Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.6 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹1.1 Cr+₹14.0 L (14.1%)Rejected-Finance CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹1.1 Cr+₹14.6 L (14.7%)Rejected-Finance 452 1 STREET NO 2A KAULAGARH ROAD RAJENDRA NAGAR DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹1.2 Cr+₹19.0 L (19.0%)Rejected-Finance 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹1.2 Cr+₹21.4 L (21.4%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Shikhar ji Enterprises L4 | R D Bansal L1 | BHARAT ELECTRICAL TRADERS L2 | BEHAL TRADERS L8 | TEAM ACC INFRABUILD PRIVATE LIMITED L7 | M/S SEWA AND SERVE BUILDERS L3 | Quality Builders L6 | SANJAY B SHARMA L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old unserviceable overhead Aluminium Conductor from the 9/11 Mtr long poles and deposit to MES store yard complete all as specified & directed by Engr-in-Charge. | 10 | Qtl | 450 ₹4,500 | 100 ₹1,000 Lowest | 100 ₹1,000 Lowest | 600 ₹6,000 | 8,000 ₹80,000 | 2,000 ₹20,000 | 500 ₹5,000 | 10,000 ₹1,00,000 |
| 2.00 | Taking Down old unserviceable Insulators, any type/size and deposit to MES storeyard complete all as specified & directed by Engr-in-Charge. | 500 | Each | 15 ₹7,500 | 1 ₹500 Lowest | 2 ₹1,000 | 20 ₹10,000 | 10 ₹5,000 | 10 ₹5,000 | 5 ₹2,500 | 100 ₹50,000 |
| 3.00 | Taking out Old unserviceable Cross Arms MS Channel Clamps/nut bolts etc and deposit to MES store yard all as specified & directed by Engr-in-Charge. | 8 | Qtl | 450 ₹3,600 | 100 ₹800 Lowest | 100 ₹800 Lowest | 600 ₹4,800 | 3,000 ₹24,000 | 2,500 ₹20,000 | 500 ₹4,000 | 5,000 ₹40,000 |
| 4.00 | Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked of size 500 Sq.mm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.
Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before the cable is laid.
(ii) Excavation & earth work will be measured and paid separately. | 50 | RM | 3,275 ₹1,63,750 | 2,290 ₹1,14,500 | 3,187 ₹1,59,350 | 4,000 ₹2,00,000 | 3,600 ₹1,80,000 | 3,800 ₹1,90,000 | 3,400 ₹1,70,000 | 2,000 ₹1,00,000 Lowest |
| 5.00 | All as per item 04 here in above but of Size 3.5 core 400 Sqmm complete all as specified & directed by Engr-in-Charge. | 435 | RM | 2,275 ₹9,89,625 | 1,840 ₹8,00,400 | 2,164 ₹9,41,340 | 3,000 ₹13,05,000 | 2,100 ₹9,13,500 | 2,640 ₹11,48,400 | 2,400 ₹10,44,000 | 1,530 ₹6,65,550 Lowest |
| 6.00 | All as per item 04 here in above but of Size 3.5 core 300 Sqmm complete all as specified & directed by Engr-in-Charge. | 275 | RM | 1,775 ₹4,88,125 | 1,570 ₹4,31,750 | 1,693 ₹4,65,575 | 2,400 ₹6,60,000 | 1,680 ₹4,62,000 | 2,025 ₹5,56,875 | 1,900 ₹5,22,500 | 1,000 ₹2,75,000 Lowest |
| 7.00 | All as per item 04 here in above but of Size 3.5 core 150 Sqmm complete all as specified & directed by Engr-in-Charge (from panels to Bldgs) | 100 | RM | 1,080 ₹1,08,000 | 850 ₹85,000 | 866 ₹86,600 | 1,400 ₹1,40,000 | 920 ₹92,000 | 1,120 ₹1,12,000 | 1,000 ₹1,00,000 | 750 ₹75,000 Lowest |
| 8.00 | All as per item 04 here in above but of Size 3.5 core 35 Sqmm complete all as specified & directed by Engr-in-Charge (from panels to Bldgs) | 900 | RM | 300 ₹2,70,000 | 238 ₹2,14,200 Lowest | 265 ₹2,38,500 | 350 ₹3,15,000 | 310 ₹2,79,000 | 310 ₹2,79,000 | 350 ₹3,15,000 | 500 ₹4,50,000 |
| 9.00 | All as per item 04 here in above but of Size 25 Sqmm 4 core complete all as specified & directed by Engr-in-Charge(from panels to Bldgs) | 900 | RM | 280 ₹2,52,000 | 229 ₹2,06,100 Lowest | 233 ₹2,09,700 | 275 ₹2,47,500 | 290 ₹2,61,000 | 260 ₹2,34,000 | 300 ₹2,70,000 | 500 ₹4,50,000 |
| 10.00 | All as per item 04 here in above but of Size 16 Sqmm 4 core complete all as specified & directed by Engr-in-Charge(from panels to St Lights) | 1,300 | RM | 180 ₹2,34,000 | 175 ₹2,27,500 Lowest | 178 ₹2,31,400 | 250 ₹3,25,000 | 210 ₹2,73,000 | 185 ₹2,40,500 | 270 ₹3,51,000 | 400 ₹5,20,000 |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
10 Sept 2025, 6:00 pmClosed
CWE (AF) BAREILLY
HQ Commander Works Engineers AF Military Engineer Services Bareilly 243002
AS DESCRIEBED IN BOQ
2025_MES_725245_1
81559/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) BAREILLY
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE (AF) BAREILLY
₹2.0 L
10 Oct 2025
8 Aug 2025
17 Sept 2025
8 Aug 2025
10 Sept 2025
29 Aug 2025
Amount
Taking down old unserviceable overhead Aluminium Conductor from the 9/11 Mtr long poles and deposit to MES store yard complete all as specified & directed by Engr-in-Charge.
Taking Down old unserviceable Insulators, any type/size and deposit to MES storeyard complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable Cross Arms MS Channel Clamps/nut bolts etc and deposit to MES store yard all as specified & directed by Engr-in-Charge.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked of size 500 Sq.mm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed. Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Excavation & earth work will be measured and paid separately.
All as per item 04 here in above but of Size 3.5 core 400 Sqmm complete all as specified & directed by Engr-in-Charge.
All as per item 04 here in above but of Size 3.5 core 300 Sqmm complete all as specified & directed by Engr-in-Charge.
All as per item 04 here in above but of Size 3.5 core 150 Sqmm complete all as specified & directed by Engr-in-Charge (from panels to Bldgs)
All as per item 04 here in above but of Size 3.5 core 35 Sqmm complete all as specified & directed by Engr-in-Charge (from panels to Bldgs)
All as per item 04 here in above but of Size 25 Sqmm 4 core complete all as specified & directed by Engr-in-Charge(from panels to Bldgs)
All as per item 04 here in above but of Size 16 Sqmm 4 core complete all as specified & directed by Engr-in-Charge(from panels to St Lights)
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 300-400 Sqmm 3 ½ Core XLPE complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out in any type of soil for laying of cables, etc of LT Cable and stay assembly all as specified and directed .
M&L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable all a specified. Note. Only punned thickness i.e. 18cm shall be measured & paid.
Supply & Laying well burnt sub class ‘B’ bricks (using old size brick) laid in trenches above sand cushioning for cable protection complete all as specified & directed by Engr-in-Charge
Returning, filling in (Soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50 Mtr depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed.
M&L for 40 mm bore of tubes light grade galvanised with all fitting laid in trenches or inserting in horizontal boring complete all as specified and directed.
M&L for 50 mm bore of tubes light grade galvanised with all fitting laid in trenches or inserting in horizontal boring complete all as specified and directed.
M&L for 100 mm bore of Tubes light grade galvanised with all fitting laid in trenches or inserting in horizontal boring complete all as specified and directed.
Horizontal Boring under hard standing/ pavements or roads manually using suitable auger for insertion of GI pipes with Cable of size upto 150 mm bore and making good the disturbed surface complete all as specified and as directed.[Note: GI pipe will be measured and paid separately]
M&L for earthing complete with galvanized earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground vertically at a depth not less than 2.25 mtrs below normal ground level with top edge of earth plate at a depth not less than 1.5 mtrs below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized iron strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers made of galvanized iron and protected by light grade 40 mm bore GI pipe upto test point or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit in 1:3:6 type C-2 (using 40 mm grade stone aggregate) including excavation and earth work in any type of soil, returning filling in soil and disposal of surplus soil to a distance not exceeding 50 mtrs all as specified and shown on plate No 03 of SSR Part-I Earthing all as specified and directed. Note-Galvanised Earth plate electrode of 600mmx600mmx6mm should be covered/surrounded by 15cm layers by charcoal and salt.
M&L for earthing complete with galvanized earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground vertically at a depth not less than 2.25 mtrs below normal ground level with top edge of earth plate at a depth not less than 1.5 mtrs below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized iron strip 4mm GI Wire by means of bolts, nuts, check nuts and washers made of galvanized iron and protected by light grade 15 mm bore GI pipe upto test point or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit in 1:3:6 type C-2 (using 40 mm grade stone aggregate) including excavation and earth work in any type of soil, returning filling in soil and disposal of surplus soil to a distance not exceeding 50 mtrs all as specified and shown on plate No 03 of SSR Part-I Earthing all as specified and directed. Note-Galvanised Earth plate electrode of 600mmx600mmx6mm should be covered/surrounded by 15cm layers by charcoal and salt.
S&F DBOXx MCB Protected socket with 25 A MCB DBOX x COMBO (With Sheet Steel Enclosure) with plug top, 25 Amp and socket with 25 Amp MCB 240 V complete all as specified and directed.
S&F Sheet metal enclosure for distribution box with single pole and neutral with single door 02 way without busbar 240 V, all as specified.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 25/32 Amps in the MCB DB complete with connection testing and commissioning all as specified and directed by Engr-in-Charge.
M&L for submain wiring alongwith earth wire of size 2x4.0 Sqmm + 1x4.0 Sqmm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor single core cable drawn in and including PVC concealed conduit 20 mm dia ISI marked, with all conduit accessories medium grade ISI marked as required as specified and directed. Note : Two run of PVC wire and one run of earth wire with one run of conduit will be measured and paid as one length.Note : cutting and filling of wall is included and make surface as before after work.
M&L for submain wiring alongwith earth wire of size 2x6.0 Sqmm + 1x6.0 Sqmm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor single core cable drawn in and including PVC concealed conduit 20 mm dia ISI marked, with all conduit accessories medium grade ISI marked as required as specified and as directed.Note : Two run of PVC wire and one run of earth wire with one run of conduit will be measured and paid as one length. Note : cutting and filling of wall is included and make surface as before after work.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with connected fittings complete all as specified and directed.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with connected fittings complete all as specified and directed.
Supply, and Installation of copper wound transformer step down, Indoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 Volts, 3 Phase 4 wire with off load tapping on HT side to vary secondary voltage within limit, all as per IS 2026 of capacity 630 KVA , All distribution Transformers Shall be of required capacity, Double copper wound ONAN type cooling with vector group, DYN-11 conforming to IS:1180 of 2014. 11/.433 KVA,3 Phase, 50 HZ, Dyn 11, outdoor ONAN type, copper wound step down distribution transformer off load tap changing arrangement on HV side in steps of +2.5%, +5% , +7.5% having cable box on HV & LV side suitable to accomodate HT/LT. The transformer shall be provided with all standard accessories and first fittings of filtered dehydrated transformer oil and conforming to Energy Efficiency Level 3 of IS-1180 (Part1) 2014 complete. The transformer shall have following accessories :-
(a) Oil Conservator with filling hole and drain cock. (b) Oil Level Gauge. (c) Oil seal type transparent breather with silica gel. (d) Two numbers earthing terminals with lugs. (e) Oil drain Valve/filter valve (f) Radiators with valves. (g) Lifting lugs with fastening holes. (h) Thermometer dial type 0-120 0C. (j) rating & Specification plate. (k) 4 Nos plain cast steel bi-directional detachable rollers. (l) Explosion vent with diaphragm & sight glass. (m) tranformers must have its neutral brought out for earthing on LV side. (n) Tranformers must be earthed by two independent earthings with GI Strips for body and another two independent earths for neutral. Neutral earthing of transformers should be done by using GI earth plate and GI earth strip. (o ) Transformer Shall be installed as described in IS-10028 (Part-II and in conforming with IE rule.
Note : (i) The oil temperature and winding temperature gauges shall be housed on a MS box shall be 0.6Mx0.6Mx0.3M with hinged door and having glass 3 mm thick front side of the box and provision for entry of cables and compression glands. (ii) Platform and fencing gate shall be measured and paid separately under relevant item. (iii) Anything missed out above but technically required for efficient working of transformer is deemed to be included in quoted rates. (iv) Transformer losses shall be within the tolerance limits as specified in IS 2026. (v) Transformer shall be tested by rep of Accepting officer before despatch from factory.
Supply Laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy Duty) with stranded aluminum conductor, 11000 Volts grade, of size 3 core 95 Sqmm complete all as specified & directed by Engr-in-Charge. .
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm.
S&F shock proof, rust proof, fire retardant non transparent Kiosk pole box of size 310 X 210 X 120 mm made of Engineering plastic one piece moulding, for out door duty, with four Nos. of insulated aluminium bus bar of 60 Ampere capacity mounted on unbreakable insulators, 10 Ampere MCB SP with aluminium lugs of suitable size up to 50 Sq.mm including 02 Nos. 40X3 mm flat iron clamps duly painted both side with two coats of synthetic enamel paint over a coat of red oxide primer, necessary suitable size nut-bolts, washers etc. complete all as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed cable, electric cables with stranded copper conductor of size 2.5 sqmm, 3 core, 1100 Volts grade round flexible connection wire as in electric connections complete all as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed cable, electric cables with stranded copper conductor of size 2.0 sqmm, 3 core, 1100 Volts grade round flexible connection wire as in electric connections complete all as specified and directed.
Supply and Fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm.
Supply installing, erecting commissioning and new factory made LT panel Board outdoor type, 415V, 3 phase & 4 wire system, cubical of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather / Dust proof made out of 3.15 thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with Bakelite sheet between bus bar & Separate cable alley with front side shutters with locking arrangement, including Copper bus bar insulated with colour coated heat shrinkable sleeve of rating not less than 1.5 times the rated capacity of the incomer MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh on back side of cable alley for the protection purpose. All type Test certificates and Design verification with switch gears (as per confirming to IS/IEC-61439/2011 part-I and part-2 with short circuit test at 65 KA should be submitted by the contractor before executing the job. The Bus bar shall be mounted on F clars insulators with intervals not more than 500mm. All inter connections between the main Bus bar as well as incoming / outgoing feeders shall be carried out with TPN Aluminum bus bars of rating not less than 1.5 times rated capacity of individual outgoing feeders.
Supply installing, erecting commissioning and new factory made LT panel Board outdoor type, 415V, 3 phase & 4 wire system, cubical of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather / Dust proof made out of 3.15 thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with Bakelite sheet between bus bar & Separate cable alley with front side shutters with locking arrangement, including Copper bus bar insulated with colour coated heat shrinkable sleeve of rating not less than 1.5 times the rated capacity of the incomer MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh on back side of cable alley for the protection purpose. All type Test certificates and Design verification with switch gears (as per confirming to IS/IEC-61439/2011 part-I and part-2 with short circuit test at 65 KA should be submitted by the contractor before executing the job
Supply installing, erecting commissioning and new factory made LT panel Board outdoor type, 415V, 3 phase & 4 wire system, cubical of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather / Dust proof made out of 3.15 thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with Bakelite sheet between bus bar & Seprate cable alley with front side shutters with locking arrangement, including Copper bus bar insulated with colour coaded heat shrinkable sleeve of rating not less than 1.5 times the rated capacity of the incomer MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh on back side of cable alley for the protection purpose. All type Test certificates and Design verification with switch gears (as per confirming to IS/IEC-61439/2011 part-I and part-2 with short circuit test at 65 KA should be submitted by the contractor before executing the job. The Bus bar shall be mounted on F clars insulators with intervals not more than 500mm. All inter connections between the main Bus bar as well as incoming / outgoing feeders shall be carried out with TPN Aluminum bus bars of rating not less than 1.5 times rated capacity of individual outgoing feeders.
Supply installing, erecting commissioning and new factory made LT panel Board outdoor type, 415V, 3 phase & 4 wire system, cubical of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather / Dust proof made out of 3.15 thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with Bakelite sheet between bus bar & cable alley with front side shutters with locking arrangement, including Copper bus bar insulated with colour coaded heat shrinkable sleeve of rating not less than 1.5 times the rated capacity of the incomer MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh on back side of cable alley for the protection purpose. All type Test certificates and Design verification with switch gears (as per confirming to IS/IEC-61439/2011 part-I and part-2 with short circuit test at 65 KA should be submitted by the contractor before executing the job. The Bus bar shall be mounted on F clars insulators with intervals not more than 500mm. All inter connections between the main Bus bar as well as incoming / outgoing feeders shall be carried out with TPN Aluminum bus bars of rating not less than 1.5 times rated capacity of individual outgoing feeders.
Supply installing, erecting commissioning and new factory made LT panel Board outdoor type, 415V, 3 phase & 4 wire system, cubical of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather / Dust proof made out of 3.15 thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with Bakelite sheet between bus bar & Seprate cable alley with front side shutters with locking arrangement, including Copper bus bar insulated with colour coaded heat shrinkable sleeve of rating not less than 1.5 times the rated capacity of the incomer MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh on back side of cable alley for the protection purpose. All type Test certificates and Design verification with switch gears (as per confirming to IS/IEC-61439/2011 part-I and part-2 with short circuit test at 65 KA should be submitted by the contractor before executing the job. The Bus bar shall be mounted on F clars insulators with intervals not more than 500mm. All inter connections between the main Bus bar as well as incoming / outgoing feeders shall be carried out with TPN Aluminum bus bars of rating not less than 1.5 times rated capacity of individual outgoing feeders.
Supply and fix MCCB 4 Pole 415V 16 KA with enclosure of breaking capacity ratings 63 Amps full load with sheet metal enclosure single door all as specified and directed.
Demolition of brick work built in cement mortar or cement lime motar including all quoins arches pillar etc complete all as specified and directed
M&L for providing cement concrete type C1 1:3:6 (20 mm graded aggregates ) in bed plates kerbs ,water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified & directed by Engr-in-Charge.
M&L for rendering 15mm thick in cement mortar 1:6 on fair face of brick work or concrete surface with surface finish even and smooth without using extra cement complete all as specified & directed by Engr-in-Charge.
M&L for rendering 10mm thick in cement mortar 1:6 on other than fair face of brick work or concrete surfaces with surface finish even and smooth without using extra cement complete all as specified & directed by Engr-in-Charge.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and or riveted or forged into spikes framed guards bars barred iron doors, ladders, framed balusters, walk ways: railing, framework of water tanks and similar work con-forming to Fe.290 Gde-E-165 complete all as specified & directed by Engr-in-Charge
S&F for wire netting stainless steel wire 25mmx 25mm of 1.4mm dia fixed with tinned tacks of stainless steel wire staples complete all as specified & directed by Engr-in-Charge
M&L for cutting holes in brick walls or cement lime mortar and stone walls built in lime mortar or walls of cement concrete superficial area not exceeding 150 Sqcm including making good to the existing work complete all as specified and directed.
S&F Mild steel, plain, black sheet of 1.25mm thick in wall cladding, steel gates and similar work, cut to size holes punched including round headed screws clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc as required complete all as specified & directed by Engr-in-Charge.
Supplying and laying of 50mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
M&L for painting to new steel surfaces of any description over 10cm width or girth, with two coats of synthetic enamel paint (1st quality) over one coat of primer including preparation of surface complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying two coat of cement base paint over one coat of primer complete all as specified and directed
M&L preparation of newly plastered surface on walls and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed
BHARAT ELECTRICAL TRADERS (BID ID -3415628)
M/S SEWA AND SERVE BUILDERS (BID ID -3421630)
Shikhar ji Enterprises (BID ID -3414909)
SANJAY B SHARMA (BID ID -3412805)
Quality Builders (BID ID -3415638)
TEAM ACC INFRABUILD PRIVATE LIMITED (BID ID -3416842)
BEHAL TRADERS (BID ID -3421023)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .