| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹2.1 Cr+₹2.0 Cr (1094.8%)Rejected-Finance | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹21.5 L+₹3.6 L (20.4%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L3 | Rejected-Finance Due to L3 | |
| 4 | L4₹29.7 L+₹11.8 L (66.2%)Rejected-Finance | L4 | Rejected-Finance Due to L4 | |
| 5 | L5₹30.2 L+₹12.4 L (69.4%)Rejected-Finance E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L5 | Rejected-Finance Due to L5 |
Tender Value
₹24.8 L
EMD Value
₹49,600
Closing Date
26 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
RENEWAL OF DISTRIBUTION BOARDS, LT SWITCH GEARS ALONG WITH CONNECTED ITEMS UNDER GE AF BIDAR
2021_MES_463550_1
8295/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Bidar
As per NIT
7 documents required · 7 mandatory
₹500
GE AF BIDAR
₹49,600
Yes
19 Oct 2021
29 Jul 2021
27 Aug 2021
29 Jul 2021
26 Aug 2021
12 Aug 2021
60 days
Amount
Taking down existing unserviceable MCB DB's any type complete all as directed.
Taking down existing unserviceable MCB's any type complete all as directed.
Taking down existing unserviceable sub main wiring single phase with conduit complete, all as directed.
Taking down existing unserviceable sub main wiring three phase with conduit complete, all as directed.
Sub main wiring / power wiring complete with two runs of 4 Sqmm, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface of wall /floors / roof with one run of PVC insulated, 4 Sqmm FRLS copper conductor for earth continuity all as specified and as directed.
All as per item No 5 here in before but with 2 runs of 6 Sqmm for phase and neutral and 1 run of 6 Sqmm for earth wire complete.
All as per item No 5 here in above but with 2 runs of 10 Sqmm for phase and neutral and 1 run of 10 Sqmm for earth wire complete. NOTE FOR ITEM NO. 5, 6 AND 7: Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
Sub main wiring, complete with 4 runs of 6 sqmm, PVC insulated, unsheathed FRLS cable, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of PVC conduit pipe and accessories on surface/ wall/ roof etc. with two runs of PVC insulated, 6 sqmm FRLS cable, copper conductor for earth continuity conductor all as specified and as directed.
Sub main wiring, complete with 4 runs of 10 sqmm, PVC insulated, unsheathed FRLS cable, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of PVC conduit pipe and accessories on surface/ wall/ roof etc. with two runs of PVC insulated, 10 sqmm FRLS cable, copper conductor for earth continuity conductor all as specified and as directed. NOTE FOR ITEM NOS 8 AND 9: Four runs of main copper conductor, two runs of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
MCB DB, SPN, 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
MCB DB, SPN, 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
MCB DB, TPN, 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
MCB DB, TPN, 6 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB, TPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
MCB SP 6-32 Amps complete all as specified and directed.
MCB SPN 32 Amps complete all as specified and directed.
MCB SPN 63 Amps complete all as specified and directed.
MCB TPN 32 Amps complete all as specified and directed.
MCB TPN 63 Amps complete all as specified and directed.
Disconnection and removing the u/s MCB plug and socket unit and S&F Single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amps 240 Volts, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for taking out /for laying under ground cables/ pipes etc and getting out in soft/loose soil complete all as specified and as directed.
Supply and spreading fine river sand in trenches for cushioning of under ground cable complete all as specified and as directed. Note: Only punned thickness will be measured and paid.
Returning filling in soil including spreading, levelling, watering and well ramming in layers n.exc 25 cms complete all as specified and as directed.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
Unreinforced precast concrete cable cover class LV, Type I, flat, of size 250 mm x 150 mm x 40 mm for cable protection complete all as specified and as directed.
Relaying of old serviceable PCC cable cover class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection complete all as specified and as directed.
Taking down of LT XLPE/ PVC UG cable 1100 V grade including joints where required of various size from the trenches for finding out the fault complete all as specified and as directed.
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified and as directed.
All as per item No 29 here in before but of size 35 Sqmm 3.5 core
All as per item No 29 here in before but of size 25 Sqmm 4.0 core
All as per item No 29 here in before but of size 16 Sqmm 4.0 core
Disconnection and removing the unserveciable twin core service wire and S&F twin core Aluminium service wire of size 4 Sqmm unsheathed 1100 Volts grade complete with necessary fixing arrangements all as specified and as directed.
All as per item No 33 here in before but of size 6 Sqmm
Disconnection and removing the unserveciable MCCB & Supply and fix new MCCB with thermalmagnetic release Conform to IS/IEC 60947-2 & IEC 60947-2 4 pole, 415 V, 400 A, 50 Hz, breaking capacity of 36 KA, complete all as specified and as directed.
All as per item No 35 here in before but of capacity 250 A, 36 KA
All as per item No 35 here in before but of capacity 200 A, 25 KA
All as per item No 35 here in before but of capacity 100 A, 16 KA
All as per item No 35 here in before but of capacity 63 A, 16 KA
Disconnection and removing the unserveciable ACB and Supply and fixing ACB 4 pole, 415 V with thermal magnetic release (manual drawout type) of Capacity 630 Amps, complete all as specified and as directed.
Disconnection and removing the unserveciable ACB and Supply and fixing ACB 4 pole, 415 V with Manual drawout type with Microprocessor release of capacity 630 Amps, complete all as specified and as directed.
Disconnection and removing the unserveciable ACB and Supply and fixing ACB 4 pole, 415 V with Manual drawout type with Microprocessor release of capacity 800 Amps, complete all as specified and as directed.
BHEEMRAO PATIL CONTRACTOR
om sai enterprises
MAYUR ELECTRIC SERVICES
UNIQUE INDIA CONSTRUCTIONS
eurekaenterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .