Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC 3 NO GANGADHAR KABIRAI LANE KHAGRA MURSHIDABAD | MURSHIDABAD | MURSHIDABAD | WEST BENGAL | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹42.4 L+₹1.9 L (4.62%)Rejected-Finance VILL HATIBAGAN P O P S JIAGNAJ MURSHIDABAD W B | JIAGNAJ | MURSHIDABAD | WEST BENGAL | 742123 | L2 | Rejected-Finance L2 | |
| 3 | L3₹44.1 L+₹3.6 L (8.93%)Rejected-Finance 131 NILMONI BHATTACHARJEE LANE KADAL BERHAMPORE MURSHIDABAD W B PIN 742102 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742102 | L3 | Rejected-Finance L3 | |
| 4 | L4₹46.5 L+₹6.0 L (14.9%)Rejected-Finance 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | L4 | Rejected-Finance L4 | |
| 5 | L5₹47.8 L+₹7.3 L (18.1%)Rejected-Finance 149 5 A PILKHANA ROAD BERHAMPORE DIST MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
20 Dec 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE PWD CEC
184, C.R.Das Road, Berhampore, Murshidabad, PIN-742101
Renovation and augmentation of establishment for 24 beded Hybrid Critical Care unit (8 CCU and 16 HDU beds) at MCH/DH/SDH/SSH level ----- Internal EI Work incl. SITC of DG, UPS. at Kandi S D Hospital Murshidabad.
2021_WBPWD_353325_1
WBPWD/CEC/eNIQ/19/Q/2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
KANDI S D HOSPITAL
Please refer Tender documents.
4 documents required · 4 mandatory
₹40,000
VIRTUAL WEBPLATFORM
7 Jan 2022
29 Nov 2021
22 Dec 2021
29 Nov 2021
20 Dec 2021
6 Dec 2021
4 Dec 2021
120 days
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed. avg run 10 mtr
avg run 8 mtr
avg run 6 mtr
on board plug
Supply & Fixing 240 V, 2 nos. 6A & 2 nos. 20A Modular type plug socket with 2 nos. 6A & 2 nos. 20A Modular type switch (Brand approved by EIC), without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2x6A, plug socket with separate2x 6 A Modular type switch (Brand approved by EIC) on G I Modular switch board embedded in wall incl. S & F 6 M Modular switch board with top cover plate and making necessary connections as required As per GS.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Supply & Fixing 240 V, 2 Nos. 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 2 Nos. 16A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Supplying and fixing 8 way upto 160A double door Vertical TPN MCB Distribution board for100A 4P MCCB incomer and 8 nos 63 A 3P MCB with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment including supply and fixing double door sheet steel (16SWG), powder coated cable end box. [Emergency] (Make L&T / ABB / SIEMENS / SCHNEIDER / C&S ) ( Raw Power-1) ( DG power-1)
S & F of 415V, 8 way TPN Horizontal double door MCB DB (Legrand make ) in sheet steel enclosure outgoing consisting of 18 nos. 6-32 A. (C- Curve, 10 KA) SP MCB & 1 no. 63 A., 4 pole, MCB isolator recessed in wall incl. mending good the damages to original finish and earthing attachment as per G.S.(Make L&T / ABB / SIEMENS / SCHNEIDER / C&S )
S & F of 415V, 6 way TPN Horizontal double door MCB DB (Legrand make ) in sheet steel enclosure outgoing consisting of 18 nos. 6-32 A. (C- Curve, 10 KA) SP MCB & 1 no. 63 A., 4 pole, MCB isolator recessed in wall incl. mending good the damages to original finish and earthing attachment as per G.S.(Make L&T / ABB / SIEMENS / SCHNEIDER / C&S )
Supplying and fixing 6/8 way double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment,
Supplying and fixing 8 way double door sheet steel (16SWG), powder coated cable end box for TPN DB vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment
Supply and fixing 2+12 way SPMCBDB double door with 40 A SP isolator and 12 Nos SP MCB fixed in it flushed in wall and mending good the damages as to G S. ( Make L&T / ABB / SIEMENS / SCHNEIDER / C&S )
Supply and fixing 2+8 way SPMCBDB double door with 40 A SP isolator and 8 Nos SP MCB fixed in it flushed in wall and mending good the damages as to G S. ( Make L&T / ABB / SIEMENS / SCHNEIDER / C&S )
Supply and fixing 2+4 way SPMCBDB double door with 40 A SP isolator and 4 Nos SP MCB fixed in it flushed in wall and mending good the damages as to G S. (for D G Room) ( Make L&T / ABB / SIEMENS / SCHNEIDER / C&S )
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand KEI /POLYCAB / RR KABLE / L&T ) of the following sizes in 19/25mm polythene pipe(Precision make) and by the GI fish wire and making necy. connection as required 3 x (1.5 sqmm) as ECC
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) as ECC
2 x (6 sqmm) + 1x (4 sqmm) as ECC
2 x (6 sqmm) + 1x (4 sqmm)as ECC (For UPS)
4 x 126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 3x 1.5 sq mm
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) as ECC
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Earthing with 50 mm dia. ISI- Medium GI Pipe 3.64 mm thick x 3.04 Mts. Long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. Long), 13mm dia. x 80 mm long GI bolts, double nuts, double washers incl. S&F 15mm dia. GI Pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground leve including masonary enclosure CI cover and treatment of soil. [ 2(a)/G-1]
Connecting the equipments body to earth busbar including S&F 10 SWG galvanised (Hot Dip) wire on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. (Equipment Earthing)
Earth Continuity Conductor No. 4 SWG
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall.
Supply of 2/4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make HAVELLS / Gloster/KEI/Polycab / RR KABLE] 4 Core 150 Sq. mm (Substation to panel connection & DG & old DG to panel,)
4 Core 50 Sq. mm
Laying of cable through saddle & clamps & U G Trench 4 Core 150 Sq. mm in U G Trench
4 Core 50 Sq. mm in through saddle and clamps
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable 4 Core as per GS. 4 Core 150 Sq. mm
4 Core 50 Sq. mm
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy.connections with PVC Cu wire and earth continuity wire etc.(ac point)
S & F 4 module GI modular type box with ceiling plate complete set
S & F 2 module GI modular type box with ceiling plate complete set
25mm dia pvc pipe with 1x18 swg GI wire as fish wire
Supplying and fixing 200A 415V TPN with fuse on L&N Sheet steel Main Switches on angle iron frame on wall (Make L&T / ABB / SIEMENS / SCHNEIDER / C&S )
Supplying and fixing 160 A 4P Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (Make Havells/HPL/C&S/L&T ).(panel )
Supply & Fixing of 1200mm (48 inch) sweep AC ceiling fan Complete with all accessories. blades, canopy, fork, rubber bush etc. [CROMPTON / ORIENT / BAJAJ ) incl. modular fan regulator.
Supply and 400 mm sweep metal body wall fan incl fixing arrangement on wall (Make- Crompton / ORIENT / EPC / BAJAJ )
Supply & Fixing of 230V 4ft ENDURA LED light fittings complete with all allied accessories, Incl necy connections. Double tube fitting (Philips Cat No-BN308C LED20S-6500 L120 PSU WH 9405 / EQUIVALENT CROMPTON / BAJAJ)
Supply & Fixing foot lamp set for fixing after cutting tiles (MAKE : LEGRAND / HAVELLS / PHILLIPS / CROMPTON )
Supply & Fixing of 230V 4ft polycarbonate LED light fittings complete with all allied accessories, LED tube light , Incl necy connections. Double tube fitting with two nos LED tube 1200 mm 18W, 2100 lumen , ( MAKE : HAVELLS / PHILIPS / CROMPTON / BAJAJ )
S & F of 12" sweep AC exhaust fan incl. making hole on wall with nuts & bolts as required with louver shutter. (EPC heavy duty) 1420 r.p.m. and S & F louver with nuts and bolts. (Make- Crompton / ORIENT / EPC / BAJAJ )
UPS SYSTEM & Allied connection SITC of UPS incl. battery bank of 40 KVA36000 VAH ( SMF Battery) 12 Volt 3ph input /3ph output inbuilt isolation transformer , static by pass arrangement, compitable with D.G. Set , DSP controlled IGBT based rectifire with 90% efficincy on 100% Load. The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 100% Load, Wave form Pure Sine wave. It Should be operated 50˚ c above ambient temprature built in solid state float cum boost charger with autimatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load /Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage/ under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low,Static by-pass ON, Over temperature. Battery set Complete with self standing cubicle or cabinet. The UPS battery shall be Regulated Sealed Lead Acid Battery Construction type (AGM or VRSLAB) in ABS Flame Retardant Rating, 36000 VAH (12V, SMF Battery).Amavraya Quntra/ Exide Power Safe. Power Safe. Back up time : 30 Min at full load.Warranty : One Year on UPS and two Years on SMF Battery on site against any manufacturing defects.Certificate:ISO 9001:2015,ISO 14001:2015,IOS 18001,OHSAS 18001.CE Certification: IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950(Safety),IEC/EN 50091-2,IEC/EN 62040-2(EMC Emmission), IEC/EN 62040-3(Performance &Design),IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146(Design & Manufacture) Make: APC/NUMERIC/Power One
standing cubicle or cabinet. The UPS battery shall be regulated sealed Lead Acid Battery Construction type (AGM or VRSLAB) in ABS Flame Retardant Rating 40 KVA, 3ph input / Output Capacity: 36000 VAH (12V, SMF Battery).Amavraya Quntra/ Exide Power Safe. Capacity: 36000 VAH (12V, SMF Battery). 30 Min at full load. Warranty : One Year on UPS and two Years on SMF Battery on site against any manufacturing defects.Certificate:ISO 9001:2015,ISO 14001:2015,IOS 18001,OHSAS 18001.CE Certification: IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950(Safety),IEC/EN 50091-2,IEC/EN 62040-2(EMC Emmission), IEC/EN 62040-3(Performance &Design),IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146(Design & Manufacture) Make: Make: APC/NUMERIC/Power One / Switching Avo / Vertiv / Dell
S&F 415V 63A TPN MCB 10KA (C. Curve) in SS enclosure fixed on wall and necy. Connection.(L&T / ABB / Legrand / Siemens ) ( For Auto clave & UPS)
Supply, Installation, Testing & Commissioning of 3 phase, 415V, 50 HZ, 160 KVA ( ISO 8528) Silent Diesel Generator Set comprising of Engine, Alternator, AMF panel, Base frame, Fuel tank, Battery, CPCB approved acoustic enclosure incl all interconnection between Generator and AMF panel etc having following specification: Engine: (a) Make- Make : KOEL GREEN /Crompton Greaves/ CUMMINS/Volvo/Parkins/Eicher/ Ashok Leyaland / Greaves Power / Mahindra (b)Aspiration- Turbo Charged. (c) No of Stroke- 4 (d) RPM- 1500 (e) Required Power for Rated kVA (bhp) - 200 ( Prime Continuous ) (f) Battery- 12 volt DC with connecting leads & terminals. Make: Exide/ Amaron
(g) Type of Cooling- Turbo Charged. (h) Air Intake System- Air intake manifold with air filter system. (i) Exhaust System- Residential exhaust silencer with flexible bellow and companion flanges inside the acoustic enclosure. (j) Coupling & Fly Wheels- Befitting coupling, Fly wheel & Fly wheel housing. (k) Lubricating System- Provided with Oil pan, engine mounted lube oil pump and lube oil filter along with first fill of lube oil. (l) Fuel System- Comprising of fuel pump with Electronic Governor, 12V solenoid coil and replaceable fuel filter. (m) Starting System- 12V DC electric starter and 12V Battery charging alternator.
(n) Safety Control- Comprising of protection against low lube oil pressure trip, high coolant temperature trip & Emergency stop switch. Engine over speed indicator, Battery charging and low battery indicator (o) Power Start Control: (i) Provided with Microprocessor based generator set monitoring & control system mounted in the Genset Control Panel. (ii) LED Lamp indication for GENSET RUNNING REMOTE START, SHUT DOWN, (iii) Data Log includes Engine run time & Controller on time. (iv) Engine Data Display Arrangement - Starting Battery Voltage, Engine Running Hour, Engine Temperature & engine oil pressure. (p) Lub oil consumption- Should be < 0.5% of S.F.C. (q) Fuel Consumption at 75 % full Load 29 ltrs or less (r) Fuel Consumption at 100 % full Load 39 ltrs or less
Alternator : (a) Make : KOEL GREEN /Stamford/ Leroy Somer/ Crompton Greaves / ABB / ALSTHOM (b) Rating: 160 KVA 415 V., 3Ph. 50 Hz. 1500 RPM with Class - H Insulation. (c) Type of Alternator: Brushless, self excited & self-regulated through (d) Voltage Regulation: ± 1% (max.) (e) Overload: Permissible overload of 10% for 1 hour in 12 hours of operation, (f) Protection: IP - 23 protections . (g) Winding connection : Star with Neutral (h) Total Harmonic Distortion : less than 3 % BASE FRAME: Common MS Channel fabricated base frame, primer coated & painted, containing the engine and the alternator mounted through AVM Pads.
Fuel Tank: 350 LTRS, detachable tank built inside base frame complete with drain valve, air vent inlet & outlet connections, fuel gauge filled with full HSD oil
Acoustic Enclosure: High quality, sound proof, weatherproof, environment friendly Acoustic Enclosure fabricated from 16 SWG Sheet Steel & powder coated, specially design to meet up CPCB standards to maintain the noise level below 75dB (A) at a distance of 1 Meter from acoustic enclosure under free field condition. NOTE: i) Efficiency not less than 90% . ii) Warranty 2 Years or 5000 hours whichever is earlier.(including freight charge)
Supply & fixing of exhaust gas piping of 125 mm dia MS black class B pipe welded incl. all necessary bend supports and clamps anti vibration mounting insulation of exhaust system with 50 mm thick mineral wool covered with wire mesh and aluminium cladding ( from DG sets to top of the building plus 3mtr or as per CPCB) for 160 KVA DG set as per direction of EIC.
S&F special type MS angle iron( Latice Type) structure support made of 50x50x6 mm. MS angle with 40X40X5mm M S angle bracing with proprely welded and required nuts ,bolts and washers etc. for holding 125 mm. dia exhaust line.
S& delivery of 200 ltrs. Capacity heavy gauge MS sheet barrel with MS angle made support stand.
Supply & delivery of best quality oil hand pump with 1" dia PVC flexible pipe (12' ft. approx.)
S& laying 120 sq. mm. single core multistrand PVC insulated flexible Cu wire in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to transformer point as required (for Transformer /Generator neutral earthing) including Socketing both sides by Cu Socket.
Supply and Fixing rain protection canopy
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Connecting the equipments body to earth busbar incl. S & F 40 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
Construction of Room by supplying materials, Mason, Labour, Welder and other technician for installation of D.G. Set of room size inner dimension (24'Ft x 16'Ft) of height at the centre point (approx) 16'Ft. of corrugated sheet both side sloping (TATA - Make) of required gauge as per direction of EIC including earth work in excavation , brick flat soling and construction of 5" thick wall with cement mortar (6:1) over 10" wall base (2'x-0") foundation and 11 (eleven) Nos. (10" x10") brick pillar of height 8'Ft (6'Ft over G.L and 2'Ft below G.L), 11(eleven) Nos. 17'Ft height (4" x 3") Square type hollow bar support and Zigzag hollow bar structure with welding works to support corrugated shed with extra 2'Ft. Length both side i.e. Length of the shed 19'-0" the upper part above 5" inch thick wall should be covered by required gauge net with welding works for fixing 2" wide G.I path both side of the net and painting as per direction. The D.G. room should have a gate with locking arrangement. The entrance gate should be made of (1.5" x 1") Square type hollow bar. The size of the door should be (10'Ft x 1'Ft.10") of 2 part system fixed with big size heavy gauge kabja - 6 Nos.
The 5" thick wall all round should be finished with net cement works both side of lower part at about 1'-6" height and rest part of the wall should be ½" plastered both side by cement mortar (6:1) including making base for D.G. Set of size (4200mm x 1800 mmt) and height 3"-0" (1'Ft.10"inch above G.L and 1'Ft. 2" inch below G.L. The internal construction of the base for D.G Set should be consisting of P C.C (4:2:1) l all along. C.C work (4:2:1) with net cement work over the base all side required for finishing.
Dismantling the existing wiring, PBDB, SPNDB, main switch, Tube fittings, Ceiling Fan, different size cables and wire etc. and mending goods the damages to original finish and supply to Kandi section office store, also replacing old accessories as per direction of site engineer.
B.B.R.C UNEMPLOYED ENGINEERS CO-OPERATIVE SOCIETY LTD.
SANJIB GHOSH
MONDAL ENTERPRISE
ASIM KRISHNA MODAK
M/S INDRADEEP ENTERPRISE
stage.html
html • 0.06 MB
technical_681698.pdf
PDF • 0.39 MB
techsummary_681698.pdf
PDF • 0.39 MB
finance_681698.pdf
PDF • 0.36 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_681698.pdf
PDF • 0.02 MB
ProvisionalMGEnterprise.PDF
PDF • 0.79 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .