| 1 | Electro Hydraulic Tyre killer | Supply, Installation, Testing Commissioning of Unidirectional Crash rated Electro Hydraulic Tyre killer of 7.00 Mtr length consisting of two section (3.5 Mtr + 3.5 Mtr) suitable to work on Three / single phase 400/230 volts +/- 5% , 50 Hz AC supply consisting of Tyre killer operating on hydraulic power system, PLC based, Stop/GO traffic light, single control panel for controlling two section, Accumulator system for Hydraulic operation in case of power failure including control switching operation in remote location (within 160 Mtr), logic circuit ,earthing connection, civil foundation including excavation of exisitng PQC & Bituminous road and making good with proper slope after installation of tyre killers including provision of horizontal type sump pump of suitable rating to drain accumulated water complete as required.Also supplying and laying of suitable size GI pipes(Minimum 40mm dia) for all type of cable protection, control cables (for internal system and for control upto remote location point), hydraulic system etc as required for complete functioning of tyre killers as per enclosed technical specifications (Crash rating test certificate from accredited authority shall be submitted by bidder). | 1 | Set | ELEC@VAJM | 180 |
| 2 | Electro Mechanical Boom Barrier | Supply, Installation, Testing Commissioning of Automatic Road Traffic Electro Mechanical Boom Barrier 3.5 Meter to 4 metre length of Two section suitable for 7.0 Mtr road to work on Three / single phase 400/230 volts +/- 5%, 50 Hz AC supply consisting of Boom Barrier Automatic, PLC based, control panel, including individual switching operation in local and remote location (within 30 Mtr) of two section logic circuit, earthing connection , civil foundation including excavation of exisitng PQC & Bituminous road (minimum 200mm depth) and making good after installation etc complete as required and supplying and laying of GI pipes and control cables (upto 30 Mtr) etc as required for complete as per enclosed technical specifications. | 4 | Set | ELEC@VAJM | 180 |
| 3 | Electro Hydraulic Bollard | Supply, testing & commissioning of K4 crash rated Electro Hydraulic Bollard system comprising of 07 (seven) numberof SS Bollards suitable to work on Three/Single phase 400/230 volt, 50 Hz AC supply consisting of hydraulic power unit, PLC based, logic circuit, control panel, Accumulator system for Hydraulic operation in case of power failure including switching operation in local and remote location (within 30 Mtr) complete as required including all major/minor civil & mechanical works, etc. comprising of following items and features as per enclosed technical specifications. Job includes making a parallel trench of suitable width (minimum 2ft) of RCC/ brickwork with plaster etc. with heavy grill iron cover in front of bollard line which is deeper than bollard line. This trench will be used for running of pressure pipe, draining the water from bollard system and maintenance purpose | 3 | Set | ELEC@VAJM | 180 |
| 4 | | Supply of following sizes of XLPE insulated, PVC sheathed, Aluminium Conductor, Armoured Power Cable, 1.1 KV grade conforming to IS 7098 (Part-I) 1988 with upto date amendments, complete as required.
4 Core x 16 Sq. mm | 542 | Meter | ELEC@VAJM | 180 |
| 5 | | Supply of following sizes of XLPE insulated, PVC sheathed, Aluminium Conductor, Armoured Power Cable, 1.1 KV grade conforming to IS 7098 (Part-I) 1988 with upto date amendments, complete as required.
3.5 Core x 25 Sq. mm | 658 | Meter | ELEC@VAJM | 180 |
| 6 | | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
4 Core x 16 Sq. mm (28mm) | 14 | Set | ELEC@VAJM | 180 |
| 7 | | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3.5 Core x 25 Sq. mm (28mm) | 2 | Set | ELEC@VAJM | 180 |
| 8 | | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 11 KV grade of following size direct in ground including excavation sand cushioning, protective covering and refilling the trench etc. as required,but excluding sand cushioning, protective covering.
Upto 35 Sq.mm | 800 | Meter | ELEC@VAJM | 180 |
| 9 | | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm | 1,100 | Meter | ELEC@VAJM | 180 |
| 10 | Cable laying In existing open duct | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm | 100 | Meter | ELEC@VAJM | 180 |