Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹22.2 L+₹2.4 L (12.1%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹22.2 L+₹2.4 L (12.1%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹23.5 L+₹3.7 L (18.5%)Rejected-Finance DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹24.0 L+₹4.2 L (21.1%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹25.7 L
EMD Value
₹51,500
Closing Date
2 Jun 2023, 6:00 pmClosed
Garrison Engineer (I) (CG) Goa
Garrison Engineer (I) (CG) Goa HQ Coast Guard DHQ-11 Chicolna PO- Bogmalo Goa 403806
REPAIRS AND REPLACEMENT OF INTERNAL WIRING AND REPAIR TO CEILING FAN, EXHAUST FAN AND MISC WORKS UNDER CG DHQ 3 MANGALORE UNDER GE(I)(CG) GOA
2023_MES_593077_1
8356/GOA/E8
Open Tender
Miscellaneous Services
Item Rate
180 days
CGDHQ 3 MANGALORE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (I) (CG) Goa
₹51,500
Yes
27 Jun 2023
3 May 2023
6 Jun 2023
3 May 2023
2 Jun 2023
18 May 2023
3 May 2023 - 10 May 2023
Amount
Taking down carefully unserviceable/burnt copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, socket etc to be measured separately), and keeping aside for taking in account of credit and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M & L Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic PVC conduit with all accessories such as internal bend, end caps, etc complete fixed on walls/ceiling/roof/etc by means of suitable GI saddles/Spacers and including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor, fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in walls with 3mm thick bakelite top cover sheet, ISI maked with chromium plated screws and cup washers for housing the switches , socket outlets, fan regulators etc, complete all as specified and directed. for the following :-
(a) One light point controlled by one, one way switch.
(b) One fan point controlled by one, one way switch and regulator.
(c) One 3 pin socket outlet point controlled by one 06 Amp switch on independent board.
(d) One 3 pin socket outlet point controlled by one 06 Amp switch on same board.
(f) One call bell/buzzer point controlled by one bell push switch.
All as per item No. 2.00 described here-in-before but with copper conductor cable FRLS 2.5 Sqmm for one 3 pin socket outlet, 16 Amps and including provision of FRLS 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board complete all as specified and directed.
S & F in repairs Switch Piano flush button single pole one way 6Amps complete all as specified and directed.
S & F in repairs socket outlet, 5 pin 06 amps flush type complete all as specified and directed.
S & F in repairs switch socket combination 06 amps flush type complete all as specified and directed.
S & F in repairs switch socket combination 16 Amps flush type universal complete all as specified and directed.
S & F in repairs five step type fan regulator, 230 volts, AC, flush type on the existing phenolic lamination sheet etc as required complete all as specified and directed.
S & F in repairs bell push flush type 06 Amps complete all as specified and directed.
S & F in repairs call bell, ding dong, electric AC 230 Volt complete all as specified and directed.
S & F in repairs ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and directed.
S & F in repairs modular switch 6A single pole, one way, 1 module,complete all as specified and directed. [Make: Anchor Roma Cat No. 21011 & Cona trump Cat No.15001 or similar make mentioned in Particular specification]
S & F in repairs modular socket, 6A, 2 in 1, 2 module in Legrand, SSK]. [Make: Anchor Roma Cat No. 30373 & Cona trump Cat No.15091 or similar make mentioned in Particular specification]
S & F in repairs modular switch 16A, one way, 1 module complete all as specified and directed. [Make: Anchor Roma Cat No. 21066 & Cona trump Cat No.15051 or similar make mentioned in Particular specification]
S & F in repairs modular socket 06/16A, heavy duty 2 module complete all as specified and directed. [Make: Anchor Roma Cat No. 30828 & Cona trump Cat No.15101 or similar make mentioned in Particular specification]
S & F in repairs modular Fan step regulator, ISI marked - 2 module complete all as specified and directed. [Make: Anchor Roma Cat No. 20507 & Cona trump Cat No.15021 or similar make mentioned in Particular specification]
S & F in repairs modular bell push 6A single pole one way, with neon, 1 module complete all as specified and directed. [Make: Anchor Roma Cat No. 21055 or similar make mentioned in Particular specification]
M & L for Sub main wiring complete with 2 runs of 4 sqmm and one run of 4 sqmm as earth continuity conductor, drawn through in and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories fixed on wall/Ceiling/Fixed to roof/truss etc including taking down unserviceable submain wiring of any size including GI/Copper earth continuity conductor complete all as specified and directed. [ Note:- 2 run of main wire & one run of earth wire alongwith conduit and accessories shall be measured and paid in one run]
M & L for Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 01 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through in and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories fixed on wall/Ceiling/Fixed to roof/truss etc including taking down unserviceable submain wiring of any size including GI/Copper earth continuity conductor complete all as specified and directed. [ Note:- 2 run of main wire & one run of earth wire alongwith conduit and accessories shall be measured and paid in one run]
S & F in repairs wall mounted LED batten, 20W decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly,energy efficient including taking down carefully old unserviceable light fittings any type size complete and making good the disturbed surface of wall, roof, ceiling etc complete all as specified and directed.
S & F in repairs wall mounted LED batten, 10W decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly,energy efficient including taking down carefully old unserviceable light fittings any type size complete and making good the disturbed surface of wall , roof, ceiling etc complete all as specified and directed.
S & F in replacement of PVC switch board 100 x 100 mm suitable for fixing of switch and socket by cutting of suitable size incl taking down old unserviceable complete all as specified and directed.
All as per item No 22.00 but in 100 x 175 mm size complete all as specified and directed.
All as per item No 22.00 but in 150 x 200 mm size complete all as specified and directed.
M & L replacement of PVC casting & caping 20/12 mm including taking down old unserviceable complete all as specified and directed.
S & F in repairs replacement LED lamp (Bulb) 9 watt including taking down old unserviceable complete all as specified and directed.
S & F LED luminaire (2' x 2' ) 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size including taking down old unserviceable complete all as specified and directed.
S & F LED Aesthetically designed, 2' x 2' (600 x 600 mm) 42 watt, 220 V AC LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination including taking down old unserviceable complete all as specified and directed.
S & F 10 Watt 220 V AC Surface mounted Downlighter with ABS housing & PC Opal diffuser with integral electronic LED driver including taking down old unserviceable complete all as specified and directed
S & F replacement of 20 W LED Building security light fitting, drawn through including connecting up to from ceiling rose to the light fitting including taking down old unserviceable complete all as specified and directed
S & F 7W LED 3000 K Surface mounted spotlight in matt finish for premium aesthetics including taking down old unserviceable complete all as specified and directed
S & F in repairs LED Decorative, wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LED lamp B22 base including taking down old unserviceable complete all as specified and directed
S & F Post top lantern LED type 20watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant including taking down old unserviceable with driver complete all as specified and directed
S & F LED light fitting 9/10Watt Bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable complete all as specified and directed
S & F LED flood light 70 watt 230 VAC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down old unserviceable complete all as specified and directed
All as per item No 35.00 above but in 100 watt including taking down old unserviceable complete all as specified and directed
M & L 1.5 Sqmm wire 2 core PVC insulated sheathed flexible copper cable as per IS 694 complete all as specified and directed.
All as per item no 37.00 above but in 2.5 sqmm 2 Core complete all as specified and directed
S & F in replacement sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB 20 Amps 240 Volts including taking down old unserviceable complete all as specified and directed.
S & F Sheet metal enclosure with distribution board (DB) SPN, 8 way, double door, 200 Amps rated busbar 240 Volts fixed on wall and connecting including taking down old unserviceable of any ways/size/capacity complete all as specified and directed.
All as per item No 40.00 Above but in SPN, 4 way, distribution board double door complete all as specified and directed.
All as per item No 40.00 Above but in SPN 2 way distribution board single door complete all as specified and directed.
S & F Sheet metal enclosure with distribution board (DB) TPN 6 way double door 200 Amps rated busbar 415 Volts fixed on wall and connecting including taking down old unserviceable one complete all as specified and directed.
S & F in replacement MCB SP 6-32 Amps 240 Volt, 10 KA, "B" curve including taking down carefully old unserviceable MCB of any size/capacity complete all as specified and directed.
M & L MCB SPN 32 Amps 'C' series, 230 volts, 50 Hz suitable for fixing in MCB DB including taking down old unserviceable MCB complete all as specified and directed
S & F in replacement MCB TPN 63 Amps 415 Volt, 10 KA, "C" curve including taking down carefully old unserviceable MCB of any size/capacity complete all as specified and directed.
S & F in replacement MCB TPN 100 Amps 415 Volt, 10 KA, "C" curve including taking down carefully old unserviceable MCB of any size/capacity complete all as specified and directed.
M & L Painting of Metering Box (Inner & outer) of size (250 x 200 x 800) mm at site by removing the electrical connection of meter and refix at site after painting by synthetic enamel paint by spray painting including filling cavaties with filler, cleaning removing old paint scraping with emery paper, making all electrical connection and refixing meter by providing new bolts, nuts and washers complete all as specified and directed.
M & L Painting of Metering Box (Inner & outer) of size (660 x 625 x 150) mm at site by removing the electrical connection of meter and refix at site after painting by synthetic enamel paint by spray painting including filling cavaties with filler, cleaning removing old paint scraping with emery paper, making all electrical connection and refixing meter by providing new bolts, nuts and washers complete all as specified and directed.
Taking down ceiling fan 230 volts 1200/1400 mm sweep any make for undertaking rewinding/greasing /oiling, reassembling and testing after repairs/greasing etc and hanging to its original position and connecting complete all as specified and directed. [Note:- Material and Labour elements catered under Item No 51.00, 54.00, 56.00, 58.00, 59.00 are not included in this unit rate]
M & L re winding of ceiling fan motor 1200mm any make of fan with super enameled copper winding wire of existing size including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish , threading ,connections with twin core copper flexible wire of suitable size of length not more than one mtr with each fan including re fitting to its original position ets complete all as specified and directed.
Taking down exhaust fan heavy duty any make /size 300 to 450 mm sweep for undertaking rewinding/ greasing and reassembling after necessary repairs & refixing the same in its original position and connecting complete all as specified and directed . [Note:- Material and Labour elements catered under Item No 53.00, 55.00, 57.00 are not included in this unit rate]
M & L Winding of exhaust fan motor size 300 to 450 mm sweep with supper enameled copper winding wire of appropriate size including cutting of old winding, varnishing threading connections with 3 core PVC insulated & sheathed copper flexible wire of size 40/0.0076 mm of lenght not more than one mtr complete all as specified and directed .
Supply and replace capacitor AC 400/415 volts 2.5 mfd complete all as specified and directed.
All as per Srl item No 54.00 here in before but 4 mfd complete all as specified and directed.
Supply and replace ball bearing set of two for ceiling fan 1200mm sweep complete all as specified and directed.
Supply and replace ball bearing set of two for exhaust fan 300mm sweep complete all as specified and directed.
Supply and replace down rod of ceiling fan complete with split pin, hanging clamp and rubber reel, nuts, bolts, washers & lock pin (length of rod not less than 45 cm and not more than 60 cm) complete all as specified and directed.
Painting of ceiling fan at site with synthetic enamel paint by spray painting including filling cavaties with filler one coat after cleaning removing old paint scraping with emery paper, washing and applying one coat of red oxide paint etc and marking MES No on the ceiling fan complete all as specified and directed.
M & L for fixing machine/Installation details board made out of flex with iron frame inside the installations, made in flex of approximate size 3 ft X1 .5 ft with digital printing the equipment/installation description as given by the department complete all as specified and directed.
S & F Vinyl sheet indicator of size 75mmx 50 mm including printing/engraving the letter not exceeding 20mm height to identify the incoming and outgoing circuit of panel complete all as specified and directed.
M & L Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including required excavation and testing on including taking down old u/s materials complete all as specified and directed.
VITTAL P NAYAK
SIRI SALES AND SERVICES
KDR CONSTRUCTION
S M Shetty
PREETI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .