Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.5 L+₹1.9 L (7.77%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹27.2 L+₹2.6 L (10.4%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹27.3 L+₹2.7 L (10.8%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹27.5 L+₹2.9 L (11.7%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
23 Mar 2021, 6:00 pmClosed
GE I NAVY JAMNAGAR
INS NAVY VALSURA JAMNAGAR 361150
REPAIR AND MAINTENANCE OF DIESEL GENERATOR SETS FIRE FIGHTING SYSTEM AND LT UG CABLES UNDER GE I NAVY JAMNAGAR
2021_MES_428424_1
8497
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I NAVY JAMNAGAR
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹50,000
Yes
20 May 2021
5 Mar 2021
25 Mar 2021
5 Mar 2021
23 Mar 2021
18 Mar 2021
5 Mar 2021 - 17 Mar 2021
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of pipe line etc and getting out in soft/ loose soil complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L river sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable. Note: Thickness after punning shall be measured for payment.
Taking down old existing HT PCC Cable Cover complete all as specified.
Laying only HT PCC cable covers for protection of UG cable in trenches, cable cover obtained from Item Sl No. 5 here-in-above.
Supplying and laying unreinforced precast cement concrete cable covers,ISI Marked Class HV, Flat, Type - 1, of size 300 mm X 180 mm X 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and as directed by the Engineer - in - Charge.
Supplying, laying and commissioning of HT XLPE cables, insulated, screened, PVC bedded, galvanized steel strip armoured, earthed, electric power cable with Aluminium conductor, 11 KV grade, 3 Core, 95 Sq.mm cross sectional area laid in trenches / fixed on poles including taking down old cables complete all as specified and as directed. Note: Earth work,excavation,cable covers and sand cushioning shall be measured and paid separately.
Taking up old existing LT PCC cable cover complete.
Laying only LT PCC cable covers for protection of UG cable in trenches, cable cover obtained from Item Sl No. 9 here-in-above.
Supply and laying un-reinforced precast cement concrete cable cover, class LV, type 1, flat, size 250x150x40 mm for protection of underground cable in trenches complete all as directed. Make: Mehtab tiles / Ultra tiles / Sirex / Scorpio/ Sukhi tiles or any ISI marked tiles as approved by GE.
Supply and lay 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2, laid in trenches as cable protection with all fittings complete all as directed.
Material and Labour for heat shrinkable HT, 11 KV, outdoor type, cable straight through joint suitable for 11 KV, 3 Phase, AC, 50 Hz, 3 Core, 95/120 Sq.mm, XLPE Cable including jointing materials etc complete all as specified and as directed by EIC.
Material and labour for heat shrinkable HT, 11 KV, indoor type, cable end joint suitable for 11 KV, 3 Phase, AC, 50 Hz, 3 Core, 95/120 Sq.mm, XLPE Cable including jointing materials complete including taking down old end joints all as specified and as directed by EIC
Material and labour for heat shrinkable HT, 11 KV, outdoor type, cable end joint suitable for 11 KV, 3 Phase, AC, 50 Hz, 3 Core, 95/120 Sq.mm, XLPE Cable including jointing materials complete including taking down old end joints all as specified and as directed by EIC
Taking down unservicable calbe laid in any description and Supply, lay and testing new XLPE insulated, extruded, PVC outersheathed and innersheated galvanised steel, armoured heavy duty LT UG electric cable with aluminium conductor, 1100 Volts grade, conforming to IS: 7098 (Part I) 1988 cross-sectional area 300 Sqmm, 3.5 core and laid in trenches / pipe / ducts complete all as directed.
All as per item No. 16 here in above, but cross-sectional area 240 Sqmm, 3.5 core.
All as per item No. 16 here in above, but cross-sectional area 185 Sqmm, 3.5 core.
All as per item No. 16 here in above, but cross-sectional area 150 Sqmm, 3.5 core.
All as per item No. 16 here in above, but cross-sectional area 120 Sqmm, 3.5 core.
All as per item No. 16 here in above, but cross-sectional area 95 Sqmm, 3.5 core.
All as per item No. 16 here in above, but cross-sectional area 70 Sqmm, 3.5 core.
All as per item No. 16 here in above, but cross-sectional area 50 Sqmm, 3.5 core.
All as per item No. 16 here in above, but cross-sectional area 35 Sqmm, 3.5 core.
All as per item No. 16 here in above, but cross-sectional area 25 Sqmm, 3.5 core.
All as per item No. 16 here in above, but cross-sectional area 16 Sqmm, 4 core.
M&L straight through heat shrink joints PVC / XLPE insulated armoured heavy duty LT UG cables with aluminium conductor, cross-sectional area 16 Sqmm, 2/4 core including aluminium lugs / thimbles complete all as specified.
All as per item No. 27 here in above, but cross-sectional area 25 Sqmm to 35 Sqmm, 3.5 core.
All as per item No. 27 here in above, but cross-sectional area 50 Sqmm to 70 Sqmm, 3.5 core.
All as per item No. 27 here in above, but cross-sectional area 95 Sqmm to 120 Sqmm , 3.5 core.
All as per item No. 27 here in above, but cross-sectional area 150 Sqmm to 185 Sqmm, 3.5 core.
All as per item No. 27 here in above, but cross-sectional area 240 Sqmm to 300 Sqmm, 3.5 core.
Taking down rusted / worn out GI Pipe any dia form excavated trench and Supply and lay in trenches new GI Pipe 100 mm bore light grade (ISI Marked) with necessary fittings such as bend, tee, elbow etc., and testing on completion complete all as specified & directed..
All same as per item No. 33 here-in above but 80 mm bore of pipe -do-
All same as per item No. 33 here-in above but 50 mm bore of pipe -do-
M & L for PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in foundation filling mass concrete complete all as specified and directed
M&L for PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) in coping of pole complete
S&F in repair MCCB thermal magnetic protection unit rating 400 Amp, 4 pole, 36 kA type DPX3 in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified and as directed. Make:Legrand Cat No 4220 07 or equivalent in ABB/ Siemen/ L&T/ Havells.
S&F in repair MCCB thermal magnetic protection unit rating 320 Amp, 4 pole, 36 kA type DPX3 in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified and as directed. Make:Legrand Cat No 4220 06 or equivalent in ABB/ Siemen/ L&T/ Havells.
S&F in repair MCCB thermal magnetic protection unit rating 250 Amp, 4 pole, 36 kA type DPX3 in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified and as directed. Make:Legrand Cat No 4202 49 or equivalent in ABB/ Siemen/ L&T/ Havells.
S&F in repair MCCB thermal magnetic protection unit rating 160 Amp, 4 pole, 16 kA type DPX3 in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified and as directed. Make:Legrand Cat No 4202 17 or equivalent in ABB/ Siemen/ L&T/ Havells.
S&F in repair MCCB thermal magnetic protection unit rating 100 Amp, 4 pole, 16 kA type DPX3 in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified and as directed. Make:Legrand Cat No 4200 15 or equivalent in ABB/ Siemen/ L&T/ Havells.
S&F in repair MCCB thermal magnetic protection unit rating 125 Amp, 4 pole, 16 kA type DPX3 in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified and as directed. Make:Legrand Cat No 4200 16 or equivalent in ABB/ Siemen/ L&T/ Havells.
S&F in repair MCCB thermal magnetic protection unit rating 63 Amp, 4 pole, 16 kA type DPX3 in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified and as directed. Make:Legrand Cat No 4200 13 or equivalent in ABB/ Siemen/ L&T/ Havells. Note for item No. 38 to 44: Rate quoted deemed to included for taking down the existing MCCB from panel board and incoming/ outgoing cable and fix the new MCCB incoming/ outgoing cable connection of any size/ rating in position at panel board.
S&F in repair MCB TPN 32 Amp 415 volts, 50 Hz, AC, 10 kA with necessary lugs complete all as specified Make Legrand Cat No. 4086 80 or equivalent in ABB / Siemens/ Havells/ L&T
S&F in repair MCB TPN 63 Amp 415 volts, 50 Hz, AC, 10 kA with necessary lugs complete all as specified Make Legrand Cat No. 4086 83 or equivalent in ABB / Siemens/ Havells/ L&T
S&F in repair MCB SPN 32 Amp 415 volts, 50 Hz, AC, 10 kA with necessary lugs complete all as specified. Make: Legrand Cat No. 4086 09 to 4086 17 or equivalent in ABB / Siemens/ Havells/ L&T
S&F in repair MCB SPN 40 to 63 Amp 415 volts, 50 Hz, AC, 10 kA with necessary lugs complete all as specified Make Legrand Cat No. 408618 to 408620 or equivalent in ABB / Siemens/ Havells/ L&T
M&L for servicing of feeder pillar box, after dismantling the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified and as directed. Note: (i) Spare parts such as terminals, lugs, nut bolts, insulators etc will be measured and paid under respective item in the schedule, (ii) Labour for fixing charges of the spare parts deemed to be included in the rate quoted for the items.
Supply only aluminium lugs of any type / shape of capacity 400 Sqmm
Supply only aluminium lugs of any type / shape of capacity 300 Sqmm
Supply only aluminium lugs of any type / shape of capacity 240 Sqmm
Supply only aluminium lugs of any type / shape of capacity 150 Sqmm
Supply only aluminium lugs of any type / shape of capacity 120 Sqmm
Supply only aluminium lugs of any type / shape of capacity 95 Sqmm
Supply only aluminium lugs of any type / shape of capacity 70 Sqmm
Supply only aluminium lugs of any type / shape of capacity 50 Sqmm
Supply only aluminium lugs of any type / shape of capacity 35 Sqmm
Supply only aluminium lugs of any type / shape of capacity 25 Sqmm
Supply only aluminium lugs of any type / shape of capacity 16 Sqmm
Supply only GI Nuts, bolts, screws, washers of required sizes
S&F Extension link four set for DPX 63/ 125/ 160/ 185 Amp. Make: Legrand Cat Part No. 6250 06 or equivalent in Havells / Standard / IndoAsian
S&F Extension four link set for DPX 250/ 320 Amp. Make: Legrand Cat Part No. 6250 18 or equivalent in Havells / Standard / IndoAsian
S&F Extension four link set for DPX 400 / 630 Amp. Make: Legrand Cat Part No. 6250 08 or equivalent in Havells / Standard / IndoAsian
S&F Stainless Steel Double Compression Cable Glands, suitable for cable size 25 to 120 sqmm.
All as per item No 65 above but suitable for cable size 150 to 400 sqmm.
S&F in repairs junction box made from FRP sheet 2.00 mm thick readymade of size 400 x 300 x 200mm having 200A capacity including RYB and neutral with aluminium busbar with 4 way connector, fixed to pole/ Wall with MS clamp 25 x 5 mm and suitable size of nut, bolts and washers complete all as specified.
M&L for Mild steel angle cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint complete all as specified.
M&L for Reinforced concrete pipe 150 mm bore Class NP2 (ISI Marked ) alongwith collar laid to slope in trenches over PCC bed & jointed in cement mortar 1:3 and tested on completion including concrete bed in PCC 1:4:8 type D2 using 40 mm graded stone aggregrate to drain pipes including packing and haunching completely surrondings of the pipe after they are laid and tested complete all as specified and directed.(Note : (i) Earthwork for pipe measured & paid seperately. (ii) Quoted rate is deemed to be inclusive of concrete bed & haunching).
ambika electric co
M/S Badri Electicals
fakhrie apostrical
Jyoti Refrigeration
J J ENTERPRISE
JAYESH TRADING CORPORATION
JAMNAGAR ELECTRIC AND MACHINERY CO
M/s Jagdish Machinery Stores
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .