 10mm diameter to fix the cable tray on the bar.It shall be hanged from the roof to accommodate various type of stage light fittings. It should hang from the roof with MS anglewhich is suspended from the fish plate of 5mm thickness which is fixed on the rcc roof with 4 anchor fastners of 10mm which can take an total load of 400KG each fastner, Made out of 48mm Outer Dai, 40 Nominal Bore, Material for the light bar shall be of Mild Steel Pipe, Dual Barrel Arrangement, Powder coated with Matt black Texture, Fixing Through Suspenders as per site conditions Dual Construction and an additional End Caps on the Pipe end shall be there Light bar Length shall be of customized type as per site condition, Upper pipe of dual construction is used to anchor the bar, lower pipe is effectively used to hang the light fixture with all required accessories etc all complete
SITC of Power Distribution Electrical panel having a Incomer of 100A. Floor mount / rack mount / wall mount, Miniature circuit brakers of single poles shall be fixed of different ratings from 6/10/16/25A as per the lighting fixtures.Wiring inside the module for power, control protection and instrument etc, shall be done with use of 1100 V confirming to IS 694 and IS 8130, All welding slag grounded off and welding pits wiped smoothwith plumber metal.Power panels shall be designed in such a way that the internal space is sufficient for hot air movement, and the electrical component does not attain, temperature more than 40 degree Celsius.Fabricated panel shall be supported with ms angles of size, 25mm x 25mm with an 1.8mm thickness sheet to hold the structure, Nuetral separation made using incomer, Voltmeter, Ammeter display for reading visualization, Individual MCB control for 24 outgoing circuits, RYB Phase indicators internally wired using IS certified wires and cables. Terminal for both incoming and outgoing cable shall be suitable for 1100 volts grade, aluminum / copper conductor PVC insulated and sheathed, armoured cable and shall be suitable for connections. Provided with ivery connectors for the internal terminations and external outgoing connecting points, Custom built with all required accessories etc all complete
SITC of High quality power junction box 4 way made up of MS Sheet metal fabricated housing, Snap fit fixing /15 (1.5mm ) Total Max Rating 10A, 250V A.C, 20˚C to +70˚C Operating Temp Moldings: Nylon, Flammability Rating UL94V-0, Black powder coated, fibre glands of suitable size fitted with Powercon or IEC connector Box 10A, Clamp arrangement for fixing or Raul plug arrangement with all required accessories etc all complete
SITC of High quality power junction box 2 way made up of MS Sheet metal fabricated housing, Snap fit fixing /15 (1.5mm ), Total Max Rating 10A, 250V A.C, 20˚C to +70˚C Operating Temp, Moldings: Nylon, Flammability Rating UL94V-0, Black powder coated, fibre glands of suitable size fitted with Powercon or IEC connector Box 10A, Clamp arrangement for fixing or Raul plug, arrangement for wall/floor fixing with all required accessories etc all complete
SITC of High quality Dimming In junction box 1 way made up of MS Sheet metal fabricated housing, High temperature resistant insulator material, All metal housing offers best overall RF protection & electromagnetic shielding, Black powder coated, fibre glands of suitable size fitted with 5 Pin DmX XLR Male socket, Clamp arrangement for fixing or Raul plug arrangement for wall /floor fixing with all required accessories etc all complete
SITC of High quality Dimming Out junction box 1 way made up of MS Sheet metal fabricated housing High temperature resistant insulator material, All metal housing offers best overall RF protection & electromagnetic shielding, Black powder coated, fibre glands of suitable size fitted with 5 Pin DmX XLR Female socket, Clamp arrangement for fixing or Raul plug arrangement for wall /floor fixing with all required accessories etc all complete
SITC of DmX Loop Junction Box having 1 No. of DmX 5 Pin XLR, Female Socket & 1 No. DmX XLR Male Socket fitted on to a sheet metal fabricated compact Junction box powder coated with matt black texture finish paint, High temperature resistant insulator material, All metal housing offers best overall RF protection & electromagnetic shielding. Clamp arrangement for fixing or Raul plug arrangement for wall /floor fixing with all required accessories etc all complete
SITC of Internal Earthing System with copper bare conductors all along the cable trays, metal parts and Installation Hardwares with all required accessories etc all complete
SITC of Black Powder coated cable trays made out of MS Sheet fabricated for a size of 40 x150 x 40mm & 1.6 mm thickness undergone through 7 tank process with various chemical treatment to keep them rust free with perforation for heat dessipation provided with lid with all required accessories etc all complete
SITC of Black Powder coated cable trays made out of MS Sheet fabricated for a size of 40 x 75 x 40mm & 1.6 mm thickness undergone through 7 tank process with various chemical treatment to keep them rust free with perforation for heat dessipation provided with lid with all required accessories etc all complete
SITC of DmX Male Female Connectors 5 Pin having rubber sheeth protection for Cross connecting DmX wiring connections with all required accessories etc all complete
SITC of DmX Male Termination Connector 5 Pin soldered with required capacity of resistor for signal deframing with all required accessories etc all complete
DmX Touch Screen based controller having 7” Multi touch screen option 2 DmX Outlets 5 Pin XLR’s, 512 Channels each, Optically isolated outputs, 4 Smooth Encoders for control operation of attributes, Backlit keys, 12 Fader Stacks, 600+ Playbacks, 350+ Group saving, 350+ Presets, User defined shape effects, Macro saving options, External Midi timecode options, Internal clock, Shortcut user interfaces, Master fader, Blackout Key under Master fader, Numerical keypad for the light command entry inbuilt embedded within controller, USB interface, Scene saving options, Show saves and load save features, custom built user interface library for fixture files with all required accessories etc all complete
SITC of Opto isolated RDM enabled DmX splitter unit provided with, 8 Isolated outputs, Slow blow safety fuse, 5 Pin XLR for output interface, Dual mode to select 2 universe operation, DmX Input through 5 Pin XLR Connector, Control Protocol RDM and DMX 512, Powder coated compartment finish, Mounting brackets for grid mount with all required accessories etc all complete
SITC of FRLS Copper unarmoured Flexible cable IS694 having 3 Core each of 1.5 Sq mm size (as per acutal) with all required accessories etc all complete
SITC of 5 Core DmX Cable with Sheathed housing on the cable, well designed insulation, low noise suitable to transmet DmX signal (as per acutal) with all required accessories etc all complete
SITC of Suspender cum clamps designed made out of MS material, 150mm x 150mm x 5mm MS Base plate, Threaded rod, Black powder coated finish, All the materials under gone through 7 tank process with various chemical treatment to keep them rust free, Suitable to hold various type grid & other rigging system with all required accessories etc all complete
SITC of C Profile MS Hot rolled strips 3mm thick with Extra U bend used either to create basic supports, Customized 40 x 50mmm, All the materials under gone through 7 tank process with various chemical treatment to keep them rust free, Makes easier to suspend all the stage machinery, Duly powder coated , Matt black texture finish paint with all required accessories etc all complete
SITC of Motor Control Panel with DMX & Manual selectable Motor control panel, cum remote control 2 Way providing power input for motors internally neatly wired with contactors having individual motor control with required Push button, Emergency trip, RYB indicators, Supply Indictor and necessary meters operated wireless smart working functianailty for the motorised lightbars should be there with one neutral & phase connection slots and with 2 vertual load terminals. For each motor unit one each switch units should be installed inside the control panels which can be controlled with our mobiles, touch pads only with the internet connection. Motor control panel duly powder coated with ash grey paint texture finish with all required safety features with all required accessories etc all complete
SITC of Cable Connecting Circuit Boxes for the termination of cables from Electrical panel to the grid level point made out of MS Sheet metal fabricated housing duly powder coated with matt black texture finish paint, fitted with required channels and ivery connectors, necessary glands with all required accessories etc all complete
SITC of FRLS Copper unarmoured Flexible cable IS694 having 7 Core each of 1.5 Sq mm size (as per acutal) with all required accessories etc all complete
SITC of FRLS Copper unarmoured Flexible cable IS694 having 4 Core each of 4 Sq mm size (as per acutal) with all required accessories etc all complete
SITC of High quality Velvet fabric fire retardant treated as per approved colour and make with a gathering of 100% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Main Curtain) Size:20.5Mtr x 7.3 Mtr with all required accessories etc all complete
SITC of Glazzed Cotton fabric fire retardant treated as per approved colour and make with a gathering of 50% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Rear Curtain) Size: 20.5Mtr x 7.3 Mtr with all required accessories etc all complete
SITC of Glazzed Cotton fabric fire retardant treated as per approved colour and make with a gathering of 50% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Frills) Size: 16Mtr x 1.5Mtr with all required accessories etc all complete
SITC of High quality Velvet fabric fire retardant treated as per approved colour and make with a gathering of 100% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Main Valance) Size: 19.5Mtr x 2Mtr with all required accessories etc all complete
SITC of Glazzed Cotton fabric fire retardant treated as per approved colour and make with a gathering of 0% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing. (For Wing) 7.3Mtr x 2Mtr with all required accessories etc all complete
SITC of On Stage Fixed Frill Bar 16Mtrs Length Straight as per the design made out of 40NB 48 OD Mild steel pipe dual barrel, supported to hang the frill, connected with MS Flat duly powder coated with matt black texture finish paint. All the materials under gone through 7 tank process with various chemical treatment to keep them rust free with all required accessories etc all complete
SITC of On Stage Fixed Valance Bar 19.5 Mtrs Length Straight as per the design made out of 40NB 48 OD Mild steel pipe dual barrel, supported to hang the Main Valance of the stage system duly powder coated with matt black texture finish paint. All the materials under gone through 7 tank process with various chemical treatment to keep them rust free with all required accessories etc all complete
SITC of Fixed Wing Structure designed as per site condition for a height approx 7.3Mtr x 2Mtr made up of MS Square tube of 25mm or higher size rested on pivotable trolley on a track for the rotation of the wing. Adjustable floor locking screw jacks with rubber grips. Inverted 4-Wheeler Trolley with Flexi Adaptor Clamp and 360° Rotatable with all required accessories etc all complete
SITC of Motorized DMX operated vertical Main Curtain 20.5 Mtrs as per design, This mechanism shall be provided with 01 Nos. of 1.5 HP, 1440 RPM, 90 B5 frame, 3Ph. 415VAC Motor with Brake for Motor System to lift a load which should be synchronized with Motor Control centre Panel. Winch shall have 3 phase motor with an RPM of 1440,KW (HP) : 1.1(1.5), Frame : 90S, EFF:75.0%, MTG : B5, AMP :2.7Y, Volt:415v, DE BRG : 62052Z, DUTY:S1, FREQ:50Hz, NDE BRG:62052Z, IP:55, AMB:50 degree, Curtain design & mechanism to be such that the curtain & it's mechanism to not take up more than 2.50m space above the proscenium level in its parked/raised position, Curtain wire rope drops shall be at every 1200mm, Open and close limit controller, Drive unit with suitable capacity of motor unit, Wire Rope shall be of GI Wire ropes Min 5mm Dia Undergone through various chemical treatment to keep them rust free, Black texture finish paint. with all required accessories etc all complete
SITC of Motorized DMX operated Rear Curtain 20.5 Mtrs straight, Centre partting as per design. This mechanisam shall be provided with 01 Nos. of 1.5 HP, 1440 RPM, 90 B5 frame, 3Ph. 415VAC Motor with Brake for Motor System to lift a load which should be synchronized with Motor Control centre Panel. Winch shall have 3 phase motor with an RPM of 1440,KW (HP) : 1.1(1.5), Frame : 90S, EFF:75.0%, MTG : B5, AMP :2.7Y, Volt:415v, DE BRG : 62052Z, DUTY:S1, FREQ:50Hz, NDE BRG:62052Z, IP:55, AMB:50 degree., The outer surface temperature is limited.It shall have an Worm Reduction Gearbox with GMRV-90 80:1, 90B5, Single Reduction 7.5:1 to 100:1 and the size shall be 90. It shall have an drive unit base, frame to fix the gear box which contains one shaft, Made up of I Track for complete length, Curtain holding trollies with ball bearing for smoother, noiseless movement consisting of 4 wheeler master trolley and 2 wheeler trolley placed uniformly at specific interval of 200mm /250 mm throughout the track, Overlap of 0.5~0.9 Mtrs. Motor Cable termination box, Trollies uniformly distributed along the track at every 200/250mm with a master trolley, Open and close limit controller, Drive unit with suitable capacity of motor unit, Wire Rope shall be of GI Wire ropes Min 3mm Dai , ndergone through various chemical treatment to keep them rust free, Black texture finish paint, All metal parts are powder coated with all required accessories etc all complete
SITC of Fixed Cyclorama arrangement of 13 Mtrs straight as per design made up of I Track for complete length with Trollies uniformly distributed along the track at every 200/250mm. All metal parts are powder coated with black texture finish paint. All the materials under gone through 7 tank process with various chemical treatment to keep them rust free with all required accessories etc all complete
SITC of Perforated plastic cyclorama screen with perforation on 1side with gathering of 0% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies. Size:13 x 7.3Mtr with all required accessories etc all complete
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5
Supply, installation, testing and commissioning of following minimum capacity 4 way flow VRV / VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower ,multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27DegreeC DB and 19DegreeC WB temperature.
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
High Static Ductable units (minimum 110 pascal external static pressure)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
44 mm O.D. wall thickness ≥ 1.4mm (insulation – 19 mm thick)
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Drain piping :- Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification.
Y joints:- Supply, installation, testing & commissioning of ref nut/Y-joints brass for indoor and outdoor units of suitable size as per requirement,
Supply, Installation, testing and commissioning of factory fabricated GSS Sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc.. As per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63mm sheet
Thickness 0.80mm sheet
Thickness 1.00mm sheet
Thickness 1.25mm sheet
Supply, Installation, testing and commissioning of fabricated at site GSS Sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc.. As per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63mm sheet
Thickness 0.80mm sheet
Thickness 1.00mm sheet
Thickness 1.25mm sheet
Thermal insulation :- Supplying and fixing of following thickness of mat finish closed cell nitrile rubber (class “1”) insulation on existing duct after applying two coats of cold setting adhesive complete as per specifications and as required.
Internal duct acoustic insulation: - Supply, installation, testing and commissioning of internal duct acoustic insulation with open cell structured class "O" fire retardant nitrile rubber with density 140 - 180 kg/m³ and specs as per RISAC chart specification sheet inside of the AHU supply air ducting up to 4 mtr. length from AHU mouth as per the specifications, it should have antimicrobial properties.
Under deck Insulation with 50 mm thick Fire Retardant Extruded Polystyrene having density of 32 Kg / M3 and thermal resistance of 1.78 M2 K / W for examination hall & lecturer hall.
Supplying & fixing of powder coated extruded aluminum Supply air grills with aluminium volume control damper as per specifications.
Supplying & fixing of powder coated extruded aluminum Return air grills with louvers but without volume control damper as per specifications.
Supplying, fixing, testing & commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing, testing & commissioning of return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core.
Supply, installation, testing & commissioning of GI Volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screw linkages, flanges etc.. As per specifications
Flexible connections :- Providing & fixing of flexible canvas connection between indoor unit and duct to avoid the vibration transfer
Controlcable: - Supply and laying, testing & commissioning of following sizes of copper conductor control cables on existing tray including fixing clamps & proper connections to equipment etc. complete as required.
2C x 0.75 sq.mm
Outdoor stand fabrication :- Supply, fabrication and erection of angle/channel/flat iron stand, hanging arrangement for air conditioning machines & ducts etc, back /support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of enamel paint as required as per specification.
Supply, installation, testing & commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per the specifications.
AHU kit: - Supply installation testing and commissioning of AHU kit to integrate with AHUs to various combination of static and CFM requirement shall be connected to IDUs of VRF complete as required as per specification.
SPLIT AC (inverter model) :- Supply, installation, testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable for providing cooling between +/-5 deg. C to 50 deg. C & heating within 0 deg. C to 15 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condensed water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand).
1.0 TR star rating 3 star
1.5 TR star rating 3 star
1.8/2 TR star rating 3 star
Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand).
1.8 TR/2.0 TR single phase
2.4 TR single phase
2.7 / 3.0 TR three phase
3.4 / 3.5 TR three phase
3.8 / 4.0 TR three phase
Supply, installation, testing & commissioning of suction/discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required.
Copper tube 1/4"
Copper tube 3/8"
Copper tube 1/2"
Copper tube 5/8"
Supply, Instalation & testing of Propeller fans as per the tender specifications
Supply, Instalation & testing of Inline type Fresh air fans
Supply, Instalation & testing of Inline type Exhaust air fans
Supply, Instalation & testing of Cabinet type Exhaust air fans as per tender specifications
Supply, Instalation & testing of Cabinet type Fresh air fans as per tender specifications
Supply, Instalation & testing of Cabinet type Exhaust air fans with FILTER as per tender specifications
Supply, installation, testing and comissioining of cabinet type fans for lift well & lift lobby pressurization. Refer tender specifications.
Supply, installation, testing and comissioining of Tube Axial fans for staircase pressurization & smoke extraction system in corridor. Refer tender specifications.
Differential Pressure Transmitters installed for DP feedback for individual shaft for Fan speed maintenance
Smoke sensors for system trip in case of feedback smoke entering the shaft located at two locations per shaft.
Sequential timer for server Room 12hr
Supply, installation, testing & commissioning of factory fabricated Double Skinned Ceiling suspended DX coil TFA Units fabricated out of extruded aluminium section with 0.6mm pre - coated galvanized steel sheet outside & 0.6 mm plain galvanised steel sheet inside with ( 25mm thick Thermal Brake profile ) comparising of DIDW Centrifugal blower, TEFC type blower motor suitable for operation on 415volts +-10%, 50 Hz +- 5% AC Supply ,Rows deep cooling coil made of aluminium finned copper tube with coil section, with fresh air openings, pre- filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% polished stainless steel drain made out of 22 GI Sheet duly insulated complete with motor & belt drive package etc. without face and bypass dampers . The AHU Panels shall be insulated with 25 mm thick & 40 kg/m3 density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to standard specification.With Pre Filter+AHU VRV EXPANSION KIT
TFA 3200 CFM 20 TR 6/8 rows deep with 50 mm static
TFA 2500 CFM 15 TR 6/8 rows deep with 50 mm static
HVAC ELECTRICAL PANELS
MAIN HVAC PANEL Supply, installation, testing and commissioning of the following integrated cubicle type dead front extensible sheet steel control panel, anchoring of panel to foundation. The panel shall be suitable for 415Volts/3Ph/50Hz as per IS 8623, partial type tested assembly.Quoted price shall also include Rubber mats etc. The panel shall have separate compartment for bus bar and cable alleys. The following components and accessories shall be mounted within each control panel as per IS 8623 partial type tested assembly.
1 set of 1600 Amps Electrically operated draw out type 4 pole ACB with 6 NO & 6 NC contacts and complete with the following
0-500 Volts digital type Ammeter with selector switch
0-1600 Amps digital type Ammeter
CTs and selector switches.
Overvoltage tripping mechanism for persistent voltage exceeding 110% of the rated voltage for more than 5 minutes
CT operated over current and earth fault relay(IDMT) with CTs
1600/5A SP 10 protection class VA burden
Phase indicating Lamps with toggle switches and control fuses.
Aluminium Bus bar with heat shrinkable sleeves rated at 1600 Amps for 3 ph and neutral phase. Bus bar shall have maximum current density of 0.8amps/mm2 and the neutral phase bar of not less than 50% capacity
250A FP MCCB - 1 NOS - FOR PRESSURIZATION PANEL
200A FP MCCB - 1 NOS - FOR INDOOR UNIT PANEL
100A FP MCCB - 1 NOS - FOR VENTILATION PANEL
40A FP MCCB - 1 NOS - FOR 10 HP OUTDOOR UNIT
40A FP MCCB - 1 NOS - FOR 12 HP OUTDOOR UNIT
40A FP MCCB - 1 NOS - FOR 14 HP OUTDOOR UNIT
40A FP MCCB - 1 NOS - FOR 16 HP OUTDOOR UNIT
40A FP MCCB - 1 NOS - FOR 18 HP OUTDOOR UNIT
40A FP MCCB - 1 NOS - FOR 20 HP OUTDOOR UNIT
63A FP MCCB - 1 NOS - FOR 22 HP OUTDOOR UNIT
63A FP MCCB - 2 NOS - FOR 24 HP OUTDOOR UNIT
63A FP MCCB - 2 NOS - FOR 26 HP OUTDOOR UNIT
63A FP MCCB - 18 NOS - FOR 28 HP OUTDOOR UNIT
40A FP MCCB - 3 NOS - FOR SPARE
63A FP MCCB - 3 NOS - FOR SPARE
INDOOR UNIT PANEL Supply, installation, testing and commissioning of the following integrated cubicle type dead front extensible sheet steel control panel, anchoring of panel to foundation. The panel shall be suitable for 415Volts/3Ph/50Hz as per IS 8623, partial type tested assembly.Quoted price shall also include Rubber mats etc. The panel shall have separate compartment for bus bar and cable alleys. The following components and accessories shall be mounted within each control panel as per IS 8623 partial type tested assembly.
1 set of 200 Amps FP MCCB
0-500 Volts digital type Ammeter with selector switch
0-200 Amps digital type Ammeter
CTs and selector switches.
Overvoltage tripping mechanism for persistent voltage exceeding 110% of the rated voltage for more than 5 minutes
CT operated over current and earth fault relay(IDMT) with CTs
200/5A SP 10 protection class VA burden
Phase indicating Lamps with toggle switches and control fuses.
Aluminium Bus bar with heat shrinkable sleeves rated at 200 Amps for 3 ph and neutral phase. Bus bar shall have maximum current density of 0.8amps/mm2 and the neutral phase bar of not less than 50% capacity
63A FP MCCB - 11 NOS - FOR INDOOR UNIT
PRESSURIZATION PANEL Supply, installation, testing and commissioning of the following integrated cubicle type dead front extensible sheet steel control panel, anchoring of panel to foundation. The panel shall be suitable for 415Volts/3Ph/50Hz as per IS 8623, partial type tested assembly.Quoted price shall also include Rubber mats etc. The panel shall have separate compartment for bus bar and cable alleys. The following components and accessories shall be mounted within each control panel as per IS 8623 partial type tested assembly.
1 set of 250 Amps FP MCCB
0-500 Volts digital type Ammeter with selector switch
0-250 Amps digital type Ammeter
CTs and selector switches.
Overvoltage tripping mechanism for persistent voltage exceeding 110% of the rated voltage for more than 5 minutes
CT operated over current and earth fault relay(IDMT) with CTs
250/5A SP 10 protection class VA burden
Phase indicating Lamps with toggle switches and control fuses.
Aluminium Bus bar with heat shrinkable sleeves rated at 250 Amps for 3 ph and neutral phase. Bus bar shall have maximum current density of 0.8amps/mm2 and the neutral phase bar of not less than 50% capacity
63A FP MCCB - 11 NOS - FOR LIFT WELL, STAIR CASE & CORRIDOR FAN
40A FP MCCB - 6 NOS - FOR LIFT FAN
VENTILATION PANEL Supply, installation, testing and commissioning of the following integrated cubicle type dead front extensible sheet steel control panel, anchoring of panel to foundation. The panel shall be suitable for 415Volts/3Ph/50Hz as per IS 8623, partial type tested assembly.Quoted price shall also include Rubber mats etc. The panel shall have separate compartment for bus bar and cable alleys. The following components and accessories shall be mounted within each control panel as per IS 8623 partial type tested assembly.
1 set of 100 Amps FP MCCB
0-500 Volts digital type Ammeter with selector switch
0-100 Amps digital type Ammeter
CTs and selector switches.
Overvoltage tripping mechanism for persistent voltage exceeding 110% of the rated voltage for more than 5 minutes
CT operated over current and earth fault relay(IDMT) with CTs
100/5A SP 10 protection class VA burden
Phase indicating Lamps with toggle switches and control fuses.
Aluminium Bus bar with heat shrinkable sleeves rated at 100 Amps for 3 ph and neutral phase. Bus bar shall have maximum current density of 0.8amps/mm2 and the neutral phase bar of not less than 50% capacity
40A FP MCCB - 12 NOS - FOR VENTILATION FAN
Control Panel for Air Handling Units : Supply,installation,testing and commissioning of the following cubicle type openable front ,sheet steel wall mounted control panels sleeve type Al. bus bar including anchoring into the wall.These panels shall be complete in all respects as per the drawings and the specifications.The panel shall include the following accessories :
suitable incoming,MCCBs as per rating given below.
Terminal block for power distribution.
Single Phase Preventor.
Phase indicating lights and indicating lights for ON/TRIP status
Digital type Ammeter and suitable size CT and selector switches.
Time delay relay for automatic restart of AHUs motors.
Auto/Manual stop selector switch shall be provided in each AHU Panel.The same should provide potential free contact for position monitoring to BMS system.
All vfd starters shall have suitable potential free contacts
Wiring for microswitch for stopping the fan when fire dampers closes.
The number of AHU panel shall be as detailed below :
63 TP MCCB as incomer 40 amps TP MCB with 1 No.suitable VFD Starter for AHU fan motor
Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor
3½ core armoured 400 sq. mm.
3½ core armoured 150 sq. mm.
3½ core armoured 120 sq. mm.
4 core armoured 6 sq. mm.
4 core armoured 10 sq. mm.
4 core armoured 16 sq. mm.
769 Dismentelling of exisiting old sructure of District Hospital Building including stacking of all serviceable material such as wooden, iron, grill etc. with proper mainting the MAS/ T&P register and handing over to the concerning auotherity and disposal of non service able material / Malba up to the 30.00 Km distance as directed by the engineer encharge / District administration/ Hospital administration.
Note Other Work which is not defined in the specification but reuired for complition of work and necessary for runnig as hospital building, shall be applicable as per the direction of Engineer in charge and no additional payment shall be made for same
Finishing schedule
S.No Description Intern Boys & Girls Hostel
Foundation & structure As per structural design based on soil investigation. (Primarily with RCC footings, columns, raft etc.).
2 SUPERSTRUCTURE
For multi- storey RCC framed structure RCC frame & walls of autoclaved aerated concrete concrete (AAC) blocks/ modular fly-ash lime bricks
Internal Partition Half brick thick brick masonry with fly-ash lime bricks & Full brick work with modular fly-ash lime bricks
3 DOORS AND WINDOWS a) Frames
i) Door M.S. Tubular frames for doors
ii) Window M.S. Tubular frames for Window
iii) Doors of toilet/bath/ WC Factory made single extruded WPC (Wood Polymer Composite) solid door frame
Bath, WC & toilet door Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter. 30mm thick
Other doors 35 mm thick, Chemically Treated Hard wood commercial ply/ flush door shutters both side commercial ply veneering with vertical grains, cross bands and face veneers on both faces of shutters & decorative high pressure laminated sheet on both side of shutter.
Mummty door Steel door with M.S. sheet 1mm thick, frame of angle iron
c) Window shutters All windows shutters M.S. Tubular shutter with 6mm thick Heat strengthened performance glass with reflective soft coating and other shutter with stainless steel SS-304 grade wire-mesh in place of glazing.
d)Hardware & Fittings Main units Stainless steel SS-304 grade
e) Windows Grill M.S. grill
4 FLOORING, SKIRTING & DADO
a)Flooring Rooms vitrified floor tiles with double charge/ multi charge printing. Size of Tile 600 x 600 mm
Balcony Glazed Vitrified tiles Matt/ Antiskid finish of size 600 x 600 mm
Window sills 15mm thick Granite work (machine cut, table rubbed & mirror polished)
Entrance /Verandah/ Corridor 25 mm thick KOTA stone slab flooring
All Staircase 25 mm thick KOTA stone slab flooring on treads & risers
Toilets/ bathroom/ WC Rectified ceramic glazed floor tiles of size above 300x300mm
Skirting in rooms and other areas 100 to 150 mm high skirting matching the floor material.
Toilets/ bathrooms / WC dado Ceramic glazed size above 200 x 300 mm upto 2100mm height.
5 RAILINGS /PARAPETS INBALCONIES /TERRACE
(a) Railings in balconies Stainless steel railing made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design. SS Grade 304
(b) Railings in Main Staircase / Entrance Stainless steel railing made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design. SS Grade 304
(c) Railings in Staircase M.S railing
(d) Parapet on terrace 250 mm thick masonry in Autoclaved aerated concrete (AAC) blocks /duly plastered on both sides and top.
(a) Internal finishes All walls to be treated with 12mm thick cement plaster, 2 mm thick Putty (one time only) and painted with acrylic premium emulsion (plastic) paint. Satin synthetic enamel paint on all wood works and steel works.
(a) Internal finishes All ceiling to be treated with 6mm thick cement plaster, 2 mm thick Putty (one time only) and painted with acrylic premium emulsion (plastic) paint.
(b) External finishes All walls to be treated with 15mm thick cement plaster, 2 mm thick Putty (one time only) and TEXTURED exterior paint . Satin synthetic enamel paint on all wood works and steel works
(b) External finishes 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali
(a) Terrace floor Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm)
(b) Roof Treatment Grading roof for water proofing treatment with Cement concrete/ Water proofing treatment by applying cement slurry mixed with water proofing cement compound/integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures
Finishing schedule
S.No Description Common Dining
Foundation & structure As per structural design based on soil investigation. (Primarily with RCC footings, columns, raft etc.).
2 SUPERSTRUCTURE
For multi- storey RCC framed structure RCC frame construction & walls of autoclaved aerated concrete concrete (AAC) blocks/ modular fly-ash lime bricks
Internal Partition Half brick thick brick masonry with fly-ash lime bricks & Full brick work with modular fly-ash lime bricks
3 DOORS AND WINDOWS a) Frames
i) Door Powder coated aluminium (minimum thickness of powder coating 50 micron)
ii) Window Pre Fabricated Aluminum window.
iii) Doors of toilet/bath/WC Factory made single extruded WPC (Wood Polymer Composite) solid door frame
i)Dining hall Entrance & Internal door/ Kitchen Patition door Powder coated aluminium Shutter (minimum thickness of powder coating 50 micron) with 6mm thick Heat strengthened performance glass with reflective soft coating.
Bath, WC & toilet door Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter. 30mm thick
Toilet External door 35 mm thick, Chemically Treated Hard wood commercial ply/ flush door shutters both side commercial ply veneering with vertical grains, cross bands and face veneers on both faces of shutters & decorative high pressure laminated sheet on both side of shutter.
Other doors 35 mm thick, Chemically Treated Hard wood commercial ply/ flush door shutters both side commercial ply veneering with vertical grains, cross bands and face veneers on both faces of shutters & decorative high pressure laminated sheet on both side of shutter.
External doors Frameless clear float toughened glass door with glazing
c) Window shutters All windows shutters Pre Fabricated Aluminum window with 6mm thick Heat strengthened performance glass with reflective soft coating and other shutter with stainless steel SS-304 grade wire-mesh in place of glazing.
d)Hardware & Fittings Main units Stainless steel SS-304 grade / SS-316 for glass door
e) Windows Grill M.S. grill
4 FLOORING, SKIRTING & DADO
a)Flooring Dining hall vitrified floor tiles with double charge/ multi charge printing. Size of Tile 600 x 600 mm
Kitchen counter/ Toilet counter/ Window sills 15mm thick Granite work (machine cut, table rubbed & mirror polished)
Entrance/ Verandah/ Corridor/Security 15 mm thick Table rubbed polished Granite stone black
Entrance 15 mm thick Table rubbed polished Granite stone black on treads & risers
Loading/Unloading for kitchen / LPG,Ration& Cold store/ Workers room/ Kitchen/ Clean & washing Utensil/ Pantry/ Passage 25 mm thick KOTA stone slab flooring 3675
Toilets/ bathroom/ WC/Hand wash Rectified ceramic glazed floor tiles of size above 300x300mm
Porch/Ramp Chequerred precast cement concrete tiles 22mm thick
Skirting in rooms and other areas 100 to 150 mm high skirting matching the floor material.
Toilets/ bathroom/ WC/Hand wash dado Ceramic glazed size above 200 x 300 mm upto 2100mm height.
5 RAILINGS /PARAPETS INBALCONIES /TERRACE
(a) Railings in Entrance /Ramp Stainless steel railing made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design. SS Grade 304
(a) Internal finishes All walls to be treated with 12mm thick cement plaster, 2 mm thick Putty (one time only) and painted with acrylic premium emulsion (plastic) paint. Satin synthetic enamel paint on all wood works and steel works.
(a) Internal finishes All ceiling to be treated with 6mm thick cement plaster, 2 mm thick Putty (one time only) and painted with acrylic premium emulsion (plastic) paint.
(b) External finishes All walls to be treated with 15mm thick cement plaster, 2 mm thick Putty (one time only) and TEXTURED exterior paint . Satin synthetic enamel paint on all wood works and steel works
(b) External finishes Structural Glazing
(a) Terrace floor Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm)
(b) Roof Treatment Grading roof for water proofing treatment with Cement concrete/ Water proofing treatment by applying cement slurry mixed with water proofing cement compound/integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures
Finishing schedule
S.No Description Guest House
Foundation & structure As per structural design based on soil investigation. (Primarily with RCC footings, columns, raft etc.).
2 SUPERSTRUCTURE
For multi- storey RCC framed structure RCC frame & walls of autoclaved aerated concrete concrete (AAC) blocks/ modular fly-ash lime bricks
Internal Partition Half brick thick brick masonry with fly-ash lime bricks & Full brick work with modular fly-ash lime bricks
3 DOORS AND WINDOWS a) Frames
i) Door M.S. Tubular frames for doors
ii) Window M.S. Tubular frames for Window
iii) Doors of toilet/bath/ WC Factory made single extruded WPC (Wood Polymer Composite) solid door frame
Doors of toilet/bath/WC Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter. 30mm thick
Other doors 35 mm thick, Chemically Treated Hard wood commercial ply/ flush door shutters both side commercial ply veneering with vertical grains, cross bands and face veneers on both faces of shutters & decorative high pressure laminated sheet on both side of shutter.
Mummty door Steel door with M.S. sheet 1mm thick, frame of angle iron
c) Window shutters All windows shutters M.S. Tubular shutter with 6mm thick Heat strengthened performance glass with reflective soft coating and other shutter with stainless steel SS-304 grade wire-mesh in place of glazing.
d)Hardware & Fittings Main units Stainless steel SS-304 grade/brass mortice latch and lock.
e) Windows Grill M.S. grill
4 FLOORING, SKIRTING & DADO
a)Flooring Rooms/Kitchen /Pantry/ Store/Dress/ Recreational room/ Office/ Caretaker room/ Living room vitrified floor tiles with double charge/ multi charge printing. Size of Tile 600 x 600 mm
Balcony Glazed Vitrified tiles Matt/ Antiskid finish of size 600 x 600 mm
Kitchen counter/ Pantry counter/ Window sills 15mm thick Granite work (machine cut, table rubbed & mirror polished)
Entrance /Corridor/Lobby 15 mm thick Table rubbed polished Granite stone black
Staircase 15 mm thick Table rubbed polished Granite stone black on treads & risers
Toilets/ bathroom/ WC Rectified ceramic glazed floor tiles of size above 300x300mm
Porch/Ramp Chequerred precast cement concrete tiles 22mm thick
Skirting in rooms and other areas 100 to 150 mm high skirting matching the floor material.
Toilets/ bathrooms / WC dado Ceramic glazed size above 200 x 300 mm upto 2100mm height.
5 RAILINGS /PARAPETS INBALCONIES /TERRACE
(a) Railings in balconies Stainless steel railing made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design. SS Grade 304
(b) Railings in Verandah/ Entrance/Ramp /Corridor Stainless steel railing made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design. SS Grade 304
(c) Railings in Staircase M.S railing
(d) Parapet on terrace 250 mm thick masonry in Autoclaved aerated concrete (AAC) blocks /duly plastered on both sides and top.
(a) Internal finishes All walls to be treated with 12mm thick cement plaster, 2 mm thick Putty (one time only) and painted with acrylic premium emulsion (plastic) paint. Satin synthetic enamel paint on all wood works and steel works.
(a) Internal finishes All ceiling to be treated with 6mm thick cement plaster, 2 mm thick Putty (one time only) and painted with acrylic premium emulsion (plastic) paint.
(b) External finishes All walls to be treated with 15mm thick cement plaster, 2 mm thick Putty (one time only) and TEXTURED exterior paint . Satin synthetic enamel paint on all wood works and steel works
(a) Terrace floor Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm)
(b) Roof Treatment Grading roof for water proofing treatment with Cement concrete/ Water proofing treatment by applying cement slurry mixed with water proofing cement compound/integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures
Finishing schedule
S.No Description Sports Facility
Foundation & structure As per structural design based on soil investigation. (Primarily with RCC footings, columns, raft etc.).
2 SUPERSTRUCTURE
For multi- storey RCC framed structure RCC frame construction & walls of autoclaved aerated concrete concrete (AAC) blocks/ modular fly-ash lime bricks
Internal Partition Half brick thick brick masonry with fly-ash lime bricks & Full brick work with modular fly-ash lime bricks
3 DOORS AND WINDOWS a) Frames
i) Door Powder coated aluminium frame (minimum thickness of powder coating 50 micron)
ii) Window Powder coated aluminium frame (minimum thickness of powder coating 50 micron)
iii) Doors of toilet/bath/WC Factory made single extruded WPC (Wood Polymer Composite) solid door frame
Bath, WC & toilet door Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter. 30mm thick
Other doors 35 mm thick, Chemically Treated Hard wood commercial ply/ flush door shutters both side commercial ply veneering with vertical grains, cross bands and face veneers on both faces of shutters & decorative high pressure laminated sheet on both side of shutter.
c) Window shutters All windows shutters Powder coated aluminium Shutter (minimum thickness of powder coating 50 micron) with 6mm thick Heat strengthened performance glass with reflective soft coating and other shutter with stainless steel SS-304 grade wire-mesh in place of glazing.
d)Hardware & Fittings Main units Stainless steel SS-304 grade
e) Windows Grill M.S. grill
4 FLOORING, SKIRTING & DADO
a)Flooring Dressing/ Seating vitrified floor tiles with double charge/ multi charge printing. Size of Tile 600 x 600 mm
Toilet counter/ Window sills 15mm thick Granite work (machine cut, table rubbed & mirror polished)
Entrance / Passage 15 mm thick Table rubbed polished Granite stone black
Entrance 15 mm thick Table rubbed polished Granite stone black on treads & risers
Toilets/ WC Rectified ceramic glazed floor tiles of size above 300x300mm
Skirting in rooms and other areas 100 to 150 mm high skirting matching the floor material.
Toilets/ WC dado Ceramic glazed size above 200 x 300 mm upto 2100mm height.
5 RAILINGS /PARAPETS INBALCONIES /TERRACE
(a) Railings in Entrance Stainless steel railing made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design. SS Grade 304
(a) Internal finishes All walls to be treated with 12mm thick cement plaster, 2 mm thick Putty (one time only) and painted with acrylic premium emulsion (plastic) paint. Satin synthetic enamel paint on all wood works and steel works.
(a) Internal finishes All ceiling to be treated with 6mm thick cement plaster, 2 mm thick Putty (one time only) and painted with acrylic premium emulsion (plastic) paint.
(b) External finishes All walls to be treated with 18mm thick cement plaster, 2 mm thick Putty (one time only) and TEXTURED exterior paint . Satin synthetic enamel paint on all wood works and steel works
(a) Terrace floor Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm)
(b) Roof Treatment Grading roof for water proofing treatment with Cement concrete/ Water proofing treatment by applying cement slurry mixed with water proofing cement compound
Finishing schedule for the Engineering Procurement and construction of 300 bedded district hospital with additionally 30 bedded Trauma Unit at Raigarh
S.No Description Hospital Building
Foundation & structure As per structural design based on soil investigation. (Primarily with RCC footings, columns, raft etc.).
2 SUPERSTRUCTURE
For multi- storey RCC framed structure RCC frame construction & walls of autoclaved aerated concrete concrete (AAC) blocks/ modular fly-ash lime bricks
Internal Partition Half brick thick brick masonry with fly-ash lime bricks & Full brick work with modular fly-ash lime bricks
3 DOORS AND WINDOWS a) Frames
i) Door Powder coated aluminium frame Z -section with minimum thickness of 2mm (minimum thickness of powder coating 50 micron)
ii) Window Powder coated aluminium frame Z -section with minimum thickness of 2mm (minimum thickness of powder coating 50 micron)
iii) Doors of bath/ WC/ JC Factory made single extruded WPC (Wood Polymer Composite) solid door frame
i) Corridor/ Lift lobby door Powder coated aluminium Z -section Shutter with minimum thickness of 2mm (minimum thickness of powder coating 50 micron) with 6mm thick Heat strengthened performance glass with reflective soft coating and 12mm thick particle board
Entrance Frameless clear float toughened glass door with glazing and essential fittings
Doors of bath/ WC/ JC Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter. 30mm thick
Toilet External door 35 mm thick, Chemically Treated Hard wood commercial ply/ flush door shutters both side commercial ply veneering with vertical grains, cross bands and face mica on both faces of shutters & decorative high pressure laminated sheet on both side of shutter.
Internal doors 35 mm thick, Chemically Treated Hard wood commercial ply/ flush door shutters both side commercial ply veneering with vertical grains, cross bands and face mica on both faces of shutters & decorative high pressure laminated sheet on both side of shutter.
Mummty door Steel door with M.S. sheet 1mm thick, frame of angle iron
External (Emergency exit ) Door Collapsible steel shutters with Angle iron frame and vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer ,Aluminium frame door & shutter with half Glass & half particle board (main section with minimum 1.5mm thickness)
Fire Door with Frame & all Fittings fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²)suitable for fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. which also includes SS Ball Bearing Hinges of size 100 x 89 x 3mm complete with SS Screws of approved Make ( 4 Nos per panel ),approved Make Panic Bar on Double Leaf for Exit Locations . , S.S. 316 Grade Mortice Handle Ø22mm with euro profile escutcheons [Finish : Satin] [Mechanically BSEN 1906 : 2010 Certified] AND Brand Lock Body - 9'' [With Stainless Steel main and strike plate] [Fire Rated – BSEN 1634 : 1 : 2000 Certified]
c) Window shutters All windows shutters Pre Fabricated Aluminum Z -section Shutter with three panels minimum thickness of 2mm window with 2 panels 6mm thick Heat strengthened performance glass with reflective soft coating and oner shutter with stainless steel SS-304 grade wire-mesh in place of glazing.
d)Hardware & Fittings Main units Stainless steel SS-304 grade/brass mortice Lock ,latch , tower bolt, Automatic Door clouser & door stopper etc (as per relevant specification)
e) Windows Grill M.S. grill
4 FLOORING, SKIRTING & DADO
Basement 62 mm thick cement concrete flooring with concrete hardener topping
Main Staircase 15 mm thick Table rubbed polished Granite stone treads & risers
Stores/Kitchen/Pharmacy Store 15 mm thick Table rubbed polished Granite stone treads & risers
Fire Staircase 15 mm thick Table rubbed polished Granite stone treads & risers
All Ramp Chequerred precast cement concrete tiles 22mm thick
Skirting in rooms and other areas 100 to 150 mm high skirting matching the floor material.
Lift Wall dado 15mm thick Granite work (machine cut, table rubbed & mirror polished) for wall lining upto full height.
Rediology /Path lab/Chimotharpy/OPD 's/Physiotharapy/Mother & New Born/Day Care /Service Area/M-Ward/F-Ward/Private Ward/ NRC/Burn Ward Tranning Hall/Blood Bank/Admin Area /Lab/Examibation Hall / Dietroy & Laundary/Trama Unit/Visitors /cafeteria/Semi open Sitting/Watting Hall// HOD/PA/ Pantry vitrified floor tiles with double charge/ multi charge printing. Size of Tile 1200 x 600 mm
Electrical room/ Fire Room /Server room/ Machine Room /Gas plant /Bio Medical Waste 62 mm thick cement concrete flooring with concrete hardener topping & rubber matting at top
Kitchen counter/ Toilet counter/ Pantry/ Window sills 15mm thick Granite work (machine cut, table rubbed & mirror polished)
Entrance/ Entrance lobby/ Entrance plaza/ Midside Entrance/ Porch 15 mm thick Table rubbed polished Granite stone black
Corridor/ Toilet front/ Lift lobby/ Lobby/ Passage areas / ICU / MICU /NICU /PICU /SICU /GICU / ICCU /SNCU / ORTHO ICU /CASUALTY WARD / Post opreative ICU/OT Complex except OT Room /Receptions/MRI/CT/USG/X-Ray /CSSD 15 mm thick Table rubbed polished Granite stone black
Toilets/ bathroom/ WC Rectified ceramic glazed floor tiles of size above 600x600mm
Main entry Porch 15 mm thick Table rubbed polished Granite stone With Sand blasting at necessary area
All Ramp Chequerred precast cement concrete tiles 22mm thick
Skirting in rooms and other areas 100 to 150 mm high skirting matching the floor material.
Toilets/ bathrooms / WC dado Rectified ceramic glazed floor tiles of size above 600x600mm
Lift Wall dado 15mm thick Granite work (machine cut, table rubbed & mirror polished) for wall lining upto full height.
Lobby /corridor /passage dado vitrified floor tiles with double charge/ multi charge printing. Size of Tile 1200 x 600 mm upto 1.8 m height
Audiomertic Room 25mm wooden planking ,tongued and grooved in flooring including fixing with iron screws completed Second class teak wood including polishing ( top of it synthetic matt to be provided)
5 RAILINGS /PARAPETS INBALCONIES /TERRACE
(a) Railings in Entrance/ Ramp/ Entrance plaza Stainless steel railing made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design. SS Grade 304 with toughend glass with fittings
(b) Railings in Staircase with lift Stainless steel railing made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design. SS Grade 304
(c) Railings in Fire Staircase M.S railing
d) Railing in Corridor /Passage/Ramp etc. Stainless steel railing made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design. (Hand Rail)
(b) Parapet on terrace 250 mm thick masonry in Autoclaved aerated concrete (AAC) blocks /duly plastered on both sides and top. Up to 1000mm height
(a) Internal finishes All walls to be treated with 12mm thick cement plaster, 2 mm thickness to make surface even and smooth and painted with acrylic premium emulsion (plastic) paint Satin synthetic enamel paint on all wood works and steel works with 7 year warrenty.
All ceiling to be treated with 6mm thick cement plaster, 2 mm thickness to make surface even and smooth and painted with acrylic premium emulsion (plastic) paint.
Gypsum board false ceiling with 2 mm thickness to make surface even and smooth and painted with acrylic premium emulsion (plastic) paint . (only in hall /living room/ Bedrooms etc) , PVC flase celing at all other essential area as per reqired
(b) External finishes All walls to be treated with 18mm thick cement plaster, 2 mm thick Putty in all area with scartching in some areas for texture effect and PREMIUM HEAVY DUTY Glossy or Matt Finish Exterior Emulsion paint . Satin synthetic enamel paint on all wood works and steel works
Structural Glazing/ Sand Stone cladding/ GRC jali/ Terracatta/ACP/HPL
7 OT Room 2.1 Modular Pre- Fabricated Operation Theatres 2.1.1 Walls & Ceiling for Operating Area - ( European CE/UL Listed) Bidder must submit third party CE certification. Self attested certificate not valid. The FRAMEWORK should be made of upright ledgers and profiles entirely made of a galvanized steel sheet with a thickness of 1.5mm. They should folded structural steels with a suitable section for the loads. The structure components should be joined together by means of coupling systems in order to create a solid reticular frame, able to support different infill panels whose weight is up to 8 Kg/sq mtr the "Z" upright forms the vertical part of the frame and should be equipped with proper drilling of 32mm ( height partial drilling) suitable for the panel coupling without suing screws between the prights and edges of the panel there is a suitable PVC adhesive seal with a thickness firm of 3mm to ensure air and dust sealing. At the lower end of the upright an adjustment foot should allow the easy leveling of the structure and, the necessary compression of the anchorage between ceiling and floor.
The ledgers should the elements that constitute the basic module of the structure. They should be inserted on the proper hooks by pressure between two uprights, Moreover some "U" profiles , to be placed in horizontal position on the upper and lower part of this structure, constitute its extension with a depth of 64mm together with the metal panels with a thickness of 18mm and the PVC adhesive seal. The structure can be provided with stiffening ledgers or profiles for sliding door fixing and other accessories according to needs. Total thickness of the partition wall : 100mm Skin PANELS (double walll side-partition wall 2 sides): Module skin panels should have a height exceeding 3 mtrs up to a maximum of 3.5m from the floor and a width that should vary from a minimum of 280mm to a maximum of 1200mm"they can be made of different types of finishing; using solid surface material The panels should be made of solid surface material thick 3mm backed by structural panel thick 15mm consisting of a trapezoidal aluminium corrugated core glued between two flat of aluminium sheet.
The Solid Mineral Surface (SMS) material should be dent free antibacterial & fire resistant. The Solid Mineral Surface (SMS) should not require any paint & should have in built antibacterial properties. The material should be manufactured for about two third with aluminium hydroxide and a third with acrylic resin and natural pigments. The aluminium hydroxide should give the product a particular strength and the quality of the acrylic resin should ensure cleanliness, water resistance and colour stability over time. The material should have antibacterial activity(% reduction>99%). On the inner sides of the panels there should slotted holes for their anchorage to the support hooks fixed to the structure uprights, This fastening system should allows obtaining all the following results: The panel should be self centering with consequent joint alignments between panel and panel, ensuring aesthetic balance. The connection between hook and panel should be designed so that the panel, due to its weight, is compressed against the PVC seals coating the entire structure helping to reduce noise transmission. The fixing system of the panels should ensures that there is no accidental breakaway of the panel, even If it is subjected to stress for more safety and stability:
The connection system should allow disassembling and assembling each panel without moving the others near it. Its flexibility the partition wall should satisfy all the inspection and /or the maintenance needs required by modern workplaces (for example electrical installations, hydraulic installations, medical gases etc.) all the panels can be removed over their entire length and on both sides. The lower part of the panel should be equipped with a profile prepared for the laying and the coupling of the horizontal skirtings that need to reenter with the respect to the panel. The inner angles (which are at 90 degree) in operating rooms or in similar environments should made up of a panel without interruption of continuity that covers the angular area of the wall. The panel should characterized by a double specular folding at 135 degree ( or variable folding according to the requirements). All the panels should be drilled according to specific needs (ex ventilation grids of the room) The panels should be perfectly sealed together by means of thermoplastic rubber gaskets inserted by pressure and free of projections.
Properties & Features of Solid Mineral Surface Material . • Density g/cm3 1,7 • Hardness (Barcol) 60 • Water Absorption % 0,023 • Heat Expansion (1x 10"in/in"/F) 2,1 • Ignition Test 38 • Tensile Strength, psi 6500 • Elongation At Yield % 0,2 • Flexural Strength, 8ft;o,Sib 720-79000 • Water Resistance, g/1000cycl Unbreakable • Luster Stable Resistance 0,05 • High Temperature Resistance Uninfluential • Boiling Water Resistance Uninfluential • Stain Resistance Uninfluential • Chemical Resistance Uninfluential
2.1.2 Ceiling for Operating Room (European CE/UL Listed) Bidder must submit third party CE certification. Self attested certificate not valid. The hermetic suspended ceiling should be a loading structure in heavy gauge material forming the grid on which the ceiling panels (made of antibacterial painted steel (Imported). The modular grid, which can be 600 x 600 mm, or variable, allows the integration of sealed lighting fixtures, air anemostats and /or various service units. The variable module grid should make it possible to adapt the size of the ceiling module to match the equipment to be mounted. It should also allow the use of different module sizes within the same room. The grid should be formed of loading profiles, suspended from the ceiling slab, to which the crossbarprofiles are secured by means of rigid mechanical couplings. The thus formed grid should be rigid and remains perfectly stable during all the subsequent site operations. The suspended ceiling should be hermetically sealed by means of silicon gasket application. The function of silicon sealing should be that of assuring an airtight environment in the room and eliminating cervices in which dust could accumulate. The gaskets to be made of non toxic silicon in compliance with regulations applicable to clean rooms.
2.1.3 Planar Ceiling / Laminar Air Flow (Plenum box- Air Diffuser) The Ceiling Filtration System will be designed to ensure homogenous low turbulence. Unidirectional laminar flow of sterile air. The Laminar flow system will comprise of thick extruded aluminum profiles frame and sealed gasket. The filters installed in the plenum will be suitable for application for laminar flow and clean rooms. These filters will meet following specification. • EN 1822 class : H14 • MPPS average efficiency:> 99.995% • 3 Micron DOP efficiency> 99.997% • Pressure drop : 600 pa(max) • Maximum Operating Temp: 60 degree Celsius • Maximum RH : 90 %. • Others: • Protective grids: White epoxy painted micro drawn grid • Separators: Continuous thermo plastic chord • Sealant: Polyurethane • Gasket : One piece polyurethane Efficiency test : Filters individually tested and certified (Agency has to submit test certificate for the filtersfrom original manufacturer along with its supply). Filter will be according to ULPACAT test as per EN 10204. Filter frames and top plenum will be made of AISI- 304 Stainless steel/ Aluminium . The filtration will have flow equalizer for uniform & constant air distribution over the whole surface. The high quality Diffuser will secure the unidirectional airflow according to EN ISO 14644. It will have low noise recirculation systems in compliance with noise levels of 45 to 48 db. Air and Light diffuser made out of two layer of mono filament precision woven polyester for the plan air ceiling to proved Laminar flow. Frame will be rigid frame system and made out of AISI-304 Stainless steel/Aluminium which enables the perfect integration of the OT ceiling with surrounding installations. The OT lighting will be integrated into a frame system which ensures its air sealed integration with the OT ceiling.
The frame system will allow the seamless and air-sealed coverage of all gaps among the various installations and OT ceiling. The Ceiling system will be equipped with "H" class HEPA filters with different performances according to their position in the ceiling to achieve different flow velocities. The filtration ceiling system will have flow equalizer to achieve uniform & constant air distribution over the whole surface. It will also have connection for surgical lamp to be fitted in place of any filter. The technology must avoid turbulences which may draw germs from the non-sterile area in the operating field. The complete filtration ceiling system will be factory assembled. Perfect tightness will be guaranteed by a liquid seal between filters and holding structure enabling no bypass of Mini Pleat filters. A written confirmation from the original product catalogue is required. Laminar air flow system and mini Pleat HEPA Filters will meet relevant European/ US standards Testing & maintenance of air quality with periodic replacements of Mini Pleat HEPA filters will be done at least once in 6 months or earlier if required. The supplier will provide test certificate for HEPA filter and laminar air flow systems from the original manufactures Modular OTs will be constructed considering all stipulated requirements of Air management system etc. Efficiency test : Filters individually tested and certified (we will submit test certificate for the filters from original manufacturer along with its supply).
2.1.4 Double peripheral lights- (cladding type OT) Six sets of double peripheral OT lights each set having two lights will be provided with stepped finish aluminium reflector and will be of A class for use in clean room application. The peripheral light diffusers will be constructed from opal prismatic diffuser material in aluminium frames. Light will be generated from high frequency electronic ballast's complete with colour corrected fluorescent tubes. The ceiling will incorporate supports to secure it to the main structural frame of the modular operating theatre. The laminar flow ceiling will be able to provide integrated lamp support system, ease of maintenance and long life system. Control equipment for the peripheral lighting will be provided in the theatre control panel to allow independent control of the lighting levels by the surgical team. The operation procedures can never be affected by shadows, shimmering lights and dazzling eyes. This has been achieved by the lighting system with sufficient illumination level at the wound site and to provide flicker less design lighting control system. Controls for the peripheral lighting will be provided in the theatre control panel to allow independent control of the lighting levels by the surgical team
2.1.5 Touch Screen Surgeon's Control Panel with Separate Distribution Board- European CE/UL Listed The Control panel will be Touch Screen size not less than 19" Medical Grade , can be configured to incorporate all the services that Operation Theatre staff required. The connection between the surgeon control panel and the distribution board will be by a multiplexed system, providing a PWM signal on a two- core cable. The panel will contain 6 services Tiles as follows: • Time day clock • Time Elapsed Clock • Temperature & Humidity Indicator • General/peripheral Lighting control • Medical Gas Alarm Panel- upto 6 gases • Room Pressure Time Day Clock will be digital type and clocks have high brightness characters, not less than 30mm in height. Time Elapsed Day Clock will be digital type and clocks have high brightness characters, not less than 30mm in height. Temperature Indicator will indicate the theatre temperature will be connected to the local pressure switches of Air-Conditioning system. Indicator will be digital type have high brightness characters, not less than 30mm in height. General Lighting System incorporates all the necessary controls of the lighting system inside the theatre. The medical gas alarm will indicate High and Low gas pressure for each gas service present in the operating theatre and will have an audible buzzer with mute facility. The medical gas alarms will be connected to local pressure switches located downstream of the last isolation valves. A Hand Free Set Telephone system incorporated in the panel with memory type card. All high voltage equipment is installed in a separate enclosure. The remote cabinet will house the operating lamp transformers, mains failure relays, electrical distribution equipment and circuit protection equipment for all circuits within the operating theatre. All internal wiring will terminate in connectors with screw and clamp spring connections of the Clip-on type mounted, on a DIN rail and labeled with indelible proprietary labels. Individual fuses or miniature circuit breakers will protect all internal circuits. All internal wires will be marked with plastic ferrule type cable markers, for ease of identification
2.1.6 X-ray Viewing Screen- (cladding type OT) The theatre will be equipped with a 2-plate X-Ray viewing screen. It will be designed to provide flicker free luminance for the film viewing purpose. It is installed flushed with the theatre wall for hygienic and ease of cleaning purpose. The X-Ray viewing screen is designed for the purpose of front access. The X-Ray viewing screen will be illuminated by 4 pieces of high frequency fluorescent lamps and the dimming will controlled by the usage of dimming ballast with Philips make rotary control. The diffuser is able to diffuse the light evenly and to provide enough luminance for film viewing. It is made of high quality opaque acrylic sheet. The film is held firmly by using spring-loaded clips for ease of mounting and demounting. The body is built by using electrolyzed steel with powder coated to BS standards. 2.1.7 Static dissipative Flooring (Tile Form)-(cladding type OT) The floor finish in the operating room will be 3mm Static dissipative PVC tiles, laid on a semi conductive adhesive base. The floor finish will terminate at the room perimeter passing over a concealed cove former and continuing up the wall for 100mm. Flooring will fulfill EN 649 of US requirements. It will have chemical resistance as per EN 423. It will have electrical resistance conforming to EN 1081/IEC 61340. All joints will be welded and the plastic wall finish will overlap the floor caving by 25mm, to provide a continuous sealed surface. A floor screed will be provided, flat to within a tolerance of+/- 3mm over any 3-metre area. Onto this sub floor, a self-leveling compound will be laid prior to laying of the floor finish. The self-leveling compound will be of the type that does not promote bacteriological growth. Copper grounding strips (0.05mm thick, 50mm width) will be laid flat on the floor in the conductive adhesive and connect to copper wire of grounding
2.1.8 Hatch Box A Hatch of 600mm x 600mm size should be provided in the Operation Theatre as specified in the scope of the work to remove waste materials from the Operation Theatre to Dirty linen Area just adjacent to Operation Theatre. Each Hatch should be equipped with two doors and the door should be operated electronically. The Hatch should be designed in such a way that only one door should be opened at one time. The UV light should be so installed that it is kept on while both the doors are closed, this UV light has to be automatically turned off in case of opening of either of the doors. There should be indicators on both sides of the OT so that the door open/close status can be monitored from both ends. Hatch Box should be manufactured from Stainless Steel (Grade 304). 2.1.9 Scrub Station- (Cladding Type OT) The scrub station will be equipped with 2 bay scrub stations. The scrub station will be made of high grade stainless steel 304 with stain polish finish and wired to the current IEE regulations & BS 7971. The scrub stations control system will be based on advanced microprocessor. The scrub station will be sensor-activated 24VAC. The scrub station will be provided with user selectable time out control. The supply will not be interrupted in case of power failure or maintenance. The station will be equipped with thermostatic mixing valve to control the temperature of hot/cold water supply. The washing faucet will be made of Chrome plated brass hand. 2.1.10 Automatic Sliding Door The main door will be of Single Flap with frame size 1800mm wide x 2100mm height. The second door will be of Single Flap with frame size 1000mm wide x 2100mm height. This should be a hermetically sealed, single sliding door (Standard Size: 2.1 m x 1.8m/2.1xl.0m) The controller should be capable of being operated by elbow switches/foot switches as well as touch Less sensor. The track should be of stainless steel/Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement. The door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the stainless steel/Aluminium track to enable smooth and noiseless movement. Opening and closing of the door should be microprocessor controlled electromechanical movement. Door opening handle should be strong and sturdy. Material should be of 55 (gloss finish). Should be provided with high quality cylindrical lock. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential). Air tightness 99.99% at a pressure of 100Pa. The finished floor on either side of the door should be perfectly level (maximum permissible difference +1 mm). The overall thickness of the finished door should be 55 to 60mm. The inner part of the door should be filled with CFC free polyurethane foam thickness of 48mm or nearby. (Sealed airtight to prevent further ingress of any microbial organism). The door and controls should comply with IEE regulation. All motors used should be DC brushless motors with essential isolation from mains. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed. Door movement should have minimum noise. The starting time after receiving the signal should be adjustable between 0.5 to 20 seconds. The door controller should be CE marked. Test certificate for hermetically sealed door frame (factory test certificate) should be enclosed with the pre dispatch documents.
2.1.11 LED light-Double Dome European CE & FDA/UL listed Should have the following Features: • Two Major Dome/light head • Single Colour Pure White LED's, Reflector based LED Technology Arrangement of LED in such a way that Shadow Free/Deep cavity illumination is achieved. Special design to maximize the field of illumination and optimized illumination depth should have good laminar flow properties Easy and less time consuming service access of electronics on the light head dome surface. Aluminium Housing for better heat management. ESG safety glass for simple and fast disinfection process 360 deg rotation of domes/light heads/arms for unlimited positioning of light heads MIS Lightning Feature on domes Technical Data of Light Heads: Major (2) • Central Illumination Ec (1mt) 160,000 lux • Intensity Range (Lux) 30%-100% • Life time of light source (h) >/= 50,000 • Light Field Diameter (mm) 180-300 • Depth of Field L1+L2 (mm) >/= 850 • CRI (Raj >/=96 • R9 >/=96 • Colour Temp(K) >/=4500 • Rated Power Output less or equal to 65W at 24V DC • Light Head Power Consumption 200 VA+/- 10% • Radiant Energy around 3,4mW/m21x • Temp increase< 1deg • Power Supply-Primary Voltage(V AC) 90-240 • Rotation 360 deg • Operating Range>/= 1700 mm • Adjustment of the spring arm >/ = 1175 mm • Approxwt of each LH </= 18kg • HD Camera PAL for OT Ceiling Light: • for displaying real time images during surgery Features: Centrally mounted in the light head Touch screen Surface Controls Glass Surface for hygiene requirements • Technical Data: • Image Device Sensor: 1/3" • Video standards: Full HD 1920x1080 • Pixels: 20,00,000 • Video outputs: lx Y/Pb/Pr,1x DVI, 2x HD SDI • LAN, RS232, RS485 • Zoom: 10 x optical zoom • 12x digital Electronic • Minimum Illumination: 12 Lux • Signal to Noise Ratio: >50dB • Minimum Working distance: 10mm- wide end • 800 -tele-end • Image rotation: Via OP lighting, 360 deg • Power connection: Yes • Image stabilizer: Auto, manual • Focus: Auto, manual • Iris: Auto, manual • White balance: Auto, manual 2.1.12 Pressure Relief Damper Pressure Relief Dampers will be provided in each room to prevent cross contamination of air from clean and dirty areas. Suitably sized air pressure relief damper will be strategically placed, enabling differential room pressure to be maintained and ensure that when doors are opened between clean and dirty area. Counter-weight balancing system will be provided in the PRD to maintain positive pressure inside the operation room. Air pressure stabilizers will have unique capability of controlling differential pressure to close tolerance. The PRD will remain closed at pressure below the set pressure and will open fully at pressure only fractionally above the threshold pressure. The body will be epoxy powder coated as per standard BS colors. First class electrolyzed steel plate will be used for body and with high grade SS304 Stainless Steel for bladders.
2.1.13 Ceilling Arm Pendent A Single Arm Anesthesia Pendent - CE marked with four digit no Imported Multimovement Pendent is a new design motorized Single arm (1000mm) with up & down movement of 515 mm and load carrying capacity of 80 to 100 kg. The arm can be rotated upto 330º- 340ºwith adjustable stopper. An extremely quite electric motor reduces noise to a minimum, dampened stoppers and very low hand forces for horizontal movements contribute to an ergonomically optimised workplace. The newly developed pneumatic brake system can be adapted to various safety requirements and construction facilities. Modern and very quite, high performance motors as well special spindles are used to realise precise & steady movement. As a safety feature the motor is equipped with an over load protection. The large interior cross section for supply lines offers completely new applications with 120 mm diameter. The stoppers are infinitely variable from 0-330º-340º Service head is provided with the modular design. Service head is designed to host , Base, Gas Module, Electric Module and shelves . Upto 8 Gas outlets & 10 Electrical switches. Racks & shelves are provided to mount the equipments like monitor etc. The total length of the manager is 600mm. Anesthesia pendent will have 1arms with shelves as per following details:
• Horizontal arm system – 1 No. • Weight carrying capacity - 80-100 kg • 5/15 Amp. Electrical sockets without switches - 8 to 10 Nos. • Shelfs with side rails - 2 Nos. • Provision to fix Gas outlets(i.e.) Oxygen- 2, Vaccum- 2, Air 4 bar-1, Air 7 bar-1, N2O -1 & WAGD-1 no. • Gas interface set for interface plate – 1 No. • Ceiling mounting system for interin ceiling upto 1000 – 1 No. • Interface plate with electrical fittings – 1 No. • Ceiling cover for interin ceiling – 1 No. B Double Arm Surgeon Pendent - CE marked with four digit no Imported Multi movement Pendent of double arm (900 mm+600 mm) with up & down movement carrying load capacity of minimum 100 kg. The arm will be rotatable upto 330º- 340ºwith adjustable stopper. The pneumatic brake system will be adaptable to various safety requirements and construction facilities. The interior cross section for supply lines will be of minimum 120 mm diameter. The stoppers will be infinitely variable from 0-330º-340º Service head will be of modular design , Service head will designed to host, Base, Gas Module, Electric Module and shelves . Will have upto 8 Gas outlets & 10 Electrical switches. Racks & shelves are provided to mount the surgical equipments& monitor . Surgeon pendent will have 2 arms with shelves and will include following : • Horizontal arm system – 2 Nos. • Weight carrying capacity min - 100 kg • 5/15 Amp. Electrical sockets without switches - 8 to 10 Nos. • Shelfs with side rails - 2 Nos. • Provision to fix Gas outlets(i.e.) Oxygen- 2, Vaccum- 2, Air 4 bar-1, Air 7 bar-1, N2O -1 • Gas interface set for interface plate – 1 no. • Ceiling mounting system for interin ceiling upto 1000 – 1 no. • Interface plate with electrical fittings – 1 no. • Ceiling cover for interin ceiling – 1 no.
8 Audiomertic Room Use Acoutisal Tile (in celing & Wall) and make the room noise free
Ramp front 16 mm thick bevelled/ tegular edged mineral fibre With 8 mm thick fully perforated calcium silicate board
Electrical room/Stores/ Fire room/ Server room/Skill lab GI Metal Ceiling Lay in perforated Tegular edge With 12.5mm thick tapered edge gypsum moisture resistant board.
Corridor/ Toilet front/ Lift lobby/ Lobby/ Passage areas / ICU / MICU /NICU /PICU /SICU /GICU / ICCU /SNCU / ORTHO ICU /CASUALTY WARD / Post opreative ICU/OT Complex except OT Room /Receptions/MRI/CT/USG/X-Ray /CSSD 16 mm thick bevelled/ tegular edged mineral fibre With 8 mm thick fully perforated calcium silicate board Gypsum board false ceiling 12mm thickness as per design
OPD 's/Teaching room/labs/ HOD/PA/ Pantry/ Tutor & Demonstrator/ Staff room/Cafeteria/council Hall/Purchase section/ Financial office/ General office/Medical Supritendent office/ Photocopy/Red cross medical/PM jan suvidha kendra/Police room/Casualty OPD/Triage/Pharmacy & dispensing area/EPBAX Room/Driver room/Nursing suptt ofice/IT cell/Child care center/Injection Room/Canteen/ATM/Treatment room/Collection center / biochemistry /patology /Microbiology / Blood Bank/Doctor room/Board room / Labour Room / Labour Ward / Pre ecclampisa / Trauma Unit / Burn Unit / Pain Clinic/ Genreal ward / private ward /semi private ward /Telemedicne 8mm thick Calcium Silicate Board With 12.5mm thick tapered edge gypsum moisture resistant board.Gypsum board false ceiling 12mm thickness as per design
Roof Treatment Providing Water proofing treatment over Roof, Wall, Chhajjas, Balcony with Diamond Shield and Sealer coat
11 Electrical Works As per approved drawings & technical specification and all fixtures as per approved make
12 Sanitary works As per approved drawings & technical specification and all fixtures as per approved make
Price Bid Sheet For The Construction of Planning, Designing, Engineering, Procurement and Construction (EPC Mode-1) including one year of operation and maintenance of services of 300 Bedded District Hospital Building with 30 Bedded Trauma Care Unit (Up Gradation of 100 Bedded District Hospital) and Allied infrastructure development work at Raigarh, District Raigarh, Chhattisgarh
PRICE BID SHEET FOR THE CONSTRUCTION OF 300 BEDDED WITH 30 BEDDED TRAUMA CARE UNIT DISTRICT HOSPITAL RAIGARH
SL.NO SCOPE OF WORK IN BRIEF UNIT QTY Lumpsum Amount in RS
1 For The Construction of Planning, Designing, Engineering, Procurement and Construction (EPC Mode-1) including one year of operation and maintenance of services of 300 Bedded District Hospital Building with 30 Bedded Trauma Care Unit (Up Gradation of 100 Bedded District Hospital) and Allied infrastructure development work i/c architectural planning, structural design wilh recommended type foundation as per existing soil strata & ground water table at site and structure/retaining walls designed to take load of Superstructure complete including Furnishing, Architectural Features e.g. Cladding, Facades, structural glazing, projections etc. all complete and planning and designning of all E & M services i/c furniture etc. as per provision contained in tender document and building the same and handover to owner after successfully commissioning of all civil and E & M services as per scope of work,Technical specification stipulated in Tender all complete as per direction of Engineer-in-charge.ON EPC CONTRACT BASIS Job (Lumpsum) 1.00
2 Dismentaling of Existing old structue (Old District Hospital Building) including disposal of all type of malba up to specifeid area and distance up 30 Km. and proper stacking of serviceable material with proper record of MAS/ T&P and handed over to the concern department as directed by the Engineer in charge. Job (Lumpsum) 1.00
INFRASTRUCTURE DEVELOPMENT WORK
3 For 300 BEDDED WITH 30 BEDDED TRAUMA CARE UNIT DISTRICT HOSPITAL RAIGARH -Engineering, Procurement, and Construction with Development of E&M facilities of the project required as per scope of work i/c Architectural planning , designing of services alongwith all civll work as per stipulated specifications and tender document all complete as per direction of Engineer-in-charge, which includes ON EPC CONTRACT BASIS .] (a) SITC of Electric Sub-Stations, VRV Plant Room, DG Yard, HSD Yard and its piping, Electrical HT/ LT cabling from s\vitchyard to substation blocks , and from sub- stations to individual buildings including HT ring main system (b) SITC of DG Sets complete with all accessories. (c) SITC of Transfomers complete with all accessories. (d) SITC of Coolling Towers, Chillers complete with all accessories. (e) SITC of HT Panels, LT Panels, Capacitor Panels and Sandwich Bus Ducts complete in all respect, HT & LT Cabling work, HSD Storage Tank, Pumps & Pipeline network, SCADA & BMS complete in all respects as per scope of work and direction of Engineer- In-Charge.' Note: Civil cost of ESS/ VRV Plant Room/DG Yard/HSD Yard shall be included in the quoted rate and the corresponding plinlh area / open plaffom area shall not be paid seperately. Job (Lumpsum) 1.00
4 For 300 BEDDED WITH 30 BEDDED TRAUMA CARE UNIT DISTRICT HOSPITAL RAIGARH -LEVELLING, INTERNAL ROADS, PATHS & COVERED WALKWAY PARKING ETC as per drawing . : (a)Levelling (b) Internal reinforced cement concrete road with vaccum dewatered concrete as per design grade of concrete with painting of side curb stone/ diveder etc. (c) Footpath with kerb stone (d) Parking (e) Covered walkway etc. (f) boom barriers (g) Gates, Security Rooms (h) Grass paver along the periphery of the individual buildings upto the adjoining road/footpath & for the green area of the campus as applicable etc as per scopeof work,Tender document all complete as per direction of Engineer-In -charge. Job (Lumpsum) 1.00
5 For 300 BEDDED WITH 30 BEDDED TRAUMA CARE UNIT DISTRICT HOSPITAL RAIGARH - The Construction of the Boundary wall at project site as per drawing, Infrastructure civil facilities of the project required as per scope of work i/c architectural planning , designing o(sen/ices as per stipulated specifications and drawings attached complete as per direction of Engineer-in-charge, which includes: ON EPC CONTRACT BASIS. Job (Lumpsum) 1.00
6 For 300 BEDDED WITH 30 BEDDED TRAUMA CARE UNIT DISTRICT HOSPITAL RAIGARH -SEWERAGE SYSTEM ETC. as per drawing, battery limit & scope of work as mentioned in the tender document :. (a) Civil and E&M work of UGT & Pump House, BMW, STP/ETP alongwith all equipment and accessories complete in all respect etc. (b) Filter Water Supply from the UGT to individual buildings, from STP/ETP to UGT, from UGT to VRV plant room etc (c) Distribution lines of required diameter pipes, (d) Peripheral grid of required diameter pipes (e) Unfiltered water supply distñbution lines from individual building to the STP/ETP and disposal of teated water with proper water supply for gardening and disposal of surpluse treated water from STP/ETP (f) Storm water drain for the individual building & along the road, as applicable, (g) Rain Water Harvesting (RWH) , (h) Trenchs for services, (i) Underground Sump (j) Irrigation work for the whole campus complete in all respect. etc. (k) Make up water line from UGT to STP (l) Tubewell boring & WTP (m) Main water supply line from Bore ell & source of Supply to UGT and distribution line up to the individual water supply (n) MGPS (o) Nurs calling system Job (Lumpsum) 1.00
7 For 300 BEDDED WITH 30 BEDDED TRAUMA CARE UNIT DISTRICT HOSPITAL RAIGARH -HORTICULTURE WORKS /LANDSCAPING WORKS: (a) Horticulture Operations including earth filling , grassing, tree plantations/shrubs and potted plants including tree guards etc. , (b) Existing Tree cutting, replantation,relocation as required and maintenance of Idle same till DLP c) Campus filling as per drawing & site requirement and direction of EIC (d) Developments of green area for the whole campus. (e) Boundary wall with grill in all open and garden portion Job (Lumpsum) 1.00
8 For 300 BEDDED WITH 30 BEDDED TRAUMA CARE UNIT DISTRICT HOSPITAL RAIGARH -EXTERNAL FIRE FIGHTING WORKS : External Fire fighting works for the entire campus including supply and installation of fix hydrant system complete in all respect. Fire Pumps in the Pump Room/UGT and Piping work from the Pump Room/UGT to the individual buildings under scope with provision for external fedder line. Job (Lumpsum) 1.00
9 For 300 BEDDED WITH 30 BEDDED TRAUMA CARE UNIT DISTRICT HOSPITAL RAIGARH -STREET LIGHTING WITH LED, EMERGENCY LIGHT, SOLAR LIGHT & GARDEN LIGHT, ILLUMINATED SIGNAGES, DIRECTIONAL SIGNAGES ETC..along the road as per drawing, scope of work as mentioned in the tender document: (a) Supplying, installation, testing and commissioning of LED street/solar/Compound/High mast / Pathway / Landscape Lighting,(b) Illuminated signages,Directional signages ,c)CCTV Camera & LV works including gates & guard room etc as per requirement. Job (Lumpsum) 1.00
10 For 300 BEDDED WITH 30 BEDDED TRAUMA CARE UNIT DISTRICT HOSPITAL RAIGARH - CSSD with all fittings etc. complete as per requirement. Job (Lumpsum) 1.00
TOTAL in RS (L-1 Will be decided on the basis of total sum of "Lump sum Amount" (column C))
NOTE :- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES (GST AND OTHER TAXES) ROYALTIES, SECC, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC.
ANY OTHER COMPONENT WHICH IS NOT DEFINED IN THE ABOVE SHEET SHALL BE INCLUSIVE IN RESPECTIVE ITEMS
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.02 MB
2543486276567957178_203695_Vol 1 NIT Raigarh final 6_Vol 1 NIT Raigarh final 6.11.docx
NIT • 0.26 MB
2364346068437589655_203695_Vol 2 NIT DH Raigarh Final_Vol 2 NIT DH Raigarh Final.docx
NIT • 0.42 MB
2305374141194564604_203695_Vol 3 NIT DH Raigarh_Vol 3 NIT DH Raigarh.docx
NIT • 0.28 MB
7196508245652013030_203695_Vol_Vol. 4 (List_of_Items).xls
NIT • 0.65 MB
949291239322140641_203695_Volum 5 Chnages(Final) (1)_Volum 5 Chnages(Final) (1).xlsx
NIT • 0.04 MB
5759131613019046513_203695_Volumw 06_Volumw 06_FINAL 300 BED 1ST Floor.pdf
NIT • 0.50 MB
5759131613019046513_203695_Volumw 06_Volumw 06_FINAL 300 BED 2ND Floor.pdf
NIT • 0.51 MB
5759131613019046513_203695_Volumw 06_Volumw 06_FINAL 300 BED 3RD floor.pdf
NIT • 0.51 MB
5759131613019046513_203695_Volumw 06_Volumw 06_FINAL 300 BED 4TH Floor.pdf
NIT • 0.16 MB
5759131613019046513_203695_Volumw 06_Volumw 06_FINAL 300 BED FINAL Basement.pdf
NIT • 0.17 MB
5759131613019046513_203695_Volumw 06_Volumw 06_FINAL 300 BED Ground floor.pdf
NIT • 0.54 MB
5759131613019046513_203695_Volumw 06_Volumw 06_Raigarh Hospital 3D.pdf
NIT • 17.01 MB
8130199106557351830_203695_Volume 7 Price bid Sheet final_Volume 7 Price bid Sheet final.xlsx
NIT • 0.01 MB
582619108732337759_183398_Raigarh Corrigendum.pdf
Attachment • 1.96 MB
4240542311597765246_183246_Corrigendum.pdf
Attachment • 0.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .