| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC AMARPUR GOMATI TRIPURA | AMARPUR | GOMATI | TRIPURA | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.4 L+₹1.0 L (12.3%)Rejected-AOC DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | L2 | Rejected-AOC L2 |
Tender Value
₹8.3 L
EMD Value
₹16,505
Closing Date
24 Nov 2022, 2:00 pmClosed
DGM ED AmarpurTripura
As per the uploaded document
As per the uploaded document
2022_POWER_33931_1
DGM/EDAMP/2022-23/11
Open Tender
Electrical Works
Item Rate
60 days
As per the uploaded document
As per the uploaded document
7 documents required · 7 mandatory
₹1,000
₹16,505
As per the uploaded document
26 Dec 2022
14 Nov 2022
24 Nov 2022
14 Nov 2022
24 Nov 2022
16 Nov 2022
16 Nov 2022
Amount
Supply
8 mtr. Long PCC Pole
9 mtr. Long PCC Pole
8 mtr. Long Steel Pole
Painted Stay set complete HT 20sq. Mm
Painted Stay set complete LT 16sq. Mm
11 KV Stay/Guy insulator (Porcelin)
LT Stay/Guy insulator (Porcelin)
Stay wire 7/2.50 sqmm
Supply of fabricated Stay clamp pair of assorted size of MS flat (50x6mm) with double Coat of red oxide promer coated & 2 nos ISI marked machine made nut & bolts of Size 16x75 mm & washer for erection of stay set.
MS Channel (100 x 100x50x 6 mm )
MSl Channel ( 75 x 40x40x 6 mm )
MS Angle ( 65x 65x 6 mm)
11 KV 2 GOS(three phase Polymeric type)
11 KV 2 DOF (three phase Polymeric type)
11KV L.A (Polymeric 9KV, 5KA)
11KV Polymeric composite 45KN Disc Insulator
11KV Disc fittings(6/1/2.59 & 6/1/3.35)
11KV 320 mm CD polymer composite PIN iNsulator
ACSR Weasel(30.00Sq. Mm) Conductor
8 SWG G.I Wire
LT AB Cable(3x35+1x16+1x25) Sq. mm
LT Insulation Piercing Connectors(IPC) main 16-95 Sq. mm & tap 4 to 35(50) Sq.mm
Eye hook
Cable end Cap(25-35mm/50mm)
Service line Anchor clamp 18-50mm
Cable Ties
Pole Clamp(25-50mm)
Suspension Clamp Asembly with straps & Buckle(25-35 mm)
LT Dead End Clamp Assembly with Straps & Buckle(25-35 mm)
Distribution Box Three Phase(25 mm)
Nut & bolts 16X50 mm
Nut & bolts 16X75 mm
Nut & bolts 12X250 mm
Nut & bolts 12X300 mm
100 KVA Transformer(Three Phase)
11KV Danger plate
LT Danger plate
Supply of fabricated clamp of assorted size of MS flat (50x6mm) with double Coat of red oxide promer coated & 2 nos ISI marked machine made nut & bolts of Size 16x75 mm & washer for erection of stay set.
Rewireable porceliene Cut-Out 100Amps
Bimetalic Lugs(95Sq. mm)
PVC Single Core 16mm Sq.
PVC Single Core 70mm Sq.
Supply of 60 Kg Salt and 55 Kg Charcoal (For 1 Pit)
Supply of 2.5 mtr. Long 40 mm dia G.I Pipe(Make TATA JINDAL)
Erection
8mtr. Long PCC Pole at any kind of soil upto a depth of 1/6th of pole height in/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading etc as reqd.( PCC Pole 8 mtr long )
9 mtr. Long PCC Pole at any kind of soil upto a depth of 1/6th of pole height in/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading
8 mtr. Long steel Pole at any kind of soil upto a depth of 1/6th of pole height in/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading etc as reqd.( ST Pole 8 mtr long (SP 30)
Painted stay set complete direct in earth with 19 mm dia 1.8 mtr long painted stay rod ,anchor plate of size 300x300x8 mm ,thimble, turn buckle ,7/3.15 mm dia GI stranded wire & stain insulator insulator etc in/c supply of MS Clamp,Nut & Bolts etc asa reqd. & making complete in all respectas direction of Eng-in-charge (GI Stay set HT 20 sq mm)
Painted Stay set complete direct in earth with 19 mm dia 1.8 mtr long painted stay rod ,anchor plate of size 300x300x8 mm ,thimble, turn buckle ,7/3.15 mm dia GI stranded wire & stain insulator insulator etc in/c supply of MS Clamp,Nut & Bolts etc asa reqd. & making complete in all respectas direction of Eng-in-charge (GI Stay set LT 16 sq mm)
0.8 mtr long MS Channel (100 x 100x50x 6 mm ) for sub stn. etc
2.8 mtr long MS Channel (100 x 100x50x 6 mm ) for sub stn. etc
2.8 mtr long MS Channel ( 75 x 40x40x 6 mm )for sub stn. GO,DO fixing bkt. Etc
MS Channel ( 75 x 40x40x 6 mm ) 0.3 mtr long for single pole top cross arm
MS Channel ( 75 x 40x40x 6 mm ) 1.2 mtr long for single pole bottam cross arm
MS Channel ( 75 x 40x40x 6 mm ) 2.2 mtr long for single pole bottam cross arm
MS Angle ( 65x 65x 6 mm) 1.5 mtr long SP Guarding cross arm
MS Angle ( 65x 65x 6 mm) 2.8 mtr long DP Guarding cross arm
MS Angle ( 65x 65x 6 mm) 2.5 mtr long DP cross arm
11 KV 200 Amp GOS unit set of three nos inc. necessary connection complete as per technical specification (Excluding the cost of back clamp, nuts & bolts) 11 KV G.O.S (three phase)(Polymeric type)
11 KV DOF unit set of three nos inc. necessary connection complete as per technical specification (Excluding the cost of back clamp, nuts & bolts) 11 KV D O F (three phase)(Polymeric type)
9 KV, 5 KA single pole metel oxide gapless type LA, inc. necessary connection complete as per technical specification .11 KV Polymeric LA,9 KV,5KA
11 KV disc insulator with fittings, nuts & bolts, washers etc. as reqd. as per direction of Engineer-in-charge. (11 KV Polymer composite 45 KN Disc Insulator)
11 KV 320 mm CD Polymer composite PIN Insulator
Erection of ACSR weasel (30 Sq. mm ) Conductor Laying & stringing in/c hoisting & binding etc. complete as required
Erection of 8 SWG Gi wire Laying & stringing in/c hoisting & binding etc. complete as required
Erection of LT AB Cable (3x35+1x16+1x25) Sq. mm Laying & stringing in/c hoisting & binding etc. complete as required
Erection & fitting & fixing of LT Insulation Piercing Connectors (IPC) all sizes of 1.1 KV grade in/c connection from main cable to distribution box, Tee-Off line as per direction og Eng-in-charge.
Erection & fitting & fixing of LT Insulated Dead End Anchoring Clamp in/c pole clamp, Eye Hook for cable messanger of 1.1 KV grade PCC/ST pole with the help of pole brackets or Steel Straps & Buckle as per direction og Eng-in-charge.
Erection & fitting & fixing of LT Insulated Suspension Clamp in/c pole clamp, Eye Hook for cable messanger of 1.1 KV grade PCC/ST pole with the help of pole brackets or Steel Straps & Buckle as per direction og Eng-in-charge.
Erection & fitting & fixing of service main 3 phase distribution box of 1.1 KV grade PCC/ST pole with the help of pole brackets or Steel Straps & Buckle as per direction og Eng-in-charge.
Insttalation/ Positioning of 11/0.430 KV , 3 phase 100 KVA distribution transformer on pole with necessary connections & fitting & fixing of all allied assessories , components as redq. For making complete in all respect for energizing
Fitting & Fixing11KV Danger plate
Fitting & Fixing LT Danger plate
Fabrication of Steel Materials
Providing Sub-Station protective fencing by 75 x25 mesh of 2.5x3.5 mtr.and height of 1.5 mtr. As per Engineering recruitment by 01 nos. MS Angle post (50x50x6mm) of height 2.0mtr .Horizontal Bar 6x3.5 mtr and 6x2.5 mtr and vertical Bar 10x1.5 mtr of MS flat (35x6mm) and single part of MS Grildoor of size L-1.5 / B-1.2 mtr with locking arrangement including necessary grouding and painting by Aluminium paint over red oxide priming of approved quality as reqd . as per TS including supply of all materials (MS Angle will be supplied by the Deptt)
Erection Earthing with G.I pipe 2.5 mtr. Long and 40 mm dia, inc. excavation, refilling with alternate layer of salt & charcoal as per drawing (excluding supply of G.I wire, nuts & bolts, etc. as required).
Erection of protective guarding / cross lacing for 415/240 volt line by GI wire 98/10 SWG as per technical specificationacross road/river/telecom line etc.in horizontal/verticle formation complete with spool/Reel insulator
ADHIR DEBNATH
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .