Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹6.7 LAccepted-AOC | l1 | Accepted-AOC L1 | |
| 2 | l2₹7.0 L+₹23,734.20 (3.52%)Rejected-AOC | l2 | Rejected-AOC L2 |
Tender Value
₹6.8 L
EMD Value
₹16,990
Closing Date
30 Nov 2019, 11:00 amClosed
Assistant Engineer
O/o of the Assistant Engineer , LSGD Engineering Wing Adoor Municipality.
Rewiring the Electrical Installation of Adoor Municipal office .
2019_LSGD_322056_14
P1/4561/19 sec
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
adoor
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,359
Yes
online
₹16,990
Yes
22 Jan 2020
20 Nov 2019
2 Dec 2019
20 Nov 2019
30 Nov 2019
20 Nov 2019
Amount
Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FR wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular typeROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Call bell point with 5A bell push at one end 6A ceiling rose at other end.
Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator.
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
Supply, conveyance, installation, testing and commissioning of pre-wired light fitting made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. (20 W LED light fittings [ Philips endura high efficency BN 10BC LED 20S CDL White 2000 Lumen ] )
Supply, conveyance, installation, testing and commissioning of pre-wired light fittings made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required. (20 W LED light fittings [ Philips endura high efficency BN 10BC LED 20S CDL White 2000 Lumen ])
Supply, installation, testing and commissioning of road lighting High power LED Luminaire with a lumen output of 3400lm and power consumption of 36W Integrated electronic gear. etc complete, giving connection and installing in the existing post. (BRP 409 LED CW 034 MR PC S1 PSU GR of M/s Philips make)
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).25 mm dia with HG company fabricated clamps
Supply and fixing the following types of superior quality 250V A.C call bell on wall and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.(Call bell)
Charges for cutting holes suitable for accommodating exhaust fans of sizes up to 305 mm sweep including plastering, colour washing etc. as required.
Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. (225mm light duty exhaust fan in metal frame)
Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
Supply and fixing angle / straight brass lined skirt type, bakelite batten holder without shade and giving connection etc as required
Supply and fixing shades of the following types of shades on existing batten / pendent/bracket fittings as required (200mm polished aluminium shade)
Supply and providing the following types and power rated lamps in the existing fittings as required( LED bulb 9W)
Supply and installation of suitable size MS rod type fan clamp as per IS 732 as required.(Supply and installation of suitable size MS rod type fan clamp as per IS 732 as required.)
Supply and installation of suitable size MS belt type fan clamp fabricated from MS flat (2 pieces) as per IS 732 as required.
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. (1200 mm sweep - 5 star rated)
Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required.(20 mm dia light gauge )
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required.(25 mm dia light gauge )
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required.(32 mm dia light gauge )
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.(1.50 sq mm 2 run)
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.(1.50 sq mm 4 run
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.(1.50 sq mm 6 run)
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.(2.50 sq mm 2 run)
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.(2.50 sq mm 4 run)
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.(2.50 sq mm 6 run)
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.(4.00 sq mm 2 run )
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.(4.00 sq mm 4run )
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.(6.00 sq mm 2 run )
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.(6.00 sqmm 4run )
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. (Cat 6 UTP Cable )
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (ROHS) (1 module moulded plastic box on surface)
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (ROHS) (3 module metal box in recess)
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (ROHS) (4 module metal box in recess)
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (ROHS) (9 module metal box in recess)
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) (1 module white/ off-white)
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) (3 module metal box in recess)
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) ( 4 module white/off-white)
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) ( 9 module white/ off-white)
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)( 6 A SP 1 way switch)
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)( 16 A SP 1 way switch)
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)(20 A SP 1 way switch)
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)(6 A Universal socket )
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)( 6/16 A socket )
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)( S&F Cat 6surface mountable outlet with spring shutter front access .Prefered make: Legrand/Amp)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required (Double pole enclosure for independent mounting of MCB/RCCB)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required (12 way single phase double cover (IP 42/43) )
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required (6 way (8+18) - three phase double cover (IP 42/43) )
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required (4 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) )
Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required ( 6-32A 10KA, SP MCB( C curve))
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) ( 32 A double pole mini break isolator)
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) (32 A, 10 kA, SP MCB (D curve))
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) ( 40 A, 4 pole, 30 mA RCCB)
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) (63 A, 4 pole, 30 mA RCCB)
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) (32A, 10 kA, TP MCB (C curve))
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) ( 40 A four pole mini break isolator)
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) ( 63 A, 10 kA, 4 pole MCB (C curve))
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in hard soil)
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required (300 x 300 x 10 mm cast iron gully trap with covering)
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.(2 x 25 x 3 mm tinned copper strip)
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.(3.15 mm bare copper conductor (10 SWG))
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.(2.00 mm copper conductor (14 SWG))
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required(2.65 mm copper conductor (12 SWG))
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.(3.15 mm copper conductor (10 SWG))
Supply and laying strips of the following sizes along with wiring/ cables and giving connection as required.(25 x 3 mm copper strip tinned at the points of contacts)
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.(2.00 mm (14 SWG)
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.(2.65 mm (12 SWG))
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.(3.15 mm (10 SWG))
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required (25 x 3mm brass bolt & nut)
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required (25 x 6 mm brass bolt & nut)
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of folowing size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.(HENSEL make/Syntex make) (600x300x214mm)
Supply and fixing the following accessories in the existing meter board and giving connections etc. (63 A, 415 V Backelite fuse fitting)
Supply and fixing the following accessories in the existing meter board and giving connections etc. (35/63A,bolted type offset tag types fuse link of size AIL.)
Supply and fixing the following accessories in the existing meter board and giving connections etc. (63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.)
Charges for dismantling existing ceiling fans scrapping,cleaning,overhauling and painting with suitable colour enamel paint and refitting in position.
Supply and renewing fan bearing .
Supply and renewing fan capacitor.
Charges for dismantling existing wiring and makes the walls in good condition,colour washing etc as required .
S&P iron hook [anchor bolt type] for binding service wire.
K J JOSEPH AND SONS ELECTRICAL CONTRACTORS AND ENGINEERS
Bidder Name
K J JOSEPH AND SONS ELECTRICAL CONTRACTORS AND ENGINEERS
JEBIN JOHN MG POWER CONTROLS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_446347.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .