Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹46.5 L+₹2.9 L (6.69%)Rejected-Finance VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹48.0 L+₹4.4 L (10.2%)Rejected-Finance VILL HAT PO DHARCHULA DISTT PITHORAGARH UK | DHARCHULA | PITHORAGARH | UTTARAKHAND | L3 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | M/s J P Traders L2 | M/s Karki Krishna Singh L1 | M/S TRILOCK SINGH AND SONS CONTRECTOR AND GOVERNMENT SUPPLIERS L3 |
|---|---|---|---|---|---|---|
| .05DESCRIPTION OF ITEMS | ||||||
| 1.00 | Demolition of cement concrete in ground floor,paving nexc 15cm thick(below or above GL) complete all as specified and directed | 14 | Cum | 300 ₹4,200 | 290 ₹4,060 Lowest | 500 ₹7,000 |
| 2.00 | M&L cement concrete work in pavement / hardstanding of flexural strength 40 kg/square centimeter in field using 400 kg of cement per cubic meter, thickness of concrete 25 cm or less all as spfd directed. | 12.5 | Cum | 1,000 ₹12,500 Lowest | 8,990 ₹1,12,375 | 10,000 ₹1,25,000 |
| 3.00 | M&L for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified. | 3.6 | Cum | 1,500 ₹5,400 Lowest | 9,000 ₹32,400 | 9,000 ₹32,400 |
| 4.00 | M & L cement concrete 1:2:4 type B2 (20mm aggregate) in surface channel complete all as specified and directed. | 0.5 | Cum | 1,600 ₹800 Lowest | 5,000 ₹2,500 | 9,000 ₹4,500 |
| 5.00 | Dismantling fencing wire mesh,any type complete all as specified and directed. | 366 | Sqm | 50 ₹18,300 | 20 ₹7,320 Lowest | 50 ₹18,300 |
| 6.00 | Dismantling post or struts (steel) any section, embedded in concrete etc including taking out embedded portion and making good the disturbed ground complete all as specified and directed. | 177 | RM | 100 ₹17,700 | 30 ₹5,310 Lowest | 40 ₹7,080 |
| 7.00 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. | 10 | Cum | 1,000 ₹10,000 | 800 ₹8,000 Lowest | 1,000 ₹10,000 |
| 8.00 | S&F MS posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as spfd and directed | 1,059.17 | kg | 50 ₹52,958.5 Lowest | 110 ₹1,16,508.7 | 145 ₹1,53,579.65 |
| 9.00 | All as per item no. 8 above but except material | 376.79 | kg | 50 ₹18,839.5 | 30 ₹11,303.7 Lowest | 40 ₹15,071.6 |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
29 Jul 2025, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post - Bharkatiya Pithoragarh - 262520
CERTAIN MISC REPAIRS TO ROOF TREATMENT, SECURITY FENCING, HARDSTANDING, SEWAGE LINE AND OTHER MISC WORKS AT MIL STN DHARCHULA.
2025_MES_717688_1
8683/PGH/E8
Open Tender
Civil Works
Item Rate
240 days
Dharchula
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹91,000
Yes
4 Sept 2025
30 Jun 2025
1 Aug 2025
30 Jun 2025
29 Jul 2025
15 Jul 2025
1 Jul 2025 - 8 Jul 2025
Amount
DESCRIPTION OF ITEMS
Demolition of cement concrete in ground floor,paving nexc 15cm thick(below or above GL) complete all as specified and directed
M&L cement concrete work in pavement / hardstanding of flexural strength 40 kg/square centimeter in field using 400 kg of cement per cubic meter, thickness of concrete 25 cm or less all as spfd directed.
M&L for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified.
M & L cement concrete 1:2:4 type B2 (20mm aggregate) in surface channel complete all as specified and directed.
Dismantling fencing wire mesh,any type complete all as specified and directed.
Dismantling post or struts (steel) any section, embedded in concrete etc including taking out embedded portion and making good the disturbed ground complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
S&F MS posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as spfd and directed
All as per item no. 8 above but except material
M & L for MS round bars (Fe-410-W (Gde E-250) quality A or Fe-290 (Gde-E-165)) 10mm dia and over cut to Length bent to shape required incl cranking, bending, spirally for hooping for columns with an including MS wire( Annealed not less than 0.90 mm Dia) or securing with clips complete all as specified and directed.
All as per item no. 10 above but except steel bars
Supply only chain link MS galvanised fencing any size and type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire complete all as specified and directed.
S & F Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting of any guage/thickness in roof covering/wall clading complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for 2 coats of synthetic enamel paint over one coat of red oxide on newly prepared steel surface of any description ,not otherwise description over 10cm width or girth complete all as specified and directed.
M & L preparing old previously treated surfaces of steel surface over 10 cm girth or width and applying one coat of synthetic enamel paint on old steel surfaces complete all as specified and directed.
Demolition of brick work, stone/boulder masonary built in cement mortar complete all as specified and directed.
M&L for Pre-cast cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed.
M&L for brick work with sub class 'B' brick old size bricks, straight or curved on plan exc 6 m mean radius, built in cement mortor 1:6 complete all as spfd & directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in C.M. 1:6, complete all as specified.
M&L Stone walling of random rubble, brought upto course, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
M&L Hand packing (any thickness) at back of walls with broken stone or boulders and raising (or lowering) to the required level complete all as specified and directed.
M & L for flush pointing to random rubble masonary, brought upto courses in CM 1:4 complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, of any description including raking out joints, hacking for key, scrubbing down with water, etc complete all as spfd and directed.
M&L 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces including finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surface including finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L three coats of white wash on wall surfaces including prepration of new plastered surfaces complete all as specified and directed.
Roughening surfaces of old concrete floor by picking ,sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M & L for 25mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregate) as in levelling course complete all as specified & directed.
M&L for vitrified ceramic light shade tiles/outdoor tiles 8-12mm thick (square or rectangular) polished area of each tile not exc.0 .36 sqm in floor,dado etc and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade complete laid over screed bed,rendering or bedding layer of mortar CM (1:6) 15mm thick complete all as specified and directed.
Taking down chowkhats or frame exc 1.5 sqm but nexc 4.00 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
S&F for mild steel framed wk as in doors or gates of angle iron,tubular or other section complete drilled for fixing of steel sheeting or other covering doors, etc to be prepared for hanging or sliding with & incl either hooks & hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running rails and slides) & hanging, also fastening & fixing Fe-290, Gde-165 complete all as spfd & directed.
S&F 1.00 mm th Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams,including bending or turning up, mitred angles, etc. as required complete all as spfd & directed.
S&F 100 mm mild steel but hinges medium weight,cold rolled complete all as specified and directed.
S&F 250mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts,four on bolt plate and two on staple plate and fixed complete all as specified and directed.
Demolition reinforced cement concrete in any description and in any position complete all as specified and directed.
M&L Slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like using cement concrete type B-0 1:2:4 complete all as specified and directed.
M&L for pre-cast reinforced cement concrete as in cover slabs (1:2:4) type B1 using 20mm graded stone aggregate complete after placing in position over septic tanks/ manhole covers etc complete all as specified and directed.
M&L RCC type B-1 (1:2:4)(using 20mm graded aggregate) as in columns, pillars, piers etc complete all as specified and as directed.
M&L RCC type B-1 (1:2:4)(using 20mm graded aggregate) as in beams, cantilever, lintels etc complete all as specified and as directed.
S&F Formwork to sides and soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surface of concrete complete all as specified and directed
M&L form work to sides and soffits of roof beams, lintels lever shelves,chajjas incl supports over hang etc rough finished surfaces of concrete flat all as specified.
M&L form work to sides of pillars, posts, struts, columns for rough finished surface of concrete complete all as specified and directed.
M & L mild steel TMT bars 6 to 8mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed
M & L mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and directed.
M& L for clearing blockage of WC/Gully/floor traps by Roding/pressure to clear blockage upto first man hole complete all as specified and directed. Note- (a) Contractor/Rep of the contractor has to collect the complaints on daily basis from incharge of complaint cell. b) The blockage of WC/Floor Trap/Gully Trap are to be cleared on the same day of the receipt of complaint.
M&L cleaning of existing septic tank and sewage well by closing the existing sewage system at last man hole. Removing man hole cover and dewatering the liquid waste by mechanical pumping. Removing the solid sludge by manually or by mechanical system up to the bottom of septic tanks and sewage well at any size incl depositing the solid sludge in the pit providing by digging in near by septic tank of appropriate size. Whole area to be covered with bleaching powderand covered by natural earth obtained from excavation after filling the solid sludge and making good completely hygienic and directed at site. Note: During the cleaning of soakage wells/septic tanks, alternate arrangement be made by contractor by temporary pumping arrangement for clearing continuous incoming sewage complete all as specifed and directed Note :- (i) The cost of excavation of pit, bleaching powder and RFR to cover the sludge shall deemed to be inclusive in rate quoted by the contractor. (ii) All the tools and plants including mechanical pump and other allied arrangements for making sewage line functional will be made available by the contractor with out any extra cost to the Govt.
M&L for Cleaning of sewage line blocked/filled with sludge (solid/semi solid) silt and any other waste by roding or any other means (without damage to sewage line ) manhole to manhole and well pushing and cleaning including removing the waste to a distance not exceeding 50 meter and burried into pit excavated upto 15 cm depth below the GL and cover with excavated soils after treating the sludge by spreading a fine layer of bleaching powder as directed to reduce the foul gased and refixing man hole cover slab in position for sewage line of dia upto 200mm and at any depth complete all as specified and directed. Note :- (i) The cost of excavation of pit, bleaching powder and RFR to cover the sludge shall deemed to be inclusive in rate quoted by the contractor. (ii) All the tools and plants including mechanical pump and other allied arrangements for making sewage line functional will be made available by the contractor with out any extra cost to the Govt.
S&F On site coventional LLDPE septic tank of total capacity of 3000 ltr designed to carry sewage and sullage water, incl excavation in any type of soil, 100mm PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and directed.
M&L for construction of Soakage well incl excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20m dia and 3.0m effective depth all as per CEBZ TD/309 SHT-1/4 to 4/4 complete all as specified and directed.
Dismantling of 200 mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S&F reinforced concrete pipes, class NP2, 200mm laid and jointed complete with collars, complete all as specified and directed.
M&L for concrete bed 1:4:8 type D-2 (Using 40 mm graded stone aggregate) as in drain pipes including packing under, and haunching against the side of pipes after the are laid and tested in 200 mm bore pipe, complete all as specified and directed.
Cutting into existing manholes for connecting new drains, of any dia making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete (1:2:4 ) type B1 using 20mm graded crushed stone aggregate finished smooth and reforming benching as required for 200 mm dia pipe complete all as specified and directed.
Excavation in trenches in hard/dense soil n.exc 1.50 m deep and 1.50m wide or shafts, manhole etc n.exc 10 Sqm on plan and n.exc 1.50m deep and getting out complete all as specified.
Returning, filling in trenches, including spreading, leveling watering and wall ramming in layers each n.exc 25cm in hard/dense soil complete all as specified and directed.
Removal of surplus spoil to a distance n.exc 50m and depositing where directed at a level n.exc 1.50 m above the starting point complete all as specified and directed.
M&L for brick work built in cement mortar (1:4) using sub class ‘B’ bricks (old size) straight or curved in plan, exc 6.00 m mean radius complete all as specified and directed.
M&L for extra forming, fair, finished, drain or channel, 30cm inner girth in cement concrete using extra cement complete all as specified and directed.
S&F in repair Low Level Flushing cistern PVC valveless syphonic action type, 10 ltrs capacity including supply pipe & fixing with the help of rawl plugs on walls etc complete all as specified and directed.
S&F in repair Vitreous China Wash down water closet EWC with plastic seat cover complete all as specified and as directed .
S&F in rep vitreous china squatting pan "Orissa pattern" size 580 mm x 440 mm white with integral foot rests, incl provn of lime concrete bedding complete all as spfd & directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
S&F PVC (SWR)110 mm bore pipes single socketed, in any length with rubber ring joints,laid in trenches or fixed to walls complete all as specified and directed.
S&F PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints,laid in trenches or fixed to walls complete all as specified and directed.
S&F 110 mm bore PVC(SWR) bend any radius complete all as specified and directed.
S&F 75 mm bore PVC(SWR) bend any radius complete all as specified and directed.
S&F in repair PVC (SWR) junction single, (Single T) equal or unequal, 110 mm bore with access door complete all as specified and directed.
S&F in repair PVC (SWR) cowl, 75 mm bore complete all as specified and directed.
S&F in repair PVC (SWR) cowl, 110 mm borecomplete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, chajja, fins facia etc mixed with water proofing compound (ISI marked) as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified. complete all as specified and directed by Engr-In-Charge. Note 1: - Supply only water proofing compound shall be measured and paid for separately. 2. Cost of scafolding upto 2 storied height of building for rendering is included in this item.
M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-In-Charge.
M&L for non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm and not exceeding 0.18 sqm, in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified and directed by Engr-In-Charge.
M&L for coloured glazed ceramic tiles in vertical surface, 450x350x7mm thick set and jointed in neat sement slurry and pointed in white or colour cement to match over 10 mm thick plaster in CM 1:4 complete all as spfd & directed.
M&L for colored chequered cement concrete tiles 30cm x 30 cm x 20 mm thick set, jointed and pointed in neat cement slurry with grey cement and pigments in floor including 20 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
M&L for Removing /cutting trees & vegetation, digging out roots from concrete or brick wall ,filling holes on building (upto double storey) wall / roof / chhajja / water tank staging area etc and making good in cement mortar 1:4 complete all as specified and directed.
Demolition of (unreinforced) cement concrete of any description and in any position not otherwise specifically provided for and removing rubbish off the MD land complete all as specified and directed.
Deleted
Demolition of (reinforced) cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work of any description and in any position incl cutting of reinforcement for binding etc complete all as specified and directed.
M&L for Formwork to fair finish flat surface of fins, louvers, fascia complete all as specified and directed.
M&L for Formwork to fair finish curved surface of fins, louvers, fascia complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded aggregate) flat or curved fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and directed.
Dismantling /taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing the dismantled debris to a distance exc 200 m and n.exc 250 m complete all as specified and directed
M&L APP based polymeric membrane minimum weight 3kg/sqm and minimum 2mm thick reinforced with polyster non-woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application method with minimum side overlap 100mm and 150mm as end lap over roofs after cleaning the surfaces properly with water and allowed to dry completely including priming surfaces for applying heavy treatment complte all as specified and directed.
M&L rendering 15 mm thick (avg) on concrete surfaces over roof slabs, in cement mortar 1:4 mixed with liquid water proofing compound as per manufaturer's instructions, finished even and smooth without using extra cement, to receive roof treatment complete all as specified and directed . (Note - water proofing compound shall be measured and paid saperately)
M&L for surface of any description over 10 cm width or girth not other wise described and applying a coat of aluminium paint complete all as specified and directed.
Supply only liquid water proofing compound.
S&F 0.63 mm th galvanised corrugated mild steel sheeting with two corrugation side lap fixed with 'L' type or 'J' type or cranked hook bolts class 8 complete all as specified and directed.
S&F 0.50mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters,drip and straight flashings length and girth as fixed with 'L' type or 'J' type or cranked hook bolts class 8 complete all as specified and directed.
Taking down chowkhats or frame nexc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Supply and fix Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing all as specified and directed.
Supply and fix Factory made solid panel PVC door shutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be cov-ered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as specified and directed.
Supply and fix Extruded aluminum alloy handle, fabricated type, anodized 125mm size, complete all as specified and directed.
Supply and fix Aluminum, anodized, barrel tower bolts of extruded section 150 mm long, complete all as specified and directed.
Supply and fix Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed 100 mm in size complete all as specified and directed
S&F for Powder coated Anodised aluminium frame for doors, windows ventilator with one or more rebates including joining cleat for fixing etc , screws, hinges, brackets, dash fastners/rawl plugs etc. complete all as specified and directed.complete all as specified and directed.
S&F powder coated aluminium door shutters, aluminium section weighing min. 0.55 Kg/m including necessary jointing cleats glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed
S&F powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars aluminium sections weighing min 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100 mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel covr, governing pivo made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or descrption) from metal frame including punching or driling outold glazing pins/springs complete all as specified and directed..
S&F 4.80 mm thick sheet glass ordinary quality and glazing with oil putty/rubber packing in square exc .50 sqm in each panels complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repairs vitreous china wash basin of size 550X400mm white flat back with full pedestal of height 800 to 830 mm, incl 32 mm size chromium plated waste fitting and waste pipe fixed to wall with fastener / rawl plugs complete all as specified and directed.
S&F in repair plastic water closet seat cover, white/ black closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device all as specified and directed by Engr-in-charge.
S&F in repair 15 mm bore bib taps,chromium plated fancy type ,screwed down, screwed for iron pipe or for brass ferrule complete all as spfd & directed.
S&F 20 mm bore GI tubing with all fittings medium grade fixed to wall or laid in floor etc including taking down old pipe, complete all as specified and directed.
Supply and fix 500 Ltr rotational moulded polyethylene water stotage tanks ( cylinderical verticle with closed top) hoisted & fixed in position incl 20 mm brass float valve complete including dismantling water tank capacity exc 250 ltrs but nexc 500 ltrs and removing to stores complete all as specified and directed
Supply and fix 1000 Ltr rotational moulded polyethylene water stotage tanks ( cylinderical verticle with closed top) hoisted & fixed in position incl 20 mm brass float valve complete including dismantling water tank capacity exc 500 ltrs but nexc 1000 ltrs and removing to stores complete all as specified and directed
Supply and fix in repairs gun metal, globe or gate vlave 20mm dia bore with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc all as specified and as directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and gastenings and heavy brackets framing (beam, tee, angle channel or flat sections) (Fe-290 Gde E-165) inicluding distance pieces, cleats etc complete all as specified and directed.
S&F in repair 20 mm bore Ball brass valves, high pressure, with polythene float , brass coated rod and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair 25 mm bore Ball brass valves, high pressure, with polythene float, brass coated rod and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
M & L preparing old previously treated surfaces of corrugated/plain sheets as in roof covering /wall over 10 cm girth or width and applying one coat of synthetic enamel paint on old steel surfaces complete all as specified and directed.
M & L preparing old previously treated surfaces of corrugated/plain sheets as in roof covering /wall over 10 cm girth or width and applying two coat of synthetic enamel paint on old steel surfaces complete all as specified and directed.
M &L for preparation of old plastered surfaces of walls and applying one coat of oil emulsion distemper any tint of walls complete all as specified and directed.
M&L for preparing surfaces, plastered or unplasterd old/new decorated wall surfaces and applying two coat of oil emulsion distemper over a coat of wall putty of 1mm thckness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
M&L for preparing newly plastered surface of wall apply two coat of cement base paint over a coat of white wash complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
Supply and Fix in replacement tank lid made of mild steel with hinges on one side & locking facility on another side/ or with thread and covered with barbed wire for water tank of capacity upto 1000ltrs complete all as specified and directed.
M&L for water proofing treatment of roof comprising of following complete all as specified and directed :- (a) Clean the roof surface to remove any loose/unsound material dirt. Dust etc with mechanical means i.e. wire brushing/air blower and finally vaccum cleaned off all loose solid & liquid etc, cleaned surface should be pre-wet with water adequately. (b) Applying a bonding coat of SBR latex based polymer Dr Fixit URP(or equivalent of other make) conforming to ASTM C 190/85/881 and cement in ratio of 1:1.5 by volume @ 4.0 sqm/kg/coat along the junction of parapet walls and RCC roof and making of coving with cement sand mortar 1:3 admixed with liquid intergral water proofing compund Dr Fixit LW conforming to IS 2645-1983 @200ml/50kg bag of cement. Contd.......
(c) Apply one primer coat of acrylic based polymer Dr Fixit new coat(or equivalent of other make) confirming to ASTM C-836/1202, ASTM D-2240/412/4541, ASTM - E-96. ASTM-G-154 and water in 1:1 [email protected]/Kg/coat with roller or paint brush on RCC roof surface and allow it to dry. The primer shall be carried upto full height at parapet wall. (d) Apply in second coat of acrylic based ploymer Dr Fixit new coat (or equivalent of other make) conforming to ASTM C-836/1202, ASTM D-2240/412/4541 ASTM-E-96, ASTM G-154 and water in 1:1 rato @ 2.0Kg/Coat with roller or paint brush on RCC roof surface and allow it to dry. The water proofing coating shall be carried out up to full height at parapet walls. Note-The quoted rate deemed to be included for applying a bonding coat of SBR latex based repair polymer Dr Fixit UPR conforming to ASTM C190-85/881 and cement in the ratio of 1:[email protected] sqm/Liter/coat and repairing the damaged areas, drainage areas [pipes/points/khurras etc] with cement mortar 1:3 admixed with SBR latex based repair polymer Dr Fixit URP @ 10 Litre/50 kg bag of cement mix and repairing the cracks/holes etc with single pack polyurethane sealant of Dr Fixit conforming to ASTM C-920-S and allow to cure completely.
M&L for sunken floor treatment as described as under (i) to (vi) :- (i) Demolition of cement concrete of any description and in any position not otherwise specifically provided or in any type,filled in sunken portion & cleaned the sunken portion incl dismantling plastering wall surface complete as directed. (ii) M& L 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:3) 15 mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time complete all as specified and directed. (iii) Spouts of 40mm dia GI pipe medium grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed as specified and directed. Contd.....
(iv) After laying sewage/ plumbing pipes with fixtures in position 2 coats of EP-101 epoxy compound shall be applied complete all as specified and directed. (v) The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed, the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated. (vi) The sunken floor shall again be filled with PCC (1:5:10) type E-2 using over the treated surface upto top for fixing of WC complete all as specified and directed. Note - Mode of Measurement (i) Sunken slab to be treated up to 450 mm depth. (ii) Bottom area of sunken slab will only be measured for qty calculation and payment.
Dewatering and pumping out of existing accumulated sludge from Bar screen chamber and oil and grease chamber at STP by using external sewage disposal pump set to near by sewage disposal drain and cleaning of tank by scrapping with wire brush or any other means of on walls and bottom of tank and removing the sludge/ slits/ sand/fungus etc deposited inside the sumps/ tanks with buckets and depositing where directed followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing "Tank Cleaned (date) and due date with 10 Cm size white colour letter" on Black back ground on external walls complete all as specifoed and direted. Note :- (i) Contractor is to arange own diesel pump T&P etc for cleaning purpose and minor spares and cunsumable like small screws washers cleaning agents consumable etc is deemed to be included in the cost the unit rate quoted deemed to be include all safety precaution to be taken while working in STP. Contd.....
(ii) The accumulated/ deposied sludge after drying shall be disposed off out side the defence land to a distance not exceding 8.00 KM from the STP cost of which shall be deemed to inclusive in the quoted rate and nothing extra shall be paid on this account. (iii) Before commencement of work necessary arangement for disposal of sewage/ sludge be made and work to be caried out in fast pace by developing more man power at STP in Order to complete the work at the earliest. (iv) cleaning of sludge shall be carried out 2 times with internal of the mouth each cleaning shall be measured as one each job.
All as per item No 129 above but for Equilization tank of STP
All as per item No 129 above but for Rapid mix/flocculator tank at STP
M&L for cleaning of STP area by means of debris cutting of grass plant growth and disposed off up to a distance not more than 100 mtr from starting point all as per disrected at various pump houses under zone 'B' area
All as per item No 129 above but for FAB/MBBR tank at STP
All as per item No 129 above but for Tube settler Tank at STP.
All as per item No 129 above but for Chlolrine Contact Tank
All as per item No 129 above but for sludge Holding Tank at STP
M&L for cleaning/ roding of choked pipe line of any size by manually or mechanical sucking rodding including cutting trading welding of pipe lines and testing for no leakage/ functionablity all as directed by Engr-in-charge.
All as per item No 129 above but for treated water tank /Clear water Tank at STP.
Servicing of Air blower ,positive displacement type ,twin lobe type of any make of capcity 400 Cum/hr after removing from its installed position by disconnecting suction and delivery silencer air delivery pipe disconnecting electric cables earth strips and dismounting the compressor and motor from base channel and overhauling of compressor by opening the compressor replacing the worn out/ defective spare parts making good of shaft and shaft sleeve diening internally lubricating the rotating parts reassembling the compressor duly replacing with new packing material 'O' rings worn out bolts nuts washers belt belt guard etc and bring back and reinstalling in its orignal position checking alingment reconnecting the suction and delivery silencer air delivery pipe and electric connections testing on completion for satisfactory performance complete all as directed.
M&L for removing the Submersible pump set with motor from existing position shifting for repair work dismantle/ open removing the burnt winding cleaning of rotor/ stator rewinding the motor with 'F' class insulation super enameled cooper wire of size equivalent to the orignal winding insulated packing materials varshning drying incl replacement of both water seal compound both bearing fill with new etc reassambling the pump set installing back to the orignal position testing and comissioning to the full load for 4 Hrs continous running for the motor cap of motor upto 5.0 HP complete all as specified and directed.
Lifting and taking out the sewage submersible pump set and motor for servicinfg of capacity 5 HP including delivery pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sewage sump /well and lowering back the pump after repairing and removing the sludge from the pump including making electrical connection with the existing panel /starter and connecting the complete the delivery pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as specified and directed.
Material and labour for removing the mono Block/ non clogging centrifugal pump with motor of capacity 7..5 HP from its existing position including delivery pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of cable complete for servicing/ repairing the pump including making electrical connection with the existing panel /starter and connecting the complete the delivery pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed.
M&L for dismantling and removing the mono Block/ non clogging centrifugal pump with motor from existing position and shifting for the repair work removig the burnt winding cleaning rotor/ stator re-winding the motor with super enameled cooper wire of size equivalent to the orignal winding incl isulate packing materils varnishing drying etc installed back to the orignal position testing and commisoning on full load for 4 Hrs continous running for the capacity of motor upto 7.5 HP complete all as specified and directed.
Material and labour for removing the mono Block/ non clogging centrifugal pump with motor of capacity 20 HP from its existing position including delivery pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of cable complete for servicing/ repairing the pump including making electrical connection with the existing panel /starter and connecting the complete the delivery pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed.
M&L for dismantling and removing the mono Block/ non clogging centrifugal pump with motor 20 HP from existing position and shifting for the repair work removig the burnt winding cleaning rotor/ stator re-winding the motor with super enameled cooper wire of size equivalent to the orignal winding incl isulate packing materils varnishing drying etc installed back to the orignal position testing and commisoning on full load for 4 Hrs continous running for the capacity of motor upto 7.5 HP complete all as specified and directed.
Material and labour for removing the mono Block/ non clogging centrifugal pump with motor of capacity 100 HP from its existing position including delivery pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of cable complete for servicing/ repairing the pump including making electrical connection with the existing panel /starter and connecting the complete the delivery pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed.
M&L for dismantling and removing the mono Block/ non clogging centrifugal pump with motor upto 100 HP from existing position and shifting for the repair work removig the burnt winding cleaning rotor/ stator re-winding the motor with super enameled cooper wire of size equivalent to the orignal winding incl isulate packing materils varnishing drying etc installed back to the orignal position testing and commisoning on full load for 4 Hrs continous running for the capacity of motor upto 7.5 HP complete all as specified and directed.
M&L for repair, servicing, fixing, testing and commissioning of existing 0-6 LPH electrically operated, metered, adjustable dosing pump with accssories including replacement of lead tubing/dosing tube, connecting nuts & injection check valve and fixing with existing 500 ltr FRP tank fitted complete all as directed by engineer -in - charge. Note : Cost of PVC dosing tube, foot valve for the suction side and LDPE discharge tube, adjustable valve in PVC with EPDM seals for the discharge line deemed to be included in the quoted rate.
Material & labour for Cleaning of filter medial tank (ACF & DMF), pumping out all sludge and foreign material including washing the entire tank and scraping the walls with wire brushes and making good the patches on walls internally or externally where required all as specified and directed by Engr-in-Charge.
Supply only DWPE chemical for sewage treatment plant.
Material and labour for replacement of quartz silica sand 32-64 grade complete all as specified.
Material and labour for replacement of quartz silica sand 16-32 grade complete all as specified.
Material and labour for replacement of quartz silica sand 8-16 grade complete all as specified.
Material and labour for replacement of quartz silica sand 4-8 grade complete all as specified.
Material and labour for replacement of activated carbon IV 1000 complete all as specified.
Taking out complete pebbles from the filter and and refilling the same pebbles after washing /cleaning thoroughly complete all specified and directed.
Supply and mixing of calcium hypochloride having 70% chlorine content etc required at site and all as directed by the Engineer-in-Charge.
Supply and mixing of Poly aluminium chloride 100% purity etc required at site and all as specified.
Material & labour for carrying sample testing of sewage water as per relevant IS of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as recommended by AGE. (a) Carrying out minimum essential testing of sewage water as per relevant IS mandatory for chemical, odour, PH value,TSS, BOD, COD, total nitrogen, sulphate, oil and grease, ammonical Nitrogen (NH3-N) and Bacteriological total colliform organism and other characterstics as per relevant IS of sewage water. (i) Cost of sterilized bottle as required. (ii) cost of sample collection from Site to laboratory including transportation charges deemed to be included in the quoted rate.
Material & labour for carrying sample for testing of treated water of STP and submission of detailed test report to the office of the Engineer-in-charge. Details are as under : a) carrying out minimum essential testing of treated water as per IS 3025 & IS 1622 mandatory for chemical , colour, odour, PH value, TSS, BOD,COD, Total residual chlorine, total Nitrogen, sulphate, oil and grease, Ammonical nitrogen(NH3-N) and Bacteriological total coliform organism per 100ml (MPN) and Ecoli in 100ml. (b) Treated sewage water shall confirm to the following characterstics:- (i) TSS : < 10 mg/litre. (ii) BOD : < 10 mg/ litre. (iii) COD: < 150 mg/litre. (iv) Ph: 6.5 -8.5. (v) Total coliform: < 100 MPN/100 ml (desired nil). (vi) Resudual CI> 1 mg/litre. Rest of the characterstic of the treated water shall be as per IS 3025 & IS 1622. (i) Cost of sterilized bottle as required. (ii) cost of sample collection from Site to laboratory including transportation charges are included in the quoted rate.
Supply, laying , jointing, welding & testing MS pipe ( Heavy duty Class 'C') including fitting as required of following sizes laid in treches, laying on floor or wall for connecting to various STP accessories and to connect outgoing water main from Non clogging submersible pump including taking down the unserviceable pipe all as directed by Engr-in-charge. Note:- MS flange and flange joint, bends etc complete with jointing material shall deemed to be included in the unit rate of this item. (a) 50 mm bore
(b) 40 mm bore
Material & Labour for High density polyethylene pipes (HDPE) of size 50mm of pressure rating 6 Kgf/cm2 fixed complete laid in trenches etc complete all as specified and directed.
Supply and fix in butterfly valves suitable for GI/MS pipe complete including dismantling the old one all as specified and as directed by Engr-in-Charge for the following sizes :- (a) 80 mm bore
(b) 50 mm bore
Supply and fix in pressure gause for measuring pressure of air blower of cap 400cum/hr complete including dismantling the old one all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of flat submersible 3 core 6 sqmm cable PVC insualted unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
Supply and fix in replacement of cast iron pipes with spigot and socket ends centrifugally cast 150mm dia size Class LA, in any length, laid in trenches all as specified and as directed.
M&L for CI fitting for spigot and socketed pipes such as bends (any type, radius and angle) Tapers any type (straight, bend, increasing or double socket etc) Tee pieces single branch 'Y' juction double branch cross (all sockets or socket and spigot) collars, caps and plugs of any size complete all as specified and as directed.
Cutting existing pipe any size bore laid in position for taking out branch connection by inserting of new tee and coller including threading in existing and new pipe etc.complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 1,62,803.88 will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/s J P Traders (BID ID -3374253)
M/S TRILOCK SINGH AND SONS CONTRECTOR AND GOVERNMENT SUPPLIERS (BID ID -3376146)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .