Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹85.6 LAdmitted-Finance PLOT NO N3 414 IRC VILLAGE NAYAPALLI BHUBANESWAR DIST KHURDA STATE ODISHA PIN 751015 | BHUBANESWAR | KHURDA | ODISHA | 751015 | -23.99% | ₹85.6 L | L1 | Admitted-Finance |
| 2 | L2₹85.9 LAdmitted-Finance AT BARAJANGHA PO GORUALA PURI 752011 | PURI | PURI | ODISHA | 752011 | -23.75% | ₹85.9 L | L2 | Admitted-Finance |
| 3 | L3₹90.1 LAdmitted-Finance GADASAHI GADASAHI PURI 752017 | PURI | ODISHA | 752017 | -19.99% | ₹90.1 L | L3 | Admitted-Finance |
| 4 | L4₹94.0 LAdmitted-Finance | -16.60% | ₹94.0 L | L4 | Admitted-Finance |
| 5 | L5₹94.6 LAdmitted-Finance | -16.00% | ₹94.6 L | L5 | Admitted-Finance |
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
18 Feb 2026, 5:00 pmClosed
CCE Khordha RandB Circle Khordha
O/o the Chief Construction Engineer Khordha R and B Circle Khordha
Construction of First floor Building over existing Annex Building of Raj Bhawan at Puri for the year 2025-26
2026_EICCL_125393_1
CCE KHORDHA (RAND B) CIRCLE 12/2025-26
Open Tender
Civil Works - Buildings
120 days
Puri
3 documents required · 3 mandatory
₹10,000
₹1.1 L
Yes
23 Apr 2026
2 Feb 2026
19 Feb 2026
2 Feb 2026
18 Feb 2026
2 Feb 2026
2 Feb 2026 - 18 Feb 2026
Earth work in excavation in foundation in ordinary soils in trenches, column foundation, pit etc in hard soil including dressing of sides and levelling the bed upto the required depth and depositing the excavated materials away from the work site with initial lead of 50mt and all lifts including shoring, shuttering and dewatering (if required) with cost of labour , labour cess, hire and running charges of all materials complete Including all cost i.e cost of all materials, all labour, all T&P, royalty etc complete in all respect as per direction of Engineer in charge. Ground Floor
Site Development
Supplying & Filling foundation trenches , plinth & ditches with Excavated Earth well watered and rammed in layers not exceeding 20 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking, royalties and all cost & conveyance of water, cost of all Labour,labour ess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge.Ground Floor
Carriage / disposal of excavated surplus earth from the worksite by mechanical means within a lead of 5Km including loading and unloading etc. complete. in all respect as per direction of Engineer-in-Charge.Ground Floor
Supplying & Filling foundation trenches , plinth & ditches with clean coarse river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking, royalties and all cost & conveyance of water, cost of all Labour,labour ess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge.Ground Floor
Site Development
Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size hard crusher broken granite stone aggregate and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including all cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge.Ground Floor
Providing and laying plain cement concrete of proportion (1:4:8) in foundation and floors using 4 cm. size hard crusher broken granite stone aggregate and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including all cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge.Ground Floor
Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 using 12 mm. to 20 mm. (½ to ¾) size (20 mm. not to exceed 25%) hard crusher broken granite stone aggregate of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with all cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge. Ground Floor a)Foundation
b)Plinth Beam
c)Column upto roof
d)Roof Beam :
e)Lintel :
f)Chajja
g)Stair case :
First Floor Column
b)Roof Beam :
c)Lintel :
d)Chajja
e)Roof Slab :
f)Stair case :
Second Floor Column
b)Roof Beam :
c)Lintel :
d)Chajja
e)Roof Slab :
Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 using 12 mm. to 20 mm. (½ to ¾) size (20 mm. not to exceed 25%) hard crusher broken granite stone aggregate of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with all cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge. FRAMELESS STRUCTURE First Floor (Roof Beam)
b)Lintel :
c)Chajja
d)Roof Slab :
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / TATA / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including all cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of the Engineer-in-charge.Ground Floor
First Floor
Second Floor
First Floor Frame Less Structure
Fly Ash brick masonry in cement mortar (1:6) in Foundation and plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including all cost, conveyance, royalties with all labour,labour cess and T & P required for the work complete in all respect as per specification and direction of tne Engineer-in-Charge.Ground Floor
Fly Ash brick masonry in cement mortar (1:6) in Super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including all cost, conveyance, royalties with all labour,labour cess and T & P required for the work complete in all respect as per specification and direction of tne Engineer-in-Charge.Ground Floor
First Floor
Second Floor
First Floor Frame Less Structure
Second Floor Frame Less Structure
Fly Ash brick masonry in cement mortar (1:4) in Super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including all cost, conveyance, royalties with all labour,labour cess and T & P required for the work complete in all respect as per specification and direction of tne Engineer-in-Charge.First Floor
First Floor Frame Less Structure
Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with all cost, conveyance, royalties, with cost of all labour,labour cess, T&P and scaffolding required for the work etc. complete in all respect as per direction of the Engineer-in-charge .Ground Floor
First Floor
Second Floor
First Floor Frame Less Structure
Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with all cost, conveyance, royalties, with cost of all labour,labour cess, T&P and scaffolding required for the work etc. complete in all respect as per direction of the Engineer-in-charge .Ground Floor
First Floor
Second Floor
First Floor Frame Less Structure
Providing 12mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with all cost, conveyance, royalties, with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect and specification and direction of the Engineer in charge. Ground Floor
First Floor
Second Floor
First Floor Frame Less Structure
Second Floor Frame Less Structure
Supplying, fitting & fixing of Vitrified colour printed series tiles of thickness 8mm to 10mm in floors of size 600mm x 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour, labour cess, T&P etc. required for the work all complete as per direction of the Engineer-in-charge Ground Floor
First Floor
First Floor Frame Less Structure
Supplying, fitting & fixing of Vitrified colour printed series tiles in dadoes, skirting and risers of steps of size 600mmx 600mm of approved make confirming to IS:13755 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge Ground Floor
First Floor
First Floor Frame Less Structure
Supplying, fitting & fixing of Granite Tiles of minimum 20mm thick and size above 0.40 sqm of approved make in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect and as per direction of the Engineer-in-charge Ground Floor
First Floor
Supplying, fitting & fixing of Granite Tiles of minimum 20mm thick and size above 0.40 Sqm of approved make in dadoes, skirting and risers of nsteps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge Ground Floor
First Floor
Supplying fitting and fixing of ISI marked 35mm thick flush door shutters confirming to IS: 2202 (Part-1) decorative type core of block board construction with frame of first class hard wood and well matched teak three ply veneering with vrtical grains or cross bands and face veneers on both face of shutter of approved design and quality including cost of all door fittings and fixtures etc. Complete as per direction of Engineer in charge.First Floor
Second Floor
First Floor Frame Less Structure
Supplying of G.I. Grills/shutter of approved quality and design to windows and openings and staircase railing and parapet railings etc including making holes in walls and RCC structures or wood work etc in proper position making good the damages of walls or RCC or other structures complete including bending or cutting sizes or grooves in chowkhats with all cost and conveyance of all materials labour , labour cess with T&P required for the work and royalities etc.complete (including screws) in all respect in all floors as per the direction of Engineer-in-Charge .Ground Floor
First Floor
Second Floor
First Floor Frame Less Structure
Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including sand papering, cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge Ground floor
First Floor
Second Floor
First Floor Frame Less Structure
Second Floor Frame Less Structure
Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion "Royale Shyne" of Asian Paints or equivalent of approved shade over a coat of primer as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. including interior wall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge.Ground Floor
First Floor
Second Floor
First Floor Frame Less Structure
Supplying and fixing of Double skin wall paneling made of aluminum anodised section framing conforming to standard Aluminium sections as horizontal and vertical members with atleast 600mm c/c with 9mm thick BWR block ply and 4mm thick veneer finished with melamine polished on both the faces complete as per direction of Engineer- in -charge.First floor
Painting to external surface of building with two coats of weather seal coat of approved shade and quality of approved design over a coat primer after cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge.Ground floor
First Floor
Second Floor
First Floor Frame Less Structure
Second Floor Frame Less Structure
Supplying, fitting and fixing hand railing of Stainless steel of 304 grade using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with all cost, conveyance, taxes of all materials, cost of all labour, T&P etc. required for the complete in all respect as per direction of the Engineer-in-charge. Ground Floor
First Floor
Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor.First Floor
Second Floor
First Floor Frame Less Structure
Second Floor Frame Less Structure
Supplying diluting and preparing chemical emulsion like CHLORPY RIPHOS or other chemicals approved by central insectiicides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as per constructional anti termite treatment and creating a chemical barrier under and column pits and trenches basement excavation top surface of plinth filling junction of walls and floors along with external perimeter of the building expansion joints surrounding the pipes and conduits etc complete at the rate of 7.5 litters or as directed by the Manufacturer per sqm on vertical and 5.0 litters per sqm on horizontal surfaces 50% of the emulsion to be filled in the holes made in trenches at 150mm centrer to center etc complete as per IS 6313/1981 (Part-II) and as per the direction of the Engineer-in-Charge including cost of all materials, labour,taxes etc complete.
Supplying, fitting, fixing of two track UPVC Sliding Window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fittings and fixtures etc complete as per direction of Engineer in charge.Ground Floor
First Floor
Second Floor
First Floor Frame Less Structure
Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete as per direction of Engineer- in -charge.Ground Floor
First Floor
Second Floor
First Floor Frame Less Structure
Construction of Granular sub-base by providing Grading-VI material as per table 400-2, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoRT&H Specifications for Road & Bridge works (5th Revision) & Including all cost i.e cost of all materials, all labour, all T&P, royalty etc complete in all respect and as per direction of the Engineer- in- charge.
Supplying and Fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour & size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP- 63:2018 and as per the direction of Engineer-in-charge.
Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect confirming to IS 5758:1984 including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.
INTERNAL ELECTRICAL WORK Internal Wiring including supply of all required materials Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type Modular switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire-Finolex/ L&T/ Anchor/ Havells) (Make of Modular Box-Great white/ Legrand / Roma/ Havells ) Single light point controlled by one 6A switch or first light point or group control - Group-A .
Single light point controlled by one 6A switch or first light point or group control - Group-B .
Single light point controlled by one 6A switch or first light point or group control - Group-C .
Recessed wiring to exhaust fan point - Group-B .
Recessed wiring to call bell point - Group-B .
Recessed wiring to ceiling fan point including fixing of 5inch dia ceiling fan box with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire-Finolex/ L&T/ Anchor/ Havells) & fixing of 5inch dia ceiling fan box. (Space shall be provided for installation of electronics type stepped fan regulator)
Supply & fixing of 5 / 6 amp socket outlet on existing switch board with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge.
Supply, fixing with recessed wiring to 5 / 6 amp socket outlet on separate board 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.
Supply & fixing of 2 x 6 amp socket outlet for TV & multiuse in Rooms etc. controlled by , 250 V clip in type switch modular ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge.
Mirror Light Point
Supply, delivery, installation & testing of following plug boards including interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge.6 / 16 ampere plug boards consisting of a 16 amp clip-in type modular switch with indicator and a 6/16 amp clip-in type modular shuttered plug socket fixed on metallic concealed box (for Kitchen,W/Mc & Lift Shaft)
6 / 16 ampere plug boards consisting of a 6/16 amp clip-in type modular shuttered plug socket fixed on metallic concealed box (for Geyser & AC outlet near IDU)
6 / 16 ampere switch boards consisting of a 16 amp clip-in type modular switch with indicator fixed on metallic concealed box (for Geyser)
25 ampere switch boards consisting of a 25 amp clip-in type modular DP switch with indicator fixed on metallic concealed box (for AC)
Wiring for circuits & submain with following number & sizes of FRLS PVC insulated 1100 volt grade multistranded copper conductor wire run inside 2mm thick PVC conduit pipe recessed in ceiling/ column/ walls of building including supply of all materials such as wires, PVC conduit, junction box & pull box etc complete with making good the damages caused as required and as per direction of Engineer-in-charge.Inverter wiring to essential light points, Fan points, 6A plug points with 1.5-sqmm FRLS PVC insulated 1100 volt grade multi-stranded copper conductor wire for phase run inside existing 2-mm wall thick non-metallic PVC conduit pipe of circuit wiring, recessed in wall of the building complete as required and as per direction of Engineer-in-charge.
Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For subsequent point of group control )
Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From BDB to Switch Board & 16A socket points )
Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From BDB to A/C points )
Recessed wiring to submain in 4 x 10sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For BDB-L&P)
Panel & Distribution Boards Supply, delivery, installation, testing & commissioning of L.T. indoor wall mounted double door type distribution boards of original factory made enclosures of the same brand as the MCB conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. Panel & Distribution Boards Supply, delivery, installation, testing & commissioning of L.T. indoor wall mounted double door type distribution boards of original factory made enclosures of the same brand as the MCB conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. FDB- Annexe Building (1F) Incoming: 1 No 125-A, 500V 3P+NL MCCB with ROM and adjustable thermal setting & spreader links 1no 125A On Load Change Over Switch Busbar: 4 nos 25x6mm Electrolytic copper strips 3no.63A TPN MCB C ( BDB-L&P ) 3no.25A DP MCB C Instruments: 3 Nos phase indicating lamp with toggle switch and control fuses 1 sets each of 4 Nos.40-kA SP VSP along with 32 Amp SP MCB backup protection for each VSP at main incomer 1 Nos 0-500V AC Digital voltmeter 1 no 0-150A AC Digital Ammeter with 125/5A CTs Complete duly factory wired as per SLD
Distribution Board Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted following sizes TPN , MCB DB suitable for 415 V, 3phase, 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.(But without MCB/ RCCB/ ISOLATOR) (make- L&T / Legrand / Schneider or equvalant reputed make) 8 way (8 + 24 ), TPN , MCB DB double door horizontal type
Supply and fixing of following rating double pole (single pole and neutral) 240 V residual current break (RCCB) having a sensitivity current up to 300 milli ampere in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required.(make- L&T / Legrand / Schneider or equvalant reputed make) 63Amp 2P RCCB (100mA/300mA)
Supplying and fixing 25-63 Amps rating, four pole, 415 volts, RCCB,100mA/300mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(make- L&T / Legrand / Schneider or equvalant reputed make) 63Amp 4P RCCB (100mA/300mA)
Supply and fixing of 6 amp to 32 amp rating 240 V C series miniature circuit breaker suitable for inductive loads of the following poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make- L&T / Legrand / Schneider or equvalant reputed make) 6Amp rating to 32Amp (SP) MCB
Cabling Work Supply of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade Al. conductor cable of following size. direct in ground including excavation , sand cushioning protective covering and refilling the trench etc.or on surface / on existing cable tray as required. ( Polycab / Finolex / Havells / Rhino / RR Kabel ) 3.5 core x 70 sqmm ( 1F Panel)
Supply of materials and end termination of following cables including supply of single compression brass cable glands, cable sockets etc complete as required and as per direction of Engineer-in-charge. 3.5 core x 70 sqmm
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes on LAYING OF CABLE ON SURFACE as required. MV cable laying up to 25 sq.mm to 120sqmm in ground
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes on LAYING OF CABLE ON GROUND as required. MV cable laying from 25 sq.mm to 120 sq.mm in ground
Supply, delivery, installation and testing of following types of fluorescent tube fixtures directly on wall / ceiling of building with all accessories such as electronics ballast, lamps, stove enamelled box, perpex sheet cover etc complete assembly and making connection from the suitable point outlet as per the direction of Engineer-in-charge.( For Common Service Areas) Angle Holder with 9 watt led bulb as per make approved by Architect/ Consultant.
Bulk Head Light fixture as per make approved by Architect/ Consultant. (Inside Lift Shaft)
1x18watt Celling Light as per make approved by Architect/ Consultant.(prefer company phillips / havels)
Supply of 11W Mirror LED Wall Light suitable for use as Mirror light Philips catalouge BN 021 LED12S 6500 PSU GR with all connections or equivalent
1 x 20 watt LED tube fixtures as per make approved by Architect/ Consultant.(prefer company phillips / havels)
1x70W LED Street Light Luminaire to be fixed at parapet wall for outside lighting with Lamp as per make approved by Engineer-in-charge / Architect / Consultant.(prefer company Phillips / Havells)
Supply, delivery, installation and testing of following sweeps of High Speed energy efficient A.C. ceiling fan complete with fan blades, down rod, canopies, capacitor etc including supply of sundry materials, making connection from the suitable point outlet but excluding cost of fan regulator complete as required and as per the direction of Engineer-in-charge. 900 mm sweep
1200 mm sweep
Supply, delivery, installation & testing of electronic type stepped fan regulator fixed on existing sheet metal switch board including interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge.
Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.
Supply, Installation, testing and commissioning of Electric Storage Water Heater of 15 Ltrs Capacity Havells ( Vellora+ ) make or equivalent complete etc.as required
Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required.
Numbering ceiling fan / exhaust fan / fluorescent fittings as required
Earthing Supply of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. (For Panel 2Nos)
Supply of materials and laying under ground / floor / wall including making end termination and testing of 6 swg G.I. wire for loop earthing of equipments, switch boards & panels as required complete as per direction of Engineer-in-charge.
Supply of materials and laying on ceiling/ column/ wall or buried under ground including saddling & making connection at both ends and testing with following size of hot dip galvanised iron flats for earth termination and earth interconnection, making good the damages caused as required complete as per direction of Engineer-in-charge. 25mm x 6mm as Earthing conductor
Building Lightning Protection Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn
Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn
Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn
Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn
Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn
Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3. Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn
Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn
Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn
Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn
Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn
Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn
Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn
Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
Safety Equipments Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate.
Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate .
Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
Warning signs 415 V for Main LT panel rooms, Electrical rooms etc.
Providing and fixing M.V danger board of 250 mm x 200 mm made mild steel at least 2 mm thick and vitreous enameled white on both sides and with inscription in single red colours on front side as required.
AIR CONDITIONING Supply, delivery, installation & testing of 2.0 Tr Split type Air Conditioner ( 5 star rating) complete with indoor & Outdoor unit,including supply of sundry materials , insulation, piping from IDU to ODU, making connection from suitable point outlet, making good the damages caused complete as required and as per direction of Engineer-in-charge.
Supply, delivery, installation & testing of 1.5 Tr Split type Air Conditioner ( 5 star rating) complete with indoor & Outdoor unit,including supply of sundry materials , insulation, piping from IDU to ODU, making connection from suitable point outlet, making good the damages caused complete as required and as per direction of Engineer-in-charge.
Supply & fixing of 5KVA automatic voltage stabiliser with connection in all respect complete as required
PH. Work Supplying all materials, labour, T&P and Providing and fixing Chlorinated Polyvinyl Chloride (CPVC/UPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge In 1st. floor = 20mm dia C-PVC pipes
25mm dia C-PVC pipes
25mm dia UPVC ASTM-D pipes
32mm dia UPVC ASTM-D pipes
In 2nd. floor = 40mm dia UPVC ASTM-D pipes
50mm dia UPVC ASTM-D pipes
Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. In 1st. Floor - 250mm thick wall
Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge 250mm to 375mm thick wall.
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In 1st. Floor
Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge 15mm dia long body Bib Cock cock (Jaquar)-CON-CHR-107KN
15mm dia CP angle stop cock (FLR-ACR-5053N)
15mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN
HAND SHOWER (HEALTH FAUCET) WITH 1 METER (Jaquar- ALD-CHR-565)
150mm dia CP Revolving Shower (Jaquar) OHS-CHR-1803
SHOWER ARM STRAIGHT 20mm DIA & 450mm LON (Jaquar) SHA-ABR-49483
HAND SHOWER 95mm DIA ROUND SHAPE MULTI F (Jaquar) HSH-CHR-1739
FLEXIBLE TUBE 8mm DIA. & 1.5M LONG WITH (Jaquar) SHA-ABR-549D8
WALL BRACKET (Jaquar) SHA-ABR-555MI
3-in-1 Wall Mixture (Jaquar) FLR-CHR-5273UPR
Basin Mixture (Jaquar) FLR-CHR-5051B
15mm dia CP SINK cock (Jaquar)FLR-CHR-5347N
25mm CPVC Ball Valve
32mm CPVC Ball Valve
40mm CPVC Ball Valve
50mm CPVC Ball Valve
15mm dia CP Extension piece
125mm dia CP Gratting
Supplying all materials, labour, T&P and fixing Wash Down Water Closet (European type W.C pan) with integral S or P trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification and direction of the Engineer in charge SINGLE PIECE-WC WITH UF SOFT CLOSE SLIM (Jaquar) LYS-WHT-38851PSM
Supplying all materials, labour, T&P and fitting & fixing stainless steel AISI 304 (18/8) Library/Kitchen sink with drain board as per IS 13983 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge. 600x450x250 mm stainless steel kitchen sink
Supplying all materials, labour, T&P and fixing of wash hand basins with pedestal complete recessed at the back for the reception of pipes and fittings with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge TABLE TOP BASIN, SIZE:500*420*120mm (Jaquar) FLS-WHT-5935
WALL HUNG BASIN WITH FIXING ACCESSORIES (Jaquar) FNS-WHT-40801
HALF PEDESTAL WITH FIXING ACCESSORIES SE (Jaquar) FNS-WHT-40305
Supplying all materials, labour, T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge 2000 Ltr PVC water storage tank (3 Layer White)-on 3rd. Floor
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge 110mm dia U-PVC SWR pipe (Supreem/Ashirvad)
75 mm dia UPVC SWR Pipe
110mm U-PVC Door Tee
110mm U-PVC Plain Tee
110mm U-PVC Door Bend
110mm U-PVC Plain Bend
110mm dia U-PVC 'P' trap
110mm U-PVC Cowl.
75 mm dia UPVC plain bend (supreme/ashirvad)
76 mm dia UPVC plain Tee (supreme/ashirvad)
PVC clamp suitable for 75 mm to 110mm dia pipe
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge Design Mirror
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge 600mm Glass Shelf (Jaquar) ACN-CHR-1171N
CORNER SHOWER BASKET (Jaquar) ACN-CHR-1175N
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 600mm long CP Towel Rail (Jaquar) ACN-CHR-1111NM
CP Towel Ring (Jaquar) ACN-CHR-1121N
600mm long Towek Rack (Jaquar) ACN-CHR-1181S
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP Soap Holder (Jaquar) ACN-CHR-1131N
Liquid Soap Dispenser with G. Bottle (Jaquar) ACN-CHR-1135N
Toilet Paper Holder (Jaquar) ACN-CHR-1153S
CP double coat hook (Jaquar) ACN-CHR-1161N
Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 80 PSS UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. (Aqua guard) Pure Chill 80 PSS UV
Supplying all materials, labour T&P and fitting and fixing of Stainless steel stand for Aquaguard cooler-cum-purifier of size (700x430x460mm ht) with water cooling capacity of 40 PPH etc. all complete as per specification and direction of the Engineer-in-charge. Stainless steel for Aquaguard stand
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
Factory made Solid WPC door frame of size 95mmx55mm fabricated. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing Vetrified mat finish tiles in floor, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. (Ceramic tile size 600mmx600mm, Kajaria-Fog parla or Equivalent) plain/printed to be pre-approved by the Engineer in charge) In 1st. Floor
Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. (Glazed tile size 600mmx300mm, Kajaria-Duren Morfil or Equivalent) plain/printed to be pre-approved by the Engineer in charge) In 1st. Floor
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In 1st. Floor = Measurement same as above tiles in dados
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chipsincluding watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In 1st. Floor = 37.18x0.10 =
Supplying all materials, labour, T&P and fixing Granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge In Ground floor IN FF
Supplying and fitting-fixing of UPVC Louvers fixed window/ventilator made of (small series) frame 47x50mm & mullion 47x68 mm both having wall thickness of 1.9± 0.2mm and single glazing bead of appropriate dimension (Area upto 0.75sqm) etc.all complete as per direction of the Engineer-in-charge.
Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1ft-6inch in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. In , First floor ( floor)
Supplying all materials.labour.T&P and providing brick work with KB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar(1:4) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. FF=
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In 1st floor
Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. IN FF ,
Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. 0.80 qntl/ cum IN FF
Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge Gully trap chamber of size 250mmx250mm with R.C.C cover slab
Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Inspection chamber Inside size 760mmx760mmx460mm
RCPC Cover (18" round)
Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Man hole chamber Inside size 910mmx910mmx910mm
RCPC Cover (24 round)
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class-3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturers specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia u-pvc pipe alround concrete
160mm dia U-PVC Alround Concrete
Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. 1.40m dia x 2.00m deep soakway pit
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_2.pdf
PDF • 2.01 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_578858.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid