Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹42.4 L+₹3.9 L (10.3%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹42.9 L+₹4.5 L (11.7%)Rejected-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L3 | Rejected-AOC AOC rejected. | |
| 4 | L4₹46.1 L+₹7.7 L (20.0%)Rejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | L4 | Rejected-AOC AOC rejected. | |
| 5 | L5₹56.3 L+₹17.8 L (46.4%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L5 | Rejected-AOC AOC rejected. |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
18 Oct 2024, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair/ maint of Street lights and allied Works at Birpur and Ghunghora under AGE E/M - II of GE Dehradun.
2024_MES_675726_1
8844/A/E8
Open Tender
Civil Works
Item Rate
334 days
GE Dehradun
Class D cat b (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹99,800
Yes
30 Jan 2025
20 Sept 2024
21 Oct 2024
20 Sept 2024
18 Oct 2024
4 Oct 2024
Amount
Material and labour repair/ maintenance and attending electrical fault/complaints of street light cables/feeder OTM and MD accn at Birpur - Ghanghora area including identifing the faults and rectifying cable faults, cleaning and removing of carbon from circuits/ wire connection complete all as specified and directed.
Taking down carefully the existing unserviceable / defective street light fittings from Pole/ Bldg any type/ capacity & height for repairs / replacing the defective parts and refixing the same in the position after repairs and testing complete cable required for connection shall be deemed to be included in the quoted rates, size of cable shall be flat three core weather proof multistranded alumunium conductor cable, 2.5 mtr long complete all as specified and directed. (Note:- The repair work shall be carried out on complaint basis and shall be measured & paid only once through out the contract period after carrying out irrespective number of repairs and required spairs parts shall be measured and paid seperatly.)
Note for Serial item No 1 to 2 :- (for the repair and maintenance) (i) T & P including convence to reach door to door for attending the jobs will be provided by the contractor. (ii) Material will provided by department through maintenance cell and necessary salvage/ unused material deposit back to complaint cellincharge/ JE EM. (iii) The complaint slip will be collected from complaint cell incharge / EM by the contractor supervisor (iv) The area/ location of job will be all Md and OTM accn in ARO of AGE EM -I. (v) Scan coppy of EPF, ESIC will beprovided by the contractor at the time of bid at the time of bid submission otherwisebid will be rejected in tchnical bid. complaint not by contractor with in24 hours he will be liable for for penlalty / recovery of Rs 50/-per complaint. amount amount will be deducted from running payment / final bill of contractor
Supply and fixing in replacment of u/s driver suitable for 25 watt including LED light of LED street light fittings complete all as specified and directed. Make: Crompton SODRVES-36-600-25W/ Philips/Bajaj/Havells/Wipro.
Supply and fixing in replacment of u/s driver suitable for 45 watt including LED light of LED street light fittings complete all as specified and directed. Make: Crompton SODOL 65-700-40W/ Philips/Bajaj/Havells/Wipro.
Supply and fixing in replacment of u/s LED driver suitable for 75 watt including LED light of LED street light fittings complete all as specified and directed. Make: Crompton XO75CO70V107FNYIBO 75W/ Philips/Bajaj/Havells/Wipro.
Supply and fixing in replacment of u/s LED driver suitable for 100 watt including LED light of LED street light fittings complete all as specified and directed. Make: Crompton X100CO70V143FNYIBO 100W/ Philips/ wipro/ Bajaj/Havells.
Supply and fixing in replacement surge protection device 5KV 240 Volts suitable for LED 70watt street light fitting complete all as specified and directed. Make:- Crompton SRPS-HP-5KV-400/Philips/ Wipro
Supply and fixing in replacement surge protection device 10 KV 240 Volts suitable for LED 100 watt street light fitting complete all as specified and directed. Make:- Crompton SRPSO-10KV-440/Philips/ Wipro
Supply and fixing in replacement LED base plate efficacy > 110/120LPW, 10 KA SPD 240 Volts suitable for 25watt LED street light fitting complete all as specified and directed. Make:- Crompton /Philips/ Wipro
Supply and fixing in replacement LED base plate efficacy > 110/120LPW, 10 KA SPD 240 Volts suitable for 45watt LED street light fitting complete all as specified and directed. Make:- Crompton /Philips/ Wipro
Supply and fixing in replacement LED base plate efficacy > 110/120LPW, 10 KA SPD 240 Volts suitable for 70watt LED street light fitting complete all as specified and directed. Make:- Crompton /Philips/ Wipro
Supply and fixing in replacement LED base plate efficacy > 110/120LPW, 10 KA SPD 240 Volts suitable for 100watt LED street light fitting complete all as specified and directed. Make:- Crompton /Philips/ Wipro
Supply and fixing of 3 core 1.5 Sqmm copper conductor cable in existing pole incl making holes for cable entry and exist near to light fitting and junction box complete all as specified and directed.
Material and labour of 3 core 2.5 Sqmm copper conductor cable in existing pole incl making holes for cable entry and exist near to light fitting and junction box complete all as specified and directed.
Supply and fixing flood light fittings. Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing IP65 flood light with high power LED's as light sources, suitable for high lighting architectural features or retail spaces as 100 watt LED with lumen output 12500, system efficiency110/120 LPW,10KV SPD, CCT>5700K, PF>0.95, Glass cover complete all as specified and directed. Make: CROMPTON cat part No TFS-100-57-60D-HL2-GL-NSG/ Philips cat No. BVP120 LED70 CWNB FG S1 PSU GR/Havells cat part No. JETAFLAREFL70WLED757LTG including taking down old flood light fittings
Supply and fixing flood light fittings. Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing IP65 flood light with high power LED's as light sources, suitable for high lighting architectural features or retail spaces as 200 watt LED with lumen output 12500, system efficiency 110 lumen/watt 10KV SPD, CCT>5700K, PF>0.95, Glass cover complete all as specified and directed. Make:- CROMPTON cat part No TFS-507-200-57-60D-SL-GL-NSG/ Philips cat No. BVP120 LED70 CWNB FG S1 PSU GR/Havells cat part No. JETAFLAREFL70WLED757LTG including taking down old flood light fittings
Supply and fixing Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 100watt with efficiency 110/120 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed.. Make:- Crompton model No. TRP-411-100-57-HL2-GL-NSG/ Philips model No. BRP410LEDCW025FGSIPSUGR Havells model No. LHETAXU7PA6S025 and syska cat No- SSK-ST 25W including taking out old unserviceable street light.
Supply and fixing Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 75 watt with efficiency 110/120 lumen/watt10KV SPD at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed.. Make:- Crompton model No. TRP-409-70-57-SL-GL-NSG/ Philips model No. BRP410LEDCW072MRFGSIPSUGR Havells model No. LHETBXU7PA6J070 and syska cat No- SSK-ST 60W including taking out old unserviceable street light.
Supply and fixing Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 45/60watt with efficiency 110/120 lumen/watt 10KV SPDat system level, CCT>5700K, with average life class 50,000 burning hours, complete including taking out old unserviceable street light fitting all as specified and directed.. Make:- Crompton model No. TRP-409-45-57-SL-GL-NSG/ Havells model No. ENDURAPEARLNEOSL 40WLED757PASYTOPC /Philips Cat Part No BRP409LED CW036MRFGIPSUGRand syska SSK-ST-40W
Supply and fixing Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 35watt with efficiency 110 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete including taking out old unserviceable street light fitting all as specified and directed.. Make:- Crompton model No. LSTS-30-CDL-M/Havells model No. ENDURAPEARLNEOSL 40WLED757PASYTOPC /Philips Cat Part No BRP409LED CW036MRFGIPSUGRand syska SSK-ST-40W
Material and labour in replacement GI bracket made out of 40 mm GI pipe medium grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps 02 Nos not less than 50x6 mm MS flat duly painted, nuts, bolts and washer complete all as specified and directed. (Make TATA/JINDAL/Swastik).
Material and labour Street light brackets BEST pattern one way fixed on top of pole all as specified and directed by Engineer-In-Charge including taking up/down the existing unserviceable brackets and removing off the premises complete all as specified and directed.
Supply and fixing in replacement PVC (Tharmoplastic) street light junction box 250X200X100mm, heavy duty with locking arrangement, single phase and neutral two Nos copper busbar with hole for incoming and outgoing cable of size 6/10/16/25 sqmm 2 core, busbar of capacity 100 Amp PVC conduit up to the height of bottom level level of PVC Junction box from GL along with necessary MS clamp, nuts bolts and washers for fixing and one No. MCB Single Pole 240 Volts 6 Amps complete all as specified and directed.
Supply and fixing in replacement Pole mounted Junction Box as per sintex Cat No GS-JB-2520 ; 250X200X100mm for fixing cable with provision of four Nos copper busbar with hole for incoming and outgoing cable of size 6/10/16/25 sqmm 2/3.5/4 core, busbar of capacity 100 Amp mounted on epoxy insulator with MCB SP 6 Amp 'B' series including all bare conductor of cable duly insulated PVC heat shrinkable sleeve 1.1 KV heavy duty grade cp brass cable glands & lugs for incoming & outgoing connection all as directed. Make: Hensel/Schneider
Material and labour in replacement junction box made of glass fibre reinforced and transparent poly carbonate of size 126x228x111, KV PC 8104 with IP 65 protection including MCB SP, 6 Amps 1 No and suitable size clamps fixing for pole/in pcc foundation etc,including taking down the old one, complete all as specified and directed.
Material and labour in replacement sheet metal enclosures 240 volt, Single Door 2 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and out going complete all as specified and directed.
Material and labour MCB TPN 415Volt 10 KA 63 Amp 'B' series conforming to ISI marked complete all as specified & directed.
Material and labour MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed.
Material and labour MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed.
Material and labour in repair of power contactors 4 pole 80 Amps AC3 in control of timer etc complete incl taking existing and necessary connection complete all as specified and directed.
Material and labour of coil for contactor 40 Amps to 80 Amps as per existing sample complete incl taking out existing and necessary connections complete all as specified and directed.
Material and labour of timer astronomical digital type in repair incl taking out existing timer and necessary connection complete all as specified and directed.
Supply and fixing in replacement LED Solar street light fitting 20 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed. (Excavation & earth work shall be measured separately
Material and labour in replacement for street light timer suitable for out door operation, infrared sensor, as per seasonal variation of daylight complete with contactor, relay, MCB, sensor etc, auto - manual faclity duly complete wiring suitable for 15 KW capacity Single pole 230 Volt AC including GI clamping & fixing to pole with IP-65 a weather proof & out door type IK09 protection complete all as specified and directed. Make: Legrand/Simens/Schneider, Bajaj Cat No BJCP 10KW NS 1P/ABB
Material and labour for service cable 10 sq mm twin core weather proof aluminium multistranded conductor cable PVC sheathed PVC insulated complete all as specified and directed.
Description all as per item No 36 above but 6 Sqmm 2 core complete all as specified and directed.
Material and labour in replacement of GI tubing medium grade, complete with all fittings for installation of post top Lantern fitting of 50 mm bore complete all as specified and directed.
Material and labour in replacement of GI tubing medium grade, complete with all fittings for installation of post top Lantern fitting of 40 mm bore complete all as specified and directed.
Material and labour LED bollard type fitting 20 Watt cpacity 650 mm height, LED bollard AFlare fitted with low glare diffuser with IP 65 protection, complete with necessary pcc foundation including taking down existing old pattern unserviceable light fitting all as specified and directed. Make Crompton Cat Part No.LBSL 1-10-CDL or equivalent in Havells/ Bajaj/Eveready.
Material and labour in relacement LED decorative post top lantern for Garden light 40 watt IP 65 protection resistance to impact and corrosion glare, free and better uniformity milky version as per CG cat part No LPTO40CDL/ Bajaj model No. BGCTW4LEDWW including taking down old unserviceable post of lantern.
Material and labour in replacement laying, jointing and testing of underground XLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 Core laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed.
Description all as per Item No 42 above but 10 Sqmm 2 Core complete all as specified and directed.
Description all as per Item No 42 above but 16 Sq mm, 4 core complete all as specified and directed.
Description all as per Item No 42 above but 16 Sq mm, 2 core complete all as specified and directed.
Description all as per Item No 42 above but 25 Sq mm, 4 core complete all as specified and directed.
Description all as per Item No 42 above but 35 Sq mm, 4 core complete all as specified and directed.
Description all as per Item No 42 above but 50 Sq mm, 4 core complete all as specified and directed.
Material and labour for Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable, foundation of pole and getting out in any type soil complete all as specified and directed.
Material and labour for Returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Material and labour for Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
Material and labour for laying well burnt brick, sub class 'B' old size in trenches, as protection of under ground cable complete all as specified and directed.
Material and labour laying galvanised steel tubing 50 mm bore light grade laid in trenches or fixed to poles/walls etc for cable protection complete all as specified and directed.
Material and labour for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc complete all as specified and directed.
Material and labour for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) for coping of pole etc including necessary Steel form work and finishing exposed faces of concrete smooth and even using extra cement complete all as specified and directed.
Attending earth of LT/HT steel tubler/cement concret pole 9/11 mtr long cleaning of bird nest/debris /loose hanging wire /and securing with binding wire all as directed by Engr-in-charge
Material and labour Trimming/cutting of tree branches to provide proper clerance around existing HT over heah lines with clearance of 3mtr on all as per technical requirement including removing of cutted trees branches from site and depositing one place for burning/removing and directed by Engr-in-incharge.
Material and labour for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc. size of cutting 100mm wide and 200mm deep and removing the excavated materials and disposal at 50 metre distance and making good the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as specified and directed.
Material and labour , transporting, errecting and fixing in replacement Steel tubular swaged poles type 410 SP-31, 9.00 metre long , complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified including painting with two coats of synthetic enamalled paint over one coat of red oxide primer and 06 Nos bands/ straps with yellow and black colour ( 30 cm wide each)epoxy heat resistant paint at a distance 30 cm from plinth block and numbering of poles with black synthetic enamel paint in 2.5 cm height including tarring/Bituminous paint one coat on steel surface embedded in concrete foundation complete all as specified and shown on drawings and directed.
Material and labour in replacement cross arm, bracing supports, clamps and back plates fabricated from structural steel section, such as channel, ISMC, angle iron , flat iron nut, bolts & washers welding, cutting drilling hole for insulator bolts clamps in any shape size & two coats of aluminum paint over one coat of red oxide zinc chromate primer all as directed by Engr-in-Charge. Make: Jindal/TATA/Sail
Material and labour in replacement aluminium conductor steel reinforced (ACSR) conductors for LT OH line binding with copper binding wire/alumium tape line connector of suitable size with insulator/stretching of ACSR conductor complete all as specified and directed including taking out old ACSR conductor. Make: Indian Aluminium Co./Bharat conductor/Aluminium ind.
Material and labour in replacement galvanised steel wire 3.15 or 4mm dia , cradle guards, hexagonal/rectangular fabricated of galvanised steel wire 3.15mm dia including binding wire aluminium complete cradle guard complete all as specified and directed.
Material and labour Pin type insulator porcelain,vitereous white brown or green of size 100mm height & 65mm dia including one galvanised mild steel spindle, two galvanised iron washer, and one galvanised iron nut, 100mm, high and 65 mm dia, working pressure 1100 volts including taking down old one complete all as specified and directed. Make Southern insulator/BHEL/Ws Insulator/Jayshree
Material and labour shakle type insulator, porcelain, vitreous, white, brown, or green insulator including galvanised mild steel straps, washer, insulator bolts, washers, nut, LT, 1100 volt grade, height 75mm, max dia 90mm, section of strap 31x3mm, dia of bolt 12 mm including taking down old unserviceable insulator.Make Southern insulator/BHEL/Ws insulator/Jayshree
Material and labour in replacement for Stay assembly complete with accessories as shown in electrical plate No. 1 of 16 mm dia complete all as specified and directed. (for LT poles) NOTES :- loop type insulator,stay clamps,excavation and concrete work shall be measured and paid separately.
Material and labour in replacement loop type insulator vitreous procelain, white , brown or green, large size with overall dimensions 65 x 90mm, clearence of hole 16mm etc complete all as specified and directed.
Material and labour for galvanised stay strand, 7/3.15 mm complete all as specified and directed.
Material and labour for painting of poles 11 Mtr long with one coat of aluminium paint complete including fittings such as brackets etc. and black&white synthetic enamel paint on alternative strips upto height of 1.5mtr from copping of the pole including numbering the pole with 8cm letter with back paint having back ground of yellow painted circle of 10cm dia all as directed by Engineer-in-Charge
Description all as per item No 69 above but pole 9 Mtr long complete all as specified and directed.
Disconnecting existing LT OH/UG cables over heating burnt/ defective armoured cable terminal at existing panel/ switch board/feeder pillar box etc, cutting out over heated / burnt / unserviceable portion of cable, stretching / opening cable to suitable required length from available rings etc. fixing and connecting the cable in position properly by providing suitable new aluminium lugs and suitable GI nuts, bolts & washers etc. all as directed by the Engineer-in-Charge for the following sizes of cable :-
10 Sqmm to 16 Sqmm cable of any core complete all as specified and directed.
5 Sqmm to 120 Sqmm cable of any core complete all as specified and directed.
150 Sqmm to 240 Sqmm cable of any core complete all as specified and directed. (NOTE : Excavation and earth work for stretching the cable / increasing and obtaining necessary length from the rings etc. for making joints shall be measured and paid for separately under appropriate item of Schedule `A' )
Material and labour in replacement of u/s MCCB 500 Amps 50 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu complete all as specified and directed.
Material and labour in replacement of u/s MCCB 400 Amps 35 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu complete all as specified and directed.
Material and labour in replacement of u/s MCCB 250 Amps 35 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu complete all as specified and directed.
Material and labour in replacement of u/s MCCB 200 Amps 35 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu complete all as specified and directed.
Material and labour in replacement of u/s MCCB 160 Amps 25 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu complete all as specified and directed.
Material and labour for Alumn lugs 300 sqmm complete all as specified and directed.
Material and labour for Alumn lugs 120 sqmm complete all as specified and directed.
Material and labour for Alumn lugs 95 sqmm complete all as specified and directed.
Material and labour for Alumn lugs 50 sqmm complete all as specified and directed.
Material and labour for Alumn lugs 35 sqmm complete all as specified and directed.
Material and labour for Alumn lugs 25 sqmm complete all as specified and directed.
Material and labour for Alumn lugs 16 sqmm complete all as specified and directed.
Material and labour for Alumn lugs 10 sqmm complete all as specified and directed.
Material and labour for servicing of DG set of 62.5 KVA to 75 KVA 3 phase 50 HZ, Make : Cuminns/ Kirloskar/ Greaves. by cleaning, servicing, oiling and greasing of moving parts,checking the serviceability of self starter, alternator, AVR for proper voltage out put,Batteries voltage & electrolyte be checked & added upto top level, functunability of safety devices, all nut - bolts of Engine and alternator,proper tension of fan belts, check coolant level and if necessary top up.. Ensuring leak proof of all type hose for water , pipe line of fuel and lub oil. Checking of air cleaner element & clean it with dry compressed air (60 psi pressure.). Material and labour for replacement of Air filter elements set, cleaning of oil bath type filters and replacement of oilof oil bath filter, lubricating oil filters element complete set , Fuel filters element, By pass filter, Corrosion resistor plate, fan belts and labour for replacement of lubricating oil , complete as specified and directed.
NOTES: (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The cost of servicing of DG set are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, studs etc and parts mentioned in the item above.. (i) Make of DG set be one of the make mentioned in the item. (iii) Spare parts to be replaced shall be suitable for the same make and model of engine as installed at site and serviced. (iv) Cost of lubricating oil shall be measured and paid separately. (v) Cost Spare parts to be replaced shall be measured and paid separately under item No.2 here in after.
Taking out under mentioned unserviceable parts from the 62.5 KVA DG sets and supply and fixing of following new parts :-
Water hose pipe set with clamp for 62.5 KVA of DG set.
Lubricating oil pipe set with coupling for 62.5 KVA capacity of DG set.
Fuel oil pipe set with coupling for 62.5 KVA capacity of DG set.
Shut down valve suitable for 62. 5KVA of DG sets as per existing shape and size.
V Belt. make KCL/CIL
Oil filter
Deisel filter
Air filter
Coolent
Pump calibration
Servicing and overhauling of alternator
Supply and fixing in replacement the following spares/parts/ components of AMF Panels .
Power Contactor, LCIF 3 pole, coil voltage 415 / 440 Volts, 50 Hz with having current rating (AC3) of 100 Amps at 415 volts as per requirement .
Digital VMR
Batter charger 12 volts
Disply cover
LLOP sender
Stop solonoid
Pla relay 24 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -24D of pla make or equivalent of Eagle man.
Bimetal overload relay type MNX with relay range 24 – 40 Amps suitable for 3 phase 415 volts, AC supply (Make : L&T cat No. SS94145OOFO or equivalent of BCH )
Electronic DC timer suitable for 12/24 Volts DC supply, for 0-60 seconds. (on delay). (Make : L&T / PIC / Aditya Electronic)
Under voltage relay suitable for 3 phase 415 volts, AC supply (Make : PIC / Aditya Electronic )
Engine starting relay with sequence timer & Master timer suitable for 12 / 24 Volts DC supply. (Make : PIC / Aditya Electronic)
Indicating lamps neon type with holder for 12 / 24 volts DC supply (RYB) (Make : L&T/BCH or equivalent make as approved by the GE )
Electronic timer, suitable of 240 / 415 Volts, 50 Hz, AC supply, for 0-180 seconds (ON delay). (Make : L&T / PIC / Aditya Electronic)
Disconnecting, and taking out carefully old unserviceable AVR unit and supply , fixing, connecting and testing AVR unit suitable for DG set of 62.5 KVA capacity.and testing for regulated voltage of 415 volts complete all as specified and directed. Make Kirloskar/National/Universal
Supply - filling and toping up lubrication oil SAE-40 ( 20 W- 40 grade) of Make SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL/ CASTROL) as approved by GE.
Disconnecting and taking out the radiator of 63.5 KVA 3 phase capacity of DG set 50 HZ, Make ; Kirloskar and carrying out to work shop, strip opening completer radiator assembly, cleaning of tubes with using de-scaling solution, including soldering / gas welding of leakage of tubes. Cutting the rusted portion of in let or out let tubes including gas welding of new MS water tubes assembling the complete radiator including replacement of gasket, nut bolts, and testing for making it leak proof including oiling/servicing of water cooling assembly, replacing unserviceable parts, re-assembling and fixing the same in position and testing the system complete all as specified and directed by Engineer-in-Charge.
(NOTE :- (i) Repairs/servicing/reassembling and testing of water cooling assembly shall be carried out on actual load. (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, screws/gaskets/ packing etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro upto Work shop/service centre.)
Disconnecting and taking down old unserviceable self starter, 12 Volt DC and dismantling complete for repair, servicing, cleaning, varnishing, oiling, reassembling & testing including replacement of the Following parts :- (a) Armature – 01 No (b) Solenoid switch – 01 No. (c) Field coils – 01 No. (d) Commutator – 01 No. (e) Carbon brush – 02 Nos. (f) Bendex assembly – 01 No (g)Tension sleeve=01no (h) gear assembly-01 no
Material and labour for Cleaning of MS fuel tank of DG sets of various capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 metre and cleaning the tank with kerosene oil , replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed.
Dismantling and taking out old unserviceable Dynamo assembly of 62.5 KVA capacity of DG set for repair and replacement of defective parts like as Carbon brush, Bearing No. 6302 and rewinding to armature with suitable gauge of copper wire, sleeve, glass paper and Varnish, soldering to commutator assembly, reassembling & fixing the same in position and testing the dynamo assembly all as specified and directed by Engineer-in-Charge.
Supply & fixing of lead acid battery 12 Volts, 180 AH including 02 duly initial charging of the battery and fixing to its position complete all as specified and directed.
Disconnecting and taking out defective battery lead and supplying, fixing, connecting and testing battery lead (Heavy duty) PVC insulated with multi strand copper conductor single core of size 25 Sqmm for 2 metre length including one side fixed with brass/ copper eye hole lugs clamp and other side fixed with brass battery terminal of heavy duty complete all as specified and directed.
Material and labour PVC line spacers to LT over head line poly proplan compositer phase separater moulded bolted type suitable fo 5 line complete all as specified and directed.
Material and labour PVC line spacers to LT over head line poly proplan compositer phase separater moulded bolted type suitable for 4 line complete all as specified and directed.
Material and labour t PVC line spacers to LT over head line poly proplan compositer phase separater moulded bolted type suitable for 3 line complete all as specified and directed.
Material and labour PVC line spacers to LT over head line poly proplan compositer phase separater moulded bolted type suitable for 2 line complete all as specified and directed.
Material and labour for earthing complete with galvanised steel strip earth plate electrode 60x60cmx6.3mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised from strip of 32x6mm earth lead by means of bolts, nuts, check nuts and wathers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point/transformer/panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering complete.
Note: (i) If the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of galvanised strip 32x6mm earth lead and 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering upto 7.5 mtr is included in the rate quoted for this item
Description all as per item No 100 above but earth lead GI wire 4.00 mm. dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other ends of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm. bore and water pipe 20 mm. bore GI light grade with funnel and wire mesh, complete all as shown in elect plate No. 5 of SSR part I of 1991.
Material and labour and installation in replacement after dismantling of old US feeder piller, testing and comissioning of out door type Feeder Pillar box weather vermin proof factory made, front & back openable double door type with locking arrangement (including provn of 65 mm Godrej (Navtal) lock with 2 keys), fabricated out of 3.15mm thick CRCA sheet and 2mm thick inner enclouser CRCA sheet duly as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size complete with IP-54 protection having 433 volts, 3 phase, for 800 Amps rating 4 Nos, including all connections with copper strips, duly drilled holes for connections, RYB insulated with different colour code complete heat shrink insulated enclosed openable front & rear copper bus bar of Panel board shall be provided with danger notice plate with skull & bone sign, effectively PVC gasketed and sealed, glands to be provided at cable entries, including angle iron 50x50x6mm, 90 cm long with base and grouted in PCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) complete all as specified and directed and comprising of as under :- (Note:-The cost of the PCC plateform deemed to be included in the qouted rates of above said item).
Incoming :-(a) Air circuit breaker 415 Volt AC, 50 Hz, 630 Amp four pole breaking capcity 50 KA, manual drawout type, Microprocessor based. Make - c&S, Siemens Cat No 3WT80 - 01 No (b) Digital 3 lines LCD display panel mounted multifunction energy meter 96x96mm flush mounted accuracy class 1.0 complete with suitable size of CTs and copper control wiring Make- HPL Cat Part No - EM - VIPF or equivalent in AE - 01 No (c) Phase indicating lamp - 01 Set of three Out going :-(a) MCCB 400 Amp FP breaking capcity 35 KA 415 Volt AC, 50 Hz, with thermal Setting 70 to 100% - 01 No (b) MCCB 415 Volt AC, 50 Hz, 250 Amp TP breaking capcity 35 KA with thermal Setting 70 to 100% - 02 No (c) MCCB 415 Volt AC, 50 Hz, 200 Amp FP breaking capcity 35 KAwith thermal Setting 70 to 100% - 01 No (d) MCCB 415 Volt AC, 50 Hz, 100 Amp FP breaking capcity 25 KA with thermal Setting 70 to 100% - 02 Nos Note - Make of MCCB :- C&S/Schneider /L&T/Siemen/Legrand/ABB
Material and labour and installation in replacement after dismantling of old US feeder piller,n, testing and comissioning of outdoor type Feeder Pillar box factory made, front & back openable double door type with locking arrangement (including provn of 65 mm Godrej (Navtal) lock with 2 keys), of size not less than150cm x 90cm x 75cm, fabricated out of 3.15mm structure and 2mm enclouser CRCA sheet duly as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size complete with IP-54 protection having 433 volts, 3 phase, insulated bus bar for 400 Amps rating 4Nos, including all connections with aluminium strips, Pillar board shall be provided with danger notice plate with skull & bone sign, effectively PVC gasketed and sealed, glands to be provided at cable entries, including MS channel frame of ISMC 75 at the base of panel only for grouting purpose and grouted in PCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) complete all as specified and directed and comprising of as under :-
Incoming :-(a) MCCB 415 Volt AC, 50 Hz, 400 Amp four pole breaking capcity 50 KA, Microprocessor based. Make :- Siemens/L&T/Standard/Havells/BCH - 01 No (b) Digital 3 lines LCD display panel mounted multifunction energy meter 96x96mm flush mounted accuracy class 1.0 complete with suitable size of CTs and copper control wiring Make- HPL Cat Part No - EM - VIPF or equivalent in AE - 01 No (c) Phase indicating lamp - 01 Set of three Out going :-(a) MCCB 415 Volt AC, 50 Hz, 250 Amp TP breaking capcity 35 KA, thermal setting 70% - 100% - 01 No (b) MCCB 415 Volt AC, 50 Hz, 200 Amp TP breaking capcity 35 KA, thermal setting 70% - 100% - 02 No (c) MCCB 415 Volt AC, 50 Hz, 100 Amp TP breaking capcity 25 KA, thermal setting 705 - 100% - 02 Nos (d) MCCB 415 Volt AC, 50 Hz, 63 Amp TP breaking capcity 25 KA, thermal setting 705 - 100% - 02 Nos Note - Make of MCCB - L&T/Siemen/Legrand/Havells/Standard
Material and labour and installation in replacement after dismantling of old US bus bar, factory fabricated bus bar chamber out door pedestal type made out of 2.0 mm thick CRCA sheet of size 750x500x400 mm duly painted with powder coating, simens grey/RAL fitted with four Nos aluminium bus bar of capacity 400 Amps duly mounted epoxy insulator , Cable connections of incoming and outgoing cables duly insulated PVC heat shrinkable sleeve 1.1 KV grade including one No MCCB, 200 Amps, 4 pole, 16 KA, with adjustable thermal setting Ics=100% Icu, including glands c/p lugs etc including 50x50x6mm angle iron frame 450mm height above ground level and 450mm below ground level, angle iron frame shall be embeded in PCC (1:2:4) type B 1 block of size 200x200x200mm complete all as specified and directed including taking out old unserviceable bus bar chamber.
NOTE:- Amount of credit of Rs. 315810.10 for retrieved materials is mentioned in Schedule of Credit Page No 33 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Friends fire Engineers (BID ID -3143452)
PARADISE INFRA POWER COMPANY (BID ID -3133984)
M/s Kamal Traders (BID ID -3136730)
JS CONSTRUCTION COMPANY (BID ID -3143302)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .