| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.1 LAccepted-AOC | ₹41.1 L | L1 | Accepted-AOC Please see the BOQ Summary details |
| 2 | L2₹43.6 L+₹2.5 L (6.06%)Rejected-AOC | ₹43.6 L+₹2.5 L (6.06%) | L2 | Rejected-AOC Please see the BOQ Summary details |
| 3 | L3₹46.9 L+₹5.9 L (14.3%)Rejected-AOC D NO 50 117 17 9 7 ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹46.9 L+₹5.9 L (14.3%) | L3 | Rejected-AOC Please see the BOQ Summary details |
| 4 | L4₹50.5 L+₹9.4 L (23.0%)Rejected-AOC | ₹50.5 L+₹9.4 L (23.0%) | L4 | Rejected-AOC Please see the BOQ Summary details |
Tender Value
₹47.7 L
EMD Value
₹95,400
Closing Date
2 Feb 2022, 3:00 pmClosed
Director of Lighthouse and Lightships
DEEP BHAVAN PORT RESIDENTIAL AREA SALIGRAMPURAM
Maintenance and Repairs to staff quarter buildings and compound wall at Dolphins Nose Lighthouse Cum DGPS Station
2022_DGLL_669762_1
MT-VSP-02002(02)/3/2021 - MAINT
Open Tender
Civil Works
Works
180 days
Post Box No. 134, Gandhigram Post Office, Yarada
Please refer Tender document
9 documents required · 9 mandatory
₹0
₹95,400
DEEP BHAVAN PORT RESIDENTIAL AREA SALIGRAMPURAM
4 Jul 2022
22 Jan 2022
3 Feb 2022
22 Jan 2022
2 Feb 2022
22 Jan 2022
22 Jan 2022 - 27 Jan 2022
27 Jan 2022
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared and all as directed including cost of all labour, tools & plants etc., and all other charges complete.
Dismantling/Demolishing of
a) Demolishing brick work or masonry walls manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge including the cost of all labours, necessary tools & plants and all other charges etc., complete.(for damaged latrine pedestals, Septic tank/Inspection chamber walls etc.)
b) Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge including the cost of all labours, necessary tools & plants and all other charges etc., complete.( for damaged sunshades,top perapet walls, precast shelves etc)
c) Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) including the cost of all labours, necessary tools & plants and all other charges etc., complete.( for damaged PCC for Septic tank/Inspection chamber bottom if required, support walls on top, pathways, plinth protection etc)
d) Dismantling tile work in floors and skirting laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm all as per direction of Engineer-in-charge including the cost of all labours, necessary tools & plants and all other charges etc., complete.(For damaged tiles flooring/skirting, decorative tiles on top slab etc.)
e) Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area 3 sq. metres and below all as per direction of Engineer-in-charge including the cost of all labours, necessary tools & plants and all other charges etc., complete.
a) Earth work in excavation including Ordinary rock by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, removal of snake huts lead upto 50 m and lift upto 1.5 m, and excavate without damaging of existing cables/Pipes as directed by Engineer-incharge.
b) Supplying and filling in plinth with clean river sand under floors, including watering, ramming, consolidating and dressing complete. including cost of all labour, tools & plants, etc., complete. (For replacement of sand at Children's park area etc.)
c) 150 mm thick filling with Stone aggregate 20 mm nominal size (single sized aggregate only) for around the transformer pedestal after levelling,compacting of the excavated before laying by earth rammer, stone aggregate filling as per required thickness etc. including supplying of required materials and consolidation etc. and as directed including cost of all labour, tools & plants, etc., complete. (for around the transformer)
a) Constructing of Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth for walls etc.,at all hights of Ist quality of approved as per I.G. 1977 in cement mortar 1:4 ( 1 cement : 4 coarse sand ) all as per drawing, all as per standard specifications and as directed including cost of all labour, materials, tools & plants, curing, scaffolding, etc. complete. ( for cable trench foundation, septic tank/Inspection Chamber replacement as per requirement at site, retaining perapet for Transformer etc.)
b) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : all as per drawing, all as per standard specifications and as directed including cost of all labour, materials, tools & plants, curing, scaffolding, etc. complete.(for closing ventilator for technical building etc.)
c) Providing and laying of half brick masonry with common burnt clay (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor Cement mortar 1:3 (1 cement :3 coarse sand) all as per drawing, all as per standard specifications and as directed including cost of all labour, materials, tools & plants, curing, scaffolding, etc. complete. (for surface drainage, platform partition etc.)
a) Providing and laying in position cement concrete of specified grade for - All works up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) all as per drawing, all as per standard specifications and as directed including cost of all labour, materials,machine mixing, tools & plants, compaction with needle & flat vibrator,curing, scaffolding, etc. complete.( for base of cable trench, support wall around the transformer and base of surface drainage where ever necessary)
b) Providing and laying in position cement concrete of specified grade for - All works up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) including adding of admixture and the dosage is 200ml per bag of cement all as per drawing, all as per standard specifications and as directed including cost of all labour, materials,machine mixing, tools & plants, compaction with needle & flat vibrator,curing, scaffolding, etc. complete.(base for RWCT, I.C. and septic tank as per requirement at site)
c) Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, including the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) including adding of admixture and the dosage is 200ml per bag of cement all as per drawing, all as per standard specifications and as directed including cost of all labour, materials, machine mixing, tools & plants, compaction with vibrator,curing, scaffolding, etc. complete.( for top slb damaged edges, sunshades etc.)
d) Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, including the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) including adding of admixture and the dosage is 200ml per bag of cement all as per drawing, all as per standard specifications and as directed including cost of all labour, materials, machine mixing, tools & plants, compaction with vibrator,curing, scaffolding, etc. complete.( for platforms & pre cast shelves)
e) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more all as per drawing, all as per standard specifications and as directed including cost of all labour, materials, tools & plants, scaffolding, etc. complete.
a) Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls & ceiling for staff quarters complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) including adding of waterproofing material and doasage as per manufaturer specifications all as per drawing, all as per standard specifications and as directed including cost of all labour, materials, mixing, tools & plants, curing, scaffolding, etc. complete. (for buildings)
b) Repair works to cracks in plastering / masonary / R.C.C. works/ lintels/ beams/ chajjas etc. cutting out cracks in 'V' section , cleaning out wetting, grouting with cement-sand slurry, 1:3( 1 Cement, 3 Sand) including mixing with water proofing compound as recommended by the manufacturer including supply of all materials, tools & plants, labours,curing, scaffoldings etc. complete as directed by the engineer in charge (for walls, compound wall and top perapet walls)
c) 15 mm cement plastering in CM (1:3) (1 cement: 3 fine sand) finished with a floating coat of neat cement of mix for existing drainages,coping for staff quarters & compound wall where ever necessary after including Dismantling old damaged plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead all as directed including supply of all materials, tools & plants, labours, curing, scaffoldings, etc. complete as directed by the engineer in charge.
d) 20mm thick Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating after Dismantling of old damaged/deteriorated cement plaster or skirting raking out joints where ever necessary and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead, hacking/pointing, cleaning, preparation of the surface etc. all as directed and as standard specifications and including cost of all materials, labour, tools & plants, curing for minimum 7 days from last pastering, necessary scaffolding for entire 30m height Lighthouse tower during the plastering etc complete. (for Cable trench walls, Septic tank outside portion and support wall near transformer).
e) Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry, after removal of water, cleaning the surface,hacking/pointing, apply plastering in C.M.(1:3) and as above and finally refill the water and retain 7 days for testing of leakage if occur leakages any, it should be rectified immediately all as directed including supply of all materials, tools & plants, labours, scaffolding, safety arrangements etc. complete as directed by the engineer in charge.(for inside treatment of RWCT, septic tank and Inspection chamber as per directed & requirement at site)
Applying paint two or more coats of approved brand (Asian paints Appcolite Hi-gloss enamel / Berger Luxol Hi-gloss enamel) , 1st quality, colour, shade on previously painted interior surfaces of staff quarters to give an even shade over a coat of putty & primer wherever necessary includinig cleaning the surface from all dirt, dust and other foreign matter, scrapping of old paint,necessary repairs to scratches, loose matter and sand papering at all heights all as directed and as per standard specifications including cost of all labour, materials, tools & plants, scaffolding, bosum chair, and safety measures, all other charges etc., complete.
a) Acrylic emulsion paint over a coat of water thinnable cement primer for interior surfaces of staff qtrs. at all heights walls & ceiling.(for Technical building and office & Recreation building)
b) Distempering with oil bound washable distemper two or more coats over and including water thinnable priming coat with cement primer for staff quarters
c) Finishing walls with Acrylic Smooth exterior paint of required shade Two or more coat applied @ 1.67 ltr/10 sqm on existing cement paint surface for old work for outside staff quarters and compound wall.
Applying two or more coats of Synthetic Enamel paint of approved brand (Asian paints Appcolite Hi-gloss enamel / Berger Luxol Hi-gloss enamel) , 1st quality, colour, shade on previously painted surfaces of allied buildings to give an even shade over a coat of primer wherever necessary includinig cleaning the surface from all dirt, dust and other foreign matter, scrapping, remove loose matter, apply wood putty and sand papering at all heights all as directed and as per standard specifications including cost of all labour, materials, tools & plants, scaffolding, bosum chair, and safety measures, all other charges etc., complete.
a) wood and wooden surfaces for allied buildings at all heights including a coat of primer where ever necessary
b) Metal surfaces for allied buildings, Childrens park and for top hand rail of Lighthouse tower at all heights including a coat of steel primer
a) Repairing & Polishing on wood work with ready made wax polish of approved brand and manufacture for Old work should give the good look on wooden furniture surfaces and as including fill the gaps with wood putty, scrapping, cleaning, polishing after repairing of wooden legs including nails & screws all as directed including cost of all materials, labour, tools & plants and all other charges etc. complete.
b) Replacement 12mm thick marine plywood sheets in existing wooden cot of good shape & size of approved 1st quality fixed in position and as directed with all required fitting & fixtures including cost of all materials, labour, tools & plants and all other charges etc. complete.(for damaged cable duct, cot, dining table, chairs, teapoi etc.)
c) Replacement with new Providing & Fixing decorative high pressure 1.5 mm thick laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality after removing of existing damaged/deteriorated laminated sheet for teapoi all as directed including cost of all materials, labour, tools & plants and all other charges etc. complete. (For dining table, dining chairs, teapoi etc.)
Wooden works for
a) Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge and as including supply of all labour, tools & plants and all other charges etc complete. (for damaged door/window /CB and the replacement of damaged wood can take from the wood work item for frames & shutters as per requirement at site )
b) Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) all as per standard specifications and as directed including cost of all labour, materials, tools & plants, etc. complete.(frames for doors, windows, flyproof shutters and CB. Approval should be taken with the submission wooden sample before start the work)(With Second class teak wood)
c) Providing and fixing of Second class teak wood including ISI marked anodized aluminium butt hinges with necessary screws for 25mm thick fly proof Door/window shutters with Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture (Make REMOPEST) with matching wood beading and all complete as per direction of Engineer-in-charge including the cost of all materials, labours, necessary screws tools & plants and all other charges etc., complete. (for 25mm thick fly proof door/Window shutters before start the work, Approval should be taken with the submission wooden sample)
d) Providing and fixing 35 mm thick ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. including ISI marked Stainless Steel butt hinges with necessary screws all as directed Including supply of all material,labours, tools & plants and all other charges etc., complete.
e) Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge. Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge SUB HEAD : 9.0 WOOD AND P.V.C. WORK 202 Code Description Unit Rate No. side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer's specifications and direction of Engineer-in-charge (for bath room door frame & shutter)
f) Providing and fixing in position (as per 1868/1982) Alluminum sliding window of two tracks with rectangular pipe 95x38.10x0.90 millimetre at weight 0.637 kg/mtr. with window frame bottom track section 92x31.75x1.30 mm at weight 10.70kg/mtr. Top and side track section 92x31.75x1.30mm at wight 0.933kg/mtr. The shutter should be of bearing bottom 40x18x1.25mm at weight 0.417kg/mtr. inter locking section 40x18x1.10mm at weight 0.469kg/mtr. and handle and top section 40x18x1.25 mm at weight 0.417kg/mtr. as per detailed drawing and as directed by Engineer incharge with all necessary Aluminium section fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted verticle section of shutter including 5 mm thick high performance single glaze unit (SUG)-glass aluminium mosquito net shutter with stainless steel jali with all required screws and nuts etc. complete. with colour anodising with box. including cost of all materials, labour, tools, scaffolding etc; complete.( 1.0x1.20m for Luggage room near entrance gate)
a) Replacement of damaged flyproof mesh by providing & fixing of new Fly proof stainless steel (Make REMOPEST) grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching 2nd class teak wood beading for existing fly proof shutters all fixed in position including removal of damaged flyproof mesh & replace as specified above without damaging the shutter all as directed and as standard specifications including the cost of all materials, labours, tools & plants and all other charges etc., complete (for existing fly proof doors/windows etc.)
b) Replacement PVC mesh for existing damaged chairs including the cost of all materials, labours, tools & plants and all other charges etc., complete
c) Renewing glass panes (make Saint Gobain/AIS/Pilkington) for doors & windows with 1st class teak wood beading & putty wherever necessary fixing Float glass panes of thickness 4 mm in position after removing broken/damaged glass panes, disposal of all debris as directed including cost of all materials, labour, tools & plants and all other charges etc. complete.
a) Replacement of damaged as per existing G.I/M.S squares, pipes, flats, arrows, chains, sheets, including beautificational items upto 40kgs of each 2No works for childrens park and entrance main gate all as directed including the cost of all materials, labour, fabrication, welding, rivetting, hoisting, apply primer etc. complete. ( for 2No complete works for children park playing items & main gate)
b) Repairing and raising of existing wicket gate including replacement of bolts, nuts, vouchers, hold fasts as per requirement at site for free movement all as directed including the cost of all materials, labour, fabrication, welding, rivetting, hoisting, apply primer etc. complete.
c) Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete. all as directed including the cost of all materials, labour, fabrication, welding, rivetting, hoisting, apply primer etc. complete.( for framing to Precast covers to RWCT)
d) Repairing of aluminium sliding windows including necessary clips, rollers, pins, screws, rubber gaskets, replacement of damaged items complete work for free movement all as directed including the cost of all materials, labour, fabrication, welding, rivetting, hoisting, etc. complete. (for IQ 1st floor)
e) Replacement with new Providing and fixing of corrugated asbestos cement sheets with MS L-hook, J-hook, screws, vouchers,drilling of holes, covering of holes will be filled by water proofing material for arresting leakage etc including removal of existing damaged sheets all as directed including the cost of all materials, labour, fabrication, rivetting, hoisting, etc. complete.(for AE Qtr.)
f) Replacement with new providing and fixing of 1.00 mm thick with zinc coating not less than 275 gm/m² corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.all as directed including the cost of all materials, labour, fabrication, welding, rivetting, hoisting, removal of damaged sheets etc. complete.(for luggage room near security room).
a) Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation on ordinary rock, levelling & dressing & finishing the top smooth all as directed including cost of all materials, labour, tools & plants and all other charges etc. complete (for existing staff qtrs. and LHT/IQ)
b) Repair to cracks upto 2.0m & patch plastering upto 3.0 sqm per existing 1No tree pedestal including replacemnt of soil around the tree and cleaning for complete job all as directed including cost of all materials, labour, tools & plants and all other charges etc. complete
c) Raking out joints of stone masonry/Renovation of putty for decorative tiles on roof surface to the required width and depth, with due care and precaution, by mechanical / manual means, including preparing and cleaning the surface for re-pointing/ refilling of joints with C.M.(1:3) mixed with 2% integral water proofing compound where ever necessary including disposal of rubbish to the dumping ground within 50 metre lead. all as directed including cost of all materials, labour, tools & plants and all other charges etc. complete ( for Rear side of LHT/IQ on existing stone pitching and Renovation of putty for decorative tiles on roof where ever necessary)
d) Cutting holes up to 15x15 cm in R.C.C./brick/stone masonry walls, floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. all as directed including cost of all materials, labour, tools & plants and all other charges etc. complete.
a) Replacement with new Providing and laying vitrified floor tiles of size 600x600 mm in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make (Johnson's/ Kajaria), in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. after removal of damaged existing flooring/skirting and as including hacking/pointing all as per standard specifications,including cost of all labour, materials, tools and plants etc. complete.(for Technical building)
b) Providing and laying Ceramic glazed anti skid floor tiles of size 400x400/300x300 mm where ever necessary for staff quarters toilet & steps work (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete after removal of existing damaged floors/skirting and all as per standard specifications, and including cost of all labour, materials, tools and plants etc. complete.(for bathroom/steps/existng floor tiles where ever necessary size as per existing floor)
c) Providing and fixing 1st quality ceramic glazed tiles for dado where ever necessary at bath rooms & kitchen walls conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade etc. complete after removal of existing damaged dado and as including hacking & cleaning the surface all as directed and as per standard specifications including cost of all labour, materials, tools and plants etc. complete.
d) Replacement with new Providing and laying of flat pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete after removel of damaged tiles, hacking/pointing, cleaning etc all as per standard specifications, and including cost of all labour, materials, tools and plants etc. complete
Replacement with new Providing & fixing of door/window/CB fittings & fixtures are instead of old damaged / deteriorated without damaging of existing wooden surfaces for
a) Providing and fixing ISI marked 125x75x4 mm aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
b) Providing and fixing ISI marked 100x63x4 mm aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
c) Providing and fixing ISI marked :75x63x4 mm aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
d) Replacement of Aluminium/SS 300mm long sliding door bolt Aldrop and the GEM Product id: 5116877-42722131798
e) Providing and fixing 125 mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
f) Providing and fixing 100 mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
g) Providing and fixing of 250x10 mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
h) Providing and fixing of 150x10 mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
i) Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
j) Providing and fixing of 2nd class standard 125mm door/Window wooden stopper with ISI marked 100x58x1.90 mm oxidised M.S. pressed butt hinges with necessary screws etc. complete. (for door/Windows and fly proof shutters)
WATER SUPPLY
a) Replacement with new Providing and fixing 25 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) : all as directed including supply of all materials, tools & plants, labours, scaffoldings, safety arrangements, removal of damaged existing etc. complete as directed by the engineer in charge.
b) Replacement with new Providing and fixing 25 mm nominal bore G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : all as directed including supply of all materials, tools & plants, labours, scaffoldings, safety arrangements, removal of damaged existing etc. complete as directed by the engineer in charge.
c) Replacement with new Providing and fixing 15 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) : all as directed including supply of all materials, tools & plants, labours, scaffoldings, safety arrangements, removal of damaged existing etc. complete as directed by the engineer in charge.
d) Replacement with new Providing and fixing 15 mm nominal bore G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : all as directed including supply of all materials, tools & plants, labours, scaffoldings, safety arrangements, removal of damaged/rusting of existing etc. complete as directed by the engineer in charge.
e) Replacement with new Providing and fixing 15 mm dia nominal bore G.I. pipes/nipples complete with G.I. fittings including trenching and refilling etc. and cutting & making good for walls wherever required : all as directed including supply of all materials, tools & plants, labours, scaffoldings, safety arrangements, removal of damaged/rusting of existing etc. complete as directed by the engineer in charge.
a) Replacement with new Providing and fixing 15 mm nominal dia Pipes Chlorinated Polyvinyl Chloride (CPVC) pipes (Make Ashirvad/Finolex) Internal work - Exposed on wall, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
b) Replacement with new Providing and fixing 40mm P.V.C. waste pipe Semi rigid for sink or wash basin including P.V.C. waste fittings complete.all as directed including supply of all materials, tools & plants, labours etc. complete as directed by the engineer in charge
c) Replacement of PVC water storage tank cover (Brand SINTEX) including supply of all materials, tools & plants, labours etc. complete as directed by the engineer in charge (at top of IQ)
Replacement of bathroom items are
a) Replacement with new Providing and fixing of S.C.I. gully or nahani grating 100 mm dia (or SS jali) after removing of old deteriotated/damaged SS jali all as directed including cost of all labour, materials, tools & plants etc., and all other charges complete.
b) Replacement with new Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete after removal of old mirror including cost of all labour, materials, tools & plants etc., and all other charges complete.
c) Replacement with new Providing and fixing White Vitreous China Wash basin size 550x400 mm (Make CERA/Perryware) with C.I. brackets, 15 mm dia CP Brass single hole basin mixer 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required after removal of old damaged/deteriorated wash basin of complete fittings & fixtures all as per standard specifications, and as directed including cost of all labour, materials, tools & plants etc., and all other charges complete.
d) Replacement with new Providing and fixing 610x510 mm bowl depth 200 mm Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink without drain board after removal of old deteriorated/damaged SS sink and make good finish after replace all as per standard specifications, and as directed including cost of all labour, materials, tools & plants etc., and all other charges complete.
e) Replacement with new Providing and fixing C.P.Brass soap Dish Holder after removing of old deteriotated/damaged soap dish holder all as directed including cost of all labour, materials, tools & plants etc., and all other charges complete.
f) Replacement with new Providing and fixing P.V.C. 10 litre capacity - White low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, (Make CERA/Hindware) with all fittings and fixtures complete where ever necessary all as directed including cost of all labour, materials, tools & plants etc., and all other charges complete.
g) Replacement with new Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, (Make Perryware /Hindware) including removal of existing damaged pan with flush tank, cutting and making good the walls and floors wherever required: where ever necessary all as directed including cost of all labour, materials, tools & plants etc., and all other charges complete.
h) Replacement with new Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality (Make CERA/jaquar) conforming to IS standards and weighing not less than 690 gms. including fixing in position after removing of old deteriotated/damaged bib cock all as directed including cost of all labour, materials, tools & plants etc., and all other charges complete.
i) Replacement with new Providing and fixing 15 mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make (Make CERA/jaquar) conforming to IS:8931 where ever necessary including fixing in position after removing of old deteriotated/damaged stop cock all as directed including cost of all labour, materials, tools & plants etc., and all other charges complete.
j) Replacement with new Providing and fixing 15 mm nominal bore C.P. brass angle cock of standard design and of approved make (Make CERA/jaquar) where ever necessary including fixing in position after removing of old deteriotated/damaged stop cock all as directed including cost of all labour, materials, tools & plants etc., and all other charges complete.
k) Replacement with new Providing and fixing of (C.P.Brass) Health Faucet (full set) ( Make CERA/Jaguar) with 1.2m Stainless Steel Braided Rubber Hose , for 15mm nominal bore where ever necessary including fixing in position after removing of old deteriotated/damaged health faucet all as directed including cost of all labour, materials, tools & plants and all other charges etc. complete.
l) Replacement with new Providing and fixing C.P. brass shower rose with 15 or 20 mm Stainless Steel 305 mm 12 Inch Shower Arm with Wall Flange Shower Head ( Make CERA/Jaguar) where ever necessary after removal of old shower rose including cost of all labour, materials, tools & plants etc., and all other charges complete.
m) Replacement with new Providing and fixing C.P.Brass towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms ( Make CERA/Jaguar) where ever necessary after removing of old deteriotated/damaged towel rail all as directed including cost of all labour, materials, tools & plants etc., and all other charges complete.
n) Replacement with new Providing and fixing C.P.Brass towel ring with concealed fittings arrangement of approved quality and colour, ( Make CERA/Hindware) where ever necessary after removing of old deteriotated/damaged towel ring including cost of all labour, materials, tools & plants etc., and all other charges complete.
o) Replacement with new Providing and fixing C.P.Brass push cock (button type) with concealed fittings arrangement of approved quality and colour, with good quality PVC connector ( Make CERA/Hindware) where ever necessary after removing of old deteriotated/damaged including cost of all labour, materials, tools & plants etc., and all other charges complete.( for urinals in Visitors toilet)
SANITORY
a) Providing and fixing on wall face 110 mm diameter 6Kg/cm2 unplasticised Rigid PVC soil/ waste pipes where ever necessary including fittings & fixtures (L-bend, bend,tee etc) of approved brand (Supreme/Finolex/Sudhakar) conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes of approved quality and fixing to wall with GI clamps, cutting walls and making holes, making good the same all as directed including cost of all labour, materials, tools & plants, removal of pipes etc. complete.
b) Replacement with new Providing and fixing PVC specials of 110mm dia PVC single tee/bend with door on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water/sanitory pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion where ever necessary all as directed including cost of all labour, materials, tools etc. complete.
c) Replacement with new Providing and fixing on wall face 75 mm diameter 6kg/cm2 unplasticised Rigid PVC waste water pipes where ever necessary including fittings & fixtures of approved brand (Supreme/Finolex/Sudhakar) conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes of approved quality and fixing to wall with GI clamps, cutting walls and making holes, making good the same where ever necessary all as directed including cost of all labour, materials, tools & plants, removal of pipes etc. complete.
d) Replacement with new Providing and fixing PVC specials of 75mm dia PVC single tee/bend with door on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water/sanitory pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion where ever necessary all as directed including cost of all labour, materials, tools etc. complete.
e) Replacement of PVC slotted vent cowl for 110mm diameter soil pipe where ever necessary all as directed including cost of all labour, materials, tools etc. complete.
a) Cleaning of septic tank with including soak pit, Inspection chamber, Surface drainage etc. at all heights including, bailing out water by pumping, removal of sludges and residues, disposing the septic tank residues in a pit and disposal of debris within a lead of 50 m, cleaning/removinig the obstruction in the manhole and sewer pipe lines removing the grass/bush at least 1m wide around the areas of cleaning of above all as directed including cost of all labour, tools & plants, applying bleaching/water treatment agencies in water tank and septic cleaninig agencies in septic tank, replacing the cover in septic tank, manhole and all other charges all as directed including cost of all labour, materials, tools etc. complete. etc. complete.
b) Clearing the any blockages in water pipe line of quarters/gardening pipes etc. including removal of rusting/soil/any wastage in the pipes, apply necessary chemicals during clearing and intimate to the staff before apply. All as directed including cost of all materials, labour, tools & plants etc.
a) Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design including excavation on ordinary rock soils where ever necessary and as directed including cost of all labour, tools & plants etc.
b) Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 all as directed including excavation on ordinary rock soils & back fliing where ever necessary and as directed including cost of all materials, labour, tools & plants and other charges etc. complete.
G CHINNAMNAIDU
ASR CONSTRUCTIONS
M/s-U. TECH SERVICE
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .