Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST |
Tender Value
₹12.8 L
EMD Value
₹26,000
Closing Date
10 Dec 2020, 5:00 pmClosed
Raj Kumar, EE
Executive Engineer,Jag Provincial Division PWD B and R Br Yamuna Nagar
Centralized Oxygen System for SNCU at Sub District Hospital (SDH) Jagadhri and construction of 01 No. Room in Civil Hospital at Jagadhri in Yamuna Nagar District
2020_HRY_149687_2
PWD/CHD/YNGAR/1047
Open Tender
Construction Works
Works
90 days
Yamuna Nagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹26,000
Yamuna Nagar
22 Apr 2021
26 Nov 2020
11 Dec 2020
26 Nov 2020
10 Dec 2020
26 Nov 2020
1 Dec 2020
Amount
Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around mansonry, in 15cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30meters (HSR 6.6)
Earth filling under floors with surplus soil, excavated from foundation & taken only from outside the building plinth, in 15cm layers including ramming, watering & consolidating lead upto 30 meters (HSR 6.13) a)
Cement concrete 1:8:16 with stone aggregate 40mm nominal size in foundation & plinth (HSR 10.28)
First class brick work laid in cement sand mortar 1:6 in foundation & plinth (HSR 11.2)
Damp proof course 40mm thick of cement concrete 1:2:4 using stone aggregate 20mm nominal size with 2 coats of bitumen 20/30 penetration, at 1.65 Kg per sqm laid hot & sanded(HSR 10.114)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 meter above plinth level (HSR 11.7)
Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centering and shuttering, laid in position, complete in all respects. (HSR 10.82+10.95(a))
Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects. (HSR 10.86+10.95 (a))
Steel reinforcement TMT bars FE-500 EQR / FE-500 'D' grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/depths/storeys / basements etc. (HSR 18.22) Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
Supplying & fixing fan clamps with 50 mm x 6 mm flat iron 50 cm long & U-hooks of 16 mm diameter M.S bars, of approved size with nuts including threading etc., complete (HSR 18.37)
12 mm thick cement plaster 1:4 (HSR 15.5)
10 mm thick cement plaster 1:4 under side of Ceiling (HSR 15.52)
Providing and applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get and even and smooth finish including cost and carriage of all material, labour charges, scoffolding, sundries etc. complete (J. K./ Birla Make) (HSR 16.81)
Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work (HSR 16.58)
Providing 2 coats of exterior acrylic emulsion paint (HSR 16.79) (b) 1st Quality
Terracing consisting of 19mm thick Heat resistant tiles for roof insulation, 300mm x 300mm laid on 20mm thick 1:3 cement coarse sand mortar including grouting with neat white cement over average 75mm thick screed of 1:8:16 including 2 coats of bitumen laid hot at 1.65kg per sqmt. on top of RCC slab & cleaning of top surface complete. The tiles shall be made of white cement blended with fibrous polymer having flextural stress value of ≥ 150kg/sqcm & thermal conductivity value ≤ 0.18w/m.k (Note: Including rubbing and polishing) (HSR 13.97)
Cement concrete 1:2:4 gola 10 cm x 10 cm quardrant along junction of roof with parapet wall finished smooth, where specially specified (HSR 13.64)
Top Khurra 0.6mm x 0.6mm for rain water pipe in 25mm thick cemenr concrete 1:2:4 over 50mm thick cemenr concrete 1:8:16 (HSR 13.50)
Bottom khurra on ground 1.2m x 0.6m consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12mm thick cemenr plaster 1:3 (HSR 13.57)
Providing and fixing PVC Rain water pipe 6Kg. Pressure of ISI mark in cement mortar during masonary work. (HSR 13.89) a) 100mm dia PVC pipe 6 Kg. Pressure.
Providing and fixing PVC Bend ISI mark (HSR 13.90) a) 100mm dia PVC Bend
Providing and fixing aluminium work for doors windows, ventilators and partitions wit extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS, 733 and IS:1285 fixed with rawlplugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required neoprene felt etc. aluminium sections shall be smooth, rust free straight mitred and jointed mechanically wherever required including cleat angle. Aluminium snap beading for glazing/pancelling C.P. brass/stainless steel screws, all complete. Shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required including aluminium fitting. (HSR 17.96) Note:- (i) Add 15/- per Kg. extra if powder coating of 50 micron is done instead of anodizing in above item No.9 & 10. (ii) Add 20/- per Kg. extra if polyester powder coating of 50 micron is done instead of anodizing in above item No.9 & 10.
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer of graded wood particle board conforming to IS:12823 grade I type II in paneling fixed in aluminum doors. Windows shutters and partition frames with C.P. brass/stainless steel screws etc. complete. (HSR 17.97) b) Pre-laminated particle board with decorative lamination on both side
Providing and fixing glazing in aluminium door windows, ventilator shutter and partitions etc. with pve/neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basic items). (HSR 17.98) b) With float glass panes of 5mm thickness.
Providing and fixing aluminium round shape handle of cutter dia 100mm with screw etc. complete in all respect (HSR 17.102) iii) Polyester powder coated minimum thickness 50micron aluminium
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 & 100 mm sand or stone filling (HSR 14.1)
Providing & Fixing Vitrified Tiles 600x600mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1.3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. (HSR 14.90) Note: Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO.
Providing & fixing vitrified tiles of size 600mm x600mm of approved make in skirting/dados laid in any pattern as specified over base of 12mm thick cement coarse sand mortor 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. (HSR 14.90) Note:Tiles shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT, JOHNSONS & RAK. (Minimum base rate of tile is Rs. 500/- per sqm ) Note :Quantity and issue rate for the material will be as per annexure 'A'
Distribution copper piping with copper elbow, tee, socket, Brazing testing all copper pipe made of Phosphorous de-oxide, non arsenical as per BS 2871, Part-1, Table -X (BSEn 1057) i) 12mm x 0.9mm thick
ii) 15mm x 0.9mm thick
iii) 22mm x 0.9mm thick
Providing and fixing of BPC Oxygen flow meter with Humidityfire bottle with probe
Providing and fixing Gas outlet Oxygen /Vaccum M-50 (CE approved as per BS EN 737-1.1.1989)
Ward Vaccum Regulator with Vaccum Gauge (0076mm/hg) unbreakable transparent collection Jar with Overflow safety Valve 600ML
Copper piping medical grade of following size
Vaccum plant consisting of 2 one of Vacum Pump 3 HP capacity with receiver tank presure switch starter etc.
Down Drop Isolation Ball Valve 15mm with filling
Down Drop Isolation Ball Valve 28mm with filling
Down Drop Isolation Ball Valve 22mm with filling
Modle-3 Pipe line alarm system (O2/ Vaccum) (Audio visual
Horizontal BED HED panel (Modle-2) 3 feet long powder coating provision of Gas Outlet point and electrical switches.
Electrical / Machenical accessory for Bed HED Panels i) Electrical / Machenical accessory for Bed HED Panels
ii) Monitor Stand
iii) Hook stand with slider
iv) IV Pole stand with slider
v) Vaccum unit slider
vi) Utility Baskate SS
Oxygen Manyfold 4+4 with semi automatic control panel complete with NRV, Tail pipe with fitting
Oxygen 1+1 with single stage double gauge regulator, NRV, Tail, pipe with fitting
Plastic Saddle i) 15mm thick
ii) 12mm thick
iii) 22mm thick
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .