Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 39A FIRST MAIN ROAD BARATHI NAGAR AMBATTUR CHENNAI TAMIL NADU 600053 | THIRUVALLUR | TAMIL NADU | 600053 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 12 4 SRS ROAD1ST CROSS PEENAY NEW EXTENSION YESHWANTHPUR BANGALORE BANGALORE BANGALORE KARNATAKA 560058 | BENGALURU URBAN | KARNATAKA | 560058 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
29 Jul 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dy Chief Engineer PD and EP
Dy Chief Engineer PD and EP 2nd Floor PD building NFC HYDERABAD
Supply Installation Testing and Commissioning of Protection relays and dismantling of existing relays
2025_NFC_864363_1
NFC/PD/04/2025
Open Tender
Electrical Works
Item Rate
NFC Hyderabad
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹62,000
5 Aug 2025
13 Jun 2025
5 Aug 2025
13 Jun 2025
29 Jul 2025
19 Jun 2025
13 Jun 2025 - 16 Jul 2025
Amount
Numerical generator protection multifunctional relay with rated current of 1A/5A, 110V PT secondary voltage, auxiliary supply of 110V DC, rated frequency: 50Hz offering the following protections: Overcurrent, Overvoltage and under voltage, reverse power, negative sequence, filed failure, under and over frequency, etc as per technical specifications with communication over IEC 61850 with dual RJ45 ports and 10 Nos. of DI/Dos. Relay terminals shall be protected by surge protection device
Supply
Installation (includes mounting of the relay and necessary wiring works with necessary control circuit modifications), testing and commissioning as per tender specifications and instructions of engineer-in-charge
Isolation and dismantling of existing multiple electromechanical generator protection relays (Make: English Electric and Alstom) and their sensing circuits as per tender specifications and instructions of engineer-in-charge
Installation (includes mounting of the relay and necessary wiring works with necessary control circuit modifications), testing and commissioning of P643 relays (3 winding transformer differential relays Make: Alstom) as per tender specifications and instructions of engineer-in-charge (Note Relay shall be supplied by NFC for this purpose)
Isolation and dismantling of existing multiple transformer protection relays (Make: English Electric and Alstom, Model: DTH 32) and interposing CTs and modification of existing CT circuit connections as per tender specifications and instructions of engineer-in-charge
Supply, installation, testing and commissioning of the following relays as per tender specifications and instructions of engineer-in-charge (Dimension, auxiliary supply voltage, PT input, CT input, type and number of contacts, communication protocol and type of mounting shall match with the indicated model of relay):
Relay equivalent to Model: CV2D2J of ABB
Supply
Installation
Relay equivalent to Model: V1R12JA of ABB
Supply
Installation
Relay equivalent to Model: VAX31ZG8072B of Alstom
Supply
Installation
Relay equivalent to Model: VAJC11BF8055A of Alstom
Supply
Installation
Relay Model: P111 with RS 485 ports for communication on MODBUS RTU
Supply
Installation
Relay equivalent to Model: VAJH13YF62B
Supply
Installation
Relay equivalent to Model: VAA33ZG8338BCH
Supply
Installation
Relay equivalent to Model: P3U30 of Schneider with 2 Nos. of RJ 45 ports for communication on MODBUS TCP/IP
Supply
Installation after removing existing relay of ADR 241B of Ashida
Supply of Relay equivalent to Model: PQ8NCH2JS of ABB
Relay equivalent to Model: VAGM23AF15G
Supply
Installation
Relay equivalent to Model: VAJC11BF8203ACH
Supply
Installation
Relay equivalent to Model: CTU12BF8096A (M)
Supply
Installation
Relay equivalent to Model: VAA33ZG8338B (M)
Supply
Installation
Relay equivalent to Model: VTT11ZG8144B (M)
Supply
Installation
Supply of Relays Model: SPAJ 140C of ABB
Supply of Relays equivalent to Model: TCS of ABB
Testing of the following model of protection relays as per tender specifications
SPAJ 140C
SPAU 130C
ACCUM-33
PQ8NCH2JS
Micom P111
AGIES
SPAD 346C3
SPAM 150C
P8NCH2J
GRENEL POWERS PVT.LTD. (BID ID -3241970)
stage.html
html • 0.02 MB
finance_908722.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .