Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
20 Apr 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM(PandP)UC
DGM(PandP)UC PD Administrative building FACT,Udyogamandal
Installation and Commissioning of RLNG Burners in NP Plants of Fert-UC
2022_FACT_682464_1
3004/2022-2023/E25234
Limited
Miscellaneous Works
Item Rate
270 days
FACT, Udyogamandal
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹5,000
Yes
21 Apr 2022
6 Apr 2022
21 Apr 2022
6 Apr 2022
20 Apr 2022
6 Apr 2022
90 days
Installation & Commissioning of RLNG Burners in NP Plants of Fert-UC
Fabrication and mounting of Instrument stanchions. Work includes fabrication of instrument stanchion (size 50 NB, SCH80 MS pipe,length 130cm) with base plate of size 225mm X225mm X 6mm.and fixing the stanchion on the floor at site using anchor bolts. Note: All the materials will be issued by FACT except welding and cutting machine.
Fabrication and laying of transmitter impulse lines. Work includes Fabrication of transmitter impulse lines using SS pipe (Size 15NB SCH40/80) and fittings. Laying of these impulse lines from instrument 1st isolation valve to flow/pressure transmitter and connecting both ends using proper SS pipe fittings .All the welded joints of Impulse lines to be pressure tested to ensure leak proof.The fabricated impulse lines to be fixed by using proper clamps, nuts and bolts.All the materials will be supplied by FACT with free of cost.
Installation of DP /Pressure transmitters on instrument stanchions/ supports. Work includes Installation of DP /Pressure Transmitters on stanchions/supports with proper "U" clamps,nuts& bolts. Fixing 2 valve/3 valve manifolds on transmitter body with proper gaskets and bolts&nuts. Note: All the materials will be issued by FACT at free of cost.
Fabrication and laying of transmitter impulse lines. Work includes Fabrication of transmitter impulse lines using SS tubes (Size 12mm ODX1.5mm thick) and fittings. Laying of these impulse lines from instrument 1st isolation valve to flow/pressure transmitter and connecting both ends using proper tube fittings . If required, impulse lines to be fixed by using proper clamps, nuts and bolts. Note: All the materials will be issued by FACT at free of cost.
Laying of 6 mm/8mm SS pneumatic tubing from air headers to the air filter regulators or I/P Converters of control valves located at the plant site. Work includes laying of SS pneumatic tubing of sizes 6mm/8mm OD with standard SS fittings from air headder to control valve accesseries. One end shall be connected at air header tapping and the other end shall be connected at the air filter regulator/ I/P end. Sharp bends shalll be avoided and proper support shall be given using clamps for the pneumatic tubing. All the materials will be issued by FACT.
Supply of skilled Instrument craftsmen for attending instrumentation revamping works, tagging works, cable glanding, Calibration assistance, aux.control room relatedUp keeping , instr.repair assistance etc on 8 hour Shift basis, as directed by Engineer-in- charge. They shall be ITI/ITC Instrumentation certificate holders with experience in similar jobs/Apprenticeship in FACT .
Supply of semi skilled Instrument craftsmen for supporting instrumentation revamping works, tagging works, cable glanding, Calibration jobs , aux.control room related up keeping , instr.repair assistance etc on 8 hour Shift basis, as directed by Engineer-in- charge. They shall be ITI/ITC Instrumentation certificate holders.
Installation of Junction Boxes of size 350x420x150mm (approx) on newly fabricated MS Supports with GRP type CANOPY. The work shall include the fabrication of MS supports with necessary holes drilled for mounting the JBs & CANOPY and fixing it to the available structures by welding/using fastners (SS 304 bolt, nut and washers)/ anchor bolts). The Junction box & Canopy shall be mounted to the newly fabricated MS supports by using SS304 nut, bolt and washers of size M6 X 40. All the materials except SS304 Bolts, nuts & washers will be issued by FACT, free of cost (Required SS Bolts, nuts & washer to be supplied by the contractor). The canopy size (WxDxH) is approximately 550x450x325mm.
Fixing of Perforated Aluminium cable trays of size 2.5x50x25mm or Aluminium angles of size 50x50x6mm on to new/ existing MS supports in Fert-UC plants. The work shall include supply of SS304 nuts, bolts, washers required for the fixing of cable trays. Painting of MS supports with one coat of epoxy-based primer and two coats of epoxy paint of dark grey colour. Breaking of walls, sunshade etc to carry out the work comes under the scope of the contractor. Perforated Aluminium cable trays and MS structurals will be supplied by FACT free of cost.
Fixing of Perforated Aluminium cable trays of size 2.5x200x20mm or 2.5x300x30mm on to new/ existing MS supports in Fert-UC plants. The work shall include supply of SS304 nuts, bolts, washers required for the fixing of cable trays. Painting of MS supports with one coat of epoxy-based primer and two coats of epoxy paint of dark grey colour. Breaking of walls, sunshade etc to carry out the work comes under the scope of the contractor. Perforated Aluminium cable trays and MS structurals will be supplied by FACT free of cost.
Laying of Signal/Power Cables- 1pair/ 1triad The scope of work includes transportation of cables to site, Installation of OFC/signal/ power cables- 1pair/ 1triad with wires of size upto 1.5 SQMM by laying on new/existing cable tray/ rack / clamping on the wall / structure / routing under cavity floor / through GI pipe/trenches. The cables are to be laid from field instrument to Junction Boxes / Control Room and from RIO rooms to main control room. Dressing of cables in racks shall be by using Aluminium/ SS cable tie at intervals of minimum 1 meter on horizontal runs and 60 cm on vertical runs. Clamping of cables on structure shall be by welding and fixing suitable cleats. The scope of work includes making SS tags with cable numbers punched on it [as per cable schedule] and fixing them on both ends of the cables before entering the instruments, junction boxes or control room. The tags may be tied to the cable using SS wires. Supply and installation of all other items other than cables, required for the completion of work like Aluminium strips, SS tags, SS wires, SS screw etc are included in the scope of bidder.
Termination of Signal/ Power Cables, 0.5 to 2.5 sq.mm Termination of individual wires size 0.5 to 2.5 sqmm of 20pair/ 12 pair/ 12 Triad/ 1 Pair/ 1 Triad cables at terminal strips in Junction Box and field instruments. The work shall include, removal of outer sheath, insertion of printed ferrules, crimping lugs on to individual cores, earthing of shield wire, and connecting the cable at the terminal strip/ field instruments with proper dressing. All wires or leads terminated at connection shall have sufficient slack. The unused wires in the cables shall be tied properly with cable ties & supports and kept neatly dressed inside the junction box. Cross ferruling shall be followed. Adhesive type cable tie hooks shall not be used inside the junction boxes. Supply and installation of all other items required for the completion of work like Tin-plated copper bootlace type Crimping lugs, PVC ferrules, cable ties etc are included in this item. Printing of ferules are also included in the scope of vendor."
Removal of unused armoured cables of size 12 / 20 pair, 12 triad from different plant areas in UC and transportation of the same to scrap yard or a place identified by the Engineer in charge.
Transportation and Erection of BMS Panel at 300 TPD and 150 TPD Ammonium Phosphate Plants. The scope of work includes transportation of BMS panel in wooden packing box/loose from store, to the sites (Approved by Engineer in charge) at 300 TPD and 150 TPD Ammonium Phosphate Plants. Erection of the BMS Panel to be done as per drawing (Approved by Engineer in charge) on the floor at site using anchor bolts.
The scope of work includes installation/ laying of 1 number of CAT 6 twisted pair armoured cable through HDPE conduit. 1 No CAT 6 twisted pair armoured cable (Approved by Engineer in charge) [10mm(approx.) OD ]to be inserted into 32mm HDPE conduit (Suitable for use with CAT 6 twisted pair armoured cable, Colour: Orange/ Approved by Engineer in charge) and laying on existing cable tray/ rack / clamping on the wall / structure / routing under cavity floor / through GI pipe/trenches. The cables are to be laid from LNG BMS panel to RIO control room. Dressing of cables in racks shall be by using Aluminium/ SS cable tie at intervals of minimum 1 meter on horizontal runs and 60 cm on vertical runs. Clamping of cables on structure shall be by welding and fixing suitable cleats. The scope of work includes making SS tags with cable numbers punched on it [as per cable schedule] and fixing them on both ends of the cables before entering the panels or control room. The tags may be tied to the cable using SS wires. Supply of all items , required for the completion of installation like CAT 6 twisted pair armoured cable, HDPE conduit, Connectors, End Cap, Fittings, Sealing Materials, Aluminium strips, SS tags, SS wires, SS screw etc. are included in the scope of bidder.
PEEJESS ELECTRICALS
INFANT JESUS SMITH AND ENNG WORKS
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .